7.7A Spurious response for CA
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
7.7A.0 Minimum conformance requirements
For inter-band carrier aggregation with one component carrier per operating band and the uplink assigned to one E-UTRA band the spurious response requirements are defined with the uplink active on the band(s) other than the band whose downlink is being tested. The throughput measured in each downlink with Finterferer in Table 7.6.2A.0-0 and Table 7.6.2A.0-0a at spurious response frequencies shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.7.3-1 and 7.7.3-2. The UE shall meet these requirements for each component carrier while all downlink carriers are active.
For inter-band carrier aggregation with one component carrier per operating band and the uplink active in two E-UTRA bands, the spurious response requirements applicable specified above shall be met with the transmitter power for the uplink set to 7 dB below PCMAX_L,c for each serving cell c.
For E-UTRA CA configurations including an operating band without uplink band or an operating band with an unpaired DL part (as noted in Table 5.2-1), the requirements for all downlinks shall be met with the single uplink active in each band capable of UL operation. For E-UTRA CA configurations listed in Table 7.3A.0-0a under conditions for which reference sensitivity for the operating band being tested is N/A, the spurious response requirements of subclause 7.7A.0 do not apply.
For intra-band contiguous carrier aggregation the downlink SCC(s) shall be configured at nominal channel spacing to the PCC. For FDD, the PCC shall configure closest to the uplink band. All downlink carriers shall be active throughout the test. The uplink output power shall be set as specified in Table 7.7A.0-1 with the uplink configuration set according to Table 7.3A.0-1 for the applicable carrier aggregation configuration. For UE(s) supporting one uplink carrier, the uplink configuration of the PCC shall be in accordance with Table 7.3.3-2. The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.7A.0-1 and 7.7A.0-2. For operating bands with an unpaired DL part (as noted in Table 5.2-1), the requirements also apply for an SCC assigned in the unpaired part with parameters specified in Tables 7.7A.0-1 and 7.7A.0-2.
For intra-band non-contiguous carrier aggregation with one uplink carrier and two or more downlink sub-blocks, the spurious response requirements are defined with the uplink configuration in accordance with Table 7.3A.0-3. For this uplink configuration, the UE shall meet the requirements for each sub-block as specified in subclauses 7.7.3 and 7.7A.0 for one component carrier and two component carriers per sub-block, respectively. The requirements apply with all downlink carriers active.
For intra-band non-contiguous carrier aggregation with two uplink carriers and two downlink carriers, the spurious response requirements applicable specified above shall be met with the transmitter powers for the uplinks set to PCMAX_L,c – 7 dBm.
Table 7.7A.0-1: Spurious response parameters
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
9 |
||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5A. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.0-2: Spurious response
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
For combinations of intra-band and inter-band carrier aggregation with up to five downlink carriers (up to two non-contiguously sub-blocks per band and up to four contiguously aggregated carriers per band) and one uplink carrier assigned to one E-UTRA band, the requirement is defined with the uplink active in a band other than that supporting the downlink(s) under test. The uplink configuration shall be in accordance with Table 7.3A.0-3 when the uplink is active in the band supporting two non-contiguous component carriers, Table 7.3A.0-1 when the uplink is active in a band supporting two contiguous component carriers and in accordance with Table 7.3.3-2 when the uplink is active in a band supporting one carrier per band. The downlink PCC shall be configured closer to the uplink operating band than the downlink SCC(s) when the uplink is active in band(s) supporting contiguous aggregation of up to four component carriers. For the two non-contiguous component carriers within the same band, Pwanted in Table 7.6.2A.0-0 is set using RIBNC = 0 dB for all sub-block gaps (Table 7.3A.0-3) while a band supporting contiguously aggregated carriers the out-of-band blocking parameters in Table 7.7.3-1 are replaced by those specified in Table 7.7A.0-1. For each downlink the UE shall meet the spurious-response requirements applicable for inter-band carrier aggregation with one component carrier per operating band but with up to three component carriers assigned to the same band. All downlink carriers shall be active throughout the tests and the requirements for the downlinks shall be met with the single uplink carrier active in each band capable of UL operation.
