7.3A.0 Minimum conformance requirements

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

For inter-band carrier aggregation with one component carrier per operating band and the uplink assigned to one E-UTRA band the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.3.3-1, Table 7.3.3-1a and Table 7.3.3-2. The reference sensitivity is defined to be met with all downlink component carriers active and one of the uplink carriers active. The uplink resource blocks shall be located as close as possible to the primary downlink operating band but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1). The primary downlink operating band is the downlink band of the active uplink operating band. The UE shall meet the requirements specified in subclause 7.3.3 with the following exceptions.

For the bands supporting 4 antenna ports which are in Table 7.3.3-1a, the minimum requirements for reference sensitivity in the reference sensitivity exception tables shall be modified by the amount given in ΔRIB,4R in Table 7.3.3-1a for the applicable E-UTRA bands unless otherwise specified.

For the bands supporting 8 antenna ports which are in Table 7.3.3-1aa, the minimum requirements for reference sensitivity in the reference sensitivity exception tables shall be modified by the amount given in ΔRIB,8R in Table 7.3.3-1aa for the applicable E-UTRA bands unless otherwise specified.

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0a, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by harmonic interference from the uplink transmission in a lower-frequency band of the same CA configuration. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-0a and Table 7.3A.0-0b.

Table 7.3A.0-0a: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions due to harmonic issue)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A-5A-7A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-5A-28A 5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-5A-41A28

41

N/A

TDD

CA_1A-3A-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-7A-8A4,5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-3C-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3C-7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-3A-7A-8A-20A5,6

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-7A-8A-20A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-3A-7A-20A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-7A-20A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-7A-20A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-7A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-7A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-7A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-8A-11A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-8A-20A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-8A-11A-28A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-8A-28A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-8A-38A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-11A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-11A-28A9,10

11

-75.2

-75.2

FDD

CA_1A-3A-8A-40A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-18A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-18A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-19A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-19A-42A11

42

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-20A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-20A-32A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-20A-32A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-20A-32A-42A12,13

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_1A-3A-21A-28A4,21

21

N/A

N/A

N/A

FDD

CA_1A-3A-21A-42A22,23

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-21A-42A24

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-28A-40A15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_1A-3A-28A-42A22,23

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-28A-42A24

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-28A5,6

CA_1A-1A-3A-28A

CA_1A-1A-3C-28A

CA_1A-3A-3A-28A

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-32A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-32A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42A-43A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42A-43A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-32A-42A-43A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-32A-42A-43A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-41A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-41A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-3A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-3A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42A-42C9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42A-42C11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42C-42C9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42C-42C11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-5A-7A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-5A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-5A-41A8

41

N/A

TDD

CA_1A-7A-8A5,6,

CA_1A-7A-7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-7A-8A-20A

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-7A-8A-40A5,6

733

-87.1

-86.7

-86.4

FDD

CA_1A-7A-20A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-7A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-7A-28A-40A15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_1A-8A-20A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-11A-28A5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-11A-28A9,10

11

-75.2

-75.2

FDD

CA_1A-18A-28A14

1

N/A

N/A

N/A

N/A

FDD

CA_1A-19A-28A14

133

N/A

N/A

N/A

N/A

FDD

CA_1A-20A-28A

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-20A-32A-42A12,13

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_1A-21A-28A4,21

21

N/A

N/A

N/A

FDD

CA_1A-21A-28A-42A4,21

21

N/A

N/A

N/A

FDD

CA_1A-28A5,6,14

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-1A-28A5,6,14

1

-89.8

-89.4

-89

-88.7

FDD

CA_1A-28A-40A15,16

CA_1A-28A-40C15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_1A-28A-40A5,6

CA_1A-28A-40C5,6

133

-89.8

-89.4

-89

-88.7

FDD

CA_1A-28A-42A5,6,17,18

133

-89.8

-89.4

-89

-88.7

FDD

4233

-85.7

-85.4

-85.1

-84.9

TDD

CA_2A-46A15,16

2

-70

-67

-65.2

-64

FDD

CA_2A-2A-46A15,16

2

-70

-67

-65.2

-64

FDD

CA_2A-48A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-71A36

2

-93.4

-94

-92.5

-91.4

FDD

CA_2A-71A37

2

-96.8

-94

-92.5

-91.4

FDD

CA_2A-71A15,16

71

-70.4

-70.4

-70.4

-70.4

FDD

CA_2A-2A-71A36

2

-93.4

-94

-92.5

-91.4

FDD

CA_2A-2A-71A37

2

-96.8

-94

-92.5

-91.4

FDD

CA_2A-2A-71A15,16

71

-70.4

-70.4

-70.4

-70.4

FDD

CA_2A-4A-12A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-28A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-71A36, CA_2A-2A-4A-71A36

2

-93.1

-93.7

-92.2

-91.1

FDD

CA_2A-4A-71A37, CA_2A-2A-4A-71A37

2

-96.5

-93.7

-92.2

-91.1

FDD

CA_2A-4A-71A15,16, CA_2A-2A-4A-71A15,16

71

-70.4

-70.4

-70.4

-70.4

FDD

CA_2A-4A-5A-12A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-7A-12A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-12A-30A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_2A-5A-12A-66A 5,6

66

-89.5

-89

-88.5

-88

FDD

CA_2A-7A-12A-66A5,6

6633

-89.5

-89

-88.5

-88

FDD

CA_2A-12A-66A5,6

6633

-89.5

-89

-88.5

-88

FDD

CA_2A-13A-48A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-13A-48A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-28A-66A5,6

66

-89,5

-88,9

-88,5

-88,2

FDD

CA_2A-48A-48A10,31

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48A-48C10,31

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48C11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48C9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48C11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48D9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48D11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48A-66A10,32, CA_2A-48C-66A10,32

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-66A11, CA_2A-48C-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-66A-71A36

CA_2A-2A-66A-71A36

CA_2A-66A-66A-71A36

CA_2A-66C-71A36

2

-93.1

-93.7

-92.2

-91.1

FDD

CA_2A-66A-71A37

CA_2A-2A-66A-71A37

CA_2A-66A-66A-71A37

CA_2A-66C-71A37

2

-96.5

-93.7

-92.2

-91.1

FDD

CA_2A-66A-71A15,16

CA_2A-2A-66A-71A15,16

CA_2A-66A-66A-71A15,16

CA_2A-66C-71A15,16

71

-70.4

-70.4

-70.4

-70.4

FDD

CA_3A-5A-41A28

41

N/A

TDD

CA_3A-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_3C-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_3C-7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_3A-7A-8A-20A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-8A-20A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-3A-8A-20A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-8A-38A 4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-8A-40A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-8A-40A5,6

733

-87.1

-86.7

-86.4

FDD

CA_3A-7A-20A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-7A-20A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-7A-28A-40A15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_3A-7A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-7A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-11A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-11A-28A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-32A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-38A4

3

N/A

N/A

N/A

N/A

FDD

CA_3C-8A-38A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-40A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-8A-40C4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-11A-28A9,10

11

-75.2

-75.2

FDD

CA_3A-18A-42A9,10

CA_3A-18A-42C9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-18A-42A11

CA_3A-18A-42C11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-19A-21A-42A25,26

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-19A-21A-42A27

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-19A-21A-42C25,26

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-19A-21A-42C27

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-19A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-19A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-20A-32A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-20A-32A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-20A-32A-42A12,13

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_3A-20A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-20A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-21A-28A4,21

21

N/A

N/A

N/A

FDD

CA_3A-21A-28A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-21A-28A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-21A-28A-42C9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-21A-28A-42C11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-21A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-21A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-40A15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_3A-28A-41A-42A9,10,29

41

-94.5

-92.7

-91.5

TDD

4233

-71.7

-71.7

-71.7

CA_3A-28A-41A-42A11,29

41

-94.5

-92.7

-91.5

TDD

4233

-94.7

-93.2

-92.5

CA_3A-28A-41A-42A17,18, 29

41

-94.5

-92.7

-91.5

TDD

4233

-85.4

-85.1

-84.9

CA_3A-28A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42A17,18

4233

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-31A12,13

333

-86.9

-86.4

-86

-85.6

FDD

CA_3A-32A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-32A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42A-42A9,10

4233

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-3A-42A11

4233

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42A-43A9. 10

42

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42A-43A11

42

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-32A-42A-43A9. 10

42

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-32A-42A-43A11

42

-97.1

-94.7

-93.2

-92.5

TDD

CA_4A-5A-12A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_4A-7A-12A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_4A-7A -28A5,6

433

-89.8

-89.4

-89

-88.7

FDD

CA_4A-12A5,6

433

-89.2

-89.2

-90

-89.5

-89

-88.5

FDD

CA_4A-12A-30A5,6

433

-90

-89.5

-89

-88.5

FDD

CA_4A-17A5,6

433

-90

-89.5

FDD

CA_4A-28A5,6

433

-89.8

-89.4

-89

-88.7

FDD

CA_5A-12A-66A5,6

6633

-90

-89.5

-89

-88.5

FDD

CA_5A-38A19

38

N/A

N/A

N/A

N/A

TDD

CA_5A-41A8,19

41

N/A

TDD

CA_5A-40A-41A8

41

N/A

TDD

CA_5A-48A-66A9,10

CA_5A-48A-66A-66A9,10

4833

-71.7

-71.7

-71.7

-71.7

TDD

CA_5A-48A-66A11

CA_5A-48A-66A-66A11

4833

-97.1

-94.7

-93.2

-92.5

TDD

CA_7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_7A-8A-20A5,6

733

-87.4

-87

-86.7

FDD

CA_7A-12A-66A5,6

6633

-89.5

-89

-88.5

-88

FDD

CA_7A-12B-66A5,6

6633

-89.5

-89

-88.5

-88

FDD

CA_7A-20A-38A19

38

N/A

N/A

N/A

N/A

TDD

CA_7A-28A-40A15,16

CA_7A-28A-40C15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_8A-28A-41A28

41

N/A

N/A

N/A

N/A

TDD

CA_8A-39A-41A4

41

N/A

TDD

CA_8A-41A8

41

N/A

N/A

N/A

N/A

TDD

CA_8A-42A12,13

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_11A-28A9,10

1133

-75.2

-75.2

FDD

CA_12A-30A-66A5,6

6633

-89.5

-89

-88.5

-88

FDD

CA_12A-66A5,6

6633

-88.7

-88.7

-89.5

-89

-88.5

-88

FDD

CA_13A-48A-66A9,10

CA_13A-48A-66A-66A9,10

CA_13A-48A-66B9,10

CA_13A-48A-66C9,10

CA_13A-48A-48A-66A9,10

CA_13A-48C-66A9,10

CA_13A-48D-66A9,10

CA_13A-48A-48C-66A9,10

4833

-71.7

-71.7

-71.7

-71.7

TDD

CA_13A-48A-66A11

CA_13A-48A-66A-66A11

CA_13A-48A-66B11

CA_13A-48A-66C11

CA_13A-48A-48A-66A11

CA_13A-48C-66A11

CA_13A-48D-66A11

CA_13A-48A-48C-66A11

CA_13A-48E-66A

4833

-97.1

-94.7

-93.2

-92.5

TDD

CA_20A-32A-42A12,13

20

-97

FDD

32

-100

-97

-95.2

-94

FDD

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_20A-38A19

20

N/A

N/A

N/A

N/A

FDD

CA_20A-38A-40D15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-38C19

38

N/A

N/A

N/A

N/A

TDD

CA_20A-40A15,16

2033

-60.7

-60.7

-60.7

-60.7

FDD

CA_20A-40A-40A15,16

2033

-60.7

-60.7

-60.7

FDD

CA_20A-38A-40A15,16

2033

-60.7

-60.7

-60.7

FDD

CA_20A-40C15,16

2033

-60.7

-60.7

-60.7

FDD

CA_20A-40D15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-38A-40A-40A15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-38A-40C15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-42A12,13, CA_20A-42A-42A12,13

4233

-84.8

-84.7

-84.6

-84.5

TDD

CA_21A-28A4,21

21

N/A

N/A

N/A

FDD

CA_21A-28A-42A4,21

21

N/A

N/A

N/A

N/A

FDD

CA_25A-26A-41A38

41

N/A

N/A

N/A

N/A

TDD

CA_25A-25A-26A-41A8

CA_25A-26A-41C8

41

N/A

N/A

N/A

N/A

TDD

CA_26A-41A8,19

41

N/A

N/A

N/A

N/A

TDD

CA_28A-32A9,10

32

-72.2

-72.2

-72.2

-72.2

FDD

CA_28A-32A11

32

-97.6

-95.2

-93.7

-93.0

FDD

CA_28A-40A15,16

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_28A-41A-42A17,18

4233

-85.4

-85.1

-84.9

TDD

CA_28A-42A17,18

4233

-85.7

-85.4

-85.1

-84.9

TDD

CA_28A-66A5,6

66

-89.5

-88.9

-88.5

-88.2

FDD

CA_48A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-66B9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-66B11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-66C9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-66C11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-66A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-66A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48A-66A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48A-66A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48A-66B9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48A-66B11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48A-66C9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48A-66C11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48C-66A-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

66

-99.3

-96.3

-94.5

-93.2

FDD

CA_48C-66A-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

66

-99.3

-96.3

-94.5

-93.2

FDD

CA_48C-66B9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48C-66B11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48C-66C9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48C-66C11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48C-66A9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48C-66A11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48E-66A 9,10

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48E-66A 11

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_66A-70A-71A5,6

70

-90

-89.5

-89.2

FDD

CA_66A-66A-70A-71A5,6

70

-90

-89.5

-89.2

FDD

CA_66A-70C-71A5,6, 35

70

-90

-89.5

-89.2

-89

FDD

CA_66A-66A-70C-71A5,6,35

70

-90

-89.5

-89.2

-89

FDD

CA_66C-70A-71A5,6

70

-90

-89.5

-89.2

FDD

CA_66C-70C-71A5,6,35

70

-90

-89.5

-89.2

-89

FDD

CA_70A-71A5,6

70

-90

-89.5

-89.2

FDD

CA_70C-71A5,6,35

70

-90

-89.5

-89.2

-89

FDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD/FS3 as described in Annex A.5.1.1/A.5.2.1/A.5.4.1.

NOTE 3: The signal power is specified per port

NOTE 4: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity for all active downlink component carriers is only verified when this is not the case (the requirements specified in clause 7.3.3 apply unless otherwise specified).

NOTE 5: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 6: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 7: Void.

NOTE 8: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity is only verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 9: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_3A-42A, CA_3A-3A-42A, CA_3A-42A-42A, CA_1A-3A-20A-32A-42A, CA_3A-42A-43A, CA_3A-32A-42A-43A, CA_1A-3A-42A, CA_2A-13A-48A-66A, CA_2A-48A, CA_2A-48C, CA_2A-48D, CA_48A-66A, CA_3A-7A-42A, CA_3A-19A-42A, CA_3A-20A-42A, CA_3A-28A-42A, CA_1A-3A-7A-42A, CA_5A-48A-66A, CA_5A-48A-66A-66A, CA_13A-48A-66A, CA_13A-48A-66A-66A, CA_13A-48A-66B, CA_13A-48A-66C, CA_13A-48A-48A-66A, CA_13A-48C-66A, CA_13A-48D-66A, CA_13A-48A-48C-66A, CA_28A-32A, CA_48A-66A-66A, CA_48A-66B , CA_48A-66C, CA_48A-48A-66A, CA_48C-66A, CA_48A-48A-66A-66A, CA_48A-48A-66B, CA_48A-48A-66C, CA_48C-66B, CA_48C-66C, CA_48E-66A, CA_1A-3A-18A-42A, CA_1A-3A-19A-42A, CA_1A-3A-32A-42A, CA_1A-3A-41A-42A, CA_3A-7A-20A-42A, CA_3A-20A-32A-42A, CA_3A-28A-41A-42A, CA_3A-18A-42A and CA_3A-18A-42C. FHD = 0MHz for CA_11A-28A, CA_1A-11A-28A and CA_3A-11A-28A.

NOTE 10: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 11: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

NOTE 12: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 4th transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 13: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 14: For the UE that supports CA_1A-18A-28A or CA_1A-19A-28A, no requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity should only be verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 15: These requirements apply when there is at least one individual RE within the downlink transmission bandwidth of the victim (lower) band for which the 3rd harmonic is within the uplink transmission bandwidth or the uplink adjacent channel’s transmission bandwidth of an aggressor (higher) band.

NOTE 16: The requirements should be verified for UL EARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with  the carrier frequency in the victim (lower) band and  the channel bandwidth configured in the higher band.

NOTE 17: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 5th transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 18: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 19: No requirements apply for the case that there is at least one individual RE within the uplink transmission bandwidth of the relative higher band and when the frequency range of relative higher band’s uplink channel bandwidth or uplink 1st adjacent channel bandwidth is fully or partially overlapped with the 3 times of the frequency range of the relative lower band’s downlink channel bandwidth. The reference sensitivity is only verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 20: Void

NOTE 21: No requirements apply when there is at least one individual RE on band 28 uplink outside frequencies 728 – 738 MHz. The reference sensitivity is only verified when all configured RE’s are confined within frequencies 728 – 738 MHz (the requirements specified in clause 7.3.3 apply).

NOTE 22: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_1A-3A-21A-42A.

NOTE 23: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 24: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

NOTE 25: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_3A-19A-21A-42A.

NOTE 26: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 27: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

NOTE 28: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of either Band 5 or Band 8 for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of Band 41. The reference sensitivity for all active downlink component carriers is only verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 29: The B41 requirements are modified by -0.1dB when carrier frequency of the assigned E-UTRA channel bandwidth is within 2545-2690 MHz.

NOTE 30: Void

NOTE 31: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_2A-48A-48A and CA_2A-48A-48C

NOTE 32: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_2A-48A-66A, CA_2A-48A-66A-66A and CA_2A-48C-66A

NOTE 33: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

NOTE 34: Void

NOTE 35: These exceptions for the intra-band class C carriers should be verified one carrier at a time, according to note 6 frequency arrangements. No exceptions apply for the carrier which is not under REFSENS exception test.

NOTE 36: These requirements apply when the lower edge frequency of the 5 MHz uplink channel in Band 71 is located at or below 668 MHz and the downlink channel in Band 2 is located with its upper edge at 1990 MHz.

NOTE 37: These requirements apply when the lower edge frequency of the 10 MHz, 15 MHz, or 20 MHz uplink channel in Band 71 is located at or below 668 MHz and the downlink channel in Band 2 is located with its upper edge at 1990 MHz.

NOTE 38: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 3nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 15 MHz for CA_26A-41A, CA_25A-26A-41A.

