7.3B Reference sensitivity level for UL-MIMO
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
7.3B.1 Test purpose
To verify the ability of UE that support UL-MIMO to receive data with a given average throughput for a specified reference measurement channel, under conditions of low signal level, ideal propagation and no added noise.
A UE unable to meet the throughput requirement under these conditions will decrease the effective coverage area of an e-NodeB.
7.3B.2 Test applicability
This test applies to all types of E-UTRA UE release 10 and forward that support UL-MIMO.
7.3B.3 Minimum conformance requirements
For UE with two transmitter antenna connectors in closed-loop spatial multiplexing scheme, the minimum requirements in Clause 7.3.3 shall be met with the UL-MIMO configurations specified in Table 6.2.2B.3-2. For UL-MIMO, the parameter PUMAX is the total transmitter power over the two transmit antenna connectors.
The normative reference for this requirement is TS 36.101 [2] clause 7.3.1B.
7.3B.4 Test description
7.3B.4.1 Initial conditions
Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.
The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in table 5.4.2.1-1. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 7.3B.4.1-1. The details of the downlink and uplink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3. The details of the OCNG patterns used are specified in Annex A.5. Configurations of PDSCH and PDCCH before measurement are specified in Annex C.2.
Table 7.3B.4.1-1: Test Configuration Table
Initial Conditions |
||||||
Test Environment as specified in TS 36.508[7] subclause 4.1 |
NC, TL/VL, TL/VH, TH/VL, TH/VH |
|||||
Test Frequencies as specified in TS36.508 [7] subclause 4.3.1 |
Low range, Mid range, High range |
|||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
Lowest, 5MHz, Highest |
|||||
Test Parameters for Channel Bandwidths |
||||||
Downlink Configuration |
Uplink Configuration |
|||||
Ch BW |
Mod’n |
RB allocation |
Mod’n |
RB allocation |
||
FDD |
TDD |
FDD |
TDD |
|||
1.4MHz |
QPSK |
6 |
6 |
QPSK |
6 |
6 |
3MHz |
QPSK |
15 |
15 |
QPSK |
15 |
15 |
5MHz |
QPSK |
25 |
25 |
QPSK |
25 |
25 |
5MHz |
QPSK |
25 |
N/A |
QPSK |
20 |
N/A |
5MHz |
QPSK |
25 |
N/A |
QPSK |
15 |
N/A |
5MHz |
QPSK |
25 |
N/A |
QPSK |
54 |
N/A |
10MHz |
QPSK |
50 |
50 |
QPSK |
50 |
50 |
10MHz |
QPSK |
50 |
N/A |
QPSK |
25 |
N/A |
10MHz |
QPSK |
50 |
N/A |
QPSK |
20 |
N/A |
10MHz |
QPSK |
50 |
N/A |
QPSK |
15 |
N/A |
15MHz |
QPSK |
75 |
75 |
QPSK |
75 |
75 |
15MHz |
QPSK |
75 |
N/A |
QPSK |
50 |
N/A |
15MHz |
QPSK |
75 |
N/A |
QPSK |
25 |
N/A |
15MHz |
QPSK |
75 |
N/A |
QPSK |
20 |
N/A |
20MHz |
QPSK |
100 |
100 |
QPSK |
100 |
100 |
20MHz |
QPSK |
100 |
N/A |
QPSK |
75 |
N/A |
20MHz |
QPSK |
100 |
N/A |
QPSK |
50 |
N/A |
20MHz |
QPSK |
100 |
N/A |
QPSK |
25 |
N/A |
20MHz |
QPSK |
100 |
N/A |
QPSK |
20 |
N/A |
Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, which applicable channel bandwidths are specified in Table 5.4.2.1-1. Note 2: Depending on E-UTRA band, only the appropriate Uplink RB allocation value according to table 7.3.3-2 is tested per Test Channel Bandwidth. Note 3: For the DL signal one sided dynamic OCNG Pattern OP.1 FDD/TDD is used. Note 4: Applicable only to E-UTRA FDD Bands 31 and 72. The UL resource blocks shall be located at RBstart 10 (according to Table 7.3.3-2). |
1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A, Figure A.28.
2. The parameter settings for the cell are set up according to TS 36.508 [7] subclause 4.4.3.
3. Downlink signals are initially set up according to Annex C0, C.1 and C.3.1, and uplink signals according to Annex H.1 and H.3.1.