The normative reference for this requirement is TS 36.101 [2] clause 7.7.1A.
7.7A.1 Spurious response for CA (intra-band contiguous DL CA and UL CA)
7.7A.1.1 Test Purpose
Spurious response for CA verifies the receiver’s ability to receive a wanted aggregated signal on its assigned channel frequency without exceeding a given degradation due to the presence of an unwanted CW interfering signal at any other frequency at which a response is obtained i.e. for which the out of band blocking limit as specified in sub-clause 7.6.2A is not met.
The lack of the spurious response ability decreases the coverage area when other unwanted interfering signal exists at any other frequency.
7.7A.1.2 Test Applicability
This test applies to all types of E-UTRA UE release 10 and forward that support intra-band contiguous DL CA and UL CA.
7.7A.1.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.1.4 Test Description
7.7A.1.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.1.4.1 in order to test spurious responses obtained in clause 7.6.2A.1 under the same conditions.
7.7A.1.4.2 Test Procedure
1. Configure SCC according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCC as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.1.4.3.
3. SS activates SCC by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.1.4.1-1 on both PCC and SCC. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.1.4.1-1 on both PCC and SCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.1.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.1.4.2.
7. Set the downlink signal level according to the table 7.7A.1.5-1 for both carriers. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that for at least the duration of the throughput measurement:
The PCC output power is within (+0dB, -3.4 dB) of (target level in Table 7.7A.1.5-1 + 10log(P_LCRB/NRB_alloc)), for carrier frequency f ≤ 3.0GHz,
or within (+0dB, -4 dB) of (target level in Table 7.7A.1.5-1 + 10log(P_LCRB/NRB_alloc)) for carrier frequency 3.0GHz < f ≤ 4.2GHz.
The SCC output power is within (+0dB, -3.4 dB) of (target level in Table 7.7A.1.5-1 + 10log(S_LCRB/NRB_alloc)), for carrier frequency f ≤ 3.0GHz,
or within (+0dB, -4 dB) of (target level in Table 7.7A.1.5-1 + 10log(S_LCRB/NRB_alloc)) for carrier frequency 3.0GHz < f ≤ 4.2GHz.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.1.4.3 Message Contents
Message contents are according to TS 36.508 [7] subclause 4.6 with the following exception.
Table 7.7A.1.4.3-1: UplinkPowerControlDedicated
Derivation Path: 36.331 clause 6.3.2 |
|||
Information Element |
Value/remark |
Comment |
Condition |
UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE { |
|||
p0-UePUSCH |
0 |
||
deltaMCS-Enabled |
en0 |
||
accumulationEnabled |
TRUE |
||
p0-uePUCCH |
0 |
||
pSRS-Offset |
3 (-6 dB) |
||
filterCoefficient |
fc8 |
larger filter length is used to reduce the RSRP measurement variation |
|
} |
Table 7.7A.1.4.3-2: UplinkPowerControlDedicatedSCell-r10
Derivation Path: 36.508 clause 4.6.3 |
|||
Information Element |
Value/remark |
Comment |
Condition |
UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE { |
|||
p0-UE-PUSCH-r10 |
0 |
||
deltaMCS-Enabled-r10 |
en0 |
||
accumulationEnabled-r10 |
TRUE |
||
pSRS-Offset-r10 |
7 (0 dB) |
The actual parameter value is -10.5 + 1.5*pSRS-Offset value; 0 is the actual value in dB (-10.5 + 1.5*7 dB). |
|
pSRS-OffsetAp-r10 |
7 (0 dB) |
The actual parameter value is -10.5 + 1.5*pSRS-Offset value; 0 is the actual value in dB (-10.5 + 1.5*7 dB). |
|
filterCoefficient-r10 |
fc8 |
larger filter length is used to reduce the RSRP measurement variation |
|
pathlossReferenceLinking-r10 |
sCell |
||
} |
7.7A.1.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.7A.1.5-1 and 7.7A.1.5-2.