Table 7.3A.0-0b: Uplink configuration for the low band (exceptions due to harmonic issue)

E-UTRA Band / Channel bandwidth of the high band / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A-5A-7A-28A

28

8

16

25

25

FDD

CA_1A-3A-5A-28A

28

8

16

25

25

FDD

CA_1A-3A-7A-8A

8

8

16

25

25

FDD

CA_1A-3C-7A-8A

8

8

16

25

25

FDD

CA_1A-3A-7A-8A-20A

8

8

16

25

25

FDD

CA_1A-3A-7A-20A-28A

28

8

16

25

25

FDD

CA_1A-3A-7A-20A-42A

3

12

25

36

50

FDD

CA_1A-3A-7A-28A

28

16

25

25

FDD

CA_1A-3A-7A-42A

3

12

25

36

50

FDD

CA_1A-3A-11A-28A4

28

8

16

25

25

FDD

CA_1A-3A-11A-28A5

28

12

25

FDD

CA_1A-3A-18A-42A

3

12

25

36

50

FDD

CA_1A-3A-19A-42A

3

12

25

36

50

FDD

CA_1A-3A-28A

CA_1A-1A-3A-28A

CA_1A-3A-3A-28A

28

8

16

25

25

FDD

CA_1A-3A-42A

3

12

25

36

50

FDD

CA_1A-3A-3A-42A

3

12

25

36

50

FDD

CA_1A-3A-42A-42A

3

12

25

36

50

FDD

CA_1A-3A-42A-42C

3

12

25

36

50

FDD

CA_1A-3A-42C-42C

3

12

25

36

50

FDD

CA_1A-3A-20A-28A

28

8

16

25

25

FDD

CA_1A-3A-21A-42A

3

12

25

36

50

FDD

CA_1A-3A-28A-40A

40

25

50

75

100

TDD

CA_1A-3A-28A-42A

3

12

25

36

50

FDD

CA_1A-3A-41A-42A

3

12

25

36

50

FDD

CA_1A-5A-7A-28A

28

8

16

25

25

FDD

CA_1A-7A-8A

8

8

16

25

25

FDD

CA_1A-3A-32A-42A

3

12

25

36

50

FDD

CA_1A-3A-42A-43A

3

12

25

36

50

FDD

CA_1A-7A-8A-20A

CA_1A-7A-7A-8A

8

8

16

FDD

CA_1A-7A-8A-40A

8

8

16

25

25

FDD

CA_1A-7A-20A-28A

28

8

16

25

25

FDD

CA_1A-7A-28A

28

8

16

25

25

FDD

CA_1A-7A-28A-40A

40

25

50

75

100

TDD

CA_1A-8A-20A-28A

28

8

16

25

25

FDD

CA_1A-11A-28A4

28

8

16

25

25

FDD

CA_1A-11A-28A5

28

12

25

FDD

CA_1A-20A-28A

28

8

16

25

25

FDD

CA_1A-20A-32A-42A

20

8

16

25

25

FDD

CA_1A-3A-20A-32A-42A

3

12

25

36

50

FDD

20

8

16

25

25

FDD

CA_1A-3A-32A-42A-43A

3

12

25

36

50

FDD

CA_1A-28A

28

8

16

25

25

FDD

CA_1A-1A-28A

28

8

16

25

25

FDD

CA_1A-28A-40A

40

25

50

75

100

TDD

CA_1A-28A-42A

28

8

16

25

25

FDD

CA_2A-46A

46

100

TDD

CA_2A-2A-46A

46

100

TDD

CA_2A-71A

71

25

251

201

201

FDD

CA_2A-71A

2

25

50

50

50

FDD

CA_2A-2A-71A

71

25

50

50

50

FDD

CA_2A-4A-12A

12

8

16

20

20

FDD

CA_2A-4A-28A

28

8

16

25

FDD

CA_2A-4A-71A

CA_2A-2A-4A-71A

71

25

50

50

50

FDD

CA_2A-4A-5A-12A

12

8

16

FDD

CA_2A-4A-7A-12A

12

8

16

FDD

CA_2A-4A-12A-30A

12

8

16

FDD

CA_2A-5A-12A-66A

12

8

16

20

20

FDD

CA_2A-7A-12A-66A

12

8

16

FDD

CA_2A-12A-66A

12

8

16

FDD

CA_2A-13A-48A

2

25

50

501

501

FDD

CA_2A-13A-48A-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-48A

CA_2A-48A-48A

CA_2A-48A-48C

CA_2A-48D

2

25

50

501

501

FDD

CA_2A-48A-66A

CA_2A-48C-66A

CA_2A-48A-66A-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-66A-71A

CA_2A-2A-66A-71A

CA_2A-66A-66A-71A

CA_2A-66C-71A

71

25

50

50

50

FDD

CA_3A-7A-8A

8

8

16

25

25

FDD

CA_3C-7A-8A

8

8

16

25

25

FDD

CA_3A-7A-20A-42A

3

12

25

36

50

FDD

CA_3A-7A-8A-40A

8

8

16

25

25

FDD

CA_3A-7A-28A-40A

40

25

50

75

100

TDD

CA_3A-7A-42A

3

12

25

36

50

FDD

CA_3A-8A-32A

8

8

16

25

25

FDD

CA_3A-11A-28A

28

12

25

FDD

CA_3A-18A-42A

CA_3A-18A-42C

3

12

25

36

50

FDD

CA_3A-19A-42A

3

12

25

36

50

FDD

CA_3A-19A-21A-42A

3

12

25

36

50

FDD

CA_3A-20A-32A-42A

3

12

25

36

50

FDD

20

8

16

25

25

FDD

CA_3A-19A-21A-42C

3

12

25

36

50

FDD

CA_3A-20A-42A

3

12

25

36

50

FDD

CA_3A-21A-28A-42A

3

12

25

36

50

FDD

CA_3A-21A-28A-42C

3

12

25

36

50

FDD

CA_3A-21A-42A

3

12

25

36

50

FDD

CA_3A-28A-40A

40

25

50

75

100

TDD

CA_3A-28A-41A-42A

3

25

36

50

FDD

CA_3A-28A-41A-42A

28

10

15

20

FDD

CA_3A-31A

31

5

5

5

5

FDD

CA_3A-32A-42A

3

12

25

36

50

FDD

CA_3A-32A-42A-43A

3

12

25

36

50

FDD

CA_3A-42A

3

12

25

36

50

FDD

CA_3A-3A-42A

3

12

25

36

50

FDD

CA_3A-42A-42A

3

12

25

36

50

FDD

CA_3A-42A-43A

3

12

25

36

50

FDD

CA_4A-5A-12A

12

8

16

20

20

FDD

CA_4A-7A-12A

12

8

16

20

20

FDD

CA_4A-7A-28A

28

[8]

[16]

[25]

[25]

FDD

CA_4A-12A

12

2

5

8

16

20

20

FDD

CA_4A-12A-30A

12

8

16

FDD

CA_4A-17A

17

8

16

FDD

CA_4A-28A

28

[8]

[16]

[25]

[25]

FDD

CA_5A-12A-66A

12

8

16

20

20

FDD

CA_5A-48A-66A

CA_5A-48A-66A-66A

66

121

251

361

501

FDD

CA_7A-8A

8

8

16

25

25

FDD

CA_7A-8A-20A

8

16

25

25

FDD

CA_7A-12A-66A

12

8

16

FDD

CA_7A-12B-66A

12

8

16

FDD

CA_7A-28A-40A

40

25

50

75

100

TDD

CA_8A-42A

8

8

16

25

25

FDD

CA_11A-28A

28

12

25

FDD

CA_12A-30A-66A

12

8

16

FDD

CA_12A-66A

12

2

5

8

16

20

20

FDD

CA_13A-48A-66A

CA_13A-48A-66A-66A

CA_13A-48A-66B

CA_13A-48A-66C

CA_13A-48A-48A-66A

CA_13A-48C-66A

CA_13A-48D-66A

CA_13A-48A-48C-66A

CA_13A-48E-66A

66

121

251

361

501

FDD

CA_20A-32A-42A

20

8

16

25

25

FDD

CA_20A-40A3

CA_20A-40D3

CA_20A-38A-40A-40A3

CA_20A-38A-40C3

40

25

50

75

100

TDD

CA_20A-40C3

40

25

50

75

TDD

CA_20A-40A-40A3

40

25

50

75

TDD

CA_20A-38A-40A3

40

25

50

75

TDD

CA_20A-38A-40D3

40

25

50

75

TDD

CA_20A-42A,

CA_20A-42A-42A

20

8

16

25

25

FDD

CA_28A-32A

28

12

25

36

50

FDD

CA_28A-40A

40

25

50

75

100

TDD

CA_28A-41A-42A

28

10

15

20

FDD

CA_28A-42A

28

5

10

15

20

FDD

CA_28A-66A

28

8

16

25

25

FDD

CA_48A-66A

66

12

25

36

50

FDD

CA_48A-48A-66A

66

12

25

36

50

FDD

CA_48A-48A-66A-66A

66

12

25

36

50

FDD

CA_48A-48A-66B

66

12

25

36

50

FDD

CA_48A-48A-66C

66

12

25

36

50

FDD

CA_48C-66A-66A

66

12

25

36

50

FDD

CA_48C-66B

66

12

25

36

50

FDD

CA_48C-66C

66

12

25

36

50

FDD

CA_48A-66A-66A

66

121

251

361

501

FDD

CA_48A-66B

66

121

251

361

501

FDD

CA_48A-66C

66

121

251

361

501

FDD

CA_48C-66A

66

12

25

36

50

FDD

CA_48E-66A

66

12

25

36

50

FDD

CA_66A-70A-71A

71

8

16

20

FDD

CA_66A-66A-70A-71A

71

8

16

20

FDD

CA_66A-70C-71A

71

8

16

20

20

FDD

CA_66A-66A-70C-71A

71

8

16

20

20

FDD

CA_66C-70A-71A

71

8

16

20

FDD

CA_66C-70C-71A

71

8

16

20

20

FDD

CA_70A-71A

71

8

16

20

FDD

CA_70C-71A

71

8

16

20

20

FDD

NOTE 1: refers to the UL resource blocks, which shall be centred within the transmission bandwidth configuration for the channel bandwidth

NOTE 2: the UL configuration applies regardless of the channel bandwidth of the low band unless the UL resource blocks exceed that specified in Table 7.3.3-2 for the uplink bandwidth in which case the allocation according to Table 7.3.3-2 applies.

NOTE 3: refers to the UL resource blocks shall be located between 2373-2400MHz.

NOTE 4: These configurations apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 5: These configurations apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a high band.

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0bA, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by the uplink being active within a specified frequency range as noted in Table 7.3A.0-0bA. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-0bA and Table 7.3A.0-0bB.

Table 7.3A.0-0bA: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions for two bands due to close proximity of UL to DL channel)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A4

39

[-95.7]

-94

-91.5

-90

-89

FDD

CA_1A-3A5

3

-98.7

-97

-94

-92.2

-91

FDD

CA_1A-1A-3A4

39

-94

-91.5

-90

-89

FDD

CA_1A-1A-3A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A4

39

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3C4

39

-94

-91.5

-90

-89

FDD

CA_1A-3C5

3

-97

-94

-92.2

-91

FDD

CA_1A-1A-3C4

39

-94

-91.5

-90

-89

FDD

CA_1A-1A-3C5

3

-97

-94

-92.2

-91

FDD

CA_1C-3A4

39

-94

-91.5

-90

-89

FDD

CA_1C-3A5

3

-97

-94

-92.2

-91

FDD

CA_18A-28A6

28

-94

-92.5

FDD

CA_19A-28A7

28

-94

-92

FDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in Band 3, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 5: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in Band 3, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 6: These requirements apply when the uplink is active in Band 18 and the downlink channels in Band 28 are confined within the restricted frequency range specified for this CA configuration (Table 5.2A-2). For each channel bandwidth in Band 28, the requirement applies regardless of channel bandwidth in Band 18.

NOTE 7: These requirements apply when the uplink is active in Band 19 and the downlink channels in Band 28 are allocated at the middle of the restricted frequency range specified for this CA configuration (Table 5.2A-2). For each channel bandwidth in Band 28, the requirement applies regardless of channel bandwidth in Band 19.

NOTE 8: Void

NOTE 9: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

Table 7.3A.0-0bB: Uplink configuration for the uplink band (exceptions for two bands due to close proximity of UL to DL channel)

E-UTRA Band / Channel bandwidth of the affected DL band / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A1, 2

1

25

25

25

25

FDD

CA_1A-3A1, 3

1

25

45

45

45

FDD

CA_1A-1A-3A1, 2

1

25

25

25

25

FDD

CA_1A-1A-3A1, 3

1

25

45

45

45

FDD

CA_1A-3C1, 2

1

25

25

25

25

FDD

CA_1A-3C1, 3

1

25

45

45

45

FDD

CA_1A-1A-3C1, 2

1

25

25

25

25

FDD

CA_1A-1A-3C1, 3

1

25

45

45

45

FDD

CA_1C-3A1, 2

1

25

25

25

25

FDD

CA_1C-3A1, 3

1

25

45

45

45

FDD

CA_18A-28A4

18

18

18

FDD

CA_19A-28A4

19

18

18

FDD

NOTE 1: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 3 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1) in the uplink channel in Band 1.

NOTE 2: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz

NOTE 3: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz.

NOTE 4: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 28 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0bC, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by the uplink being active within a specified frequency range as noted in Table 7.3A.0-0bC. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-0bC and Table 7.3A.0-0bD.

Table 7.3A.0-0bC: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions for three bands due to close proximity of UL to DL channel)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A-5A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-5A5

3

-97

-94

-92.2

-91

FDD

CA_1A-1A-3A-5A4

312

-94

-91.5

-90

-89

FDD

CA_1A-1A-3A-5A5

3

-97

-94

-92.2

-91

FDD

CA_1A-1A-3C-5A4

312

-94

-91.5

-90

-89

FDD

CA_1A-1A-3C-5A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-5A4

39

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A-5A5

3

-97

-94

-92.2

-91

FDD

CA_1C-3A-5A4

312

-94

-91.5

-90

-89

FDD

CA_1C-3A-5A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-7A-7A

34,12

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3C-5A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3C-5A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-7A9

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-7A10

3

-97

-94

-92.2

-91

FDD

CA_1A-1A-3A-7A9

312

-94

-91.5

-90

-89

FDD

CA_1A-1A-3A-7A10

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-7A

39,12

-94

-91.5

-90

-89

FDD

310

-97

-94

-92.2

-91

CA_1A-3A-7A-7A

39,12

-94

-91.5

-90

-89

FDD

310

-97

-94

-92.2

-91

CA_1A-3A-7C9

312

-91.5

-90

-89

FDD

CA_1A-3A-3A-7C9

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-7C10

3

-94

-92.2

-91

FDD

CA_1A-3A-3A-7C10

3

-97

-94

-92.2

-91

FDD

CA_1A-3C-7A9

312

-94

-91.5

-90

-89

FDD

CA_1A-3C-7A10

3

-97

-94

-92.2

-91

FDD

CA_1A-1A-3C-7A9

312

-94

-91.5

-90

-89

FDD

CA_1A-1A-3C-7A10

3

-97

-94

-92.2

-91

FDD

CA_1A-3C-7C

39,12

-94

-91.5

-90

-89

FDD

310

-97

-94

-92.2

-91

CA_1A-3A-8A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-8A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-8A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A-8A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3C-8A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3C-8A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-11A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-11A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-19A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-19A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-19A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A-19A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-20A4

CA_1A-3A-3A-20A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-20A5

CA_1A-3A-3A-20A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3C-20A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3C-20A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-21A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-21A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-3A-21A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A-21A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-26A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-26A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-28A4

CA_1A-1A-3A-28A4

CA_1A-3A-3A-28A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-28A5

CA_1A-1A-3A-28A5

CA_1A-3A-3A-28A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3C-28A4

312

-94

-91.5

-90

-89

FDD

CA_1A-3C-28A5

3

-97

-94

-92.2

-91

FDD

CA_1A-3A-40A

34,12

-94

-91.5

-90

-89

FDD

35

 

 

-97

-94

-92.2

-91

40

[-93.4]

-91.3

-90

-88.9

TDD

CA_1A-3A-40C

34,12

-94

-91.5

-90

-89

FDD

35

 

 

-97

-94

-92.2

-91

40

[-93.4]

-91.3

-90

-88.9

TDD

CA_1A-3C-40A

34,12

-94

-91.5

-90

-89

FDD

35

 

 

-97

-94

-92.2

-91

40

[-93.4]

-91.3

-90

-88.9

TDD

CA_1A-3C-40C

34,12

-94

-91.5

-90

-89

FDD

35

 

 

-97

-94

-92.2

-91

40

[-93.4]

-91.3

-90

-88.9

TDD

CA_1A-3A-42A4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42A5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-3A-42A4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-3A-42A5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-42A-42A4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42A-42A5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-42A-42C4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42A-42C5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-42C4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42C5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-3A-42C4

312

-94

-91.5

-90

-89

FDD

CA_1A-3A-3A-42C5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-42C-42C4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42C-42C5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-42D4

312

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-42D5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-18A-28A6

28

-94

-92.5

FDD

CA_1A-19A-28A8

28

-94

-92

FDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in the Bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 5: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in the Bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 6: These requirements apply when the uplink is active in Band 18 and the downlink channels in Band 28 are confined within the restricted frequency range specified for this CA configuration (Table 5.2A-2). For each channel bandwidth in Band 28, the requirement applies regardless of channel bandwidth in Band 18.

NOTE 7: Void

NOTE 8: These requirements apply when the uplink is active in Band 19 and the downlink channels in Band 28 are allocated at the middle of the restricted frequency range specified for this CA configuration (Table 5.5A-2). For each channel bandwidth in Band 28, the requirement applies regardless of channel bandwidth in Band 19.

NOTE 9: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in Band 3 and Band 7, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 10: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in Band 3 and Band 7, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 11: Void

NOTE 12: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

Table 7.3A.0-0bD: Uplink configuration for the uplink band (exceptions for three bands due to close proximity of UL to DL channel)

E-UTRA Band / Channel bandwidth of the affected DL band / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A-5A1, 2

1

25

25

25

25

FDD

CA_1A-3A-5A1, 3

1

25

45

45

45

FDD

CA_1A-1A-3A-5A1, 2

1

25

25

25

25

FDD

CA_1A-1A-3A-5A1, 3

1

25

45

45

45

FDD

CA_1C-3A-5A1, 2

1

25

25

25

25

FDD

CA_1C-3A-5A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-7A-7A

11,2

25

25

25

25

FDD

11,3

25

45

45

45

FDD

CA_1A-3C-5A1, 2

1

25

25

25

25

FDD

CA_1A-3C-5A1, 3

1

25

45

45

45

FDD

CA_1A-3A-7A1, 2

1

25

25

25

25

FDD

CA_1A-3A-7A1, 3

1

25

45

45

45

FDD

CA_1A-1A-3A-7A1, 2

1

25

25

25

25

FDD

CA_1A-1A-3A-7A1, 3

1

25

45

45

45

FDD

CA_1A-1A-3C-7A1, 2

1

25

25

25

25

FDD

CA_1A-1A-3C-7A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-7A1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-7C1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-7A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-7C1, 3

1

25

45

45

45

FDD

CA_1A-3A-7A-7A1, 2

1

25

25

25

25

FDD

CA_1A-3A-7A-7A1, 3

1

25

45

45

45

FDD

CA_1A-3C-7A1, 2

1

25

25

25

25

FDD

CA_1A-3C-7A1, 3

1

25

45

45

45

FDD

CA_1A-3A-7C1, 2

1

25

25

25

25

FDD

CA_1A-3A-7C1, 3

1

25

45

45

45

FDD

CA_1A-3C-7C1, 2

1

25

25

25

25

FDD

CA_1A-3C-7C1, 3

1

25

45

45

45

FDD

CA_1A-3A-8A1, 2

1

25

25

25

25

FDD

CA_1A-3A-8A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-8A1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-8A1, 3

1

25

45

45

45

FDD

CA_1A-3C-8A1, 2

1

25

25

25

25

FDD

CA_1A-3C-8A1, 3

1

25

45

45

45

FDD

CA_1A-3A-11A1, 2

1

25

25

25

25

FDD

CA_1A-3A-11A1, 3

1

25

45

45

45

FDD

CA_1A-3A-19A1, 2

1

25

25

25

25

FDD

CA_1A-3A-19A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-19A1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-19A1, 3

1

25

45

45

45

FDD

CA_1A-3A-20A1, 2

CA_1A-3A-3A-20A1, 2

1

25

25

25

25

FDD

CA_1A-3A-20A1, 3

CA_1A-3A-3A-20A1, 3

1

25

45

45

45

FDD

CA_1A-3C-20A1, 2

1

25

25

25

25

FDD

CA_1A-3C-20A1, 3

1

25

45

45

45

FDD

CA_1A-3A-21A1, 2

1

25

25

25

25

FDD

CA_1A-3A-21A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-21A1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-21A1, 3

1

25

45

45

45

FDD

CA_1A-3A-26A1, 2

1

25

25

25

25

FDD

CA_1A-3A-26A1, 3

1

25

45

45

45

FDD

CA_1A-3A-28A1, 2

CA_1A-1A-3A-28A1, 2

CA_1A-3A-3A-28A1, 2

1

25

25

25

25

FDD

CA_1A-3A-28A1, 3

CA_1A-1A-3A-28A1, 3

CA_1A-3A-3A-28A1, 3

1

25

45

45

45

FDD

CA_1A-3C-28A1, 2

1

25

25

25

25

FDD

CA_1A-3C-28A1, 3

1

25

45

45

45

FDD

CA_1A-3A-40A

CA_1A-3A-40C

CA_1A-3C-40A

CA_1A-3C-40C

11,2

25

25

25

25

FDD

11,3

25

45

45

45

FDD

CA_1A-3A-42A1, 2

1

25

25

25

25

FDD

CA_1A-3A-42A1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-42A1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-42A1, 3

1

25

45

45

45

FDD

CA_1A-3A-42A-42A1, 2

1

25

25

25

25

FDD

CA_1A-3A-42A-42A1, 3

1

25

45

45

45

FDD

CA_1A-3A-42A-42C1, 2

1

25

25

25

25

FDD

CA_1A-3A-42A-42C1, 3

1

25

45

45

45

FDD

CA_1A-3A-42C1, 2

1

25

25

25

25

FDD

CA_1A-3A-42C1, 3

1

25

45

45

45

FDD

CA_1A-3A-42C-42C1, 2

1

25

25

25

25

FDD

CA_1A-3A-42C-42C1, 3

1

25

45

45

45

FDD

CA_1A-3A-42D1, 2

1

25

25

25

25

FDD

CA_1A-3A-42D1, 3

1

25

45

45

45

FDD

CA_1A-3A-3A-42C1, 2

1

25

25

25

25

FDD

CA_1A-3A-3A-42C1, 3

1

25

45

45

45

FDD

CA_1A-18A-28A4

18

18

18

FDD

CA_1A-19A-28A4

19

18

18

FDD

NOTE 1: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 3 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1) in the uplink channel in Band 1.

NOTE 2: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz.

NOTE 3: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz.

NOTE 4: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 28 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0bD1, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by the uplink being active within a specified frequency range as noted in Table 7.3A.0-0bD1. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-0bD1 and Table 7.3A.0-0bD2.

