7.4A.1 Maximum input level for CA (intra-band contiguous DL CA and UL CA)

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

Editor’s note:

– Any restriction of the applicability of test points due to the supported UE category is under investigation

7.4A.1.1 Test purpose

Maximum input level for CA test verifies the UE’s ability to receive data with a given average throughput for a specified reference measurement channel, under conditions of high signal level, ideal propagation and no added noise.

A UE unable to meet the throughput requirement under these conditions will decrease the coverage area near to an e-NodeB.

7.4A.1.2 Test applicability

This test applies to all types of E-UTRA UE release 10 and forward that support intra-band contiguous DL CA and UL CA.

7.4A.1.3 Minimum conformance requirements

The minimum conformance requirements are defined in clause 7.4A.0.

7.4A.1.4 Test description

7.4A.1.4.1 Initial conditions

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA CA configurations specified in table 5.4.2A.1-1. All of these configurations shall be tested with applicable test parameters for each CA Configuration, and are shown in table 7.4A.1.4.1-1. The details of the uplink and downlink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3 respectively. The details of the OCNG patterns used are specified in Annex A.5. Configurations of PDSCH and PDCCH before measurement are specified in Annex C.2.

Table 7.4A.1.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in TS 36.508[7] clause 4.1

NC

Test Frequencies as specified in TS36.508 [7] clause 4.3.1 for different CA bandwidth classes, and PCC and SCCs are mapped onto physical frequencies according to Table 7.1-2

Mid range

Test CC Combination setting (NRB_agg) as specified in clause 5.4.2A.1 for the CA Configuration across bandwidth combination sets supported by the UE.

Lowest NRB_agg
Highest NRB_agg

(Note 3)

Test Parameters for CA Configurations

CA Configuration / NRB_agg

DL Allocation

UL Allocation

PCC
NRB

SCC
NRB

CC
MOD

PCC & SCC RB allocation

CC
MOD

NRB_alloc

PCC & SCC RB allocations
(LCRB @ RBstart)

25

25

64-QAM

25+25

QPSK

50

P_25@0

S_25@0

50

25

64-QAM

50+25

QPSK

25

P_25@25

S_0@0

50

50

64-QAM

50+50

QPSK

25

P_25@25

S_0@0

50

100

64-QAM

50+100

QPSK

150

P_50@0

S_100@0

75

25

64-QAM

75+25

QPSK

100

P_75@0

S_25@0

75

50

64-QAM

75+50

QPSK

75

P_75@0

S_0@0

75

75

64-QAM

75+75

QPSK

75

P_75@0

S_0@0

75

75

64-QAM

75+75

QPSK

129

P_75@0

S_54@0

75

75

64-QAM

75+75

QPSK

150

P_75@0

S_75@0

100

25

64QAM

100+25

QPSK

50

P_50@0

S_0@0

100

25

64-QAM

100+25

QPSK

125

P_100@0

S_25@0

100

50

64-QAM

100+50

QPSK

75

P_75@25

S_0@0

100

50

64-QAM

100+50

QPSK

150

P_100@0

S_50@0

100

75

64-QAM

100+75

QPSK

175

P_100@0

S_75@0

100

100

64-QAM

100+100

QPSK

50

P_50@50

S_0@0

100

100

64-QAM

100+100

QPSK

75

P_75@25

S_0@0

100

100

64-QAM

100+100

QPSK

130

P_100@0

S_30@0

100

100

64-QAM

100+100

QPSK

200

P_100@0

S_100@0

Note 1: CA Configuration Test CC Combination settings are checked separately for each CA Configuration, which applicable aggregated channel bandwidths are specified in Table 5.4.2A.1-1.

Note 2: Depending on CA Configuration only the appropriate Uplink RB allocation value according to table 7.3A.0-1 is tested per CA Configuration Test CC combination.

Note 3: If the UE supports multiple CC Combinations in the CA Configuration with the same NRB_agg , only the combination with the highest NRB_PCC is tested.

1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A, Figure group A.32 as appropriate if the UE supports 2 Rx antennas or Figure A.80 if the UE supports 4 Rx antennas in the band.