Table 7.7A.1.5-1: Spurious response parameters
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
|||||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5 for one uplink carrier and in subclause 6.2.5A for two uplink carriers. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.1.5-2: Spurious response
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
For the UE which supports inter band CA configuration in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, PInterferer power defined in Table 7.7A.1.5-2 is increased by the amount given by ΔRIB,c in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.
7.7A.2 Spurious response for CA (intra-band contiguous DL CA without UL CA)
7.7A.2.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.2.2 Test Applicability
This test applies to all types of E-UTRA UE release 10 and forward that support intra-band contiguous DL CA. This test case applies only for CA configurations that do not support UL CA.
7.7A.2.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.2.4 Test Description
7.7A.2.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.2.4.1 in order to test spurious responses obtained in clause 7.6.2A.2 under the same conditions.
7.7A.2.4.2 Test Procedure
1. Configure SCC according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCC as per TS 36.508 [7] clause 5.2A.4.
3. SS activates SCC by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.2.4.1-1 on both PCC and SCC. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.2.4.1-1 on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.1.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.2.4.2.
7. Set the downlink signal level according to the table 7.7A.1.5-1 for both carriers. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in table 7.7A.1.5-1 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.2.4.3 Message Contents
Same message contents as in clause 7.7.4.3.
7.7A.2.5 Test Requirement
Same test requirement as in clause 7.7A.1.5 with the following exceptions :
– Instead of Table 7.7A.1.5-1 🡪 use Table 7.7A.2.5-1.
Table 7.7A.2.5-1: Spurious response parameters
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
|||||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
7.7A.3 Spurious response for CA (inter-band DL CA without UL CA)
7.7A.3.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.3.2 Test Applicability
This test applies to all types of E-UTRA UE release 10 and forward that support inter-band DL CA.
This test case also applies to all types of E-UTRA UE release 12 and forward that support 2DL CA with FDD-TDD inter-band CA.
This test case also applies to all types of E-UTRA UE release 13 and forward that support DL LAA.
This test case applies only for CA configurations that do not support UL CA.
7.7A.3.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.3.4 Test Description
7.7A.3.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.3.4.1 in order to test spurious responses obtained in clause 7.6.2A.3 under the same conditions.
7.7A.3.4.2 Test Procedure
1. Configure SCC according to Annex C0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCC as per TS 36.508 [7] clause 5.2A.4.
3. SS activates SCC by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.3.4.1-1 on both PCC and SCC. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.3.4.1-1 on PCC. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.3.5-2. The spurious frequencies are taken from records in the step 9 of test procedures in clause 7.6.2A.3.4.2.
7. Set the downlink signal level according to the table 7.7A.3.5-1 for both carriers. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in table 7.7A.3.5-1 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput of SCC for duration sufficient to achieve statistical significance according to Annex G.2.
7.7A.3.4.3 Message Contents
Same message contents as in clause 7.7.4.3.
7.7A.3.5 Test Requirement
For inter-band carrier aggregation with uplink assigned to one E-UTRA band the spurious response requirements are defined with the uplink active on the band other than the band whose downlink is being tested i.e. the requirements are tested only for the SCell downlink. The UE shall meet the requirement for each component carrier, when operated as SCell, while both downlink carriers are active.
The throughput measured during the test procedure for each component carrier, when operated as SCell, shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.7A.3.5-1 (originated from the single carrier Table 7.7.5-1) and 7.7A.3.5-2 (originated from Table 7.6.2A.3.5-2).
Table 7.7A.3.5-1: Spurious response parameters
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.3.5-2: Spurious Response
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
For the UE which supports inter band CA configuration in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, Puw power defined in Table 7.7A.3.5-2 is increased by the amount given by ΔRIB,c in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.
7.7A.4 Spurious response for CA (intra-band non-contiguous DL CA without UL CA)
7.7A.4.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.4.2 Test Applicability
This test applies to all types of E-UTRA UE release 11 and forward that support intra-band non-contiguous DL CA. This test case applies only for CA configurations that do not support UL CA.
