F.3.5 Measurement of Channel State Information reporting

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

Table F.3.5-1: Derivation of Test Requirements (Channel State Information reporting tests)

Test

Minimum Requirement in TS 36.101

Test Tolerance
(TT)

Test Requirement in TS 36.521-1

9.2.1.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-0

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.1.2 TDD CQI Reporting under AWGN condit.1ions – PUCCH 1-0

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.1.3_C.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for eICIC (non-MBSFN ABS)

Values as specified

Limits as in the Test Procedure

No test tolerances applied

The analysis is recorded in 3GPP TR 36.904 [17]

9.2.1.4_C.1 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for eICIC (non-MBSFN ABS)

Values as specified

Limits as in the Test Procedure

No test tolerances applied

The analysis is recorded in 3GPP TR 36.904 [17]

9.2.1.5_E.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for feICIC (non-MBSFN ABS)

Values as specified

Limits as in the Test Procedure

No test tolerances applied

The analysis is recorded in 3GPP TR 36.904 [17]

9.2.1.6_E.1 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for feICIC (non-MBSFN ABS)

Values as specified

Limits as in the Test Procedure

No test tolerances applied

The analysis is recorded in 3GPP TR 36.904 [17]

9.2.1.7 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for 256QAM in DL

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.1.8 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for 256QAM in DL

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.2.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-1

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.2.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-1

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.3.1_D FDD CQI Reporting under AWGN conditions – PUCCH 1-1 for eDL-MIMO

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.3.2_D TDD CQI Reporting under AWGN conditions – PUCCH 1-1 for eDL-MIMO

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.3.1A FDD CQI Reporting under AWGN conditions – PUCCH 1-1 for FD-MIMO (With channelMeasRestriction configured)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.3.2A TDD CQI Reporting under AWGN conditions – PUCCH 1-1 for FD-MIMO (With channelMeasRestriction configured)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.4.1A FDD CQI Reporting under AWGN conditions – Single CSI Process With interferenceMeasRestriction configured

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.4.1_F FDD CQI Reporting under AWGN conditions – Single CSI Process for CoMP

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.4.2A TDD CQI Reporting under AWGN conditions – Single CSI Process With interferenceMeasRestriction configured

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.4.2_F TDD CQI Reporting under AWGN conditions – Single CSI Process for CoMP

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.5 TDD CQI Reporting under AWGN conditions – PUCCH 1-1 (when csi-SubframeSet – r12 and EIMTA-MainConfigServCell-r12 are configured)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.6.1 LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with FDD as Pcell (PUSCH 3-0)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.6.2 LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with TDD as Pcell (PUSCH 3-0)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.7.1 LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with FDD as Pcell (PUSCH 3-1)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.2.7.2 LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with TDD as Pcell (PUSCH 3-1)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.3.1.1.1 FDD CQI Reporting under fading conditions – PUSCH 3-0

SNRs as specified

2%

55%

1.10

BLER 0.05

SNR 0dB

0%

0%

0.01

BLER 0

SNR unchanged

 limit unchanged

limit unchanged

1.09 as per Table G.5.4-1

BLER limit unchanged

9.3.1.1.2 TDD CQI Reporting under fading conditions – PUSCH 3-0

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.3.1.1.5 TDD CQI Reporting under fading conditions – PUCCH 3-0 (when csi-SubframeSet –r12 is configured)

SNRs as specified

2%

55%

1.10

BLER 0.05~0.60

Delta CQI 3

SNR 0dB

0%

0%

0.01

BLER 0

Delta CQI 0

SNR unchanged

 limit unchanged

limit unchanged

1.09 as per Table G.5.4-1

BLER limit unchanged

Delta CQI limit unchanged

9.3.1.2.1_D FDD CQI Reporting under fading conditions – PUSCH 3-1 for eDL-MIMO

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.3.1.2.2_D TDD CQI Reporting under fading conditions – PUSCH 3-1 for eDL-MIMO

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.3.1.2.3 FDD CQI Reporting under fading conditions – PUSCH 3-1 for 256QAM in DL