4. The UL and DL Reference Measurement channels are set according to Table 7.3B.4.1-1.
5. Propagation conditions are set according to Annex B.0.
6. Ensure the UE is in State 3A-RF according to TS 36.508 [7] clause 5.2A.2. Message contents are defined in clause 7.3B.4.3.
7.3B.4.2 Test procedure
1. SS transmits PDSCH via PDCCH DCI format 1A for C_RNTI to transmit the DL RMC according to Table 7.3B.4.1-1. The SS sends downlink MAC padding bits on the DL RMC.
2. SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 4 for C_RNTI to schedule the UL RMC according to Table 7.3B.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.
3. Set the Downlink signal level to the appropriate REFSENS value defined in Table 7.3B.5-1. Send continuously uplink power control "up" commands in the uplink scheduling information to the UE to ensure the UE transmits PUMAX level for at least the duration of the throughput measurement.
4. Measure the average throughput for duration sufficient to achieve statistical significance according to Annex G.2.
7.3B.4.3 Message contents
Message contents are according to TS 36.508 [7] clause 4.6 with the following exceptions.
7.3B.4.3.1 Message contents exceptions (network signalled value "NS_01")
Message contents according to TS 36.508 [7] clause 4.6 can be used without exceptions.
7.3B.4.3.2 Message contents exceptions (network signalled value "NS_03")
1. Information element additionalSpectrumEmission is set to NS_03. This can be set in the SystemInformationblockType2 as part of the cell broadcast message. This exception indicates that the UE shall meet the additional spurious emission requirement for a specific deployment scenario.
Table 7.3B.4.3.2-1: SystemInformationBlockType2: Additional spurious emissions test requirement for "NS_03"
Derivation Path: TS 36.508 [7] clause 4.4.3.3, Table 4.4.3.3-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
additionalSpectrumEmission |
3 (NS_03) |
7.3B.4.3.3 Message contents exceptions (network signalled value "NS_06")
1. Information element additionalSpectrumEmission is set to NS_06. This can be set in the SystemInformationblockType2 as part of the cell broadcast message. This exception indicates that the UE shall meet the additional spurious emission requirement for a specific deployment scenario.
Table 7.3B.4.3.3-1: SystemInformationBlockType2: Additional spurious emissions test requirement for "NS_06"
Derivation Path: TS 36.508 [7] clause 4.4.3.3, Table 4.4.3.3-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
additionalSpectrumEmission |
6 (NS_06) |
7.3B.4.3.4 Message contents exceptions (network signalled value "NS_[09]")
1. Information element additionalSpectrumEmission is set to NS_[09]. This can be set in the SystemInformationblockType2 as part of the cell broadcast message. This exception indicates that the UE shall meet the additional spurious emission requirement for a specific deployment scenario.
Table 7.3B.4.3.4-1: SystemInformationBlockType2: Additional spurious emissions test requirement for "NS_[09]"
Derivation Path: TS 36.508 [7] clause 4.4.3.3, Table 4.4.3.3-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
additionalSpectrumEmission |
TBD |
7.3B.5 Test requirement
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.3.2 with parameters specified in Tables 7.3B.5-1 and Table 7.3B.5-2.