7.7A.4.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.4.4 Test Description
7.7A.4.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.4.4.1 in order to test spurious responses obtained in clause 7.6.2A.4 under the same conditions.
7.7A.4.4.2 Test Procedure
1. Configure SCC according to Annex C0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCC as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.4.4.3.
3. SS activates SCC by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.4.4.1-1 on both PCC and SCC. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.4.4.1-1 on PCC. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal below or above the wanted aggregated signal according to Table 7.7A.4.5-2. The spurious frequencies are taken from records in the step 9 of test procedures in clause 7.6.2A.4.4.2.
7. Set the downlink signal level according to the table 7.7A.4.5-1 for both carriers. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in table 7.7A.4.5-1 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput of each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.4.4.3 Message Contents
Same message contents as in clause 7.7.4.3.
7.7A.4.5 Test Requirement
For intra-band non-contiguous carrier aggregation with one uplink carrier and two downlink carriers, the spurious response requirements are defined with the uplink configuration of the PCC being in accordance with Table 7.3A.0-3. The UE shall meet the requirements specified in tables 7.7A.4.5-1and 7.7A.4.5-2 for each component carrier while both downlink carriers are active.
The requirements for each component carrier are the same as single carrier requirements in Tables 7.7.5-1 and 7.7.5-2.
Table 7.7A.4.5-1: Spurious response parameters
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.4.5-2: Spurious Response
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
For the UE which supports inter band CA configuration in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, Puw power defined in Table 7.7A.4.5-2 is increased by the amount given by ΔRIB,c in Table 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.
7.7A.5 Spurious response for 3DL CA
7.7A.5.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.5.2 Test Applicability
This test case applies to all types of E-UTRA UE and forward that support 3DL with CA configurations in Table 7.1-2a.
This test case also applies to all types of E-UTRA UE release 13 and forward that support 3DL CA involving Band 46.
7.7A.5.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.5.4 Test Description
7.7A.5.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.5.4.1 in order to test spurious responses obtained in clause 7.6.2A.5 under the same conditions.
7.7A.5.4.2 Test Procedure
1. Configure SCCs according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCCs as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.5.4.3
3. SS activates SCCs by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.5.4.1-1 through Table 7.6.2A.5.4.1-2 as appropriate on PCC and SCCs. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.5.4.1-1 through Table 7.6.2A.5.4.1-2 on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.5.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.5.4.2.
7. Set the downlink signal level according to the tables 7.7A.5.5-1 and 7.7A.5.5-3 for all carriers accordingly. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in corresponding tables 7.7A.5.5-1 and 7.7A.5.5-3 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.5.4.3 Message Contents
Same message contents as in clause 7.7.4.3 for without UL CA.
Same message contents as in clause 7.7A.1.4.3 for UL CA.
7.7A.5.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table s below, according to the type of CA.
Table 7.7A.5.5-1: Spurious response parameters (Intra-band contiguous)
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Power per CC in Aggregated Transmission Bandwidth Configuration |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
||||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.5.5-2: Spurious response (All types of CA)
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
Table 7.7A.5.5-3: Spurious response parameters (Inter-band, Intra-band non-contiguous)
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration for each CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. Note 3: For intra-band non-contiguous + inter-band CA, RIBNC = 0 dB for all sub-block gaps. |
For a UE, which supports CA configuration in Tables 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, Puw power defined in Table 7.7A.5.5-2 is increased by the amount given by ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.
7.7A.6
7.7A.7 Spurious response for 4DL CA
7.7A.7.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.7.2 Test Applicability
This test case applies to all types of E-UTRA UE and forward that support 4DL with CA configurations in Table 7.1-2b.
7.7A.7.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.7.4 Test Description
7.7A.7.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.7.4.1 in order to test spurious responses obtained in clause 7.6.2A.7 under the same conditions.
7.7A.7.4.2 Test Procedure
1. Configure SCCs according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCCs as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.7.4.3.