2. The parameter settings for the cell are set up according to TS 36.508 [7] clause 4.4.3.

3. Downlink signals for PCC are initially set up according to Annex C.0, C.1 and C.3.1, and uplink signals according to Annex H.1 and H.3.1

4. The UL and DL Reference Measurement channels are set according to Table 7.4A.1.4.1-1.

5. Propagation conditions are set according to Annex B.0.

6. Ensure the UE is in State 3A-RF according to TS 36.508 [7] clause 5.2A.2. Message contents are defined in clause 7.4A.1.4.3.

7.4A.1.4.2 Test procedure

1. Configure SCC according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.

2. The SS shall configure SCC as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.4A.1.4.3

3. SS activates SCC by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).

4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.4A.1.4.1-1 on both PCC and SCC. The SS sends downlink MAC padding bits on the DL RMC.

5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.4A.1.4.1-1 on both PCC and SCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.

6. Set the Downlink signal level for PCC and SCC to the value defined in Table 7.4A.1.5-1. Send Uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that for at least the duration of the Throughput measurement:
The PCC output power is within (+0dB, -3.4 dB) of (target level in Table 7.4A.1.5-1 + 10log(P_LCRB/NRB_alloc)), for carrier frequency f ≤ 3.0GHz,
or within (+0dB, -4 dB) of (target level in Table 7.4A.1.5-1 + 10log(P_LCRB/NRB_alloc)) for carrier frequency 3.0GHz < f ≤ 4.2GHz.
The SCC output power is within (+0dB, -3.4 dB) of (target level in Table 7.4A.1.5-1 + 10log(S_LCRB/NRB_alloc)), for carrier frequency f ≤ 3.0GHz,
or within (+0dB, -4 dB) of (target level in Table 7.4A.1.5-1 + 10log(S_LCRB/NRB_alloc)) for carrier frequency 3.0GHz < f ≤ 4.2GHz.

7. Measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.

7.4A.1.4.3 Message contents

Message contents are according to TS 36.508 [7] subclause 4.6 with the following exception.

Table 7.4A.1.4.3-1: UplinkPowerControlDedicated

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE {

p0-UePUSCH

0

deltaMCS-Enabled

en0

accumulationEnabled

TRUE

p0-uePUCCH

0

pSRS-Offset

3 (-6 dB)

filterCoefficient

fc8

larger filter length is used to reduce the RSRP measurement variation

}

Table 7.4A.1.4.3-2: UplinkPowerControlDedicatedSCell-r10

Derivation Path: 36.508 clause 4.6.3

Information Element

Value/remark

Comment

Condition

UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE {

p0-UE-PUSCH-r10

0

deltaMCS-Enabled-r10

en0

accumulationEnabled-r10

TRUE

pSRS-Offset-r10

7 (0 dB)

The actual parameter value is -10.5 + 1.5*pSRS-Offset value; 0 is the actual value in dB (-10.5 + 1.5*7 dB).

pSRS-OffsetAp-r10

7 (0 dB)

The actual parameter value is -10.5 + 1.5*pSRS-Offset value; 0 is the actual value in dB (-10.5 + 1.5*7 dB).

filterCoefficient-r10

fc8

larger filter length is used to reduce the RSRP measurement variation

pathlossReferenceLinking-r10

sCell

}

7.4A.1.5 Test requirement

The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.4A.1.5-1.

Table 7.4A.1.5-1: Maximum input level for intra-band contiguous CA

Rx Parameter

Units

CA Bandwidth Class

A

B

C

D

E

F

Power in largest Transmission Bandwidth Configuration CC

dBm

For carrier frequency f ≤ 3.0GHz: -28.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -29.0

For carrier frequency f ≤ 3.0GHz: -25.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -26.0

Power in each other CC

dBm

For carrier frequency f ≤ 3.0GHz: -28.7 + 10log(NRB,c /NRB,largest BW)

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -29.0 + 10log(NRB,c /NRB,largest BW)

For carrier frequency f ≤ 3.0GHz: -25.7 + 10log(NRB,c /NRB,largest BW)

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -26.0 + 10log(NRB,c /NRB,largest BW)

Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5 for one uplink carrier and in subclause 6.2.5A for two uplink carriers.

Note 2: Reference measurement channel is Annex A.3.2: 64QAM, R=3/4 variant with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1.