SNRs as specified

2%

40

1.10

BLER 0.05

SNR 0dB

0%

0%

0.01

BLER 0

SNR unchanged

 limit unchanged

limit unchanged

1.09 as per Table G.5.4-1

BLER limit unchanged

9.3.1.2.4 TDD CQI Reporting under fading conditions – PUSCH 3-1 for 256QAM in DL

Same as 9.3.1.2.3

Same as 9.3.1.2.3

Same as 9.3.1.2.3

9.3.1.2.6 TDD CQI Reporting under fading conditions – PUCCH 3-1 (when csi-SubframeSet –r12 is configured with one CSI process)

SNRs as specified

2%

55%

1.02

BLER 0.01

Delta CQI 3

SNR 0dB

0%

0%

0.01

BLER 0

Delta CQI 0

SNR unchanged

 limit unchanged

limit unchanged

1.01 as per Table G.5.4-1

BLER limit unchanged

Delta CQI limit unchanged

9.3.1.3.1_E.1 FDD CQI Reporting under fading conditions – PUSCH 3-0 for feICIC (non-MBSFN ABS)

SNRs as specified

2%

55%

1.10

BLER 0.01

SNR 0dB

0%

0%

0.01

BLER 0

SNR unchanged

 limit unchanged

limit unchanged

1.09 as per Table G.5.4-1

BLER limit unchanged

The analysis is recorded in 3GPP TR 36.904 [17]

9.3.1.3.2_E.1 TDD CQI Reporting under fading conditions – PUSCH 3-0 for feICIC (non-MBSFN ABS)

Same as 9.3.1.3.1_E.1

Same as 9.3.1.3.1_E.1

Same as 9.3.1.3.1_E.1

9.3.2.1.1 FDD CQI Reporting under fading conditions – PUCCH 1-0

SNRs as specified

20%

1.05

BLER 0.02

SNR 0dB

0%

0.01

BLER 0

SNR and BLER limits unchanged

 limit unchanged

1.04 as per Table G.5.4-1

BLER limit unchanged

9.3.2.1.1_1 FDD CQI Reporting under fading conditions – PUCCH 1-0

Same as 9.3.2.1.1

Same as 9.3.2.1.1

Same as 9.3.2.1.1

9.3.2.1.2 TDD CQI Reporting under fading conditions – PUCCH 1-0

Same as 9.3.2.1.1

Same as 9.3.2.1.1

Same as 9.3.2.1.1

9.3.2.1.2_1 TDD CQI Reporting under fading conditions – PUCCH 1-0

Same as 9.3.2.1.1

Same as 9.3.2.1.1

Same as 9.3.2.1.1

9.3.2.2.1_D FDD CQI Reporting under fading conditions – PUCCH 1-1 for eDL-MIMO

Same as 9.3.2.1.1

Same as 9.3.2.1.1

Same as 9.3.2.1.1

9.3.2.2.2_D TDD CQI Reporting under fading conditions – PUCCH 1-1 for eDL-MIMO

Same as 9.3.2.1.1

Same as 9.3.2.1.1

Same as 9.3.2.1.1

9.3.3.1.1 FDD CQI Reporting under fading conditions and frequency-selective interference – PUSCH 3-0

Ior and Iot as specified

60%

1.60

Ior, Iot 0dB

20%

0.10

Ior and Iot unchanged

40%, Formula: Min Req’t – Test Tol

1.50, Formula: Min Req’t – Test Tol

The effect of AWGN flatness and signal flatness on the requirement was derived by simulation.