3. SS activates SCCs by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.7.4.1-1 through Table 7.6.2A.7.4.1-2 as appropriate on PCC and SCCs. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.7.4.1-1 through Table 7.6.2A.7.4.1-2 on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.7.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.7.4.2.
7. Set the downlink signal level according to the tables 7.7A.7.5-1 and 7.7A.7.5-3 for all carriers accordingly. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in corresponding tables 7.7A.7.5-1 and 7.7A.7.5-3 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.7.4.3 Message Contents
Same message contents as in clause 7.7.4.3 for without UL CA.
Same message contents as in clause 7.7A.1.4.3 for UL CA.
7.7A.7.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table s below, according to the type of CA.
Table 7.7A.7.5-1: Spurious response parameters (Intra-band contiguous)
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Power per CC in Aggregated Transmission Bandwidth Configuration |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5A. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.7.5-2: Spurious response (All types of CA)
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
Table 7.7A.7.5-3: Spurious response parameters (Inter-band, Intra-band non-contiguous)
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration for each CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. Note 3: For intra-band non-contiguous + inter-band CA, RIBNC = 0 dB for all sub-block gaps. |
For a UE, which supports CA configuration in Tables 7.3.3-1A, 7.3.3-1B and 7.3.3-1C, Puw power defined in Table 7.7A.7.5-2 is increased by the amount given by ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B and 7.3.3-1C.
7.7A.8 Spurious response for 5DL CA
7.7A.8.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.8.2 Test Applicability
This test case applies to all types of E-UTRA UE and forward that support 5DL with CA configurations in Table 7.1-2c.
7.7A.8.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.8.4 Test Description
7.7A.8.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.8.4.1 in order to test spurious responses obtained in clause 7.6.2A.8 under the same conditions.
7.7A.8.4.2 Test Procedure
1. Configure SCCs according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCCs as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.8.4.3.
3. SS activates SCCs by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.8.4.1-1 through Table FFS as appropriate on PCC and SCCs. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.8.4.1-1 through Table FFS on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.8.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.8.4.2.
7. Set the downlink signal level according to the tables 7.7A.8.5-1 and 7.7A.8.5-3 for all carriers accordingly. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in corresponding tables 7.7A.8.5-1 and 7.7A.8.5-3 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.8.4.3 Message Contents
Same message contents as in clause 7.7.4.3 for without UL CA.
Same message contents as in clause 7.7A.1.4.3 for UL CA.
7.7A.8.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table s below, according to the type of CA.
Table 7.7A.8.5-1: Spurious response parameters (Intra-band contiguous)
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Power per CC in Aggregated Transmission Bandwidth Configuration |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
9 |
||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5A. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.8.5-2: Spurious response (All types of CA)
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
Table 7.7A.8.5-3: Spurious response parameters (Inter-band, Intra-band non-contiguous)
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration for each CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. Note 3: For intra-band non-contiguous + inter-band CA, RIBNC = 0 dB for all sub-block gaps. |
For a UE, which supports CA configuration in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D, Puw power defined in Table 7.7A.8.5-2 is increased by the amount given by ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D.
7.7A.9 Spurious response for 6DL CA
7.7A.9.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.9.2 Test Applicability
This test case applies to all types of E-UTRA UE and forward that support 6DL with CA configurations in Table 7.1-2d.
7.7A.9.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.9.4 Test Description
7.7A.9.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.9.4.1 in order to test spurious responses obtained in clause 7.6.2A.9 under the same conditions.
7.7A.9.4.2 Test Procedure
1. Configure SCCs according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCCs as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.9.4.3.
3. SS activates SCCs by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.9.4.1-1 through Table FFS as appropriate on PCC and SCCs. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.9.4.1-1 through Table FFS on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.9.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.9.4.2.
7. Set the downlink signal level according to the tables 7.7A.9.5-1 and 7.7A.9.5-3 for all carriers accordingly. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in corresponding tables 7.7A.9.5-1 and 7.7A.9.5-3 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.9.4.3 Message Contents
Same message contents as in clause 7.7.4.3 for without UL CA.
Same message contents as in clause 7.7A.1.4.3 for UL CA.