Table 7.3A.0-0bD1: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions for four bands due to close proximity of UL to DL channel)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A-5A-7A

CA_1A-3A-3A-5A-7A

CA_1A-3A-5A-7A-7A

34,9

-91.5

-90

-89

FDD

35

-94

-92.2

-91

CA_1A-3A-5A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-5A-40A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

40

-91.9

-90.4

-89.4

TDD

CA_1A-3A-5A-41A7,8

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

41

[88.1]

TDD

CA_1A-3C-7A-8A

CA_1A-3A-3A-7A-8A

CA_1A-3A-7A-7A-8A

CA_1A-3A-3A-7A-7A-8A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3C-7A-20A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-7A-26A

34,9

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-8A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-20A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-3A-7A-20A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

FDD

CA_1A-3A-7A-26A

34,9

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-28A

34,9

[-91.5]

[-90]

[-89]

FDD

35

-94

-92.2

-91

CA_1A-3A-7C-28A

34,9

[-91.5]

[-90]

[-89]

FDD

35

-94

-92.2

-91

CA_1A-3A-7A-38A

CA_1A-3C-7A-38A

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-7A-42A

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-8A-11A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-8A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-8A-38A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-11A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-8A-40A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

40

[-93.4]

-91.9

-90.4

-89.4

TDD

CA_1A-3A-18A-42A

CA_1A-3A-18A-42C

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-19A-21A4

39

-93.7

-91.2

-89.7

-88.7

FDD

CA_1A-3A-19A-21A5

3

-96.7

-93.7

-91.9

-90.7

FDD

CA_1A-3A-3A-19A-21A4

39

-93.7

-91.2

-89.7

-88.7

FDD

CA_1A-3A-3A-19A-21A5

3

-96.7

-93.7

-91.9

-90.7

FDD

CA_1A-3A-7A-40C4

39

-94

-91.5

-90

-89

FDD

40

-92.6

-90.5

-89.2

-88.1

TDD

CA_1A-3A-7A-40C5

3

-97

-94

-92.2

-91

FDD

40

-92.6

-90.5

-89.2

-88.1

TDD

CA_1A-3A-19A-42A

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-19A-42C

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-20A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-3A-20A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

FDD

CA_1A-3A-20A-42A

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-20A-43A

34,9

-94

-91.5

-90

FDD

35

-97

-94

-92.2

CA_1A-3A-21A-28A4

39

-93.7

-91.2

-89.7

-88.7

FDD

CA_1A-3A-21A-28A5

3

-96.7

-93.7

-91.9

-90.7

FDD

CA_1A-3A-21A-42A4

39

-93.7

-91.2

-89.7

-88.7

FDD

CA_1A-3A-21A-42A5

3

-96.7

-93.7

-91.9

-90.7

FDD

CA_1A-3A-21A-42C

34,9

-93.7

-91.2

-89.7

-88.7

FDD

35

-96.7

-93.7

-91.9

-90.7

CA_1A-3A-28A-40A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

40

[-93.4]

-91.9

-90.4

-89.4

TDD

CA_1A-3A-28A-40C

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

40

-92.6

-90.5

-89.2

-88.1

TDD

CA_1A-3A-28A-42A4

39

-93.8

-91.3

-89.8

-88.8

FDD

CA_1A-3A-28A-42A5

3

-96.8

-93.8

-92

-90.8

FDD

CA_1A-3A-28A-42C

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-32A-42A

34,9

-93.8

-91.3

-89.8

FDD

35

-96.8

-93.8

-92

CA_1A-3A-32A-43A

34,9

-94

-91.5

-90

FDD

35

-97

-94

-92.2

CA_1A-3A-41A-42A

CA_1A-3A-41C-42A

CA_1A-3A-41A-42C

CA_1A-3A-41C-42C

34,9

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-42A-43A

34,9

-93.8

-91.3

-89.8

FDD

35

-96.8

-93.8

-92

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in the bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 5: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in the bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 6: Void

NOTE 7: The Band 41 requirements are modified by -0.5dB when carrier frequency of the assigned E-UTRA channel bandwidth is within 2545-2690MHz.

NOTE 8: The Band 41 requirements also apply to the supported CA_1A-41A.

NOTE 9: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

Table 7.3A.0-0bD2: Uplink configuration for the low band (exceptions for four bands due to close proximity of UL to DL channel)

E-UTRA Band / Channel bandwidth of the affected DL band / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A-5A-7A

CA_1A-3A-3A-5A-7A

CA_1A-3A-5A-7A-7A

CA_1A-3A-5A-28A

CA_1A-3A-5A-40A

CA_1A-3A-5A-41A

CA_1A-3A-7A-7A-26A

CA_1A-3A-7A-8A

CA_1A-3C-7A-8A

CA_1A-3A-3A-7A-8A

CA_1A-3A-7A-7A-8A

CA_1A-3A-3A-7A-7A-8A

CA_1A-3A-7A-20A

CA_1A-3C-7A-20A

CA_1A-3A-3A-7A-20A

CA_1A-3A-7A-26A

CA_1A-3A-7A-28A

CA_1A-3A-7C-28A

CA_1A-3A-7A-38A

CA_1A-3C-7A-38A

CA_1A-3A-7A-40C

CA_1A-3A-7A-42A

CA_1A-3A-8A-11A

CA_1A-3A-8A-28A

CA_1A-3A-8A-38A

CA_1A-3A-11A-28A

CA_1A-3A-8A-40A

CA_1A-3A-18A-42A

CA_1A-3A-18A-42C

CA_1A-3A-19A-21A

CA_1A-3A-3A-19A-21A

CA_1A-3A-19A-42A

CA_1A-3A-19A-42C

CA_1A-3A-20A-28A

CA_1A-3A-3A-20A-28A

CA_1A-3A-20A-42A

CA_1A-3A-20A-43A

CA_1A-3A-21A-28A

CA_1A-3A-21A-42A

CA_1A-3A-21A-42C

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

CA_1A-3A-28A-42A

CA_1A-3A-32A-42A

CA_1A-3A-32A-43A

CA_1A-3A-41A-42A

CA_1A-3A-41C-42A

CA_1A-3A-41A-42C

CA_1A-3A-41C-42C

CA_1A-3A-42A-43A

11,2

25

25

25

25

FDD

11,3

25

45

45

45

NOTE 1: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 3 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1) in the uplink channel in Band 1.

NOTE 2: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz

NOTE 3: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz.

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0bD3, exceptions are allowed when the uplink is active within a specified frequency range as noted in Table 7.3A.0-0bD3. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-0bD3 and Table 7.3A.0-0bD4.

Table 7.3.0-0bD3: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions for five bands due to close proximity of UL to DL channel)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A-5A-7A-28A

34,9

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-8A-20A

34,7

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-20A-28A

34,7

-94

-91.5

-90

-89

FDD

35

-97

-94

-92.2

-91

CA_1A-3A-7A-20A-42A

34,7

-93.8

-91.3

-89.8

-88.8

FDD

35

-96.8

-93.8

-92

-90.8

CA_1A-3A-20A-32A-42A

34,7

-93.8

-91.3

-89.8

FDD

35

-96.8

-93.8

-92

CA_1A-3A-20A-32A-43A

34,7

-94

-91.5

-90

FDD

35

-97

-94

-92.2

CA_1A-3A-32A-42A-43A

34,7

-93.8

-91.3

-89.8

FDD

35

-96.8

-93.8

-92

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in the bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 5: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in the bands other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 6: Void

NOTE 7: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

Table 7.3.0-0bD4: Uplink configuration for the low band (exceptions for five bands due to close proximity of UL to DL channel)

E-UTRA Band / Channel bandwidth / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A-5A-7A-28A

CA_1A-3A-7A-8A-20A

CA_1A-3A-7A-20A-28A

CA_1A-3A-7A-20A-42A

CA_1A-3A-20A-32A-42A

CA_1A-3A-20A-32A-43A

CA_1A-3A-32A-42A-43A

11,2

25

25

25

25

FDD

11,3

25

45

45

45

NOTE 1: refers to the UL resource blocks shall be located as close as possible to the downlink channel in Band 3 but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1) in the uplink channel in Band 1.

NOTE 2: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz.

NOTE 3: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz.

For the UE that supports any of the E-UTRA CA configurations given in Table 7.3A.0-0bE, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by the uplink being active in the applicable active UL bands of the same CA configuration in Table 7.3A.0-0bE. For these exceptions, the UE shall meet the reference sensitivities specified in Table 7.3A.0-0bE and Table 7.3A.0-0bF.

Table 7.3A.0-0bE: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions due to cross band isolation issues of TDD and FDD bands)

EUTRA CA Configuration

EUTRA band

Channel bandwidth

Duplex mode

Applicable active UL band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

CA_1A-3A-5A-40A

4019

-92.9

-91.3

-90.2

TDD

3

CA_1A-3A-5A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-3A-5A-41A5

41

[-88.1]

TDD

3

CA_1A-3A-7A-20A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

CA_1A-3A-7A-20A-42A

719

-93

-91.3

-90.1

FDD

42

CA_1A-3A-7A-38A

CA_1A-3C-7A-38A

719

-93.3

-90.7

-89.2

-88.1

FDD

1

3819

-93.3

-90.7

-89.2

-88.1

TDD

CA_1A-3A-7A-38A

CA_1A-3C-7A-38A

719

-93.3

-90.7

-89.2

-88.1

FDD

3

3819

-93.3

-90.7

-89.2

-88.1

TDD

CA_1A-3A-7A-40A15

319

-94

-91.5

-90

-89

FDD

1

4019

-92.6

-90.5

-89.2

-88.1

TDD

CA_1A-3A-7A-40A16

3

-97

-94

-92.2

-91

FDD

1

4019

-92.6

-90.5

-89.2

-88.1

TDD

CA_1A-3A-7A-40A

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_1A-3A-7A-40A

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-3A-7A-40A

119

-91.7

-89.5

-87.9

-86.9

FDD

40

319

-94.2

-91.2

-89.5

-88.3

719

-94

-92.4

-91.2

CA_1A-3A-7A-40C

40

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_1A-3A-7A-40C

40

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-3A-7A-40C

1

-91.7

-89.5

-87.9

-86.9

FDD

40

3

-94.2

-91.2

-89.5

-88.3

7

-94

-92.4

-91.2

CA_1A-3A-7A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

719

-93

-91.3

-90.1

FDD

42

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-3A-8A-40A

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_1A-3A-8A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

28

-96.8

-94.1

-92.5

-89.8

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_1A-3A-38A12

CA_1A-3C-38A12

319

-94

-91.5

-90

-89

FDD

1

38

-97.1

-94.4

-92.8

-91.7

TDD

38

-97.1

-94.4

-92.8

-91.7

TDD

3

119

-98.1

-95.1

-93.3

-92.1

FDD

38

319

-95.1

-92.1

-90.3

-89.1

CA_1A-3A-38A13

CA_1A-3C-38A13

3

-97

-94

-92.2

-91

FDD

1

38

-97.1

-94.4

-92.8

-91.7

TDD

38

-97.1

-94.4

-92.8

-91.7

TDD

3

119

-98.1

-95.1

-93.3

-92.1

FDD

38

319

-95.1

-92.1

-90.3

-89.1

CA_1A-3A-40A

4019

-100

-92.9

-91.3

-90.2

TDD

3

CA_1A-3A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-3A-40C

4019

-100

-92.9

-91.3

-90.2

TDD

3

CA_1A-3A-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-3C-40A

4019

-100

-92.9

-91.3

-90.2

TDD

3

CA_1A-3C-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-3A-41A12,14

CA_1A-3A-41C12,14

CA_1A-3A-41D12,14

319

-94

-91.5

-90

-89

FDD

1

4119

-93.3

-90.7

-89.2

-88.1

TDD

4119

-93.3

-90.7

-89.2

-88.1

TDD

3

CA_1A-3A-41A13,14

CA_1A-3A-41C13,14

CA_1A-3A-41D13,14

3

-97

-94

-92.2

-91

FDD

1

4119

-93.3

-90.7

-89.2

-88.1

TDD

4119

-93.3

-90.7

-89.2

-88.1

TDD

3

CA_1A-3A-41A-42A12,14

CA_1A-3A-41A-42C12,14

CA_1A-3A-41C-42A12,14

CA_1A-3A-41C-42C12,14

319

-94

-91.5

-90

-89

FDD

1

4119

-93.3

-90.7

-89.2

-88.1

TDD

4119

-93.3

-90.7

-89.2

-88.1

TDD

3

CA_1A-3A-41A-42A13,14

CA_1A-3A-41A-42C13,14

CA_1A-3A-41C-42A13,14

CA_1A-3A-41C-42C13,14

3

-97

-94

-92.2

-91

FDD

1

4119

-93.3

-90.7

-89.2

-88.1

TDD

4119

-93.3

-90.7

-89.2

-88.1

TDD

3

CA_1A-3C-40C

4019

-100

-92.9

-91.3

-90.2

TDD

3

CA_1A-3C-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

319

-94.2

-91.2

-89.5

-88.3

CA_1A-5A-40A

4019

-91.9

-90.4

-89.4

TDD

1

CA_1A-5A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

CA_1A-7A-8A-40A

4019

-92.6

-90.5

-89.2

-88.1

TDD

1

CA_1A-7A-8A-40A

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-7A-8A-40A

119

-91.7

-89.5

-87.9

-86.9

FDD

40

719

-94

-92.4

-91.2

CA_1A-7A-8A-40C

4019

-92.6

-90.5

-89.2

-88.1

TDD

1

CA_1A-7A-8A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-7A-8A-40C

119

-91.7

-89.5

-87.9

-86.9

FDD

40

719

-94

-92.4

-91.2

CA_1A-7A-20A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

CA_1A-7A-20A-42A

719

-96.2

-93.2

-91.5

-90.3

FDD

42

CA_1A-7A-28A-40A

CA_1A-7A-28A-40C

119

-91.7

-89.5

-87.9

-86.9

FDD

40

719

-96.8

-94

-92.4

-91.2

28

-96.8

-94.1

-92.5

-89.8

CA_1A-7A-28A-40A

CA_1A-7A-28A-40C

4019

-92.6

-90.5

-89.2

-88.1

TDD

1

CA_1A-7A-28A-40A

CA_1A-7A-28A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-7A-28A-40A

CA_1A-7A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_1A-7A-38A

719

-93.3

-90.7

-89.2

-88.1

FDD

1

38

-93.3

-90.7

-89.2

-88.1

TDD

CA_1A-7A-40A

4019

-92.6

-90.5

-89.2

-88.1

TDD

1

CA_1A-7A-40A

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-7A-40A

119

-91.7

-89.5

-87.9

-86.9

FDD

40

719

-94

-92.4

-91.2

CA_1A-7A-40C

4019

-92.6

-90.5

-89.2

-88.1

TDD

1

CA_1A-7A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_1A-7A-40C

119

-91.7

-89.5

-87.9

-86.9

FDD

40

719

-94

-92.4

-91.2

CA_1A-7A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

719

-96.2

-93.2

-91.5

-90.3

FDD

42

CA_1A-8A-40A

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-8A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

CA_1A-8A-40C

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-8A-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

CA_1A-28A-40A

CA_1A-28A-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

28

-96.8

-94.1

-92.5

-89.8

CA_1A-28A-40A

CA_1A-28A-40C

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-28A-40A

CA_1A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_1A-40A

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-40A

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

CA_1A-40C

4019

[-93.4]

-91.9

-90.4

-89.4

TDD

1

CA_1A-40C

119

-91.7

[-89.5]

[-87.9]

[-86.9]

FDD

40

CA_3A-5A-40A

4019

-92.9

-91.3

-90.2

TDD

3

CA_3A-5A-40A

319

[-95.3]

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-5A-41A5

41

[-88.1]

TDD

3

CA_3A-5A-41A5,18

3

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

41

-91.5

TDD

CA_3A-7A-8A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3A-7A-8A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

8

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3C-7A-8A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3C-7A-8A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

CA_3A-7A-8A-40A

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_3A-7A-8A-40A

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_3A-7A-8A-40C

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_3A-7A-8A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_3A-7A-8A-40A

319

-94.2

-91.2

-89.5

-88.3

FDD

40

719

-94

-92.4

-91.2

CA_3A-7A-8A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

719

-94

-92.4

-91.2

CA_3A-7A-28A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3A-7A-28A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

28

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3C-7A-28A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3C-7A-28A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3A-7A-28A-40A

CA_3A-7A-28A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

719

-96.8

-94

-92.4

-91.2

28

-96.8

-94.1

-92.5

-89.8

CA_3A-7A-28A-40A

CA_3A-7A-28A-40C

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

_3A-7A-28A-40A

CA_3A-7A-28A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_3A-7A-28A-40A

CA_3A-7A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_3A-7A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3C-7A-38A

719

[-93.8]

[-91.2]

[-89.7]

[-88.6]

FDD

3

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_3A-7A-40A

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_3A-7A-40A

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_3A-7A-40A

319

-94.2

-91.2

-89.5

-88.3

FDD

40

719

-96.8

-94

-92.4

-91.2

CA_3A-7A-40C

4019

-94.6

-92.1

-90.5

-89.4

TDD

3

CA_3A-7A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_3A-7A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

719

-96.8

-94

-92.4

-91.2

CA_3A-7A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

3

[-96.6]

[-93.6]

[-91.8]

[-90.6]

FDD

42

719

-96.2

-93.2

-91.5

-90.3

CA_3A-8A-40A

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-8A-40C

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-8A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-8A-40A

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-20A-32A

32

-99.5

-96.5

-94.7

-93.5

FDD

3

CA_3A-28A-40A

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-28A-40A

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-28A-40A

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_3A-28A-40C

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_3A-28A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

28

-96.8

-94.1

-92.5

-89.8

CA_3A-28A-40D

4019

-92.9

-91.3

-90.2

TDD

3

CA_3A-28A-40D

4019

-92.9

-91.4

-90.5

TDD

28

CA_3A-28A-40D

319

-94.2

-91.2

-89.5

-88.3

FDD

40

28

-96.8

-94.1

-92.5

-89.8

CA_3A-28A-41A5

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

CA_3A-28A-41C5

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

CA_3A-28A-41A-42A

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

41

-94.517

-92.717

-91.517

TDD

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3A-28A-41A-42C

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

41

-94.517

-92.717

-91.517

TDD

CA_3A-28A-41C-42A

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

41

-94.517

-92.717

-91.517

TDD

CA_3A-40A

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-40A

319

[-97.4]

[-95.3]

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-40A-40A

4019

-92.9

-90.2

TDD

3

CA_3A-40A-40A

319

-94.2

-91.2

FDD

40

CA_3A-40C

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-40D

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3A-40D

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-40E

4019

-91.3

-90.2

TDD

3

CA_3A-40E

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3C-40A

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3C-40A

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3C-40C

4019

-95.4

-92.9

-91.3

-90.2

TDD

3

CA_3C-40C

319

-94.2

-91.2

-89.5

-88.3

FDD

40

CA_3A-41A5

319

[-95.3]

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3A-41C5

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3A-41D5

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3A-3A-41A

3

[-95.3]

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

41

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3C-41A5

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3C-41C5

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3C-41D5

319

[-94]

[-91]

[-89.2]

[-87.9]

FDD

41

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

CA_3A-41A-42A5,6,7,8

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-71.7

-71.7

-71.7

-71.7

CA_3A-41A-42A5,6,9

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-97.1

-94.7

-93.2

-92.5

CA_3A-41A-42A5,6,10

319

[-93.5]

[-90.5]

[-88.7]

[-87.4]

FDD

41

CA_3A-41A-42C5,6,7,8

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-71.7

-71.7

-71.7

CA_3A-41A-42C5,6,9

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-94.7

-93.2

-92.5

CA_3A-41A-42C5,6,10

319

[-93.5]

[-90.5]

[-88.7]

[-87.4]

FDD

41

42

-95.5

-93.7

-92.5

TDD

CA_3A-41C-42A5,6,7,8

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-71.7

-71.7

-71.7

CA_3A-41C-42A5,6,9

4119

[-90.7]

[-89.2]

[-88.1]

TDD

3

42

-94.7

-93.2

-92.5

CA_3A-41C-42A5,6,10

319

[-93.5]

[-90.5]

[-88.7]

[-87.4]

FDD

41

CA_3A-41C-42C5,6,7,8

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-71.7

-71.7

-71.7

-71.7

CA_3A-41C-42C5,6,9

4119

[-93.3]

[-90.7]

[-89.2]

[-88.1]

TDD

3

4219

-97.1

-94.7

-93.2

-92.5

CA_3A-41C-42C5,6,10

319

[-93.5]

[-90.5]

[-88.7]

[-87.4]

FDD

41

CA_7A-8A-38A

719

[-91.2]

[-89.7]

[-88.6]

FDD

8

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_7A-8A-40A

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-88

-87.4

-87

-86.7

FDD

8

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-8A-40C

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-88

-87.4

-87

-86.7

FDD

8

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-20A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

719

-96.2

-93.2

-91.5

-90.3

FDD

42

CA_7A-28A-38A

719

[-91.2]

[-89.7]

[-88.6]

FDD

8

38

[-93.8]

[-91.2]

[-89.7]

[-88.6]

TDD

CA_7A-28A-40A

CA_7A-28A-40C

719

-96.8

-94

-92.4

-91.2

FDD

40

28

-96.8

-94.1

-92.5

-89.8

FDD

CA_7A-28A-40A

CA_7A-28A-40C

4019

-96

-93.3

-91.7

-90.6

TDD

7

CA_7A-28A-40A

CA_7A-28A-40C

4019

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_7A-40A

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-40C

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-40D

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-40E

4019

-96.3

-93.6

-92

-90.9

TDD

7

719

-97.1

-94.3

-92.7

-91.5

FDD

40

CA_7A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

719

-96.2

-93.2

-91.5

-90.3

FDD

42

CA_7A-42A-42A

4219

-95.6

-93

-91.5

-90.4

TDD

7

719

-96.2

-93.2

-91.5

-90.3

FDD

42

CA_25A-41A, CA_25A-25A-41A, CA_25A-41C, CA_25A-25A-41C, CA_25A-41D, CA_25A-25A-41D, CA_25A-41E, CA_25A-25A-41E, CA_25A-41F, CA_25A-25A-41F

25

[-95.9]

[-92.9]

[-91.1]

[-89.9]

FDD

41

CA_28A-40A

40

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_28A-40A

28

-96.8

-94.1

-92.5

-89.8

FDD

40

CA_28A-40C

40

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_28A-40C

28

-96.8

-94.1

-92.5

-89.8

FDD

40

CA_28A-40D

40

-95.1

-92.9

-91.4

-90.5

TDD

28

CA_28A-40D

28

-96.8

-94.1

-92.5

-89.8

FDD

40

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: These requirements apply regardless of the channel bandwidth and the location of UL band.