AWGN flatness / signal flatness and the statistical effect of a finite test time both affect the T-put result. The Test Tolerance comprises two quantities:

1. Effect of AWGN flatness and signal flatness, derived by simulation

2. Statistical effect as per Table G.5.4-1

Items 1 and 2 are assumed to be uncorrelated so can be root sum squared

T-put requirement Test Tol = SQRT (AWGN flatness and signal flatness effect 2 + Statistical effect 2)

AWGN flatness and signal flatness effect 0.1, Statistical effect 0.01, giving overall effect 0.10

9.3.3.1.2 TDD CQI Reporting under fading conditions and frequency-selective interference – PUSCH 3-0

Same as 9.3.3.1.1

Same as 9.3.3.1.1

Same as 9.3.3.1.1

9.3.4.1.1 FDD CQI Reporting under fading conditions – PUSCH 2-0

SNRs as specified

Limits as in the Test Procedure

1.2

0.01

SNR unchanged

1.19 as per Table G.5.4-1

9.3.4.1.2 TDD CQI Reporting under fading conditions – PUSCH 2-0

Same as 9.3.4.1.1

Same as 9.3.4.1.1

Same as 9.3.4.1.1

9.3.4.2.1 FDD CQI Reporting under fading conditions – PUCCH 2-0

SNRs as specified

Limits as in the Test Procedure

1.15

0.01

SNR unchanged

1.14 as per Table G.5.4-1

9.3.4.2.2 TDD CQI Reporting under fading conditions – PUCCH 2-0

Same as 9.3.4.2.1

Same as 9.3.4.2.1

Same as 9.3.4.2.1

9.3.5.1.1 FDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A

Noc: -98dBm/15kHz

DIP 1: -0.41dB

SINR: -2.00dB

1.8

BLER 0.02

0dB

+0.03dB

+0.03dB

0.01

Noc: -98dBm/15kHz

DIP 1: -0.38dB

SINR: -1.97dB

1.79 as per Table G.5.4-1

BLER limit unchanged

The analysis is recorded in 3GPP TR 36.904 [17]

9.3.5.1.2 TDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A

Same as 9.3.5.1.1

Same as 9.3.5.1.1

Same as 9.3.5.1.1

9.3.5.2.1 FDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A

Same as 9.3.5.1.1 Same as 9.3.5.1.1

Same as 9.3.5.1.1

Same as 9.3.5.1.1

9.3.5.2.2 TDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A

Same as 9.3.5.1.1

Same as 9.3.5.1.1

9.3.6.1_F FDD CQI Reporting under fading conditions Single CSI processes for CoMP

1.02

0.01

1.01 as per Table G.5.4-1

9.3.6.1_F.2 FDD CQI Reporting under fading conditions Three CSI processes for CoMP

Same as 9.3.6.1_F.1

Same as 9.3.6.1_F.1

Same as 9.3.6.1_F.1

9.3.6.1_F.3 FDD CQI Reporting under fading conditions Four CSI processes for CoMP

Same as 9.3.6.1_F.1

Same as 9.3.6.1_F.1

Same as 9.3.6.1_F.1

9.3.6.2_F.1 TDD CQI Reporting under fading conditions Single CSI processes for CoMP

1.02

0.01

1.01 as per Table G.5.4-1

9.3.6.2_F.2 TDD CQI Reporting under fading conditions Three CSI processes for CoMP

Same as 9.3.6.2_F.1

Same as 9.3.6.2_F.1

Same as 9.3.6.2_F.1

9.3.6.2_F.3 TDD CQI Reporting under fading conditions Four CSI processes for CoMP

Same as 9.3.6.2_F.1

Same as 9.3.6.2_F.1

Same as 9.3.6.2_F.1

9.3.7.1 FDD CQI Reporting under fading conditions – PUSCH 3-2 for eDL MIMO Enhancement

SNRs as specified

Limits as in the Test Procedure

Noc: -98dBm/15kHz

1.05

1.15

0dB

0.01

0.01

SNR unchanged

Noc: -98dBm/15kHz

1.04 as per Table G.5.4-1

1.14 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.3.7.2 TDD CQI Reporting under fading conditions – PUSCH 3-2 for eDL MIMO Enhancement

