6.3.3E UE Transmit OFF power for UE category 0
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.3.3E.1 Test purpose
Same test purpose as in clause 6.3.3.1.
6.3.3E.2 Test applicability
The requirements of this test apply in test cases 6.3.4E.1 General ON/OFF time mask and 6.3.4E.2 PRACH and SRS time mask to all types of E-UTRA UE release 12 and forward of UE category 0.
6.3.3E.3 Minimum conformance requirement
Same minimum conformance requirements as in clause 6.3.3.3
6.3.3E.4 Test description
This test is covered by clause 6.3.4E.1 General ON/OFF time mask and 6.3.4E.2 PRACH and SRS time mask.
6.3.3E.5 Test requirement
The requirement for the transmit OFF power shall not exceed the values specified in Table 6.3.3E.5-1.
Table 6.3.3E.5-1: Transmit OFF power
Channel bandwidth / Transmit OFF power / measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Transmit OFF power |
For carrier frequency f ≤ 3.0GHz: ≤ -48.5 dBm For carrier frequency 3.0GHz < f ≤ 4.2GHz: ≤ -48.2 dBm |
|||||
Measurement bandwidth |
1.08 MHz |
2.7 MHz |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |