7.4A.1_H Maximum input level for CA (intra-band contiguous DL CA and UL CA) for 256QAM in DL

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

7.4A.1_H.1 Test purpose

Same test purpose as in clause 7.4A.1.

7.4A.1_H.2 Test applicability

This test applies to all types of E-UTRA UE release 12 and forward that support intra-band contiguous DL CA and UL CA and 256QAM in DL.

7.4A.1_H.3 Minimum conformance requirements

The minimum conformance requirements are defined in clause 7.4A.0 with the following exceptions:

– Instead of Table 7.4A.0-1, use Table 7.4A.1_H.3-1.

Table 7.4A.1_H.3-1: Maximum input level for intra-band contiguous CA

Rx Parameter

Units

CA Bandwidth Class

A

B

C

D

E

F

Power in largest Transmission Bandwidth Configuration CC

dBm

-282

-252

-252

-303

-273

-273

Power in each other CC

dBm

-28+ 10log(NRB,c /NRB,largest BW) 2

-25 + 10log(NRB,c /NRB,largest BW) 2

-25 + 10log(NRB,c /NRB,largest BW) 2

-30+ 10log(NRB,c /NRB,largest BW) 3

-27 + 10log(NRB,c /NRB,largest BW) 3

-27 + 10log(NRB,c /NRB,largest BW) 3

NOTE 1: The transmitter shall be set to 4dB below PCMAX_L,c or PCMAX_L as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is Annex A.3.2: 64QAM, R=3/4 variant with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1.

NOTE 3: Reference measurement channel is Annex A.3.2: 256QAM, R=4/5 variant with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1.

7.4A.1_H.4 Test description

7.4A.1_H.4.1 Initial conditions

Same initial conditions as in clause 7.4A.1.4.1 with the following exceptions:

– Instead of Table 7.4A.1.4.1-1, use Table 7.4A.1_H.4.1-1.

Table 7.4A.1_H.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in TS 36.508[7] clause 4.1

NC

Test Frequencies as specified in TS36.508 [7] clause 4.3.1 for different CA bandwidth classes, and PCC and SCCs are mapped onto physical frequencies according to Table 7.1-2

Mid range

Test CC Combination setting (NRB_agg) as specified in clause 5.4.2A.1 for the CA Configuration across bandwidth combination sets supported by the UE.

Lowest NRB_agg
Highest NRB_agg

Test Parameters for CA Configurations

use the content of Table 7.4A.1.4.1-1 replacing CC MOD of DL Allocation by 256QAM

7.4A.1_H.4.2 Test procedure

Same test procedure as in clause 7.4A.1.4.2 with the following exceptions:

– Instead of Table 7.4A.1.4.1-1, use Table 7.4A.1_H.4.1-1.

– Instead of Table 7.4A.1.5-1, use 7.4A.1_H.5-1.

– Instead of DCI format 1A use DCI format 1.

7.4A.1_H.4.3 Message contents

Same message contents as defined in clause 7.4A.1.4.3.

7.4A.1_H.5 Test requirement

The throughput measurement of each carrier derived in test procedure shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Table 7.4A.1_H.5-1.

Table 7.4A.1_H.5-1: Maximum input level for intra-band contiguous CA

Rx Parameter

Units

CA Bandwidth Class

A

B

C

D

E

F

Power in largest Transmission Bandwidth Configuration CC

dBm

For carrier frequency f ≤ 3.0GHz: -30.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -31.0

For carrier frequency f ≤ 3.0GHz: -27.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -28.0

Power in each other CC

dBm

For carrier frequency f ≤ 3.0GHz: -30.7 + 10log(NRB,c /NRB,largest BW)

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -31.0 + 10log(NRB,c /NRB,largest BW)

For carrier frequency f ≤ 3.0GHz: -27.7 + 10log(NRB,c /NRB,largest BW)

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -28.0 + 10log(NRB,c /NRB,largest BW)

Note 1: The transmitter shall be set to 4dB below PCMAX_L or PCMAX_L_CA as defined in subclause 6.2.5 for one uplink carrier and in subclause 6.2.5A for two uplink carriers.

Note 2: Reference measurement channel is Annex A.3.2: 256QAM, R=4/5 variant with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1.