Same as 9.3.7.1

Same as 9.3.7.1

Same as 9.3.7.1

9.3.8.1.1

Noc: -98dBm/15kHz

SNR: +8.34dB

Cell 2 Ês/Noc: +3.28 dB

Cell 3 Ês/Noc: +0.74 dB

0.925

0 dB

+0.63 dB

+0.8 dB

+0.8 dB

0.01

Noc: -98dBm/15kHz

SNR: +8.97dB

Cell 2 Ês/Noc: +4.08 dB

Cell 3 Ês/Noc: +1.54 dB

0.915 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.3.8.1.2

Same as 9.3.8.1.1

Same as 9.3.8.1.1

Same as 9.3.8.1.1

9.3.8.2.1

Noc: -98dBm/15kHz

SNR: +8.34dB

Cell 2 Ês/Noc: +3.28 dB

Cell 3 Ês/Noc: +0.74 dB

0.925

0 dB

+0.63 dB

+0.8 dB

+0.8 dB

0.01

Noc: -98dBm/15kHz

SNR: +8.97dB

Cell 2 Ês/Noc: +4.08 dB

Cell 3 Ês/Noc: +1.54 dB

0.915 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.3.8.2.2

Same as 9.3.8.2.1

Same as 9.3.8.2.1

Same as 9.3.8.2.1

9.3.8.3.1 FDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM10 with TM9 interference – Enhanced Receiver Type B

Noc: -98dBm/15kHz

SNR: +8.34dB

Cell 2 Ês/Noc: +3.28 dB

Cell 3 Ês/Noc: +0.74 dB

0.925

0 dB

+0.63 dB

+0.8 dB

+0.8 dB

0.01

Noc: -98dBm/15kHz

SNR: +8.97dB

Cell 2 Ês/Noc: +4.08 dB

Cell 3 Ês/Noc: +1.54 dB

 0.915 as per Table G.5.4-1

9.3.8.3.2 TDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM10 with TM9 interference – Enhanced Receiver Type B

Same as 9.3.8.3.1

Same as 9.3.8.3.1

Same as 9.3.8.3.1

9.4.1.1.1 FDD PMI Reporting – PUSCH 3-1 (Single PMI)

1.10

0.01

1.09 as per Table G.5.4-1

9.4.1.1.2 TDD PMI Reporting – PUSCH 3-1 (Single PMI)

Same as 9.4.1.1.1

Same as 9.4.1.1.1

Same as 9.4.1.1.1

9.4.1.2.1 FDD PMI Reporting – PUCCH 2-1 (Single PMI)

Noc as specified in test procedure

1.2

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is reused unchanged as setting in procedure step 3.

1.19 as per Table G.5.4-1

9.4.1.2.2 TDD PMI Reporting – PUCCH 2-1 (Single PMI)

Same as 9.4.1.2.1

Same as 9.4.1.2.1

Same as 9.4.1.2.1

9.4.1.3.1_D FDD Reporting of PMI – PUSCH 3-1 (Single PMI) for eDL-MIMO

Same as 9.4.1.2.1

Same as 9.4.1.2.1

Same as 9.4.1.2.1

9.4.1.3.2_D TDD Reporting of PMI – PUSCH 3-1 (Single PMI) for eDL-MIMO

Same as 9.4.1.2.1

Same as 9.4.1.2.1

Same as 9.4.1.2.1

9.4.1.3.3 FDD PMI Reporting with 12Tx Class A codebook – PUSCH 3-1 (Single PMI) for FD-MIMO

Noc as specified in test procedure

2.50

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is used unchanged.

2.49 as per Table G.5.4-1

9.4.1.3.4 TDD PMI Reporting with 12Tx Class A codebook – PUSCH 3-1 (Single PMI) for FD-MIMO

Same as 9.4.1.3.3

Same as 9.4.1.3.3

Same as 9.4.1.3.3

9.4.1.4.1 FDD PMI Reporting with 4Tx enhanced codebook – PUCCH 1-1 (Single PMI) for eDL MIMO Enhancement 9.6.1.3.2, TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (3DL CA)

Noc: -98dBm/15kHz

1.8

0.01

Noc: -98dBm/15kHz

1.79 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.4.1.4.2 TDD PMI Reporting with 4Tx enhanced codebook – PUCCH 1-1 (Single PMI) for eDL MIMO Enhancement 9.6.1.4.2, TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (3DL CA)

