7.7E Spurious response for UE category 0
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
7.7E.1 Test Purpose
Same test purpose as in clause 7.7.1.
7.7E.2 Test Applicability
This test applies to all types of E-UTRA UE release 12 and forward of UE category 0.
7.7E.3 Minimum Conformance Requirements
Same minimum conformance requirements as in clause 7.7.3.
7.7E.4 Test Description
7.7E.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2E.4.1 in order to test spurious responses obtained in clause 7.6.2E under the same conditions.
7.7E.4.2 Test Procedure
Same test procedure as in clause 7.7.4.2
7.7E.4.3 Message Contents
Same message contents as in clause 7.7.4.3
7.7E.5 Test Requirement
The throughput measurement derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Tables 7.7E.5-1 and 7.7E.5-2.
Table 7.7E.5-1: Spurious response parameters
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7E.5-2: Spurious Response
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |