7.6.3EA Narrow band blocking for UE Category M1
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
7.6.3EA.1 Test Purpose
Verifies a receiver’s ability to receive an E-UTRA signal at its assigned channel frequency in the presence of an unwanted narrow band CW interferer at a frequency, which is less than the nominal channel spacing.
The lack of narrow-band blocking ability will decrease the coverage area when other e-NodeB transmitters exist (except in the adjacent channels and spurious response).
7.6.3EA.2 Test Applicability
This test applies to all types of E-UTRA UE release 13 and forward of UE category M1.
7.6.3EA.3 Minimum Conformance Requirements
The relative throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.6.3EA.3-1. For operating bands with an unpaired DL part (as noted in Table 5.2-1), the requirements only apply for carriers assigned in the paired part.
Table 7.6.3EA.3-1: Narrow-band blocking
Parameter |
Unit |
Channel Bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Pw |
dBm |
PREFSENS + channel-bandwidth specific value below |
|||||
22 |
18 |
16 |
13 |
14 |
16 |
||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
-55 |
-55 |
Fuw (offset for f = 15 kHz) |
MHz |
0.9075 |
1.7025 |
2.7075 |
5.2125 |
7.7025 |
10.2075 |
Fuw (offset for f = 7.5 kHz) |
MHz |
||||||
NOTE 1: The transmitter shall be set a 4 dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3EA-3 with PCMAX_L as defined in subclause 6.2.5EA. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. NOTE 3: For DL category M1 UE, the reference sensitivity for category M1 in table 7.3EA-1 and 7.3EA-2should be used as PREFSENS for Pw. NOTE 4: For DL category M1 UE, the parameters for the applicable channel bandwidth apply. |
The normative reference for this requirement is TS 36.101 [2] clause 7.6.3.
7.6.3EA.4 Test Description
7.6.3EA.4.1 Initial Conditions
Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.
The initial test configurations consist of environmental conditions and test frequencies based on the subset of E-UTRA operating bands defined for CAT M1 in clause 5.2E. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 7.6.1EA.4.1-1. The details of the downlink and uplink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3. The details of the OCNG patterns used are specified in Annex A.5. Configurations of PDSCH and MPDCCH before measurement are specified in Annex C.2.
Table 7.6.3EA.4.1-1: Test Configuration Table
Initial Conditions |
|||||||
Test Environment as specified in TS 36.508[7] subclause 4.1 |
NC |
||||||
Test Frequencies as specified in TS36.508 [7] subclause 4.3.1 |
Mid range |
||||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
5MHz |
||||||
Test Parameters for Channel Bandwidths and Narrowband positions |
|||||||
Downlink Configuration |
Uplink Configuration |
||||||
Ch BW |
Mod’n |
RB allocation |
Mod’n |
RB allocation |
|||
FDD |
TDD |
FDD and HD-FDD |
TDD |
Narrowband index (Note 1) |
|||
5MHz |
QPSK |
4 |
4 |
QPSK |
6 |
6 |
0 |
Note 1: Denotes where in the channel Bandwidth the narrowband shall be placed. Narrowband and Narrowband index are defined in TS36.211, 5.2.4. |
1. Connect the SS to the UE antenna connectors as shown in TS 36.508[7] Annex A Figure A.5 using only main UE Tx/Rx antenna.
2. The parameter settings for the cell are set up according to TS 36.508 [7] subclause 4.4.3.
3. Downlink signals are initially set up according to Annex C0, C.1 and C.3.1, and uplink signals according to Annex H.1 and H.3.1
4. The UL and DL Reference Measurement channels are set according to Table 7.6.3EA.4.1-1.
5. Propagation conditions are set according to Annex B.0.
6. Ensure the UE is in State 3A-RF-CE according to TS 36.508 [7] clause 5.2A.2AA. Message contents are defined in clause 7.6.3EA.4.3.
7.6.3EA.4.2 Test Procedure
1. SS transmits PDSCH via MPDCCH DCI format 6-1A for C_RNTI to transmit the DL RMC according to Table 7.6.1EA.4.1-1. The SS sends downlink MAC padding bits on the DL RMC. The SS sends one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1.
2. SS sends uplink scheduling information for each UL HARQ process via MPDCCH DCI format 6-0A for C_RNTI to schedule the UL RMC according to Table 7.6.3EA.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.
3. Set the parameters of the CW signal generator for an interfering signal below the wanted signal according to Table 7.6.3EA.5-1.
4. Set the downlink signal level according to the table 7.6.3EA.5-1. Send uplink power control commands to the UE (less or equal to 1dB step size should be used), to ensure that the UE output power is within +0, – 3.4 dB of the target level in table 7.6.3EA.5-1 for carrier frequency f ≤ 3.0GHz or within +0, -4.0 dB of the target level for carrier frequency 3.0GHz < f ≤ 4.2GHz, for at least the duration of the throughput measurement.
5. Measure the average throughput for a duration sufficient to achieve statistical significance according to Annex G.2.
6. Repeat steps from 3 to 5, using an interfering signal above the wanted signal at step 3.
7.6.3EA.4.3 Message Contents
Message contents are according to TS 36.508 [7] subclause 4.6 with the condition CEModeA and the following exception.
Table 7.6.3EA.4.3-1: UplinkPowerControlDedicated
Derivation Path: 36.331 clause 6.3.2 |
|||
Information Element |
Value/remark |
Comment |
Condition |
UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE { |
|||
p0-UE-PUSCH |
0 |
||
deltaMCS-Enabled |
en0 |
||
accumulationEnabled |
TRUE |
||
p0-UE-PUCCH |
0 |
||
pSRS-Offset |
3 (-6 dB) |
||
filterCoefficient |
fc8 |
larger filter length is used to reduce the RSRP measurement variation |
|
} |
7.6.3EA.5 Test Requirement
The throughput measurement derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.6.3EA.5-1.
Table 7.6.3EA.5-1: Narrow-band blocking
Parameter |
Unit |
Channel Bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Pw |
dBm |
PREFSENS + channel-bandwidth specific value below |
|||||
22 |
18 |
16 |
13 |
14 |
16 |
||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
-55 |
-55 |
Fuw (offset for f = 15 kHz) |
MHz |
0.9075 |
1.7025 |
2.7075 |
5.2125 |
7.7025 |
10.2075 |
Fuw (offset for f = 7.5 kHz) |
MHz |
||||||
NOTE 1: The transmitter shall be set a 4 dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3EA-3 with PCMAX_L as defined in subclause 6.2.5EA. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. NOTE 3: For DL category M1 UE, the reference sensitivity for category M1 in table 7.3EA-1 and 7.3EA-2 should be used as PREFSENS for Pw. NOTE 4: For DL category M1 UE, the parameters for the applicable channel bandwidth apply. |