NOTE 5: The B41 requirements are modified by -0.5dB when carrier frequency of the assigned E-UTRA channel bandwidth is within 2545-2690 MHz.

NOTE 6: The antenna isolation for MSD calculation is assumed as 10 dB. For conducted mode REFSENS test such antenna isolation is not observed as the antennas are disconnected. Additionally antenna isolation assumption is under discussion depending on the frequency range

NOTE 7: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_3A-42A, CA_3A-42C, CA_3A-42D, CA_3A-3A-42C, CA_3A-42A-42C, CA_1A-3A-42A, CA_1A-3A-42C, CA_1A-3A-42D, CA_3A-19A-42A, CA_3A-19A-42C, CA_1A-3A-19A-42A, CA_3A-41A-42A, CA_3A-41A-42C, CA_3A-41C-42A, and CA_3A-41C-42C.

NOTE 8: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 9: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

NOTE 10: Only applicable for UE supporting inter-band carrier aggregation with uplink in one E-UTRA band and without simultaneous Rx/Tx.

NOTE 11: Void

NOTE 12: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in Band 3 and Band 41, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 13: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in Band 3 and Band 41, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 14: The B41 requirements also apply to the supported CA_1A-41A.

NOTE 15: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth other than Band 1, the requirement applies regardless of channel bandwidth in Band 1

NOTE 16: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth other than Band 1, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 17: The B41 requirements are modified by -0.1dB when carrier frequency of the assigned E-UTRA channel bandwidth is within 2545-2690 MHz.

NOTE 18: No requirements apply when there is at least one individual RE within the downlink transmission bandwidth of band5 for which the 3rd receiver harmonic is within the uplink transmission bandwidth of band41. The reference sensitivity is only verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 19: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

Table 7.3A.0-0bF: Uplink configuration for reference sensitivity (exceptions due to cross band isolation issues of TDD and FDD bands)

E-UTRA Band / Channel bandwidth of the affected DL band / NRB / Duplex mode

EUTRA CA Configuration

E-UTRA Band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex Mode

CA_1A-3A-5A-41A

3

25

50

501

501

FDD

CA_1A-3A-7A-20A-42A

7

25

50

75

751

FDD

42

25

50

75

100

TDD

CA_1A-3A-7A-38A

CA_1A-3C-7A-38A

1

25

50

75

100

FDD

3

25

50

501

501

FDD

CA_1A-3A-7A-40A

CA_1A-3A-7A-40C

11,3

25

25

25

25

FDD

11,4

25

45

45

45

FDD

3

25

50

501

501

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_1A-3A-7A-42A

7

25

50

75

751

FDD

42

25

50

75

100

TDD

CA_1A-3A-28A-40A

CA_1A-3A-28A-40C

1

25

50

75

100

FDD

3

25

50

501

501

FDD

28

25

251

251

251

FDD

40

25

50

75

100

TDD

CA_1A-3A-38A

CA_1A-3C-38A

11,3

25

25

25

25

FDD

11,4

25

45

45

45

FDD

3

25

50

501

501

FDD

38

25

50

75

100

TDD

CA_1A-3A-41A

CA_1A-3A-41C

CA_1A-3A-41D

1

253

251,3

251,3

251,3

FDD

254

451,4

451,4

451,4

FDD

3

25

50

501

501

FDD

CA_1A-3A-41A-42A

CA_1A-3A-41A-42C

CA_1A-3A-41C-42A

CA_1A-3A-41C-42C

1

253

251,3

251,3

251,3

FDD

254

451,4

451,4

451,4

FDD

3

25

50

501

501

FDD

CA_1A-5A-40A

1

25

50

75

100

FDD

40

25

50

75

100

TDD

CA_1A-7A-8A-40A

1

25

50

75

100

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_1A-7A-8A-40C

1

25

50

75

100

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_1A-7A-28A-40A

CA_1A-7A-28A-40C

1

25

50

75

100

FDD

7

25

50

75

751

FDD

28

25

251

251

251

FDD

40

25

50

75

100

TDD

CA_1A-8A-40A

1

25

50

75

100

FDD

40

25

50

75

100

TDD

CA_1A-8A-40C

1

25

50

75

100

FDD

40

25

50

75

100

TDD

CA_1A-7A-20A-42A

1

25

50

75

100

FDD

7

25

50

75

751

FDD

20

25

201

205

205

FDD

42

25

50

75

100

TDD

CA_1A-7A-38A

1

25

45

451

451

FDD

CA_1A-7A-40A

1

25

50

75

100

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_1A-7A-40C

1

25

50

75

100

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_1A-7A-42A

1

25

50

75

100

FDD

7

25

50

75

751

FDD

42

25

50

75

100

TDD

CA_1A-40A

1

25

50

75

100

FDD

40

25

50

75

100

TDD

CA_1A-28A-40A

CA_1A-28A-40C

1

25

50

75

100

FDD

28

25

251

251

251

FDD

40

25

50

75

100

TDD

CA_3A-5A-41A

3

25

50

501

501

FDD

41

100

TDD

CA_3A-7A-8A-38A

3

25

50

501

501

FDD

CA_3C-7A-8A-38A

3

25

50

501

501

FDD

CA_3A-7A-8A-40A

3

25

50

501

501

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_3A-7A-8A-40C

3

25

50

501

501

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_3A-7A-28A-38A

3

25

50

501

501

FDD

CA_3C-7A-28A-38A

3

25

50

501

501

FDD

CA_3A-7A-28A-40A

CA_3A-7A-28A-40C

3

25

50

501

501

FDD

7

25

50

75

751

FDD

28

25

251

251

251

FDD

40

25

50

75

100

TDD

CA_3A-7A-38A

3

25

50

501

501

FDD

CA_3C-7A-38A

3

25

50

501

501

FDD

CA_3A-7A-40A

3

25

50

501

501

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_3A-7A-40C

3

25

50

501

501

FDD

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_3A-7A-42A

7

25

50

75

751

FDD

42

25

50

75

100

TDD

CA_3A-8A-40A

3

6

15

25

50

501

501

FDD

40

25

50

75

100

TDD

CA_3A-8A-40C

3

6

15

25

50

501

501

FDD

40

25

50

75

100

TDD

CA_3A-28A-41A

3

25

50

501

501

FDD

28

25

251

251

251

FDD

41

25

50

75

100

TDD

CA_3A-28A-41C

3

25

50

501

501

FDD

28

25

251

251

251

FDD

41

25

50

75

100

TDD

CA_3A-28A-41A-42A

3

25

50

501

501

FDD

28

25

251

FDD

41

50

75

100

TDD

42

50

75

100

TDD

CA_3A-28A-41A-42C

3

25

50

501

501

FDD

41

50

75

100

TDD

CA_3A-28A-41C-42A

3

25

50

501

501

FDD

41

50

75

100

TDD

CA_3A-40A

CA_3A-40C

CA_3A-40D

CA_3A-40E

CA_1A-3A-40A

CA_1A-3C-40A

CA_1A-3A-40C

CA_1A-3C-40C

CA_3A-5A-40A

CA_3A-28A-40A

CA_3A-28A-40C

CA_1A-3A-5A-40A

CA_1A-3A-8A-40A

3

6

15

25

50

501

501

FDD

40

25

50

75

100

TDD

CA_3A-40A-40A

3

25

50

FDD

40

50

100

TDD

CA_3A-41A

CA_3A-3A-41A

3

15

25

50

501

501

FDD

41

25

50

75

100

TDD

CA_3A-41C

CA_3C-41A

CA_3C-41D

3

25

50

501

501

FDD

41

25

50

75

100

TDD

CA_3A-41D

3

25

50

501

501

FDD

41

25

50

75

100

TDD

CA_3C-41C

3

25

50

501

501

FDD

41

25

50

75

100

TDD

CA_3A-41A-42A

3

25

50

501

501

FDD

41

25

50

75

100

TDD

CA_7A-8A-38A

8

25

50

FDD

CA_7A-8A-40A

7

25

50

75

751

FDD

8

8

16

40

25

50

75

100

TDD

CA_7A-8A-40C

7

25

50

75

751

FDD

8

8

16

40

25

50

75

100

TDD

CA_7A-20A-42A

7

25

50

75

751

FDD

20

25

50

75

100

42

25

50

75

100

TDD

CA_7A-28A-38A

28

25

50

501

501

FDD

CA_7A-28A-40A

CA_7A-28A-40C

7

25

50

75

751

FDD

28

25

251

251

251

40

25

50

75

100

TDD

CA_7A-40A

CA_7A-40C

CA_7A-40D

CA_7A-40E

7

25

50

75

751

FDD

40

25

50

75

100

TDD

CA_7A-42A,

CA_7A-42A-42A

7

25

50

75

751

FDD

42

25

50

75

100

TDD

CA_25A-41A

CA_25A-41C

CA_25A-41D

CA_25A-41E

CA_25A-41F

CA_25A-25A-41A

CA_25A-25A-41C

CA_25A-25A-41D

CA_25A-25A-41E

CA_25A-25A-41F

25

25

50

75

100

FDD

41

25

50

75

100

TDD

CA_28A-40A,

CA_28A-40C

28

25

251

251

251

FDD

40

25

50

75

100

TDD

NOTE 1: refers to the UL resource blocks shall be located as close as possible to the downlink operating band but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

NOTE 2: the UL configuration applies regardless of the channel bandwidth of the low band unless the UL resource blocks exceed that specified in Table 7.3.3-2 for the uplink bandwidth in which case the allocation according to Table 7.3.3-2 applies.

NOTE 3: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz.

NOTE 4: UL allocation when the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz.

NOTE 5: refers to Band 20; in the case of 15MHz channel bandwidth, the UL resource blocks shall be located at RBstart 11 and in the case of 20MHz channel bandwidth, the UL resource blocks shall be located at RBstart 16

For band combinations including operating bands without uplink band (as noted in Table 5.2-1), the requirements are specified in Table 7.3A.0-0d and for any uplink band with uplink configuration specified in Table 7.3.3-2.

Table 7.3A.0-0d: Reference sensitivity QPSK PREFSENS (CA with a SDL band)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz

(dBm)

3 MHz

(dBm)

5 MHz

(dBm)

10 MHz

(dBm)

15 MHz

(dBm)

20 MHz

(dBm)

Duplex mode

CA_1A-3A-7A-20A-32A

1

-100

-97

-95.2

-94

FDD

35,6

-94

-91

-90

-89

37

-97

-94

-92.2

-91

7

-95

-93.2

-92

20

-97

-94

-91.2

-90

32

-100

-97

-95.2

-94

CA_1A-3A-20A-32A6

1

-100

-97

-95.2

-94

FDD

3

-94

-91.5

-90

-89

20

-97

-94

-91.2

-90

32

-100

-97

-95.2

-94

CA_1A-3A-20A-32A-42A

1

-100

-97

-95.2

FDD

3

-97

-94

-92.2

FDD

20

-97

FDD

32

-99.5

-96.5

-94.7

-93.5

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-3A-20A-32A-43A

1

-100

-97

-95.2

FDD

3

-97

-94

-92.2

FDD

20

-97

FDD

32

-99.5

-96.5

-94.7

-93.5

FDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-3A-20A-32A7

1

-100

-97

-95.2

-94

FDD

3

-97

-94

-92.2

-91

20

-97

-94

-91.2

-90

32

-100

-97

-95.2

-94

CA_1A-3A-32A6

1

-100

-97

-95.2

-94

FDD

3

-94

-91.5

-90

-89

32

-100

-97

-95.2

-94

CA_1A-3A-32A7

1

-100

-97

-95.2

-94

FDD

3

-97

-94

-92.2

-91

32

-100

-97

-95.2

-94

CA_1A-3A-7A-32A6

1

-100

-97

-95.2

-94

FDD

3

-94

-91.5

-90

-89

7

-98

-95

-93.2

-92

32

-100

-97

-95.2

-94

CA_1A-3A-7A-32A7

1

-100

-97

-95.2

-94

FDD

3

-97

-94

-92.2

-91

7

-98

-95

-93.2

-92

32

-100

-97

-95.2

-94

CA_1A-3A-32A-42A7

1

-99.8

-96.8

-95

FDD

3

-96.8

-93.8

-92

32

-99.5

-96.5

-94.7

-93.5

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-3A-32A-43A7

1

-100

-97

-95.2

FDD

3

-97

-94

-92.2

32

-99.5

-96.5

-94.7

-93.5

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-3A-32A-42A-43A

1

-99.8

-96.8

-95

FDD

3

-96.8

-93.8

-92

FDD

32

-99.5

-96.5

-94.7

-93.5

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-20A-32A-42A

1

-100

-97

-95.2

FDD

20

-97

32

-100

-97

-95.2

-94

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-20A-32A-43A

1

-100

-97

-95.2

FDD

20

-97

32

-100

-97

-95.2

-94

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-32A

1

-100

-97

-95.2

-94

FDD

32

-100

-97

-95.2

-94

CA_1A-32A-42A

1

-100

-97

-95.2

FDD

32

-100

-97

-95.2

-94

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-32A-43A

1

-100

-97

-95.2

FDD

32

-100

-97

-95.2

-94

FDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_1A-32A-42A-43A

1

-100

-97

-95.2

FDD

32

-100

-97

-95.2

-94

42

-98.5

-95.5

-93.7

-92.5

TDD

43

-98.5

-95.5

-93.7

-92.5

CA_2A-4A-5A-29A

2

-97.7

-94.7

-92.9

-91.7

FDD

4

-99.7

-96.7

-94.9

-93.7

5

-98

-95

29

-97

-94

CA_2A-4A-29A

2

-97.7

-94.7

-92.9

-91.7

FDD

4

-99.7

-96.7

-94.9

-93.7

29

-97

-94

CA_2A-4A-29A-30A

2

-97.6

-94.6

-92.8

-91.6

FDD

4

-99.6

-96.6

-94.8

-93.6

29

-97

-94

30

-98.5

-95.5

CA_2A-5A-29A

2

-98

-95

-93.2

-92

FDD

5

-98

-95

29

-97

-94

CA_2A-7A-29A-66A

CA_2A-7C-29A-66A

CA_2A-7A-7A-29A-66A

2

-97.7

-94.7

-92.9

-91.7

FDD

7

-94.5

-92.7

-91.5

29

-97

-94

66

-99

-96

-94.2

-93

CA_2A-29A

2

-98

-95

-93.2

-92

FDD

29

-98.7

-97

-94

CA_2A-2A-29A

2

-98

-95

-93.2

-92

FDD

29

-97

-94

CA_2C-29A

2

-98

-95

-93.2

-92

FDD

29

-97

-94

CA_2A-29A-30A

2

-97.6

-94.6

-92.8

-91.6

FDD

29

-97

-94

30

-98.5

-95.5

CA_2A-2A-29A-30A

2

-97.6

-94.6

-92.8

-91.6

FDD

29

-97

-94

30

-98.5

-95.5

CA_2C-29A-30A

2

-97.6

-94.6

-92.8

-91.6

FDD

29

-97

-94

30

-98.5

-95.5

CA_2A-29A-30A-66A

2

-97.6

-94.6

-92.8

-91.6

FDD

29

-97

-94

30

-98.5

-95.5

66

-99.1

-96.1

-94.3

-93.1

CA_2A-29A-66A

2

-97.7

-94.7

-92.9

-91.7

FDD

29

-97

-94

66

-99.2

-96.2

-94.4

-93.2

CA_4A-4A-29A

4

-100

-97

-95.2

-94

FDD

29

-97

-94

CA_3A-7A-20A-32A

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

20

-97

-94

-91.2

-90

32

-99.5

-96.5

-94.7

-93.5

CA_3A-7A-32A

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

32

-100

-97

-95.2

-94

CA_3A-20A-32A-42A

3

-96.8

-93.8

-92

FDD

20

-97

32

-99.5

-96.5

-94.7

-93.5

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_3A-20A-32A-43A

3

-97

-94

-92.2

FDD

20

-97

32

-99.5

-96.5

-94.7

-93.5

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_3A-32A

3

-97

-94

-92.2

-91

FDD

32

-99.5

-96.5

-94.7

-93.5

CA_3C-32A

35

-97

-94

-92.2

-91

FDD

32

-99.5

-96.5

-94.7

-93.5

CA_3A-32A-42A

3

-96.8

-93.8

-92

FDD

32

-99.5

-96.5

-94.7

-93.5

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_3A-32A-43A

3

-97

-94

-92.2

FDD

32

-99.5

-96.5

-94.7

-93.5

FDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_3A-32A-42A-43A

3

-96.8

-93.8

-92

FDD

32

-99.5

-96.5

-94.7

-93.5

42

-98.5

-95.5

-93.7

-92.5

TDD

43

-98.5

-95.5

-93.7

-92.5

CA_3A-69A

3

-97

-94

-92.2

-91

FDD

69

-100

-97

-95.2

-94

CA_4A-4A-29A-30A

4

-99.6

-96.6

-94.8

-93.6

FDD

29

-97

-94

30

-98.5

-95.5

CA_4A-5A-29A

4

-100

-97

-95.2

-94

FDD

5

-98

-95

29

-97

-94

CA_4A-29A

4

-100

-97

-95.2

-94

FDD

29

-98.7

-97

-94

CA_4A-29A-30A

4

-99.6

-96.6

-94.8

-93.6

FDD

29

-97

-94

30

-98.5

-95.5

CA_5A-29A

5

-98

-95

FDD

29

-97

-94

CA_7A-20A-32A

7

-98

-95

-93.2

-92

FDD

20

-97

-94

-91.2

-90

32

-100

-97

-95.2

-94

CA_7A-29A

CA_7A-7A-29A

CA_7C-29A

7

-98

-95

-93.2

-92

FDD

29

-97

-94

CA_7A-29A-66A

7

-98

-95

-93.2

-92

FDD

29

-97

-94

66

-99.5

-96.5

-94.7

-93.5

CA_7A-7A-29A-66A

7

-98

-95

-93.2

-92

FDD

29

-97

-94

66

-99.5

-96.5

-94.7

-93.5

CA_7C-29A-66A

7

-98

-95

-93.2

-92

FDD

29

-97

-94

66

-99.5

-96.5

-94.7

-93.5

CA_7A-32A

7

-95

-93.2

-92

FDD

32

-100

-97

-95.2

-94

CA_20A-32A

20

-97

-94

-91.2

-90

FDD

32

-100

-97

-95.2

-94

CA_20A-32A-42A

20

-97

FDD

32

-100

-97

-95.2

-94

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_20A-32A-43A

20

-97

FDD

32

-100

-97

-95.2

-94

FDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_20A-75A

20

-97

-94

-91.2

-90

FDD

75

-100

-97

-95.2

-94

CA_20A-76A

20

-97

-94

-91.2

-90

FDD

76

-100

CA_20A-67A

20

-97

-94

-91.2

-90

FDD

67

-100

-97

-95.2

-94

CA_23A-29A

23

-100

-97

-95.2

-94

FDD

29

-98.7

-97

-94

CA_29A-30A

29

-97

-94

FDD

30

-99

-96

CA_29A-30A-66A
CA_29A-30A-66A-66A

29

-97

-94

FDD

30

-98.5

-95.5

66

-99.1

-96.1

-94.3

-93.1

CA_29A-66A

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

CA_29A-66C

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

CA_29A-66A-66A

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

CA_29A-66A-70A

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

CA_29A-66A-70C

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

-94

CA_29A-66C-70A

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

CA_29A-66A-66A-70A

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

CA_29A-66C-70C

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

-94

CA_29A-66A-66A-70C

29

-97

-94

FDD

66

-99.5

-96.5

-94.7

-93.5

70

-100

-97

-95.2

-94

CA_29A-70A

29

-97

-94

FDD

70

-100

-97

-95.2

-94

CA_29A-70C

29

-97

-94

FDD

70

-100

-97

-95.2

-94

CA_32A-42A

32

-100

-97

-95.2

-94

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

CA_32A-43A

32

-100

-97

-95.2

-94

FDD

43

-98.5

-95.5

-93.7

-92.5

TDD

CA_32A-42A-43A

32

-100

-97

-95.2

-94

FDD

42

-98.5

-95.5

-93.7

-92.5

TDD

43

-98.5

-95.5

-93.7

-92.5

TDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port.

NOTE 4: Void

NOTE 5: Applicable only if operation with 4 antenna ports is supported in the band with carrier aggregation configured.

NOTE 6: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is < 60 MHz. For each channel bandwidth in Band 3, the requirement applies regardless of channel bandwidth in Band 1.

NOTE 7: These requirements apply when the uplink is active in Band 1 and the separation between the lower edge of the uplink channel in Band 1 and the upper edge of the downlink channel in Band 3 is ≥ 60 MHz. For each channel bandwidth in Band 3, the requirement applies regardless of channel bandwidth in Band 1.

Table 7.3A.0-0e: Void

For band combinations including operating band 46 (Table 5.2-1), the requirements are specified in Table 7.3A.0-0eA for the uplink in any band other than band 46 with the uplink configuration specified in Table 7.3.3-2 and Table 7.3A.0-0eC.

For band combinations including operating band 49 (Table 5.5-1), the requirements are specified in Table 7.3A.0-0eA for the uplink in any band other than Band 49 with uplink configurations specified in Table 7.3.3-2 and measurement exclusion region in Table 7.3A.0-0eD.

Table 7.3A.0-0eA: Reference sensitivity QPSK PREFSENS (CA with band 46 or Band 49)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz

(dBm)

3 MHz

(dBm)

5 MHz

(dBm)

10 MHz

(dBm)

15 MHz

(dBm)

20 MHz

(dBm)

Duplex mode

CA_1A-3A-46A

CA_1A-3A-46C

CA_1A-3A-46D

CA_1A-3A-46E

1

-100

-97

-95.2

-94

FDD

3

-97

-94

-92.2

-91

46

-93

-90

TDD

CA_1A-5A-7A-46A

CA_1A-5A-7A-46C

1

-100

-97

-95.2

-94

FDD

5

-98

-95

7

-95

-93.2

-92

46

-90

TDD

CA_1A-5A-46A

CA_1A-5A-46C

CA_1A-5A-46D

1

-100

-97

-95.2

-94

FDD

5

-98

-95

FDD

46

-90

TDD

CA_2A-5A-46A

2

-98

-95

-93.2

-92

FDD

5

-98

-95

46

-90

CA_2A-5A-46A-66A

CA_2A-5A-46C-66A

CA_2A-5A-46D-66A

CA_2A-5A-46E-66A

CA_2A-5A-46A-66A-66A

CA_2A-5A-46C-66A-66A

CA_2A-5A-46D-66A-66A

2

-98

-95

-93.2

-92

FDD

5

-98

-95

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-7A-46A-66A

2

-98

-95

-93.2

-92

FDD

7

-98

-95

-93.2

-92

46

-93

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-13A-46A

2

-98

-95

-93.2

-92

FDD

13

-97

-94

46

-90

TDD

CA_1A-7A-46A

CA_1A-7A-46C

CA_1A-7A-46D

CA_1A-7A-46E

1

-100

-97

-95.2

-94

FDD

7

-98

-95

-93.2

-92

FDD

46

-90

TDD

CA_1A-46A

CA_1A-46C

CA_1A-46D

CA_1A-46E

1

-100

-97

-95.2

-94

FDD

46

-93

-90

TDD

CA_2A-5A-46C

CA_2A-5A-46D

CA_2A-5A-46E

2

-98

-95

-93.2

-92

FDD

5

-98

-95

FDD

46

-90

TDD

CA_2A-7A-46A

CA_2A-7A-7A-46A

CA_2A-7A-46C

CA_2A-7A-7A-46C

CA_2A-7A-46D

CA_2A-7A-7A-46D

CA_2A-7A-46E

CA_2A-7A-7A-46E

2

-98

-95

-93.2

-92

FDD

7

-98

-95

-93.2

-92

46

-93

-90

TDD

CA_2A-13A-46C

2

-98

-95

-93.2

-92

FDD

13

-97

-94

FDD

46

-90

TDD

CA_2A-13A-46A-66A

CA_2A-13A-46C-66A

CA_2A-13A-46D-66A

CA_2A-13A-46A-66A-66A

CA_2A-13A-46C-66A-66A

CA_2A-13A-46D-66A-66A

2

-98

-95

-93.2

-92

FDD

13

-97

-94

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-46A

CA_2A-46E

CA_2A-2A-46A

CA_2A-2A-46D

CA_2A-46C

CA_2A-46A-46A

CA_2A-2A-46C

CA_2A-46A-46C

CA_2A-46D

CA_2A-46A-46D

2

-98

-95

-93.2

-92

FDD

46

-90

TDD

CA_2A-46A-48A10,11

CA_2A-46A-48C10,11

CA_2A-46A-48D10,11

CA_2A-46A-48E10,11

CA_2A-46C-48A10,11

CA_2A-46C-48C10,11

CA_2A-46C-48D10,11

CA_2A-46C-48E10,11

CA_2A-46D-48A10,11

CA_2A-46D-48C10,11

CA_2A-46E-48A10,11

CA_2A-46E-48C10,11

2

-97.8

-94.8

-93.0

-91.7

FDD

46

-83

TDD

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-46A-48A12

CA_2A-46A-48C12

CA_2A-46A-48D12

CA_2A-46A-48E12

CA_2A-46C-48A12

CA_2A-46C-48C12

CA_2A-46C-48D12

CA_2A-46C-48E12

CA_2A-46D-48A12

CA_2A-46E-48A12

CA_2A-46D-48C12

CA_2A-46E-48C12

2

-97.8

-94.8

-93.0

-91.7

FDD

46

-83

TDD

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-46A-48A-66A10,11

CA_2A-46A-48C-66A10,11

CA_2A-46A-48D-66A10,11

CA_2A-46C-48A-66A10,11

CA_2A-46C-48C-66A10,11

CA_2A-46C-48D-66A10,11

CA_2A-46D-48A-66A10,11

CA_2A-46D-48C-66A10,11

CA_2A-46E-48A-66A10,11

2

-97.7

-94.7

-92.9

-91.7

FDD

46

-83

TDD

48

-71.7

-71.7

-71.7

-71.7

TDD

66

-99.3

-96.3

-94.5

-93.3

FDD

CA_2A-46A-48A-66A12

CA_2A-46A-48D-66A12

CA_2A-46C-48C-66A12

CA_2A-46C-48D-66A12

CA_2A-46D-48A-66A 12

CA_2A-46D-48C-66A12

CA_2A-46E-48A-66A12

2

-97.7

-94.7

-92.9

-91.7

FDD

46

-83

TDD

48

-97.1

-94.7

-93.2

-92.5

TDD

66

-99.3

-96.3

-94.5

-93.3

FDD

CA_2A-46A-48C-66A12

CA_2A-46C-48A-66A12

2

-97.7

-94.7

-92.9

-91.7

FDD

46

-83

TDD

48

-71.7

-71.7

-71.7

-71.7

TDD

66

-99.3

-96.3

-94.5

-93.3

FDD

CA_2A-46A-66A

2

-98

-95

-93.2

-92

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-46A-46A-66A

CA_2A-46C-66A

2

-98

-95

-93.2

-92

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-46A-46C-66A

CA_2A-46D-66A

CA_2A-46E-66A

CA_2A-46A-66A-66A

CA_2A-46C-66A-66A

CA_2A-46D-66A-66A

CA_2A-46E-66A-66A

2

-98

-95

-93.2

-92

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_2A-49A9

2

-97.8

-94.8

-93.0

-91.7

FDD

49

-95.5

-92.5

TDD

CA_3A-7A-46C

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

46

-90

TDD

CA_3A-7A-46D

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

46

-90

TDD

CA_3A-7A-46E

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

46

-90

TDD

CA_3A-46A

CA_3A-46C

CA_3A-46D

CA_3A-46E

3

-98.7

-97

-94

-92.2

-91

FDD

46

-93

-90

TDD

CA_3C-46A

3

-97

-94

-92.2

-91

FDD

46

-90

TDD

CA_3A-3A-46A

CA_3C-46C

CA_3C-46D

CA_3A-3A-46C

3

-97

-94

-92.2

-91

FDD

46

-90

TDD

CA_3A-7A-46A

CA_3A-7C-46A

CA_3A-7C-46C

CA_3A-7C-46D

CA_3A-7C-46E

3

-97

-94

-92.2

-91

FDD

7

-98

-95

-93.2

-92

46

-90

TDD

CA_3A-32A-46A

CA_3A-32A-46C

CA_3A-32A-46D

CA_3A-32A-46E

3

-97

-94

-92.2

-91

FDD

32

-100

-97

-95.2

-94

SDL

46

-90

TDD

CA_3A-7A-32A-46A CA_3A-7A-32A-46C CA_3A-7A-32A-46D CA_3A-7A-32A-46E

3

-97

-94

-92.2

-91

FDD

7

-95

-93.2

-92

FDD

32

-100

-97

-95.2

-94

FDD

46

-90

TDD

CA_4A-46A

CA_4A-46C

CA_4A-46A-46A

CA_4A-46A-46C

CA_4A-46D

CA_4A-46A-46D

4

-100

-97

-95.2

-94

FDD

46

-90

TDD

CA_5A-7A-46A

CA_5A-7A-46C

CA_5A-7A-46D

5

-98

-95

FDD

7

-95

-93.2

-92

FDD

46

-90

TDD

46

-90

TDD

CA_5A-12A-46A, CA_5A-12A-46C, CA_5A-12A-46D

5

-98

-95

FDD

12

-97

-94

46

-90

TDD

CA_5A-46A

CA_5A-46C

CA_5A-46D

CA_5A-46E

CA_5B-46A

CA_5B-46C

CA_5B-46D

CA_5B-46E

5

-98

-95

FDD

46

-93

-90

TDD

CA_5A-46A-66A

5

-98

-95

FDD

46

-90

66

-99.5

-96.5

-94.7

-93.5

CA_5A-46C-66A

5

-98

-95

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_5A-46D-66A

CA_5A-46E-66A

CA_5A-46A-66A-66A

CA_5A-46C-66A-66A

CA_5A-46D-66A-66A

CA_5A-46E-66A-66A

5

-98

-95

FDD

46

-90

66

-99.5

-96.5

-94.7

-93.5

CA_7A-46A

CA_7A-46C

CA_7A-7A-46C

CA_7A-46D

CA_7A-46E

CA_7C-46A

CA_7C-46C

CA_7C-46D

CA_7C-46E

7

-98

-95

-93.2

-92

FDD

46

-93

-90

TDD

CA_7A-7A-46A

CA_7A-7A-46D

CA_7A-7A-46E

7

-98

-95

-93.2

-92

FDD

46

-90

TDD

CA_7A-32A-46A

CA_7A-32A-46C

CA_7A-32A-46D

CA_7A-32A-46E

7

-95

-93.2

-92

FDD

32

-100

-97

-95.2

-94

SDL

46

-90

TDD

CA_7A-46A-66A

7

-97.5

-94.5

-92.7

-91.5

FDD

46

-93

-90

TDD

66

-99

-96

-94.2

-93

FDD

CA_8A-46A

CA_8A-46D

CA_8A-46E

CA_8B-46C

CA_8B-46D

8

-102.2

-99.2

-97

-94

FDD

46

-90

TDD

CA_8A-46C

8

-102.2

-99.2

-97

-94

FDD

46

-90

TDD

CA_8B-46A

8

-102.2

-99.2

-97

-94

FDD

46

-90

TDD

CA_11A-46A

11

-100

-97

FDD

46

-90

TDD

CA_11A-46C

11

-100

-97

FDD

46

-90

TDD

CA_11A-46D

11

-100

-97

-95.2

FDD

46

-90

TDD

CA_11A-46E

11

-100

-97

FDD

46

-90

TDD

CA_12A-46A

CA_12A-46C

CA_12A-46D

12

-97

-94

FDD

46

-90

TDD

CA_12A-46E

12

-97

-94

FDD

46

-90

TDD

CA_13A-46A

CA_13A-46C

CA_13A-46D

CA_13A-46E

13

-97

-94

FDD

46

-90

TDD

CA_13A-46A-66A

CA_13A-46C-66A

CA_13A-46D-66A

CA_13A-46A-66A-66A

CA_13A-46C-66A-66A

CA_13A-46D-66A-66A

CA_13A-46E-66A

13

-97

-94

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_19A-46A

CA_19A-46C

CA_19A-46D

CA_19A-46E

19

-100

-97

-95.2

FDD

46

-90

TDD

CA_21A-46A

CA_21A-46C

CA_21A-46D

CA_21A-46E

21

-100

-97

-95.2

FDD

46

-90

TDD

CA_25A-46A

CA_25A-46C

CA_25A-46D

25

-101.2

-98.2

-96.5

-93.5

-91.7

-90.5

FDD

46

-93

-90

TDD

CA_26A-46A

26

-99.7

-97.57

-94.57

FDD

46

-90

TDD

CA_28A-46A

CA_28A-46C

CA_28A-46D

CA_28A-46E

28

-98.5

-95.5

-93.7

-91

FDD

46

-93

-90

TDD

CA_29A-46A-66A

29

-97

-94

FDD

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_39A-46A

39

-100

-97

-95.2

-94

TDD

46

-90

TDD

CA_39A-46C

39

-100

-97

-95.2

-94

TDD

46

-90

TDD

CA_39C-46A

39

-100

-97

-95.2

-94

TDD

46

-90

TDD

CA_39A-46E

CA_39C-46C

CA_39C-46D

39

-100

-97

-95.2

-94

TDD

46

-90

CA_40A-46A

CA_40A-46D

CA_40A-46E

CA_40C-46C

CA_40C-46D

CA_40D-46A

CA_40D-46C

40

-100

-97

-95.2

-94

TDD

46

-93

-90

TDD

CA_40A-46C

40

-100

-97

-95.2

-94

TDD

46

-90

TDD

CA_40C-46A

40

-100

-97

-95.2

-94

TDD

46

-90

TDD

CA_41A-46A

CA_41A-46C

CA_41A-46D

CA_41A-46E

CA_41C-46A

CA_41C-46C

CA_41C-46D

CA_41D-46A

CA_41D-46C

41

-98

-95

-93.2

-92

TDD

46

-90

TDD

CA_42A-46A

42

-99

-96

-94.2

-93

TDD

46

-83

TDD

CA_46A-48A

CA_46A-48A-48A

CA_46A-48C

CA_46A-48D

CA_46A-48E

CA_46C-48A

CA_46C-48A-48A

CA_46C-48C

CA_46C-48D

CA_46C-48E

CA_46D-48A

CA_46D-48C

CA_46D-48A-48A

CA_46E-48A

CA_46E-48C

46

-83

TDD

48

-99

-96

-94.2

-93

TDD

CA_46A-48A-66A10,11

CA_46A-48C-66A10,11

CA_46A-48D-66A10,11

CA_46A-48E-66A10,11

CA_46C-48A-66A10,11

CA_46C-48C-66A10,11

CA_46C-48D-66A10, 11

CA_46C-48E-66A10,11

CA_46D-48A-66A10,11

CA_46D-48C-66A 10,11

CA_46E-48A-66A10,11

CA_46E-48C-66A10,11

46

-83

FDD

48

-71.7

-71.7

-71.7

-71.7

TDD

66

-99.3

-96.3

-94.5

-93.2

FDD

CA_46A-48A-66A12

CA_46A-48C-66A12

CA_46A-48D-66A12

CA_46A-48E-66A12

CA_46C-48A-66A12

CA_46C-48C-66A12

CA_46C-48D-66A12

CA_46C-48E-66A12

CA_46D-48A-66A12

CA_46D-48C-66A 12

CA_46E-48A-66A12

CA_46E-48C-66A12

46

-83

FDD

48

-97.1

-94.7

-93.2

-92.5

TDD

66

-99.3

-96.3

-94.5

-93.2

FDD

CA_46A-48A-71A

CA_46A-48A-48A-71A

CA_46A-48C-71A

CA_46C-48A-71A

CA_46C-48C-71A

CA_46C-48A-48A-71A

46

-83

TDD

48

-99

-96

-94.2

-93

TDD

71

-97.2

-94.2

-92.0

-87.5

FDD

CA_46A-66A CA_46A-46A-66A

CA_46A-66A-66A

CA_46A-66C

CA_46A-46C-66A

CA_46A-46D-66A

CA_46C-66A

CA_46C-66A-66A

CA_46D-66A

CA_46D-66A-66A

CA_46E-66A

CA_46E-66A-66A

46

-90

TDD

66

-99.5

-96.5

-94.7

-93.5

FDD

CA_46A-70A

46

-90

TDD

70

 

 

-100

-97

-95.2

FDD

CA_46A-71A
CA_46C-71A
CA_46D-71A

46

-90

FDD

71

-97.2

-94.2

-92.0

-87.5

TDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD/FS3 as described in Annex A.5.1.1/A.5.2.1/A.5.4.1.

NOTE 3: The signal power is specified per port.

NOTE 4: Void

NOTE 5: The requirement for B46 does not apply when there is at least one individual RE within the B46 downlink transmission bandwidth which falls into the reference sensitivity exclusion region as specified in Table 7.3A.0-0eC.

NOTE 6: Void

NOTE 7: 7 indicates that the requirement is modified by -0.5 dB when the carrier frequency of the assigned E-UTRA channel bandwidth is within 865-894 MHz.

NOTE 8: When Band 46 have self interference problems by dual uplink CA, then the requirements not apply in exclusion zone which is frequency range within (harmonics frequency region + FHD) and IMD frequency region as follow.

NOTE 9: The requirement for B49 does not apply when there is at least one individual RE within the B49 downlink transmission bandwidth which falls into the reference sensitivity exclusion region as specified in Table 7.3A.0-0eD.

NOTE 10: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band which excludes band 46 and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_2-46-48, CA_46-48-66, and CA_2-46-48-66. For harmonic issue not related with band 46, the uplink configuration of CA_2-48, CA_48-66 and CA_2-48-66 in Table 7.3A.0-0b can be used.

NOTE 11: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 12: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_1A-3A-46A

CA_1A-3A

2*fc_1A + fc_3A

2*BW_1A + BW_3A

CA_1A-3A-46A

CA_1A-3A

fc_1A – 2*fc_3A

BW_1A + 2*BW_3A

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_1A-5A-46A

CA_1A-5A

2*fc_1A + 2*fc_5A

2*BW_1A + 2*BW_5A

CA_1A-7A-46A

CA_1A-7A

3*fc_7A – fc_1A

3*BW_7A + BW_1A

CA_5A-7A-46A

CA_5A-7A

2*fc_7A + fc_5A

2*BW_7A + BW_5A

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_2A-5A-46D

CA_2A-5A

3*fc_5A + 1*fc_2A

3*BW_5A + 1*BW_2A

CA_2A-5A-46D

CA_2A-5A

2*fc_5A – 3*fc_2A

2*BW_5A + 3*BW_2A

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_5A-46D-66A

CA_5A-66A

3*fc_66A + 1*fc_5A

3*BW_66A + 1*BW_5A

CA_5A-46D-66A

CA_5A-66A

2*fc_66A – 3*fc_5A

2*BW_66A + 3*BW_5A

CA_5A-46D-66A

CA_5A-66A

2*fc_66A + 3*fc_5A

2*BW_66A + 3*BW_5A

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_13A-46D-66A

CA_13A-66A

2*fc_66A + 2*fc_13A

2*BW_66A + 2*BW_13A

CA_13A-46D-66A

CA_13A-66A

2*fc_66A + 3*fc_13A

2*BW_66A + 3*BW_13A

IMD frequency range

DL_CA configuration

UL_CA configuration

Exclusion zone center frequency

Exclusion zone BW

CA_2A-13A-46D

CA_2A-13A

3*fc_13A + 1*fc_2A

3*BW_13A + 1*BW_2A

Table 7.3A.0-0eB: Void

Table 7.3A.0-0eC specifies the Band 46 reference measurement exclusion region for different licensed component carriers and channel bandwidth. The exclusion region is defined according to the licensed component carrier channel bandwidth. The UL configurations to be adopted for the test are specified in Table 7.3.3-2. The exclusion region in Table 7.3A.0-0eC is specified for the case of 10MHz and 20MHz channel bandwidth in Band 46..

Table 7.3A.0-0eC: Band 46 Reference sensitivity measurement exclusion region in MHz

Licensed Component Carriers / E-UTRA Band / Harmonic order / Channel BW in UL

Licensed Component Carriers

Harmonic order

5MHz

10MHz

15MHz

20MHz

1

3

+/- 15

+/- 23

+/- 35

+/- 45

2

3

+/- 15

+/- 23

+/- 35

+/- 45

3

3

+/- 15

+/- 23

+/- 35

+/- 45

4

3

+/- 15

+/- 23

+/- 35

+/- 45

5

7

+/- 10

+/- 20

71

2

+/- 15

+/- 25

+/- 38

+/- 50

8

6

+/- 10

+/- 20

11

4

+/- 15

+/- 25

12

8

+/- 10

+/- 20

13

7

+/- 10

+/- 20

19

7

+/- 10

+/- 20

+/- 30

21

4

+/- 15

+/- 25

+/- 38

25

3

+/- 15

+/- 23

+/- 35

+/- 45

26

7

+/- 10

+/- 20

+/- 30

28

7

+/- 10

+/- 20

+/- 30

+/- 40

28

8

+/- 10

+/- 20

+/- 30

+/- 40

39

3

+/- 15

+/- 23

+/- 35

+/- 45

41

2

+/- 15

+/- 25

+/- 38

+/- 50

66

3

+/- 15

+/- 23

+/- 35

+/- 45

NOTE 1: Even though UL harmonic does not fall directly into Band 46 the exclusion region still applies.

NOTE 2: The center of the exclusion region is obtained by multiplying the UL channel center frequency by the harmonic order.

Table 7.3A.0-0eD specifies the Band 49 reference measurement exclusion region for different licensed component carriers and channel bandwidth. The exclusion region is defined according to the licensed component carrier channel bandwidth. The UL configurations to be adopted for the test are specified in Table 7.3.3-2.

Table 7.3A.0-0eD: Band 49 reference sensitivity measurement exclusion region in MHz.

Licensed Component Carriers / E-UTRA Band / Harmonic order / Channel BW in UL

Licensed Component Carriers

Harmonic order

5MHz

10MHz

15MHz

20MHz

21

2

+/- 12.5

+/- 25

+/- 37.5

+/- 50

NOTE 1: Even though UL harmonic does not fall directly into Band 49 the exclusion region still applies.

NOTE 2: The center of the exclusion region is obtained by multiplying the UL channel center frequency by the harmonic order.

In all cases for single uplink inter-band CA, unless given by Table 7.3.3-3 for the band with the active uplink carrier, the applicable reference sensitivity requirements shall be verified with the network signalling value NS_01 (Table 6.2.4.3-1) configured.

For inter-band carrier aggregation with one component carrier per operating band (up to four downlinks) and the uplink assigned to two E-UTRA bands the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.3.3-1, Table 7.3.3-1a and Table 7.3.3-2. The reference sensitivity is defined to be met with all downlink component carriers active and both of the uplink carriers active.

For E-UTRA CA configurations with uplink and downlink assigned to two E-UTRA bands given in Table 7.3A.0-0f the reference sensitivity is defined only for the specific uplink and downlink test points which are specified in Table 7.3A.0-0f. For E-UTRA CA configurations with uplink assigned to two E-UTRA bands and downlink assigned to three E-UTRA bands given in Table 7.3.1A-0g the reference sensitivity is defined only for the specific uplink and downlink test points which are specified in Table 7.3.1A-0g. For these test points the reference sensitivity requirement specified in Table 7.3.3-1 and Table 7.3.3-1a are relaxed by the amount of the corresponding parameter MSD given in Table 7.3A.0-0f and Table 7.3A.0-0g.

The allowed exceptions defined in Table 7.3A.0-0a and Table 7.3A.0-0b for inter-band carrier aggregation with a single active uplink are also applicable for dual uplink operation.

Table 7.3A.0-0f: 2DL/2UL interband Reference sensitivity QPSK PREFSENS and uplink/downlink configurations

E-UTRA Band / Channel bandwidth / NRB / Duplex mode

Source of IMD

EUTRA CA

Configuration

EUTRA band

UL Fc
(MHz)

UL/DL BW
(MHz)

UL
CLRB

DL Fc (MHz)

MSD
(dB)

Duplex mode

CA_1A-3A

1

1950

5

25

2140

23

FDD

IMD3

3

1760

5

25

1855

N/A

N/A

CA_1A-8A

1

1965

5

25

2155

6

FDD

IMD4

8

887.5

5

25

932.5

N/A

N/A

CA_2A-4A

2

1860

20

502

1940

5

FDD

IMD3

4

1752.5

5

25

2152.5

N/A

N/A

CA_2A-4A

2

1868.3

5

25

1948.3

N/A

FDD

N/A

4

1735

5

25

2135

5

IMD5

CA_2A-46A

2

1880

5

25

1960

12.0

FDD

IMD34

46

5720

20

100

5720

N/A

N/A

CA_2A-48A

2

1852.5

5

25

1932.5

[12]

FDD

IMD4

48

3625

20

100

3625

N/A

TDD

N/A

CA_2A-49A

2

1852.5

5

25

1932.5

[12]

FDD

IMD4

49

3625

20

100

3625

N/A

TDD

N/A

CA_2A-66A

2

1855

5

25

1935

20

FDD

IMD3

66

1775

5

25

2175

N/A

N/A

CA_2A-66A

2

1883.3

5

25

1963.3

N/A

FDD

N/A

66

1750

5

25

2150

4

IMD5

CA_3A-5A

3

1771

10

50

1866

4

FDD

IMD4

5

838

5

25

883

N/A

N/A

CA_3A-5A

3

1721

10

50

1816

N/A

FDD

N/A

5

838

5

25

883

24

IMD24

CA_3A-7A

3

1730

5

25

1825

N/A

FDD

N/A

7

2535

10

50

2655

13

IMD4

CA_3A-8A

3

1755

10

50

1850

N/A

FDD

N/A

8

900

5

25

945

8

IMD44

CA_3A-8A

3

1747.5

10

50

1842.5

6.4

FDD

IMD5

8

897.5

5

25

942.5

N/A

N/A

CA_3A-18A

3

1721

5

25

1816

4

FDD

IMD4

18

823

5

25

868

N/A

N/A

CA_3A-19A

3

1771

5

25

1866

4

FDD

IMD4

19

838

5

25

883

N/A

N/A

CA_3A-19A

3

1721

5

25

1816

N/A

FDD

N/A

19

838

5

25

883

27

IMD24

CA_3A-20A

3

1775

5

25

1870

4

FDD

IMD4

20

840

5

25

799

N/A

N/A

CA_3A-20A

3

1735

5

25

1830

N/A

FDD

N/A

20

847

5

25

806

9

IMD4

CA_3A-26A

3

1771

5

25

1866

4

FDD

IMD4

26

838

5

25

883

N/A

N/A

CA_3A-26A

3

1721

5

25

1816

N/A

FDD

N/A

26

838

5

25

883

26

IMD24

CA_3A-41A

3

1740

5

25

1835

8.2

FDD

IMD4

41

2657.5

5

25

2657.5

N/A

TDD

N/A

CA_3A-42A

3

1740

5

25

1835

29.8

FDD

IMD24

42

3575

5

25

3575

N/A

TDD

N/A

CA_3A-42A

3

1765

5

25

1860

8.0

FDD

IMD44

42

3435

5

25

3435

N/A

TDD

N/A

CA_4A-5A

4

1721

5

25

2121

N/A

FDD

N/A

5

838

5

25

883

26

IMD24

CA_4A-7A

4

1730

5

25

2130

N/A

FDD

N/A

7

2535

5

25

2655

15

IMD4

CA_5A-7A

5

834

5

25

879

12

FDD

IMD34

7

2547

10

50

2667

N/A

N/A

CA_5A-66A

5

838

5

25

883

30

FDD

IMD24

66

1721

5

25

2121

N/A

N/A

CA_7A-20A

7

2512

10

50

2632

N/A

FDD

N/A

20

851

5

25

810

12

IMD34

CA_7A-26A

7

2556

5

25

2676

N/A

FDD-FDD

N/A

26

837

5

25

882

16.0

IMD3

7

2567.5

5

25

2687.5

2.5

FDD-FDD

IMD5

26

816.5

5

25

861.5

N/A

N/A

CA_8A-41A

8

882.5

5

25

927.5

12.1

FDD

IMD34

41

2685

10

50

2685

N/A

TDD

N/A

CA_19A-42A3

19

N/A

N/A

N/A

N/A

N/A

FDD

N/A

42

N/A

N/A

N/A

N/A

N/A

TDD

N/A

CA_21A-28A

21

1450.4

5

25

1498.4

[2.5]

FDD

IMD5

28

735.5

5

25

790.5

N/A

TDD

N/A

CA_21A-42A3

21

N/A

N/A

N/A

N/A

N/A

FDD

N/A

42

N/A

N/A

N/A

N/A

N/A

TDD

N/A

CA_28A-42A

28

705.5

5

25

760.5

[5.5]

FDD

IMD5

42

3582.5

5

25

3582.5

N/A

TDD

N/A

CA_40A-42A

40

2350

5

25

2350

N/A

TDD

N/A

42

3500

5

25

3550

5

IMD4

40

2350

5

25

2350

5

TDD

IMD4

42

3525

5

25

3525

N/A

N/A

NOTE 1: Both of the transmitters shall be set min(+20 dBm, PCMAX_L,c) as defined in subclause 6.2.5A

NOTE 2: RBSTART = 0

NOTE 3: No requirements apply when there is at least one individual RE within the intermodulation generated by the dual uplink is within the downlink transmission bandwidth of the FDD band. The reference sensitivity should only be verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 4: This band is subject to IMD5 also which MSD is not specified.

NOTE 5: Void

NOTE 6: For operations with 4 antenna ports, the MSD in the applicable bands shall be modified by the absolute value of ΔRIB,4R in Table 7.3.3-1a when MSD > 0.

Table 7.3A.0-0g: 3DL/2UL interband Reference sensitivity QPSK PREFSENS and uplink/downlink configurations

E-UTRA Band / Channel bandwidth / NRB / Duplex mode

Source of IMD

EUTRA CA

EUTRA CA

EUTRA band

UL Fc

UL BW

UL

DL Fc

DL BW

MSD

Duplex mode

DL Configuration

UL Configuration

(MHz)

(MHz)

CLRB

(MHz)

(MHz)

(dB)

CA_1A-3A-28A

CA_1A-28A

1

1975

5

25

2165

5

N/A

FDD

N/A

28

710.5

5

25

765.5

5

N/A

N/A

3

1723.5

5

25

1818.5

5

4.0

IMD5

CA_3A-28A

3

1780

5

25

1875

5

N/A

FDD

N/A

28

710.5

5

25

765.5

5

N/A

N/A

1

1949

5

25

2139

5

11.0

IMD4

CA_1A-3A-40A

CA_1A-3A

1

1950

5

25

 2140

5

N/A

FDD

N/A

3

1735

5

25

1830

5

N/A

FDD

N/A

40

2380

5

25

2380

5

8.0

TDD

IMD5

CA_1A-3A-41A

CA_1A-3A

1

1977.5

5

25

2167.5

5

N/A

FDD

N/A

3

1712.5

5

25

1807.5

5

N/A

FDD

N/A

41

2507.5

5

25

2507.5

5

5.0

TDD

IMD5

CA_1A-3A-42A

CA_1A-3A

1

1922.5

5

25

2112.5

5

N/A

FDD

N/A

3

1782.5

5

25

1877.5

5

N/A

FDD

N/A

42

3425

5

13.0

TDD

IMD4

CA_1A-5A-7A

CA_1A-7A

1

1968

5

25

2158

5

N/A

FDD

N/A

7

2512

10

50

2632

10

N/A

N/A

5

835

5

25

880

5

1.0

IMD5

CA_1A-5A-40A

CA_1A-5A

1

1977.5

5

25

2167.5

5

N/A

FDD

N/A

5

826.5

5

25

871.5

5

N/A

FDD

N/A

40

2305

10

50

2305

10

9.0

TDD

IMD4

CA_1A-7A-26A

CA_1A-7A

1

1965

5

25

2155

5

N/A

FDD

N/A

7

2510

10

50

2630

10

N/A

N/A

26

830

5

50

875

5

3.5

IMD5

CA_1A-7A-28A

CA_1A-7A

1

1935

5

25

2125

5

N/A

FDD

N/A

7

2510

10

50

2630

10

N/A

N/A

28

730

10

50

785

10

4.5

IMD5

CA_1A-28A

1

1935

5

25

2125

5

N/A

FDD

N/A

28

730

10

50

785

10

N/A

N/A

7

2545

10

50

2665

10

28.0

IMD2

CA_1A-28A-42A

CA_1A-28A

1

1955

5

25

2145

5

N/A

FDD

N/A

28

735

5

25

790

5

N/A

FDD

N/A

42

3425

5

25

3425

5

15.0

TDD

IMD3

CA_28A-42A

28

710.5

5

25

765.5

5

N/A

FDD

N/A

42

3560

5

25

3560

5

N/A

TDD

N/A

1

1949

5

25

2139

5

11.0

FDD

IMD3

CA_2A-12A-30A

CA_2A-12A

2

1885

5

25

1965

5

N/A

FDD

N/A

12

708.5

5

25

738.5

5

N/A

N/A

30

2308

5

25

2353

5

12.0

IMD4

CA_2A-2A-4A-5A

CA_2A-5A

2

1900

5

25

1980

5

N/A

FDD

N/A

5

834

5

25

879

5

N/A

N/A

4

1732

5

25

2132

5

7.6

IMD4

CA_2A-4A-13A

CA_2A-13A

2

1855

5

25

1935

5

N/A

FDD

N/A

13

782

5

25

751

5

N/A

N/A

4

1746

5

25

2146

5

7.6

IMD4

CA_4A-13A

4

1750

5

25

2150

5

N/A

FDD

N/A

13

780

5

25

749

5

N/A

N/A

2

1860

5

25

1940

5

6.2

IMD4

CA_2A-2A-5A-66A-66A

CA_2A-5A-66A

CA_2A-5A-66B

CA_2A-5A-66C

CA_2A-5B-66A

CA_2A-5B-66B

CA_2A-5B-66C

CA_2A-2A-5A-66A

CA_2A-2A-5A-66B

CA_2A-2A-5A-66C

CA_2A-5A-66A-66A

CA_2A-5A

2

1900

5

25

1980

5

N/A

FDD

N/A

5

834

5

25

879

5

N/A

N/A

66

1712

5

25

2132

5

7.2

IMD4

CA_2A-5B-66A-66A

CA_2A-5A

2

1900

5

25

1980

5

N/A

FDD

N/A

5

834

5

25

879

5

N/A

N/A

66

1712

5

25

2132

5

7.2

IMD4

CA_2A-13A-66A-66B

CA_2A-13A

2

1860

5

25

1940

5

N/A

FDD

N/A

13

782

5

25

751

5

N/A

N/A

66

1736

5

25

2156

5

7.2

IMD4

CA_2A-48A-66A

CA_48A-66A

2

1880

5

25

1960

5

28.3

FDD-TDD

IMD2

48

3695

5

25

3695

5

N/A

N/A

66

1735

5

25

2135

5

N/A

N/A

CA_3A-5A-7A

CA_3A-5A

3

1780

10

50

1875

10

N/A

FDD

N/A

5

845

5

25

890

5

N/A

N/A

7

2505

10

50

2625

10

30.0

IMD21

CA_3A-7A

3

1725

10

50

1820

10

N/A

FDD

N/A

7

2565

10

50

2685

10

N/A

N/A

5

840

5

25

885

5

19.0

IMD3

CA_3A-7A-8A

CA_3A-7A

3

1735

5

25

1830

5

N/A

FDD

N/A

7

2530

10

50

2650

10

N/A

8

895

5

25

940

5

18.0

IMD3

CA_3A-8A

3

1780

5

25

1875

5

N/A

FDD

N/A

8

890

5

25

935

5

N/A

7

2550

10

50

2670

10

29.0

IMD2+IMD34

CA_3A-7A-20A

CA_3A-7A

3

1737

5

25

1832

5

N/A

FDD

N/A

7

2543

10

50

2663

10

N/A

N/A

20

847

10

20

806

10

10.5

IMD2

CA_3A-20A

3

1775

10

50

1870

10

N/A

FDD

N/A

20

855

5

25

896

5

N/A

N/A

7

2510

10

50

2630

10

26.0

IMD21

CA_3A-7A-26A

CA_3A-7A

3

1720

5

25

1815

5

N/A

FDD

N/A

7

2560

10

50

2680

10

N/A

N/A

26

835

5

25

880

5

17.5

IMD3

CA_3A-7A-26A

CA_3A-26A

3

1780

5

25

1875

5

N/A

FDD

N/A

26

845

5

25

890

5

N/A

N/A

7

2505

10

50

2625

10

29.0

IMD21

CA_3A-7A-28A

CA_3A-7A

3

1747

5

25

1842

5

N/A

FDD

N/A

7

2543

5

25

2663

5

N/A

N/A

28

741

5

25

796.0

5

20.0

IMD2

CA_3A-28A

3

1712.5

5

25

1807.5

5

N/A

FDD

N/A

28

743

5

25

798

5

N/A

N/A

7

2562

5

25

2682

5

17.0

IMD3

CA_7A-28A

7

2543

5

25

2663

5

N/A

FDD

N/A

28

710.5

5

25

765.5

5

N/A

N/A

3

1737.5

5

25

1832.5

5

26.0

IMD2

CA_3A-7A-32A

CA_3A-7A

3

1775

5

25

1870

5

N/A

FDD

N/A

7

2510

10

50

2630

10

N/A

N/A

32

1470

5

10.5

IMD4

CA_3A-8A-38A

CA_3A-8A

3

1720

5

25

1815

5

N/A

FDD-TDD

N/A

8

890

5

25

935

5

N/A

N/A

38

2610

5

25

2610

5

26.4

IMD2

CA_3A-8A

3

1750

5

25

1845

5

N/A

FDD-TDD

N/A

8

900

5

25

945

5

N/A

N/A

38

2600

5

25

2600

5

15.7

IMD3

CA_3A-11A-18A

CA_3A-11A

3

1725

5

25

1820

5

N/A

FDD

N/A

11

1440

5

25

1448

5

N/A

N/A

18

825

5

25

870

5

4.9

IMD5

CA_11A-18A

11

1432

5

25

1481

5

N/A

FDD

N/A

18

820

5

25

865

5

N/A

N/A

3

1753

5

25

1848

5

4.0

IMD5

CA_3A-11A-26A

CA_3A-11A

3

1725

5

25

1820

5

N/A

FDD

N/A

11

1440

5

25

1448

5

N/A

N/A

26

825

5

25

870

5

4.9

IMD5

CA_3A-26A

3

1782.5

5

25

1877.5

5

N/A

FDD

N/A

26

816.5

5

25

861.5

5

N/A

N/A

11

1435.5

5

25

1483.5

5

5.0

IMD5

CA_11A-26A

11

1440

5

25

1488

5

N/A

FDD

N/A

26

824

5

25

869

5

N/A

N/A

3

1761

5

25

1856

5

4.5

IMD5

CA_3A-19A-21A

CA_19A-21A

19

832.5

5

25

877.5

5

N/A

FDD

N/A

21

1460.4

5

25

1508.4

5

N/A

N/A

3

1774.6

5

25

1869.6

5

4.0

IMD5

CA_3A-21A-28A

CA_3A-21A

3

1782

5

25

1877

5

N/A

FDD

N/A

21

1451

5

25

1499

5

N/A

N/A

28

734

5

25

789

5

3.0

IMD5

CA_3A-28A-41A

CA_3A-41

3

1720

5

25

1815

5

N/A

FDD

N/A

41

2510

5

25

2510

5

N/A

TDD

N/A

28

735

5

25

790

5

26.0

FDD

IMD21

CA_3A-41A-42A

CA_41A-42A

41

2640

10

50

2640

10

N/A

TDD

N/A

42

3425

10

50

3425

10

TDD

N/A

3

1760

5

25

1855

5

16.0

FDD

IMD3

CA_5A-46D-66A

CA_5A-46D

5

834

5

25

879

5

N/A

FDD-TDD

N/A

46

5491

20

100

5491

20

N/A

66

1755

5

25

2155

5

0.3

IMD5

CA_19A-21A-42A

CA_19A-21A

19

842.5

5

25

887.5

5

N/A

FDD

N/A

21

1450.4

5

25

1498.4

5

N/A

FDD

N/A

42

3508.7

5

25

3508.7

5

13.0

TDD

IMD4

CA_21A-42A

21

1460.4

5

25

1508.4

5

N/A

FDD

N/A

42

3500

5

25

3500

5

N/A

FDD

N/A

19

836.2

5

25

881.2

5

13.0

TDD

IMD4

CA_28A-41A-42A

CA_41A-42A

41

2672

10

50

2672

10

N/A

TDD

N/A

42

3460

10

50

3460

10

TDD

N/A

28

733

5

25

788

5

26.0

FDD

IMD2

CA_1A-21A-42A6

CA_1A-42A

1

FDD

N/A

42

TDD

N/A

21

FDD

N/A

NOTE 1: This band is subject to IMD3 also which MSD is not specified.

NOTE 1: Both of the transmitters shall be set min(+20 dBm, PCMAX_L,c) as defined in subclause 6.2.5A

NOTE 2: RBSTART = 0

NOTE 3: Void

NOTE 4: This MSD requirement apply with both IMD2 and IMD3 products should be generated.

NOTE 5: For operations with 4 antenna ports, the MSD in the applicable bands shall be modified by the absolute value of ΔRIB,4R in Table 7.3.3-1a when MSD > 0.

NOTE 6: Due to the spectrum holdings of the operator, the deployed frequency ranges do not result MSD to interested downlink channel. Therefore, no requirements apply for this CA configuration.

For intra-band contiguous carrier aggregation the throughput of each component carrier shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.3.3-1, Table 7.3.3-1a, Table 7.3.3-1A, Table 7.3.3-1B, Table 7.3.3-1C, Table 7.3A.0-0h and Table 7.3A.0-1. For operating bands with an unpaired DL part (as noted in Table 5.2-1), the power levels in Table 7.3.1-1 and Table 7.3.3-1a also apply for an SCC assigned in the unpaired part. The requirement is verified using an uplink CA configuration with the largest number of carriers supported by the UE. Table 7.3A.0-0h, Table 7.3A.0-1 and Table 7.3A.0-2 specifies the maximum number of allocated uplink resource blocks for which the intra-band contiguous carrier aggregation reference sensitivity requirement shall be met. The PCC and SCC allocations as defined in Table 7.3A.0-0h, Table 7.3A.0-1 and Table 7.3A.0-2 form a contiguous allocation where TX–RX frequency separations of the component carriers are as defined in Table 5.3-1. In case downlink CA configuration has additional SCC(s) compared to uplink CA configuration those are configured furthers away from uplink band. For UE(s) supporting one uplink carrier, the uplink configuration of the PCC shall be in accordance with Table 7.3.3-2 and the downlink PCC carrier center frequency shall be configured closer to uplink operating band than any of the downlink SCC center frequency. Unless given by Table 7.3.3-3, the reference sensitivity requirements shall be verified with the network signalling value NS_01 (Table 6.2.4.3-1) configured.