7.7A.9.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table s below, according to the type of CA.
Table 7.7A.9.5-1: Spurious response parameters (Intra-band contiguous)
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Power per CC in Aggregated Transmission Bandwidth Configuration |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
9 |
||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5A. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.9.5-2: Spurious response (All types of CA)
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
Table 7.7A.9.5-3: Spurious response parameters (Inter-band, Intra-band non-contiguous)
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration for each CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. Note 3: For intra-band non-contiguous + inter-band CA, RIBNC = 0 dB for all sub-block gaps. |
For a UE, which supports CA configuration in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D, Puw power defined in Table 7.7A.9.5-2 is increased by the amount given by ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D.
7.7A.10 Spurious response for 7DL CA
7.7A.10.1 Test Purpose
Same test purpose as in clause 7.7A.1.
7.7A.10.2 Test Applicability
This test case applies to all types of E-UTRA UE and forward that support 7DL with CA configurations in Table 7.1-2e.
7.7A.10.3 Minimum Conformance Requirements
The minimum conformance requirements are defined in clause 7.7A.0.
7.7A.10.4 Test Description
7.7A.10.4.1 Initial Conditions
The initial conditions shall be the same as in clause 7.6.2A.10.4.1 in order to test spurious responses obtained in clause 7.6.2A.10 under the same conditions.
7.7A.10.4.2 Test Procedure
1. Configure SCCs according to Annex C.0, C.1 and Annex C.3.1 for all downlink physical channels.
2. The SS shall configure SCCs as per TS 36.508 [7] clause 5.2A.4. Message contents are defined in clause 7.7A.10.4.3.
3. SS activates SCCs by sending the activation MAC-CE (Refer TS 36.321 [13], clauses 5.13, 6.1.3.8). Wait for at least 2 seconds (Refer TS 36.133, clauses 8.3.3.2).
4. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.6.2A.10.4.1-1 on PCC and SCCs. The SS sends downlink MAC padding bits on the DL RMC.
5. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 7.6.2A.10.4.1-1 on PCC. Since the UE has no payload data to send, the UE sends uplink MAC padding bits on the UL RMC.
6. Set the parameters of the CW signal generator for an interfering signal according to Table 7.7A.10.5-2. The spurious frequencies are taken from records in the final step of test procedures in clause 7.6.2A.10.4.2.
7. Set the downlink signal level according to the tables 7.7A.10.5-1 and 7.7A.10.5-3 for all carriers accordingly. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in corresponding tables 7.7A.10.5-1 and 7.7A.10.5-3 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
8. For each spurious frequency, measure the average throughput for each component carrier for duration sufficient to achieve statistical significance according to Annex G.2A.
7.7A.10.4.3 Message Contents
Same message contents as in clause 7.7.4.3 for without UL CA.
Same message contents as in clause 7.7A.1.4.3 for UL CA.
7.7A.10.5 Test Requirement
The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table s below, according to the type of CA.
Table 7.7A.10.5-1: Spurious response parameters (Intra-band contiguous)
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Power per CC in Aggregated Transmission Bandwidth Configuration |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
9 |
||
Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5A. Note 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |
Table 7.7A.10.5-2: Spurious response (All types of CA)
Parameter |
Unit |
Level |
PInterferer (CW) |
dBm |
-44 |
FInterferer |
MHz |
Spurious response frequencies |
Table 7.7A.10.5-3: Spurious response parameters (Inter-band, Intra-band non-contiguous)
Rx Parameter |
Units |
Channel bandwidth |
||||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
Power in Transmission Bandwidth Configuration for each CC |
dBm |
REFSENS + channel bandwidth specific value below |
||||||
6 |
6 |
6 |
6 |
7 |
9 |
|||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: The reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. Note 3: For intra-band non-contiguous + inter-band CA, DRIBNC = 0 dB for all sub-block gaps. |
For a UE, which supports CA configuration in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D, Puw power defined in Table 7.7A.10.5-2 is increased by the amount given by ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B, 7.3.3-1C and 7.3.3-1D.