Same as 9.4.1.4.1

Same as 9.4.1.4.1

Same as 9.4.1.4.1

9.4.1.4.3 FDD PMI Reporting with Class B alternative codebook – PUCCH 1-1 for FD-MIMO

Same as 9.4.1.3.3

Same as 9.4.1.3.3

Same as 9.4.1.3.3

9.4.1.4.4 TDD PMI Reporting with Class B alternative codebook – PUCCH 1-1 for FD-MIMO

Same as 9.4.1.3.3

Same as 9.4.1.3.3

Same as 9.4.1.3.3

9.4.2.1.1 FDD PMI Reporting – PUSCH 1-2 (Multiple PMI)

Noc as specified in test procedure

1.20

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is reused unchanged as setting in procedure step 3.

1.19 as per Table G.5.4-1

9.4.2.1.1_1 FDD PMI Reporting – PUSCH 1-2 (Multiple PMI)

Same as 9.4.2.1.1

Same as 9.4.2.1.1

Same as 9.4.2.1.1

9.4.2.1.2 TDD PMI Reporting – PUSCH 1-2 (Multiple PMI)

Same as 9.4.2.1.1

Same as 9.4.2.1.1

Same as 9.4.2.1.1

9.4.2.1.2_1 TDD PMI Reporting – PUSCH 1-2 (Multiple PMI)

Same as in 9.4.2.1.1

Same as in 9.4.2.1.1

Same as in 9.4.2.1.1

9.4.2.2.1 FDD PMI Reporting – PUSCH 2-2 (Multiple PMI)

Same as in 9.4.2.1.1

Same as in 9.4.2.1.1

Same as in 9.4.2.1.1

9.4.2.2.2 TDD PMI Reporting – PUSCH 2-2 (Multiple PMI)

Noc as specified in test procedure

1.15

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is reused unchanged as setting in procedure step 3.

1.14 as per Table G.5.4-1

9.4.2.3.1_D FDD PMI Reporting – PUSCH 1-2 (Multiple PMI) for eDL-MIMO

Noc as specified in test procedure

1.30

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is reused unchanged as setting in procedure step 3.

1.29 as per Table G.5.4-1

9.4.2.3.2_D TDD PMI Reporting – PUSCH 1-2 (Multiple PMI) for eDL-MIMO

Noc as specified in test procedure

3.50

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of an approach according to G.5.2 and is reused unchanged as setting in procedure step 3.

3.49 as per Table G.5.4-1

9.4.2.3.3 FDD PMI Reporting with 4Tx enhanced codebook – PUSCH 1-2 (Multiple PMI) for eDL-MIMO Enhancement

Noc: -98dBm/15kHz

1.2

0.01

Noc: -98dBm/15kHz

1.19 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.4.2.3.4 TDD PMI Reporting with 4Tx enhanced codebook – PUSCH 1-2 (Multiple PMI) for eDL-MIMO Enhancement

Same as 9.4.2.3.3

Same as 9.4.2.3.3

Same as 9.4.2.3.3

9.4.2.3.5 FDD PMI Reporting with Class A 16Tx codebook – PUSCH 1-2 (Multiple PMI) for FD-MIMO

Same as 9.4.1.3.3

Same as 9.4.1.3.3

Same as 9.4.1.3.3

9.4.2.3.6 TDD PMI Reporting with Class A 16Tx codebook – PUSCH 1-2 (Multiple PMI) for FD-MIMO

Same as 9.4.1.3.3

Same as 9.4.1.3.3

Same as 9.4.1.3.3

9.5.1.1 FDD RI Reporting– PUCCH 1-1

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 21.10

SNR 0dB

20.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

2 1.09 as per Table G.5.4-1

9.5.1.1_1 FDD RI Reporting– PUCCH 1-1 (Release 10)

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.90, 21.10

SNR 0dB

20.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89, 2 1.09 as per Table G.5.4-1

9.5.1.1_2 FDD RI Reporting– PUCCH 1-1 (Release 11)

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.90

SNR 0dB

20.01

10.01

10.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89 as per Table G.5.4-1

9.5.1.2 TDD RI Reporting– PUSCH 3-1

Same as 9.5.1.1

Same as 9.5.1.1

Same as 9.5.1.1

9.5.1.2_1 TDD RI Reporting– PUSCH 3-1 (Release 10)

