H.0 Uplink Signal Levels
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
Uplink signal power is a UE figure, which is configured by the Test System by means of:
RRC messages (IE-s), such as:
– UplinkPowerControlCommon (-v1020, SCell-r10),
– UplinkPowerControlDedicated (-v1020, SCell-r10),
– Other IE-s affecting directly or indirectly the uplink power,
and L1/2 Power control commands (TPC).
The uplink power settings are specified in the test case.
Otherwise, the uplink power settings result from the default RRC messages described in 3GPP TS 36.508 [7], and appropriate TPC-s, which are sent to the UE to transmit with an UL power level necessary for maintaining the call during the test.
H.0.1 Uplink Signal Levels for NB1
Uplink signal power is a UE figure, which is configured by the Test System by means of:
RRC messages (IE-s), such as:
– NPUSCH-ConfigCommon-NB
– NPUSCH-ConfigDedicated-NB
– UplinkPowerControl-NB
– Other IE-s affecting directly or indirectly the uplink power,
The uplink power settings are specified in the test case.
Otherwise, the uplink power settings result from the default RRC messages described in 3GPP TS 36.508 [7], which are sent to the UE to transmit with an UL power level necessary for maintaining the call during the test.