7.6.1EB In-band blocking for UE Category 1bis

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

7.6.1EB.1 Test Purpose

The same test purpose as in clause 7.6.1.

7.6.1EB.2 Test Applicability

This test applies to all types of E-UTRA UE release 13 and forward of UE category 1bis.

7.6.1EB.3 Minimum Conformance Requirements

Same minimum conformance requirements as in clause 7.6.1.3.

7.6.1EB.4 Test Description

7.6.1EB.4.1 Initial Conditions

Same initial conditions as in clause 7.6.1.4.1 with the following exceptions:

Connect the SS to the UE antenna connectors as shown in TS 36.508[7] Annex A Figure A.4 using only main UE Tx/Rx antenna.

7.6.1EB.4.2 Test Procedure

Same test procedure as in clause 7.6.1.4.2

7.6.1EB.4.3 Message Contents

Same message contents as in clause 7.6.1.4.3

7.6.1EB.5 Test Requirement

The throughput measurement derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in clause A.3.2 with parameters specified in Tables 7.6.1EB.5-1 and 7.6.1EB.5-2.

Table 7.6.1EB.5-1: In band blocking parameters

Rx Parameter

Units

Channel bandwidth

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Power in Transmission Bandwidth Configuration

dBm

REFSENS + channel bandwidth specific value below

6

6

6

6

7

9

BWInterferer

MHz

1.4

3

5

5

5

5

FIoffset, case 1

MHz

2.1+0.0125

4.5+0.0075

7.5+0.0125

7.5+0.0025

7.5+0.0075

7.5+0.0125

FIoffset, case 2

MHz

3.5+0.0075

7.5+0.0075

12.5+0.0075

12.5+0.0125

12.5+0.0025

12.5+0.0075

Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5E.

Note 2: The interferer consists of the Reference measurement channel specified in clause A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in clauses A.5.1.1/A.5.2.1 and set-up according to clause C.3.1.

Note 3: The REFSENS power level is specified in Table 7.3EB.3-1 for main antenna port.

Table 7.6.1EB.5-2: In-band blocking

E-UTRA band

Parameter

Unit

Case 1

Case 2

Case 3

Case 4

Case 5

PInterferer

dBm

-56

-44

Void

Void

-38

FInterferer (offset)

MHz

=-BW/2 – FIoffset,case 1

&

=+BW/2 + FIoffset,case 1

≤-BW/2 – FIoffset,case 2

&

≥+BW/2 + FIoffset,case 2

-BW/2 – 11

1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 18, 26, 28, 31, 34, 39, 40, 41, 66, 72

FInterferer

MHz

(Note 2)

FDL_low – 15

to

FDL_high + 15

NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band.

NOTE 2: For each carrier frequency the requirement is valid for two frequencies:

a. the carrier frequency -BW/2 – FIoffset, case 1 and

b. the carrier frequency +BW/2 + FIoffset, case 1.

NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer centre frequencies.