Same as 9.5.1.1_1

Same as 9.5.1.1_1

Same as 9.5.1.1_1

9.5.1.2_2 TDD RI Reporting– PUSCH 3-1 (Release 11)

Same as 9.5.1.1_2

Same as 9.5.1.1_2

Same as 9.5.1.1_2

9.5.2.1_D FDD RI Reporting – PUCCH 1-1 for eDL-MIMO

SNR as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

SNR 0dB

20.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

10.89 as per Table G.5.4-1

9.5.2.2_D TDD RI Reporting – PUCCH 1-1 for eDL-MIMO

SNR as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

SNR 0dB

20.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

10.89 as per Table G.5.4-1

9.5.3.1_C.1 FDD RI Reporting – PUCCH 1-0 for eICIC (non-MBSFN ABS)

SNRs as specified

Test 1: 10.90

Test 2: 11.05

SNR 0dB

10.01

10.01

SNR unchanged

1 0.89 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.5.3.2_C.1 TDD RI Reporting – PUCCH 1-0 for eICIC (non-MBSFN ABS)

SNRs as specified

Test 1: 10.90

Test 2: 11.05

SNR 0dB

10.01

10.01

SNR unchanged

1 0.89 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.5.4.1_E.1 FDD RI Reporting – PUCCH 1-0 for feICIC (non-MBSFN ABS)

SNR as specified

Test 1: 21.05

Test 2: 11.05

Test 3: 10.9

SNR 0dB

20.01

10.01

10.01

SNR unchanged

2 1.04 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

10.89 as per Table G.5.4-1

The analysis is recorded in 3GPP TR 36.904 [17]

9.5.4.2_E.1 TDD RI Reporting – PUCCH 1-0 for feICIC (non-MBSFN ABS)

Same as 9.5.4.1_E.1

Same as 9.5.4.1_E.1

Same as 9.5.4.1_E.1

9.5.5.1_F.1 FDD RI Reporting with Single CSI process for CoMP

SNRs as specified

Test 1: 21.00

Test 2: 11.00

SNR 0dB

20.01

10.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 0.99 as per Table G.5.4-1

9.5.5.1_F.2 FDD RI Reporting with Multiple CSI processes for CoMP

SNRs as specified

Test 1: 21.00

Test 2: 11.00

SNR 20dB

20.01

10.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 0.99 as per Table G.5.4-1

9.5.5.2_F.1 TDD RI Reporting with Single CSI process for CoMP

Same as 9.5.5.1_F.1

Same as 9.5.5.1_F.1

Same as 9.5.5.1_F.1

9.5.5.2_F.2 TDD RI Reporting with Multiple CSI processes for CoMP

Same as 9.5.5.2_F.1

Same as 9.5.5.2_F.1

Same as 9.5.5.2_F.1

9.6.1.1_A.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (2DL CA)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR ratios each have an uncertainty of ±0.3 dB. For uncorrelated uncertainties, the overall uncertainty in the SNR difference between any two CCs would be SQRT (0.32 + 0.32) = 0.42dB. This could widen the Median CQI difference, but the uncertainty is significantly less than one reported CQI step. Relaxing the allowed Median CQI difference would relax the test excessively, so in this case the Test requirement should be left unchanged.

9.6.1.1_A.2 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 (3DL CA)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

Same as 9.6.1.1_A.1

9.6.1.1_A.4 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 (5DL CA)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

Same as 9.6.1.1_A.1

9.6.1.1_A.5 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 (6DL CA)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

Same as 9.6.1.1_A.1

9.6.1.1_A.6 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 (7DL CA)

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

Same as 9.6.1.1_A.1

9.6.1.2_A.1 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for 2DL CA

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

9.6.1.2_A.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 (3DL CA)

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

9.6.1.2_A.3 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 (4DL CA)

Same as 9.6.1.1_A.3

Same as 9.6.1.1_A.3

Same as 9.6.1.1_A.3

9.6.1.2_A.4 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 (5DL CA)

Same as 9.6.1.1_A.4

Same as 9.6.1.1_A.4

Same as 9.6.1.1_A.4

9.6.1.2_A.5 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 (6DL CA)

Same as 9.6.1.1_A.5

Same as 9.6.1.1_A.5

Same as 9.6.1.1_A.5

9.6.1.2_A.6 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 (7DL CA)

Same as 9.6.1.1_A.6

Same as 9.6.1.1_A.6

Same as 9.6.1.1_A.6

9.6.1.3.1 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (2DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

The analysis is recorded in 3GPP TR 36.904 [17]

9.6.1.3.2 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (3DL CA)

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

The analysis is recorded in 3GPP TR 36.904 [17]

9.6.1.3.3 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (4DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

9.6.1.3.4 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (5DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

9.6.1.4.1 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (2DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

The analysis is recorded in 3GPP TR 36.904 [17]

9.6.1.4.2 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (3DL CA)

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

Same as 9.6.1.1_A.2

The analysis is recorded in 3GPP TR 36.904 [17]

9.6.1.4.3 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (4DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

9.6.1.4.4 TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (5DL CA)

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

Same as 9.6.1.1_A.1

9.7.1.1 FDD and Half duplex FDD CQI reporting definition under AWGN conditions for UE category 0

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.7.1.2 TDD CQI reporting definition under AWGN conditions for UE category 0

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.7.2.1 FDD and Half duplex FDD CQI reporting definition under fading conditions for UE category 0

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.7.2.2 TDD CQI reporting definition under fading conditions for UE category 0

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.7_1.1.1 FDD CQI reporting under AWGN conditions – PUCCH 1-0 for UE category 1bis

Same as 9.2.1.1

Same as 9.2.1.1

Same as 9.2.1.1

9.7_1.1.2 TDD CQI reporting under AWGN conditions – PUCCH 1-0 for UE category 1bis

Same as 9.2.1.2

Same as 9.2.1.2

Same as 9.2.1.2

9.7_1.1.3 FDD CQI reporting under fading conditions – PUSCH 3-0 for UE category 1bis

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.7_1.1.4 TDD CQI reporting under fading conditions – PUSCH 3-0 for UE category 1bis

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.8.1.1 FDD and Half duplex FDD CQI reporting definition under AWGN conditions for UE category M1

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.8.1.2 TDD CQI reporting definition under AWGN conditions for UE category M1

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.8.2.1 FDD and Half duplex FDD CQI reporting definition under fading conditions for UE category M1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.8.2.2 TDD CQI reporting definition under fading conditions for UE category M1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

Same as 9.3.1.1.1

9.9.1.1.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-0 with Rank 1 1×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.1.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-0 with Rank 1 1×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.2.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 2 4×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.2.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 2 8×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.3.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 4 4×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.3.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 4 4×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.4.1 FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 3 4×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.1.4.2 TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 3 8×4

SNRs as specified

Limits as in the Test Procedure

No test tolerances applied

SNR and limits unchanged

9.9.2.1.1 FDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A 1×4

Noc: -98dBm/15kHz

DIP 1: -0.41dB

SINR: -4.00dB

1.8

BLER 0.02

0dB

+0.03dB

+0.03dB

0.01

Noc: -98dBm/15kHz

DIP 1: -0.38dB

SINR: -3.97dB

1.79 as per Table G.5.4-1

BLER limit unchanged

The analysis is recorded in 3GPP TR 36.904 [17]

9.9.2.1.2 TDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A 1×4

Same as 9.9.2.1.1

Same as 9.9.2.1.1

Same as 9.9.2.1.1

9.9.2.2.1 FDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A 2×4

Noc: -98dBm/15kHz

DIP 1: -0.41dB

SINR: -4.00dB

1.8

BLER 0.02

0dB

+0.03dB

+0.03dB

0.01

Noc: -98dBm/15kHz

DIP 1: -0.38dB

SINR: -3.97dB

1.79 as per Table G.5.4-1

BLER limit unchanged

The analysis is recorded in 3GPP TR 36.904 [17]

9.9.2.2.2 TDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A 2×4

Same as 9.9.2.2.1

Same as 9.9.2.2.1

Same as 9.9.2.2.1

9.9.3.1.1 TDD PMI Reporting – PUSCH 3-1 (Single PMI) 8×4

Noc as specified in test procedure

2.50

0.01

Noc unchanged

Ior/ Noc=SNRrnd is a result of test procedure step 2 and is used as setting in test procedure step 3.