Table 7.3A.0-0h: Intra-band contiguous CA uplink configuration for reference sensitivity for Bandwidth Class B

CA configuration / CC combination / NRB_agg / Duplex mode

Uplink CA configuration

25RB+25RB

50RB+25RB

50RB+50RB

75RB+25RB

Duplex Mode

PCC

SCC

PCC

SCC

PCC

SCC

PCC

SCC

CA_5B

N/A

N/A

25

0

25

0

N/A

N/A

FDD

CA_8B

N/A

N/A

25

0

25

0

N/A

N/A

FDD

CA_66B

25

25

50

25

50

50

75

25

FDD

NOTE 1: The carrier centre frequency of SCC in the UL operating band is configured closer to the DL operating band.

NOTE 2: The transmitted power over both PCC and SCC shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 3: The UL resource blocks in both PCC and SCC shall be confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

NOTE 4: The UL resource blocks in PCC shall be located as close as possible to the downlink operating band, while the UL resource blocks in SCC shall be located as far as possible from the downlink operating band.

NOTE 5: In case a CA configuration consists of CC channel bandwidths which are unequal in bandwidth the PCC channel bandwidth shall be the larger one for reference sensitivity test.

Table 7.3A.0-1: Intra-band contiguous CA uplink configuration for reference sensitivity for Bandwidth Class C

CA configuration / CC combination / NRB_agg / Duplex mode

Uplink CA configuration

100RB+25RB

100RB+50RB

75RB+75RB

75RB+50RB

100RB+75RB

100RB+100RB

Duplex Mode

PCC

SCC

PCC

SCC

PCC

SCC

PCC

SCC

PCC

SCC

PCC

SCC

CA_1C

N/A

N/A

N/A

N/A

75

54

N/A

N/A

N/A

N/A

100

30

FDD

CA_3C

50

0

50

0

N/A

N/A

N/A

N/A

50

0

50

0

FDD

CA_7C

N/A

N/A

75

0

75

0

75

0

75

0

75

0

FDD

CA_38C

N/A

N/A

N/A

N/A

75

75

N/A

N/A

N/A

N/A

100

100

TDD

CA_39C

100

25

100

50

N/A

N/A

N/A

N/A

100

75

N/A

N/A

TDD

CA_40C

N/A

N/A

100

50

75

75

N/A

N/A

100

75

100

100

TDD

CA_41C

100

25

100

50

75

75

75

50

100

75

100

100

TDD

CA_42C

100

25

100

50

N/A

N/A

N/A

N/A

100

75

100

100

TDD

CA_48C

100

25

100

50

N/A

N/A

N/A

N/A

100

75

100

100

TDD

CA_66C

100

25

100

50

75

75

75

50

100

75

100

100

FDD

NOTE 1: The carrier centre frequency of SCC in the UL operating band is configured closer to the DL operating band.

NOTE 2: The transmitted power over both PCC and SCC shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 3: The UL resource blocks in both PCC and SCC shall be confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

NOTE 4: The UL resource blocks in PCC shall be located as close as possible to the downlink operating band, while the UL resource blocks in SCC shall be located as far as possible from the downlink operating band.

NOTE 5: In case a CA configuration consists of CC channel bandwidths which are unequal in bandwidth the PCC channel bandwidth shall be the larger one for reference sensitivity test.

NOTE 6: Void.

NOTE 7: Void.

Table 7.3A.0-2: Intra-band contiguous CA uplink configuration for reference sensitivity for Bandwidth Class D

CA configuration / CC combination / NRB_agg / Duplex mode

Uplink CA configuration

CC combination

Number of uplink resource blocks per CC

PCC

SCC

SCC

CA_40D

75RB+75RB+75RB

100RB+75RB+75RB

100RB+100RB+50RB

100RB+100RB+75RB

100RB+100RB+100RB

NOTE 6

CA_41D

75RB+75RB+75RB

100RB+75RB+75RB

100RB+100RB+50RB

100RB+100RB+75RB

100RB+100RB+100RB

NOTE 6

NOTE 1: The carrier centre frequency of SCC in the UL operating band is configured closer to the DL operating band.

NOTE 2: The transmitted power over both PCC and SCC shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 3: The UL resource blocks in both PCC and SCC shall be confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.4.2-1).

NOTE 4: The UL resource blocks in PCC shall be located as close as possible to the downlink operating band, while the UL resource blocks in SCC shall be located as far as possible from the downlink operating band.

NOTE 5: In case a CA configuration consists of CC channel bandwidths which are unequal in bandwidth the PCC channel bandwidth shall be the larger one for reference sensitivity test.

NOTE 6: All uplink CCs are fully allocated

For intra-band non-contiguous carrier aggregation with one uplink carrier and two or more downlink sub-blocks, the throughput of each downlink component carrier shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) and parameters specified in Table 7.3.3-1, Table 7.3.3-1a, Table 7.3.3-1A, Table 7.3.3-1B, Table 7.3.3-1C and Table7.3A.0-3 with the reference sensitivity power level increased by RIBNC given in Table 7.3A.0-3 for the SCC(s). For aggregation of more than two downlink FDD carriers with one uplink carrier the reference sensitivity is defined only for the specific uplink and downlink test points which are specified in Table 7.3A.0-3. The requirements apply with all downlink carriers active. Unless given by Table 7.3.3-3, the reference sensitivity requirements shall be verified with the network signalling value NS_01 (Table 6.2.4.3-1) configured.

Table 7.3A.0-3: Intra-band non-contiguous CA with one uplink configuration for reference sensitivity

CA configuration

Aggregated channel bandwidth (PCC+SCC)

Wgap / [MHz]

UL PCC allocation

ΔRIBNC (dB)

Duplex mode

CA_1A-1A

25RB + 25RB

0.0 < Wgap ≤ 50.0

251

0.5

FDD

25RB + 50RB

0.0 < Wgap ≤ 45.0

251

0.5

25RB + 75RB

0.0 < Wgap ≤ 40.0

251

0.5

25RB + 100RB

0.0 < Wgap ≤ 35.0

251

0.5

50RB + 25RB

0.0 < Wgap ≤ 45.0

501

0.5

50RB + 50RB

0.0 < Wgap ≤ 40.0

501

0.5

50RB + 75RB

0.0 < Wgap ≤ 35.0

501

0.5

50RB + 100RB

0.0 < Wgap ≤ 30.0

501

0.5

75RB + 25RB

0.0 < Wgap ≤ 40.0

751

0.5

75RB + 50RB

0.0 < Wgap ≤ 35.0

751

0.5

75RB + 75RB

0.0 < Wgap ≤ 30.0

751

0.5

75RB + 100RB

0.0 < Wgap ≤ 25.0

751

0.5

100RB + 25RB

20.0 < Wgap ≤ 35.0

901

0.5

0.0 < Wgap ≤ 20.0

1001

0.5

100RB + 50RB

15.0 < Wgap ≤ 30.0

901

0.5

0.0 < Wgap ≤ 15.0

1001

0.5

100RB + 75RB

10.0 < Wgap ≤ 25.0

901

0.5

0.0 < Wgap ≤ 10.0

1001

0.5

100RB + 100RB

5.0 < Wgap ≤ 20.0

901

0.5

0.0 < Wgap ≤ 5.0

1001

0.5

CA_2A-2A

25RB+25RB

30.0 < Wgap ≤ 50.0

121

5.3

FDD

0.0 < Wgap ≤ 30.0

251

0

25RB+50RB

25.0 < Wgap ≤ 45.0

121

4.4

0.0 < Wgap ≤ 25.0

251

0

25RB+75RB

20.0 < Wgap ≤ 40.0

121

4.2

0.0 < Wgap ≤ 20.0

251

0

25RB+100RB

15.0 < Wgap ≤ 35.0

121

3.8

0.0 < Wgap ≤ 15.0

251

0

50RB+25RB

15.0 < Wgap ≤ 45.0

121

5.9

0.0 < Wgap ≤ 15.0

321

0

50RB+50RB

10.0 < Wgap ≤ 40.0

121

4.6

0.0 < Wgap ≤ 10.0

321

0

50RB+75RB

5.0 < Wgap ≤ 35.0

121

4.1

0.0 < Wgap ≤ 5.0

321

0

50RB+100RB

0.0 < Wgap ≤ 30.0

121

4.0

75RB+25RB

10.0 < Wgap ≤ 40.0

1212

6.7

0.0 < Wgap ≤ 10.0

361

0

75RB+50RB

5.0 < Wgap ≤ 35.0

1212

5.4

0.0 < Wgap ≤ 5.0

361

0

75RB+75RB

0.0 < Wgap ≤ 30.0

1212

4.6

75RB+100RB

0.0 < Wgap ≤ 25.0

1212

4.2

100RB+25RB

0.0 < Wgap ≤ 35.0

1613

7.2

100RB+50RB

0.0 < Wgap ≤ 30.0

1613

5.8

100RB+75RB

0.0 < Wgap ≤ 25.0

1613

5.0

100RB+100RB

0.0 < Wgap ≤ 20.0

1613

4.6

CA_3A-3A

15RB+25RB

47.0 < Wgap ≤ 67.0

121

4.5

FDD

0.0 < Wgap ≤ 47.0

151

0

25RB+15RB

47.0 < Wgap ≤ 67.0

121

4.9

0.0 < Wgap ≤ 47.0

251

0

25RB+25RB

45.0 < Wgap ≤ 65.0

121

4.7

0.0 < Wgap ≤ 45.0

251

0

25RB+50RB

40.0 < Wgap ≤ 60.0

121

3.8

0.0 < Wgap ≤ 40.0

251

0

25RB+75RB

35.0 < Wgap ≤ 55.0

121

3.6

0.0 < Wgap ≤ 35.0

251

0

25RB+100RB

30.0 < Wgap ≤ 50.0

121

3.4

0.0 < Wgap ≤ 30.0

251

0

50RB+25RB

30.0 < Wgap ≤ 60.0

129

5.1

0.0 < Wgap ≤ 30.0

321

0

50RB+50RB

25.0 < Wgap ≤ 55.0

129

4.3

0.0 < Wgap ≤ 25.0

321

0

50RB+75RB

20.0 < Wgap ≤ 50.0

129

3.8

0.0 < Wgap ≤ 20.0

321

0

50RB+100RB

15.0 < Wgap ≤ 45.0

129

3.4

0.0 < Wgap ≤ 15.0

321

0

75RB+25RB

25.0 < Wgap ≤ 55.0

1210

6.0

0.0 < Wgap ≤ 25.0

321

0

75RB+50RB

20.0 < Wgap ≤ 50.0

1210

4.7

0.0 < Wgap ≤ 20.0

321

0

75RB+75RB

15.0 < Wgap ≤ 45.0

1210

4.2

0.0 < Wgap ≤ 15.0

321

0

75RB+100RB

10.0 < Wgap ≤ 40.0

1210

3.8

0.0 < Wgap ≤ 10.0

321

0

100RB+25RB

15.0 < Wgap ≤ 50.0

1611

6.5

0.0 < Wgap ≤ 15.0

321

0

100RB+50RB

10.0 < Wgap ≤ 45.0

1611

5.1

0.0 < Wgap ≤ 10.0

321

0

100RB+75RB

5.0 < Wgap ≤ 40.0

1611

4.5

0.0 < Wgap ≤ 5.0

321

0

100RB+100RB

0.0 < Wgap ≤ 35.0

1611

4.1

CA_4A-4A

NOTE 6

NOTE 7

NOTE 8

0.0

FDD

CA_5A-5A

25RB+25RB

NOTE 7

121

5.3

FDD

25RB+50RB

NOTE 7

121

4.4

50RB+25RB

NOTE 7

121

5.9

50RB+50RB

NOTE 7

121

4.6

CA_7A-7A

25RB+25RB

0< Wgap ≤ 60

25

0.0

FDD

25RB+50RB

0 < Wgap ≤ 55

25

0.0

25RB+75RB

0 < Wgap ≤ 50

25

0.0

25RB+100RB

0 < Wgap ≤ 45

25

0.0

50RB+25RB

30 < Wgap ≤ 55

321

0.0

0 < Wgap ≤ 30

50

0.0

50RB+50RB

25.0 < Wgap ≤ 50.0

321

0.0

0.0 < Wgap ≤ 25.0

50

0.0

50RB+75RB

20 < Wgap ≤ 45

321

0.0

0 < Wgap ≤ 20

50

0.0

50RB+100RB

15 < Wgap ≤ 40

321

0.0

0 < Wgap ≤ 15

50

0.0

75RB+25RB

20.0 < Wgap ≤ 50.0

321

0.0

0.0 < Wgap ≤ 20.0

501

0.0

75RB+50RB

20.0 < Wgap ≤ 45.0

321

0.0

0.0 < Wgap ≤ 20.0

501

0.0

75RB+75RB

15.0 < Wgap ≤ 40.0

321

0.0

0.0 < Wgap ≤ 15.0

501

0.0

75RB+100RB

10 < Wgap ≤ 35

321

0.0

0 < Wgap ≤ 10

501

0.0

100RB+25RB

25 < Wgap ≤ 45

321

0.0

0 < Wgap ≤ 25

451

0.0

100RB+50RB

20 < Wgap ≤ 40

321

0.0

0 < Wgap ≤ 20

451

0.0

100RB+75RB

15.0 < Wgap ≤ 35.0

361

0.0

0.0 < Wgap ≤ 15.0

501

0.0

100RB+100RB

15.0 < Wgap ≤ 30.0

321

0.0

0.0 < Wgap ≤ 15.0

451

0.0

CA_12A-12A

25RB+25RB

0.0 < Wgap ≤ 7.0

518

3

FDD

CA_23A-23A

NOTE 6

NOTE 7

NOTE 8

0.0

FDD

CA_25A-25A

25RB+25RB

30.0 < Wgap ≤ 55.0

101

5.0

FDD

0.0 < Wgap ≤ 30.0

251

0.0

25RB+50RB

25.0 < Wgap ≤ 50.0

101

4.5

0.0 < Wgap ≤ 25.0

251

0.0

25RB+75RB

20 < Wgap ≤ 45

101

4.3

0 < Wgap ≤ 20

251

0

25RB+100RB

15 < Wgap ≤ 40

101

4.1

0 < Wgap ≤ 15

251

0

50RB+25RB

15.0 < Wgap ≤ 50.0

104

5.5

0.0 < Wgap ≤ 15.0

321

0.0

50RB+50RB

10.0 < Wgap ≤ 45.0

104

5.0

0.0 < Wgap ≤ 10.0

321

0.0

50RB+75RB

5 < Wgap ≤ 40

104

4.5

0 < Wgap ≤ 5

321

0

50RB+100RB

0 < Wgap ≤ 35

104

4.2

75RB+25RB

10 < Wgap ≤ 45

1014

7.6

0 < Wgap ≤ 10

321

0

75RB+50RB

5 < Wgap ≤ 40

1014

6.7

0 < Wgap ≤ 5

321

0

75RB+75RB

0 < Wgap ≤ 35

1014

5.6

75RB+100RB

0 < Wgap ≤ 30

1014

4.8

100RB+25RB

0 < Wgap ≤ 40

1215

8

100RB+50RB

0 < Wgap ≤ 35

1215

6.7

100RB+75RB

0 < Wgap ≤ 30

1215

6.1

100RB+100RB

0 < Wgap ≤ 25

1215

5.7

CA_25A-25A-25A

25RB+25RB+25RB

Wgap_L = Wgap_H = 25 MHz

101

5.0

FDD

Wgap_L = Wgap_H = 5 MHz

251

0.0

50RB+50RB+50RB

Wgap_L = Wgap_H = 17.5 MHz

104

5.0

75RB+75RB+75RB

Wgap_L = Wgap_H = 10 MHz

1014

5.6

100RB+100RB+100RB

Wgap_L = Wgap_H = 2.5 MHz

1215

5.7

CA_40A-40A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_40A-40C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_40C-40C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41A-41A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41A-41C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41A-41D

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41C-41C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41A-41A-41A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_41A-41A-41C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_42A-42A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_42A-42C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_42A-42D

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_42C-42C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48A-48A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48A-48A-48A

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48D

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48A-48E

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48C-48C

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_48C-48D

NOTE 6

NOTE 7

NOTE 8

0.0

TDD

CA_66A-66A

NOTE 6

NOTE 7

NOTE 8, NOTE 16

0.0

FDD

CA_66A-66A-66A

NOTE 6

NOTE 7

NOTE 8, NOTE 16

0.0

FDD

CA_66A-66B

NOTE 6

NOTE 7

NOTE 8, NOTE 16

0.0

FDD

CA_66A-66C

NOTE 6

NOTE 7

NOTE 8, NOTE 16

0.0

FDD

NOTE 1: 1 refers to the UL resource blocks shall be located as close as possible to the downlink operating band but confined within the transmission.

NOTE 2: Wgap is the sub-block gap between the two sub-blocks.

NOTE 3: The carrier center frequency of PCC in the UL operating band is configured closer to the DL operating band.

NOTE 4: 4 refers to the UL resource blocks shall be located at RBstart=33.

NOTE 5: For the TDD intra-band non-contiguous CA configurations, the minimum requirements apply only in synchronized operation between all component carriers.

NOTE 6: All combinations of channel bandwidths defined in Table 5.4.2A.1-3.

NOTE 7: All applicable sub-block gap sizes.

NOTE 8: The PCC allocation is same as Transmission bandwidth configuration NRB as defined in Table 5.4.2-1. In case of uplink sub-block is TDD intra-band contiguous CA then the uplink PCC and SCC allocations are the same as NRB_agg defined in Table 7.3A.0-1.

NOTE 9: 9 refers to the UL resource blocks shall be located at RBstart=25.

NOTE 10: 10 refers to the UL resource blocks shall be located at RBstart=35.

NOTE 11: 11 refers to the UL resource blocks shall be located at RBstart=50.

NOTE 12: 12 refers to the UL resource blocks shall be located at RBstart=39.

NOTE 13: 13 refers to the UL resource blocks shall be located at RBstart=57.

NOTE 14: 14 refers to the UL resource blocks shall be located at RBstart=44.

NOTE 15: 15 refers to the UL resource blocks shall be located at RBstart=62.

NOTE 16: The carrier center frequency of PCC in the DL operating band is configured closer to the UL operating band.

NOTE 17: Void

NOTE 18: 18 refers to the UL resource blocks shall be located at RBstart=12.

NOTE 19: For operations with 4 antenna ports, the MSD in the applicable bands shall be modified by the absolute value of ΔRIB,4R in Table 7.3.3-1a when MSD > 0.

For intra-band non-contiguous carrier aggregation with two uplink and downlink carriers the reference sensitivity is defined to be met with both downlink and uplink carriers activated. The downlink PCC and SCC minimum requirements for reference sensitivity power level as specified in Table 7.3.3-1, Table 7.3.3-1a, Table 7.3.3-1A, Table 7.3.3-1B and Table 7.3.3-1C are increased by amount of ΔR2UL_PCC and ΔR2UL_SCC which are defined in Table 7.3A.0-4 when uplink PCC and SCC allocations are according to the Table 7.3A.0-4.

Table 7.3A.0-4: Intra-band non-contiguous CA with two uplinks configuration for reference sensitivity

CA configuration

Aggregated channel bandwidth (PCC+SCC)

Wgap / [MHz]

UL PCC allocation

UL SCC allocation

ΔR2UL_PCC

(dB)

ΔR2UL_SCC

(dB)

Duplex mode

CA_4A-4A

NOTE 2

NOTE 3

NOTE 4

NOTE 5

0.0

0.0

FDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: All combinations of channel bandwidths defined in Table 5.4.2A.1-3.

NOTE 3: All applicable sub-block gap sizes.

NOTE 4: The PCC allocation is same as Transmission bandwidth configuration NRB as defined in Table 5.4.2-1.

NOTE 5: The SCC allocation is same as Transmission bandwidth configuration NRB as defined in Table 5.4.2-1.

