7.4EB Maximum input level for UE Category 1bis
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
7.4EB.1 Test purpose
Same test purpose as in clause 7.4.1.
7.4EB.2 Test applicability
This test applies to all types of E-UTRA UE release 13 and forward of UE category 1bis.
7.4EB.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 7.4.3.
7.4EB.4 Test description
7.4EB.4.1 Initial conditions
Same initial conditions as in clause 7.4.4.1 with the following exceptions:
– Connect the SS to the UE antenna connectors as shown in TS 36.508[7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
7.4EB.4.2 Test procedure
Same test procedure as in clause 7.4.4.2.
7.4EB.4.3 Message contents
Same message contents as in clause 7.4.4.3.
7.4EB.5 Test requirement
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.4EB.5-1.
Table 7.4EB.5-1: Maximum input level
Rx Parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
For carrier frequency f ≤ 3.0GHz: -25.7 For carrier frequency 3.0GHz < f ≤ 4.2GHz: -26.0 |
|||||
Note 1: The transmitter shall be set to 4dB below PCMAX_L with PCMAX_L as defined in clause 6.2.5. Note 2: Reference measurement channel is Annex A.3.2 64QAM R=3/4variant with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. |