2.49 as per Table G.5.4-1

9.9.4.1.1 FDD RI Reporting– PUCCH 1-1 4×4

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

Test 4: 2 1.10

SNR 0dB

20.01

10.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89 as per Table G.5.4-1

2 1.09 as per Table G.5.4-1

9.9.4.1.2 TDD RI Reporting– PUSCH 3-1 4×4

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

Test 4: 2 1.10

SNR 0dB

20.01

10.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89 as per Table G.5.4-1

2 1.09 as per Table G.5.4-1

9.9.4.2.1 FDD RI Reporting- PUCCH 1-1 for eDL-MIMO 1×4

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

Test 4: 2 1.10

SNR 0dB

20.01

10.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89 as per Table G.5.4-1

2 1.09 as per Table G.5.4-1

9.9.4.2.2 TDD RI Reporting- PUCCH 1-1 for eDL-MIMO 1×4

SNRs as specified

Test 1: 21.00

Test 2: 11.05

Test 3: 10.9

Test 4: 2 1.10

SNR 0dB

20.01

10.01

10.01

20.01

SNR unchanged

2 0.99 as per Table G.5.4-1

1 1.04 as per Table G.5.4-1

1 0.89 as per Table G.5.4-1

2 1.09 as per Table G.5.4-1

9.10.1.1 FDD CSI-RS Resource Indicator Reporting – PUSCH 3-1

SNRs as specified

Test 1-1: 1.2

Test 1-2: 1.2

Test 1-3: 1.3

Test 1-4: 1.35

SNR 0dB

0.01

SNR unchanged

1.19 as per Table G.5.4-1

1.19 as per Table G.5.4-1

1.29 as per Table G.5.4-1

1.34 as per Table G.5.4-1

9.10.1.2 TDD CSI-RS Resource Indicator Reporting – PUSCH 3-1

SNRs as specified

Test 1-1: 1.2

Test 1-2: 1.2

Test 1-3: 1.3

Test 1-4: 1.35

SNR 0dB

0.01

SNR unchanged

1.19 as per Table G.5.4-1

1.19 as per Table G.5.4-1

1.29 as per Table G.5.4-1

1.34 as per Table G.5.4-1

9.12.1.1 FDD CQI Reporting under fading conditions (with cell-specific reference symbols configured for UE supporting short TTI)

SNRs as specified

20%

1.05

BLER 0.02

SNR 0dB

0%

0.01

BLER 0

SNR and BLER limits unchanged

 limit unchanged

1.04 as per Table G.5.4-1

BLER limit unchanged

9.12.1.1 TDD CQI Reporting under fading conditions (with cell-specific reference symbols configured for UE supporting short TTI)

SNRs as specified

20%

1.05

BLER 0.02

SNR 0dB

0%

0.01

BLER 0

SNR and BLER limits unchanged

 limit unchanged

1.04 as per Table G.5.4-1

BLER limit unchanged

9.12.2.1 FDD CQI Reporting under fading conditions (with CSI reference symbols configured for UE supporting short TTI)

SNRs as specified

20%

1.05

BLER [0.02]

SNR 0dB

0%

0.01

BLER 0

SNR and BLER limits unchanged

 limit unchanged

1.04 as per Table G.5.4-1

BLER limit unchanged

9.12.2.2 FDD CQI Reporting under fading conditions (with CSI reference symbols configured for UE supporting short TTI)

SNRs as specified

20%

1.05

BLER [0.02]

SNR 0dB

0%

0.01

BLER 0

SNR and BLER limits unchanged

 limit unchanged

1.04 as per Table G.5.4-1

BLER limit unchanged

Annex G (normative):
Statistical Testing