Table 7.3B.5-1: Reference sensitivity QPSK PREFSENS
Channel bandwidth |
|||||||
E-UTRA Band |
1.4 MHz (dBm) |
3 MHz (dBm) |
5 MHz (dBm) |
10 MHz (dBm) |
15 MHz (dBm) |
20 MHz (dBm) |
Duplex Mode |
1 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
FDD |
2 |
-102.0 |
-99.0 |
-97.3 |
-94.3 |
-92.5 |
-91.3 |
FDD |
3 |
-101.0 |
-98.0 |
-96.3 |
-93.3 |
-91.5 |
-90.3 |
FDD |
4 |
-104.0 |
-101.0 |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
FDD |
5 |
-102.5 |
-99.5 |
-97.3 |
-94.3 |
FDD |
||
6 |
– |
– |
-99.3 |
-96.3 |
FDD |
||
7 |
– |
– |
-97.3 |
-94.3 |
-92.5 |
-91.3 |
FDD |
8 |
-101.5 |
-98.5 |
-96.3 |
-93.3 |
FDD |
||
9 |
– |
– |
-98.3 |
-95.3 |
-93.5 |
-92.3 |
FDD |
10 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
FDD |
11 |
– |
– |
-99.3 |
-96.3 |
FDD |
||
12 |
-101.0 |
-98.0 |
-96.3 |
-93.3 |
FDD |
||
13 |
-96.3 |
-93.3 |
FDD |
||||
14 |
– |
-96.3 |
-93.3 |
FDD |
|||
… |
|||||||
17 |
– |
– |
-96.3 |
-93.3 |
FDD |
||
18 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
– |
FDD |
19 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
– |
FDD |
20 |
-96.3 |
-93.3 |
-90.5 |
-89.3 |
FDD |
||
21 |
-99.3 |
-96.3 |
-94.5 |
FDD |
|||
22 |
-96.0 |
-93.0 |
-91.2 |
-90.0 |
FDD |
||
23 |
-104.0 |
-101.0 |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
FDD |
24 |
-99.3 |
-96.3 |
FDD |
||||
25 |
-100.5 |
-97.5 |
-95.8 |
-92.8 |
-91.0 |
-89.8 |
FDD |
26 |
-102 |
-99 |
-96.86 |
-93.86 |
-926 |
FDD |
|
27 |
-102.5 |
-99.5 |
-97.3 |
-94.3 |
FDD |
||
28 |
-99.5 |
-97.8 |
-94.8 |
-93.0 |
-90.3 |
FDD |
|
30 |
– |
– |
-98.3 |
-95.3 |
– |
– |
FDD |
31 |
-98.3 |
-95.0 |
-92.8 |
FDD |
|||
… |
|||||||
33 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
34 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
– |
TDD |
35 |
-105.5 |
-101.5 |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
36 |
-105.5 |
-101.5 |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
37 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
38 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
39 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
40 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
41 |
– |
– |
-97.3 |
-94.3 |
-92.5 |
-91.3 |
TDD |
42 |
– |
– |
-98.0 |
-95.0 |
-93.2 |
-92.0 |
TDD |
43 |
– |
– |
-98.0 |
-95.0 |
-93.2 |
-92.0 |
TDD |
45 |
– |
– |
-99.3 |
-96.3 |
-94.5 |
-93.3 |
TDD |
… |
|||||||
48 |
-98.0 |
-95.0 |
-93.2 |
-92.0 |
TDD |
||
… |
|||||||
65 |
-103.5 |
-100.5 |
-99.5 |
-96.5 |
-94 |
-92.8 |
FDD |
66 |
-103.5 |
-100.5 |
-98.8 |
-95.8 |
-94 |
-92.8 |
FDD |
… |
|||||||
68 |
-97.8 |
-94.8 |
-93.0 |
FDD |
|||
… |
|||||||
72 |
-98.3 |
-95.0 |
-92.8 |
FDD |
|||
Note 1: The transmitter shall be set to PUMAX as defined in clause 6.2.5 Note 2: The reference measurement channel is specified in A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1 Note 3: The signal power is specified per port Note 4: For the UE which supports both Band 3 and Band 9 the reference sensitivity level is FFS. Note 5: For the UE which supports both Band 11 and Band 21 the reference sensitivity level is FFS. Note 6: 6 indicates that the requirement is modified by -0.5 dB when the carrier frequency of the assigned E-UTRA channel bandwidth is within 865-894 MHz. |
For the UE which supports inter-band carrier aggregation configurations the ΔRIB,c in Tables 7.3.3-1A, 7.3.3-1B and 7.3.3-1C shall be applied for applicable bands.
In case the UE supports more than one of the inter-band carrier aggregation configurations and an E-UTRA operating band belongs to more than one inter-band carrier aggregation configurations then:
– When the E-UTRA operating band frequency range is ≤ 1GHz, the applicable additional tolerance shall be the average of the tolerances in Table 7.3.3-1A, truncated to one decimal place that would apply for that operating band among the supported CA configurations. In case there is a harmonic relation between low band UL and high band DL (i.e. bands listed in Table 7.3A.0-0a), then the maximum tolerance among the different supported carrier aggregation configurations involving such band shall be applied
– When the E-UTRA operating band frequency range is >1GHz, the applicable additional tolerance shall be the maximum tolerance in Table 7.3.3-1A that would apply for that operating band among the supported CA configurations
NOTE 1: The relation to the received PSD is with NRB is the transmission bandwidth configuration according to Table 5.4.2-1.
The reference receive sensitivity (REFSENS) requirement specified in Table 7.3B.5-1 shall be met for an uplink transmission bandwidth less than or equal to that specified in Table 7.3B.5-2.