For combinations of intra-band and inter-band carrier aggregation, the requirement is defined with an uplink configuration in accordance with Table 7.3A.0-3 when the uplink is active in the band supporting two or more non-contiguous component carriers, Table 7.3A.0-1 when the uplink (up to two contiguously aggregated uplink carriers) is active in a band supporting two contiguous component carriers and in accordance with Table 7.3.3-2 when an uplink is active in a band supporting one carrier per band. The downlink PCC shall be configured closer to the uplink operating band than the downlink SCC(s) when the uplink is active in band(s) supporting contiguous aggregation. The carrier center frequency of PCC in the UL operating band is configured closer to the DL operating band when the uplink is active in band(s) supporting non-contiguous aggregation. For these uplink configurations, the UE shall meet the reference sensitivity requirements for intra-band non-contiguous carrier aggregation of two or more downlink sub-blocks, the requirements for intra-band contiguous carrier aggregation for the contiguously aggregated downlink carriers and for any remaining component carrier(s) the requirements specified in subclause 7.3.3. For the two or more component carriers within the same band, RIBNC = 0 dB for all sub-block gaps (Table 7.3A.0-3) when the uplink is active in another band. All downlink carriers shall be active throughout the tests and the requirements for the downlinks shall be met with all uplink carriers active in each band capable of UL operation. For component carriers configured in Band 46, the said requirements for intra-band carrier aggregation of downlink carriers are replaced by the requirements in Table 7.3A.0-0eA for the uplink in any band other than band 46 with the uplink configuration specified in Table 7.3.3-2. Unless given by Table 7.3.3-3, the reference sensitivity requirements shall be verified with the network signalling value NS_01 (Table 6.2.4.3-1) configured.

For the UE that supports any of combinations of intra-band and inter-band carrier aggregation given in Table 7.3A.0-5, exceptions to the requirements for a band(s) specified in subclause 7.3.3 are allowed when the band(s) is impacted by harmonic interference from the uplink being active in a lower-frequency band of the same CA configuration. For these exceptions, the UE shall meet the requirements specified in Table 7.3A.0-5 and Table 7.3A.0-6.

Table 7.3A.0-5: Reference sensitivity for carrier aggregation QPSK PREFSENS, CA (exceptions due to harmonic issues in the combinations of intra-band and inter-band CA)

Channel bandwidth

EUTRA CA Configuration

EUTRA band

1.4 MHz
(dBm)

3 MHz
(dBm)

5 MHz
(dBm)

10 MHz
(dBm)

15 MHz
(dBm)

20 MHz
(dBm)

Duplex mode

CA_1A-3A-3A-7A-8A4

CA_1A-3A-7A-7A-8A4

CA_1A-3A-3A-7A-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-3A-7A-8A5,6

CA_1A-3A-7A-7A-8A5,6

CA_1A-3A-3A-7A-7A-8A5,6

733

-88

-87.4

-87

-86.7

FDD

CA_1A-3A-7C-28A5,6

CA_1A-3C-7A-28A5,6

CA_1A-3C-7C-28A 5,6

CA_1A-3A-3A-7A-28A5,6

CA_1A-3A-7A-7A-28A5,6

121

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3C-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_1A-3A-18A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-18A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-19A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-19A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-3A-20A-28A

121

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-21A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-21A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3C-28A

121

-89.8

-89.4

-89

-88.7

FDD

CA_1A-3A-28A-40C16,17

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_1A-3A-28A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-28A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-41A-42C8,9

CA_1A-3A-41C-42A8,9

CA_1A-3A-41C-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-41A-42C10

CA_1A-3A-41C-42A10

CA_1A-3A-41C-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-3A-42D8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_1A-7A-8A-40C5,6

733

-87.1

-86.7

-86.4

FDD

CA_1A-7C-28A5,6

121

-89.8

-89.4

-89

-88.7

FDD

CA_1A-7A-28A-40C16,17

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_1A-3A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-42D10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-3A-42C9,10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-3A-3A-42C11

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_1A-21A-28A-42C4, 14

21

N/A

N/A

N/A

FDD

42

N/A

N/A

N/A

N/A

TDD

CA_1A-28A-42C5,6,12,13

121

-89.8

-89.4

-89

-88.7

FDD

42

-85.7

-85.4

-85.1

-84.9

TDD

CA_2A-2A-4A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_2A-2A-5A-12A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-2A-7A-12A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-2A-12A-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-13A-48A-48A8,9
CA_2A-13A-48C8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48A-48A10
CA_2A-13A-48C10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-7A-12B-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-2A-12A-30A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-2A-12A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-2A-12B-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-12A-30A-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-12B-66A5,6

1621

-89.5

-89

-88.5

-88

FDD

CA_2A-12B-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-4A-4A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-12A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_2A-4A-12B5,6

421

-90

-89.5

-89

-88.5

FDD

CA_2A-48A-48C9, 22

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48C1

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48A-48D8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48D10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48C-48C8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48C-48C10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48D9, 22

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48D10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48E8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48E10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-12A-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-12A-66C5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_2A-13A-48D8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48D10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-13A-48A-48C8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48A-48C10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-13A-48C-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48C-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-13A-48A-48A-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-13A-48A-48A-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48D-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48D-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48E-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48E-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48A-48A-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48A-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_2A-48A-48C-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_2A-48A-48C-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-3A-7A-7A-8A4

3

N/A

N/A

N/A

N/A

CA_3A-3A-7A-7A-8A5,6

721

-88

-87,4

-87

-86,7

FDD

CA_3A-3A-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-3A-7A-8A5,6

721

-88

-87.4

-87

-86.7

FDD

CA_3A-3A-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_3A-7A-7A-8A4

3

N/A

N/A

N/A

N/A

FDD

7

N/A

N/A

N/A

N/A

CA_3A-7A-7A-8A4,5,6

3

-97

-94

-92.2

-91

FDD

721

-88

-87.4

-87

-86.7

CA_3C-7A-8A-38A4

3

N/A

N/A

N/A

N/A

FDD

7

N/A

N/A

N/A

N/A

CA_3A-7A-8A-40C4

3

N/A

N/A

N/A

N/A

FDD

7

N/A

N/A

N/A

CA_3A-7A-8A-40C5,6

733

-87.1

-86.7

-86.4

FDD

CA_3A-7A-28A-40C16,17

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_3A-19A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-19A-42C10

4221

-97.1

-94.7

-93.2

-92.5

CA_3A-19A-42D8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-19A-42D10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-21A-42C1,2

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-21A-42C3

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-21A-42D8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-21A-42D10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-40C8,9

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_3A-28A-40D8,9

28

-60.7

-60.7

-60.7

-60.7

FDD

CA_3A-28A-41A-42C8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-28A-41A-42C10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-28A-41A-42C12,13,20

4221

-85.4

-85.1

-84.9

TDD

CA_3A-28A-41C-42A8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-28A-41C-42A10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-28A-41C-42A12,13,20

4221

-85.4

-85.1

-84.9

TDD

CA_3A-28A-41C-42C8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-28A-41C-42C10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-28A-41C-42C12,13,20

4221

-85.4

-85.1

-84.9

TDD

CA_3A-28A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42C12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-28A-42D8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42D10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42D12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-28A-42A-42A8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42A-42A10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42A-42A12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-28A-42A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42A-42C12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-28A-42C-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-28A-42C-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-28A-42C-42C12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_3A-41A-42A-42A8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-41A-42A-42A10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-41A-42A-42C8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-41A-42A-42C10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-41A-42C-42C8,9,20

4221

-71.7

-71.7

-71.7

TDD

CA_3A-41A-42C-42C10,20

4221

-94.7

-93.2

-92.5

TDD

CA_3A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42D8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42D10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-3A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-3A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-3A-42D9,10

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-3A-42D11

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42A-42C8,9

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42A-42C10

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42C-42C8, 9,10

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42C-42C11

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3A-42E9,10

4221

-71.7

-71.7

-71.7

-71.7

TDD

CA_3A-42E11

4221

-97.1

-94.7

-93.2

-92.5

TDD

CA_3C-8A4

3

N/A

N/A

N/A

N/A

FDD

CA_4A-4A-5A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-4A-12A5,6

4

-90

-89.5

-89

-88.5

FDD

CA_4A-4A-12A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-4A-12A-30A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-4A-12B5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-5A-12B5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-12A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-12B5,6

421

-90

-89.5

-89

-88.5

FDD

CA_4A-5A-12A-12A5,6

421

-90

-89.5

-89

-88.5

FDD

CA_7A-7A-8A5,6

721

-88

-87.4

-87

-86.7

FDD

CA_8A-41C7

41

N/A

N/A

N/A

TDD

CA_8A-42C15,16

4221

-84.8

-84.7

-84.6

-84.5

TDD

CA_12A-30A-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_12A-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_12A-66C5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_12B-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_12B-66A-66A5,6

6621

-89.5

-89

-88.5

-88

FDD

CA_20A-38A-40A-40A15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-38A-40C15,16

20

-60.7

-60.7

-60.7

FDD

CA_20A-40D7

20

-60.7

-60.7

-60.7

FDD

CA_21A-28A-42C4,14

21

N/A

N/A

N/A

N/A

FDD

42

N/A

N/A

TDD

CA_25A-25A-26A-41C7

41

N/A

N/A

N/A

N/A

TDD

CA_26A-41C7

41

N/A

N/A

N/A

N/A

TDD

CA_28A-40C16,17

2821

-60.7

-60.7

-60.7

-60.7

FDD

CA_28A-40D16,17

2821

-60.7

-60.7

-60.7

-60.7

FDD

CA_28A-41A-42C12, 13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-41C-42A12, 13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-41C-42C12,13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-42C12,13

CA_28A-42D12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_28A-41A-42A-42A12, 13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-41A-42A-42C12, 13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-41A-42A-42C12, 13

4221

-85.4

-85.1

-84.9

TDD

CA_28A-42A-42A12,13

CA_28A-42A-42C12,13

CA_28A-42C-42C12,13

4221

-85.7

-85.4

-85.1

-84.9

TDD

CA_48A-48C-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48C-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48C-66B 8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48C-66B 10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48C-66C 8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48C-66C 10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48A-48D-66A 8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48A-48D-66A 10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48C-48C-66A 8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48C-48C-66A 10

48

-97.1

-94.7

-93.2

-92.5

TDD

CA_48D-66A8,9

48

-71.7

-71.7

-71.7

-71.7

TDD

CA_48D-66A10

48

-97.1

-94.7

-93.2

-92.5

TDD

NOTE 1: The transmitter shall be set to PUMAX as defined in subclause 6.2.5A.

NOTE 2: Reference measurement channel is A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1

NOTE 3: The signal power is specified per port

NOTE 4: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity for all active downlink component carriers is only verified when this is not the case (the requirements specified in clause 7.3.3 apply unless otherwise specified).

NOTE 5: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 6: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 7: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 3rd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity is only verified when this is not the case (the requirements specified in clause 7.3.3 apply).

NOTE 8: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_3A-42C, CA_3A-42D, CA_3A-3A-42C, CA_3A-42A-42C, CA_3A-42C-42C, CA_1A-3A-18A-42C, CA_1A-3A-19A-42C, CA_1A-3A-21A-42C, CA_1A-3A-41A-42C, CA_1A-3A-41C-42A, CA_1A-3A-41C-42C, CA_1A-3A-42C, CA_3A-28A-42C, CA_3A-28A-42D, CA_3A-19A-42C, CA_3A-19A-42D, CA_3A-21A-42D, CA_3A-28A-40C, CA_3A-28A-40D, CA_3A-28A-41A-42C, CA_3A-28A-41C-42A, CA_3A-28A-41C-42C, CA_3A-28A-42A-42A, CA_3A-28A-42A-42C, CA_3A-28A-42C-42C, CA_3A-41A-42A-42A, CA_3A-41A-42A-42C, CA_3A-41A-42C-42C, CA_2A-48C-48C, CA_2A-48A-48D, CA_48A-48C-66C, CA_48A-48C-66B, CA_48A-48D-66A, CA_48C-48C-66A, CA_48D-66A, CA_48A-48C-66A, CA_2A-13A-48D, CA_2A-13A-48A-48C, CA_2A-13A-48C-66A, CA_2A-13A-48A-48A-66A, CA_2A-48D-66A, CA_2A-48E-66A, CA_2A-48A-48C-66A and CA_2A-48E.

NOTE 9: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band.

NOTE 10: The requirements are only applicable to channel bandwidths with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively.

NOTE 11: Void

NOTE 12: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 5th transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 13: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 14: No requirements apply when there is at least one individual RE on band 28 uplink outside frequencies 728 – 738 MHz. The reference sensitivity is only verified when all configured RE’s are confined within frequencies 728 – 738 MHz (the requirements specified in clause 7.3.1 of [6] apply).

NOTE 15: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of a low band for which the 4th transmitter harmonic is within the downlink transmission bandwidth of a high band.

NOTE 16: The requirements should be verified for UL EARFCN of a low band (superscript LB) such that in MHz and with the carrier frequency of a high band in MHz and the channel bandwidth configured in the low band.

NOTE 17: These requirements apply when there is at least one individual RE within the downlink transmission bandwidth of the victim (lower) band for which the 3rd harmonic is within the uplink transmission bandwidth or the uplink adjacent channel’s transmission bandwidth of an aggressor (higher) band.

NOTE 18: The requirements should be verified for UL EARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with  the carrier frequency in the victim (lower) band and  the channel bandwidth configured in the higher band.

NOTE 19: The requirement for B46 does not apply when there is at least one individual RE within the B46 downlink transmission bandwidth which falls into the reference sensitivity exclusion region as specified in Table 6.2.4.3-3.

NOTE 20: The B41 requirements are modified by -0.1dB when carrier frequency of the assigned E-UTRA channel bandwidth is within 2545-2690 MHz.

NOTE 21: Applicable for the operations with 2 or 4 antenna ports supported in the band with carrier aggregation configured.

NOTE 22: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band and a range FHD above and below the edge of this downlink transmission bandwidth. The value FHD depends on the E-UTRA configuration: FHD = 10 MHz for CA_2A-48A-48C

Table 7.3A.0-6: Uplink configuration for the low band (exceptions due to harmonic issues in the combinations of intra-band and inter-band CA)

E-UTRA Band / Channel bandwidth of the high band / NRB / Duplex mode

EUTRA CA Configuration

UL band

1.4 MHz

3 MHz

5 MHz

10 MHz

15 MHz

20 MHz

Duplex mode

CA_1A-3A-3A-7A-8A

CA_1A-3A-7A-7A-8A

CA_1A-3A-3A-7A-7A-8A

8

8

16

25

25

FDD

CA_1A-3A-7C-28A

CA_1A-3C-7A-28A

CA_1A-3C-7C-28A

CA_1A-3A-3A-7A-28A

CA_1A-3A-7A-7A-28A

28

16

25

25

FDD

CA_1A-3A-18A-42C

3

12

25

36

50

FDD

CA_1A-3A-19A-42C

3

12

25

36

50

FDD

CA_1A-3A-3A-20A-28A

28

8

16

25

25

FDD

CA_1A-3A-21A-42C

3

12

25

36

50

FDD

CA_1A-3C-28A

28

8

16

25

25

FDD

CA_1A-3A-28A-40C

40

25

50

75

100

TDD

CA_1A-3A-28A-42C

3

12

25

36

50

FDD

CA_1A-3A-42C

3

12

25

36

50

FDD

CA_1A-3A-42D

3

12

25

36

50

FDD

CA_1A-3A-3A-42C

3

12

25

36

50

FDD

CA_1A-7A-8A-40C

8

8

16

25

25

FDD

CA_1A-7C-28A

28

16

25

25

FDD

CA_1A-7A-28A-40C

40

25

50

75

100

TDD

CA_1A-28A-42C

28

8

16

25

25

FDD

CA_2A-2A-4A-12A

12

8

16

20

20

FDD

CA_2A-2A-5A-12A-66A

12

8

16

20

20

FDD

CA_2A-2A-7A-12A-66A

12

8

16

FDD

CA_2A-2A-12A-30A-66A

12

8

16

25

25

FDD

CA_2A-2A-12A-66A

12

8

16

FDD

CA_2A-2A-12A-66A-66A

12

8

16

20

20

FDD

CA_2A-2A-12B-66A

12

8

16

20

20

FDD

CA_2A-4A-4A-12A

12

8

16

20

20

FDD

CA_2A-4A-12A-12A

12

8

16

20

20

FDD

CA_2A-4A-12B

12

8

16

FDD

CA_2A-7A-12B-66A

12

8

16

FDD

CA_2A-12A-30A-66A-66A

12

8

16

25

25

FDD

CA_2A-12A-66A-66A

12

8

16

FDD

CA_2A-12A-66C

12

8

16

FDD

CA_2A-12B-66A

12

8

16

20

20

FDD

CA_2A-12B-66A-66A

12

8

16

20

20

FDD

CA_2A-13A-48A-48A

CA_2A-13A-48C

2

25

50

501

501

FDD

CA_2A-13A-48D

2

25

50

501

501

FDD

CA_2A-13A-48A-48C

2

25

50

501

501

FDD

CA_2A-13A-48C-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-13A-48A-48A-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-48A-48D

2

25

50

501

501

FDD

CA_2A-48C-48C

2

25

50

501

501

FDD

CA_2A-48D

2

25

50

501

501

FDD

CA_2A-48E

2

25

50

501

501

FDD

CA_2A-48A-48A-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-48D-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-48E-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_2A-48A-48C-66A

2

25

50

501

501

FDD

66

121

251

361

501

FDD

CA_3A-3A-7A-7A-8A

8

8

16

25

25

FDD

CA_3A-3A-7A-8A

8

8

16

25

25

FDD

CA_3A-7A-7A-8A

8

8

16

25

25

FDD

CA_3A-7A-8A-40C

8

8

16

25

25

FDD

CA_3A-19A-42C

3

12

25

36

50

FDD

CA_3A-19A-42D

3

12

25

36

50

FDD

CA_3A-7A-28A-40C

40

25

50

75

100

TDD

CA_3A-42C

3

12

25

36

50

FDD

CA_3A-3A-42D

3

12

25

36

50

FDD

CA_3A-42C-42C

3

12

25

36

50

FDD

CA_3A-42E

3

12

25

36

50

FDD

CA_3A-21A-42C

3

12

25

36

50

FDD

CA_3A-21A-42D

3

12

25

36

50

FDD

CA_3A-28A-40C

40

25

50

75

100

TDD

CA_3A-28A-40D

40

50

75

100

TDD

CA_3A-28A-41A-42C

3

25

36

50

FDD

28

10

15

20

FDD

CA_3A-28A-41C-42A

3

25

36

50

FDD

28

10

15

20

FDD

CA_3A-28A-41C-42C

3

25

36

50

FDD

28

10

15

20

FDD

CA_3A-28A-42C

3

12

25

36

50

FDD

28

5

10

15

20

FDD

CA_3A-28A-42A-42A

3

12

25

36

50

FDD

28

5

10

15

20

FDD

CA_3A-28A-42A-42C

3

12

25

36

50

FDD

28

5

10

15

20

FDD

CA_3A-28A-42C-42C

3

12

25

36

50

FDD

28

5

10

15

20

FDD

CA_3A-41A-42A-42A

3

25

36

50

FDD

CA_3A-41A-42A-42C

3

25

36

50

FDD

CA_3A-41A-42C-42C

3

25

36

50

FDD

CA_4A-4A-5A-12A

12

8

16

20

20

FDD

CA_4A-4A-12A

12

8

16

20

20

FDD

CA_4A-4A-12A-12A

12

8

16

20

20

FDD

CA_4A-4A-12A-30A

12

8

16

20

20

FDD

CA_4A-4A-12B

12

8

16

FDD

CA_4A-12A-12A

12

8

16

20

20

FDD

CA_4A-12B

12

8

16

20

20

FDD

CA_4A-5A-12A-12A

12

8

16

20

20

FDD

CA_4A-5A-12B

12

8

16

FDD

CA_7A-7A-8A

8

8

16

25

25

FDD

CA_8A-42C

8

8

16

25

25

FDD

CA_12A-30A-66A-66A

12

8

16

FDD

CA_12A-66A-66A

12

8

16

20

20

FDD

CA_12A-66C

12

8

16

20

20

FDD

CA_12B-66A

12

8

16

20

20

FDD

CA_12B-66A-66A

12

8

16

20

20

FDD

CA_20A-38A-40A-40A3

40

25

50

75

TDD

CA_20A-38A-40C3

40

25

50

75

TDD

CA_20A-40D3

40

25

50

75

TDD

CA_28A-40C

40

25

50

75

100

TDD

CA_28A-40D

40

25

50

75

100

TDD

CA_28A-41A-42C

28

10

15

20

FDD

CA_28A-41C-42A

28

10

15

20

FDD

CA_28A-41C-42C

28

10

15

20

FDD

CA_28A-41A-42A-42A

28

10

15

20

FDD

CA_28A-41A-42A-42C

28

10

15

20

FDD

CA_28A-41A-42C-42C

28

10

15

20

FDD

CA_28A-42C

CA_28A-42D

28

5

10

15

20

FDD

CA_28A-42A-42A

CA_28A-42A-42C

CA_28A-42C-42C

28

5

10

15

20

FDD

CA_48A-48C-66A

66

12

25

36

50

FDD

CA_48A-48C-66B

66

12

25

36

50

FDD

CA_48A-48C-66C

66

12

25

36

50

FDD

CA_48A-48D-66A

66

12

25

36

50

FDD

CA_48C-48C-66A

66

12

25

36

50

FDD

CA_48D-66A

66

12

25

36

50

FDD

NOTE 1: refers to the UL resource blocks, which shall be centred within the transmission bandwidth configuration for the channel bandwidth.

NOTE 2: the UL configuration applies regardless of the channel bandwidth of the low band unless the UL resource blocks exceed that specified in Table 7.3.3-2 for the uplink bandwidth in which case the allocation according to Table 7.3.3-2 applies.

NOTE 3: refers to the UL resource blocks shall be located between 2373-2400MHz.

The normative reference for this requirement is TS 36.101[2] clause 7.3.1 and 7.3.1A.