7.6.3B Narrow band blocking for UL-MIMO

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

7.6.3B.1 Test Purpose

Narrow band blocking for UL-MIMO is defined for an unwanted CW interfering signal falling near the UE that supports UL-MIMO receive band, at which a given average throughput shall meet or exceed the requirement for the specified measurement channels,

The lack of narrow-band blocking ability will decrease the coverage area when other e-NodeB transmitters exist (except in the adjacent channels and spurious response).

7.6.3B.2 Test Applicability

This test applies to all types of E-UTRA UE release 10 and forward that support UL-MIMO.

7.6.3B.3 Minimum Conformance Requirements

For UE with two transmitter antenna connectors in closed-loop spatial multiplexing scheme, the minimum requirements in clause 7.6 shall be met with the UL-MIMO configurations specified in Table 6.2.2B-2. For UL-MIMO, the parameter PCMAX_L is defined as the total transmitter power over the two transmit antenna connectors.

7.6.3B.4 Test Description

7.6.3B.4.1 Initial Conditions

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in table 5.4.2.1-1. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 7.6.3B.4.1-1. The details of the uplink and downlink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3 respectively. The details of the OCNG patterns used are specified in Annex A.5. Configurations of PDSCH and PDCCH before measurement are specified in Annex C.2.

Table 7.6.3B.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in

TS 36.508 [7] clause 4.1

NC

Test Frequencies as specified in

TS 36.508 [7] clause 4.3.1

Mid range

Test Channel Bandwidths as specified in

TS 36.508 [7] clause 4.3.1

Lowest, 5MHz, Highest

Test Parameters for Channel Bandwidths

Downlink Configuration

Uplink Configuration

Ch BW

Mod’n

RB allocation

Mod’n

RB allocation

FDD

TDD

FDD

TDD

1.4MHz

QPSK

6

6

QPSK

6

6

3MHz

QPSK

15

15

QPSK

15

15

5MHz

QPSK

25

25

QPSK

25

25

5MHz

QPSK

25

N/A

QPSK

20

N/A

5MHz

QPSK

25

N/A

QPSK

15

N/A

5MHz

QPSK

25

N/A

QPSK

54

N/A

10MHz

QPSK

50

50

QPSK

50

50

10MHz

QPSK

50

N/A

QPSK

25

N/A

10MHz

QPSK

50

N/A

QPSK

20

N/A

10MHz

QPSK

50

N/A

QPSK

15

N/A

15MHz

QPSK

75

75

QPSK

75

75

15MHz

QPSK

75

N/A

QPSK

50

N/A

15MHz

QPSK

75

N/A

QPSK

25

N/A

15MHz

QPSK

75

N/A

QPSK

20

N/A

20MHz

QPSK

100

100

QPSK

100

100

20MHz

QPSK

100

N/A

QPSK

75

N/A

20MHz

QPSK

100

N/A

QPSK

50

N/A

20MHz

QPSK

100

N/A

QPSK

25

N/A

20MHz

QPSK

100

N/A

QPSK

20

N/A

Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, which applicable channel bandwidths are specified in Table 5.4.2.1-1.

Note 2: Depending on E-UTRA band, only the appropriate Uplink RB allocation value according to table 7.3.3-2 is tested per Test Channel Bandwidth.

Note 3: For the DL signal one sided dynamic OCNG Pattern OP.1 FDD/TDD is used.

Note 4: Applicable only to E-UTRA FDD Bands 31 and 72. The UL resource blocks shall be located at RBstart 10 (according to Table 7.3.3-2).

1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A, Figure A.30.

2. The parameter settings for the cell are set up according to TS 36.508 [7] clause 4.4.3.

3. Downlink signals are initially set up according to Annex C0, C.1 and C.3.1, and uplink signals according to Annex H.1 and H.3.1

4. The UL and DL Reference Measurement channels are set according to Table 7.6.3B.4.1-1.

5. Propagation conditions are set according to Annex B.0.

6. Ensure the UE is in State 3A-RF according to TS 36.508 [7] clause 5.2A.2. Message contents are defined in clause 7.6.3B.4.3.

7.6.3B.4.2 Test Procedure

1. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.3B.4.1-1. The SS sends downlink MAC padding bits on the DL RMC.

2. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 4 for C_RNTI to schedule the UL RMC according to Table 7.6.3B.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

3. Set the parameters of the CW signal generator for an interfering signal below the wanted signal according to Table 7.6.3B.5-1.

4. Set the downlink signal level according to the table 7.6.3B.5-1. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in table 7.6.3B.5-1 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement and the UE output power is mean sum power of each antenna connector for UE.

5. Measure the average throughput for a duration sufficient to achieve statistical significance according to Annex G.2.

6. Repeat steps from 3 to 5, using an interfering signal above the wanted signal at step 3.

7.6.3B.4.3 Message Contents

Message contents are according to TS 36.508 [7] clause 4.6 with the following exception.

Table 7.6.3B.4.3-1: UplinkPowerControlDedicated

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE {

p0-UePUSCH

0

deltaMCS-Enabled

en0

accumulationEnabled

TRUE

p0-uePUCCH

0

pSRS-Offset

3 (-6 dB)

filterCoefficient

fc8

larger filter length is used to reduce the RSRP measurement variation

}

7.6.3B.5 Test Requirement

The throughput measurement derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.6.3B.5-1.

Table 7.6.3B.5-1: Narrow-band blocking

Parameter

Unit

Channel Bandwidth

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Pw

dBm

PREFSENS + channel-bandwidth specific value below

22

18

16

13

14

16

Puw (CW)

dBm

-55

-55

-55

-55

-55

-55

Fuw (offset for

f = 15 kHz)

MHz

0.9075

1.7025

2.7075

5.2125

7.7025

10.2075

Fuw (offset for

f = 7.5 kHz)

MHz

Note 1: The transmitter shall be set a 4 dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5.

Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1.

For the UE which supports inter band CA configuration in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, Puw power defined in Table 7.6.3B.5-1 is increased by the amount given by ΔRIB,c in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.