NOTE 2: Table 7.3B.5-2 does not necessarily reflect the operational conditions of the network, where the number of uplink and downlink allocated resource blocks will be practically constrained by other factors.
Table 7.3B.5-2: Uplink configuration for reference sensitivity
E-UTRA Band / Channel bandwidth / NRB / Duplex mode |
|||||||
E-UTRA Band |
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
Duplex Mode |
1 |
– |
– |
25 |
50 |
75 |
100 |
FDD |
2 |
6 |
15 |
25 |
50 |
501 |
501 |
FDD |
3 |
6 |
15 |
25 |
50 |
501 |
501 |
FDD |
4 |
6 |
15 |
25 |
50 |
75 |
100 |
FDD |
5 |
6 |
15 |
25 |
251 |
– |
– |
FDD |
6 |
– |
– |
25 |
251 |
– |
– |
FDD |
7 |
– |
– |
25 |
50 |
751 |
751 |
FDD |
8 |
6 |
15 |
25 |
251 |
– |
– |
FDD |
9 |
– |
– |
25 |
50 |
501 |
501 |
FDD |
10 |
– |
– |
25 |
50 |
75 |
100 |
FDD |
11 |
– |
– |
25 |
251 |
FDD |
||
12 |
6 |
15 |
201 |
201 |
FDD |
||
13 |
201 |
201 |
FDD |
||||
14 |
– |
151 |
151 |
FDD |
|||
… |
|||||||
17 |
– |
– |
201 |
201 |
FDD |
||
18 |
– |
– |
25 |
251 |
251 |
– |
FDD |
19 |
– |
– |
25 |
251 |
251 |
– |
FDD |
20 |
25 |
201 |
203 |
203 |
FDD |
||
21 |
25 |
251 |
251 |
FDD |
|||
22 |
25 |
50 |
501 |
501 |
FDD |
||
23 |
6 |
15 |
25 |
50 |
751 |
1001 |
FDD |
24 |
25 |
50 |
FDD |
||||
25 |
6 |
15 |
25 |
50 |
501 |
501 |
FDD |
26 |
6 |
15 |
25 |
251 |
251 |
FDD |
|
27 |
6 |
15 |
25 |
251 |
– |
– |
FDD |
28 |
15 |
25 |
251 |
251 |
251 |
FDD |
|
30 |
– |
– |
25 |
251 |
– |
– |
FDD |
31 |
6 |
54 |
54 |
FDD |
|||
… |
|||||||
33 |
– |
– |
25 |
50 |
75 |
100 |
TDD |
34 |
– |
– |
25 |
50 |
75 |
– |
TDD |
35 |
6 |
15 |
25 |
50 |
75 |
100 |
TDD |
36 |
6 |
15 |
25 |
50 |
75 |
100 |
TDD |
37 |
– |
– |
25 |
50 |
75 |
100 |
TDD |
38 |
– |
– |
25 |
50 |
75 |
100 |
TDD |
39 |
25 |
50 |
75 |
100 |
TDD |
||
40 |
25 |
50 |
75 |
100 |
TDD |
||
41 |
25 |
50 |
75 |
100 |
TDD |
||
42 |
25 |
50 |
75 |
100 |
TDD |
||
43 |
25 |
50 |
75 |
100 |
TDD |
||
45 |
25 |
50 |
75 |
100 |
TDD |
||
… |
|||||||
48 |
25 |
50 |
75 |
100 |
TDD |
||
… |
|||||||
65 |
6 |
15 |
25 |
50 |
75 |
100 |
FDD |
66 |
– |
– |
25 |
50 |
75 |
100 |
FDD |
… |
|||||||
68 |
25 |
251 |
251 |
||||
… |
|||||||
72 |
6 |
54 |
54 |
FDD |
|||
Note 1: The UL resource blocks shall be located as close as possible to the downlink operating band but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1). Note 2: For the UE which supports both Band 11 and Band 21 the uplink configuration for reference sensitivity is FFS. Note 3: For Band 20; in the case of 15MHz channel bandwidth, the UL resource blocks shall be located at RBstart=11 and in the case of 20MHz channel bandwidth, the UL resource blocks shall be located at RBstart=16. Note 4: 4 refers to Bands 31 and 72; in the case of 3 MHz channel bandwidth, the UL resource blocks shall be located at RBstart 9 and in the case of 5 MHz channel bandwidth, the UL resource blocks shall be located at RBstart 10. |