6.3.5EB Power Control for UE category 1bis

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

6.3.5EB.1 Power Control Absolute power tolerance for UE category 1bis

6.3.5EB.1.1 Test purpose

Same test purpose as in clause 6.3.5.1.1.

6.3.5EB.1.2 Test applicability

This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.

6.3.5EB.1.3 Minimum conformance requirement

Same minimum conformance requirements as in clause 6.3.5.1.2.

6.3.5EB.1.4 Test description
6.3.5EB.1.4.1 Initial conditions

Same initial conditions as in clause 6.3.5.1.4.1 with the following exceptions:

– Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.

6.3.5EB.1.4.2 Test procedure

Same test procedure as in clause 6.3.5.1.4.2.

6.3.5EB.1.4.3 Message contents

Same message contents as in clause 6.3.5.1.4.3.

6.3.5EB.1.5 Test requirements

The requirement for the power measured in step (2) of the test procedure is not to exceed the values specified in Table 6.3.5EB.1.5-1 and 6.3.5EB.1.5-2.

Table 6.3.5EB.1.5-1: Absolute power tolerance: test point 1

Channel bandwidth / expected output power (dBm)

1.4

MHz

3.0

MHz

5

MHz

10

MHz

15

MHz

20

MHz

Expected Measured power Normal conditions

-14.8 dBm

-10.8 dBm

-8.6 dBm

-5.6 dBm

-3.9 dBm

-2.6 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

Expected Measured power Extreme conditions

-14.8 dBm

-10.8 dBm

-8.6 dBm

-5.6 dBm

-3.9 dBm

-2.6 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

Note 1: The lower power limit shall not exceed the minimum output power requirements defined in sub-clause 6.3.2EB.3

Table 6.3.5EB.1.5-2: Absolute power tolerance: test point 2

Channel bandwidth / expected output power (dBm)

1.4

MHz

3.0

MHz

5

MHz

10

MHz

15

MHz

20

MHz

Expected Measured power Normal conditions

-2.8 dBm

1.2 dBm

3.4 dBm

6.4 dBm

8.2 dBm

9.4 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

Expected Measured power Extreme conditions

-2.8 dBm

1.2 dBm

3.4 dBm

6.4 dBm

8.2 dBm

9.4 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

Note 1: The upper power limit shall not exceed the maximum output power requirements defined in sub-clause 6.2.2EB.3

6.3.5EB.2 Power Control Relative power tolerance for UE category 1bis

6.3.5EB.2.1 Test purpose

Same test purpose as in clause 6.3.5.2.1.

6.3.5EB.2.2 Test applicability

This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.

6.3.5EB.2.3 Minimum conformance requirement

Same minimum conformance requirements as in clause 6.3.5.2.3.

6.3.5EB.2.4 Test description
6.3.5EB.2.4.1 Initial conditions

Same initial conditions as in clause 6.3.5.2.4.1 with the following exceptions:

– Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.

6.3.5EB.2.4.2 Test procedure

Same test procedure as in clause 6.3.5.2.4.2.

6.3.5EB.2.4.3 Message contents

Same message contents as in clause 6.3.5.2.4.3.

6.3.5EB.2.5 Test requirements

Same test requirements as in clause 6.3.5.2.5.

6.3.5EB.3 Aggregate power control tolerance for UE category 1bis

6.3.5EB.3.1 Test purpose

Same test purpose as in clause 6.3.5.3.1.

6.3.5EB.3.2 Test applicability

This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.

6.3.5EB.3.3 Minimum conformance requirement

Same minimum conformance requirements as in clause 6.3.5.3.3.

6.3.5EB.3.4 Test description
6.3.5EB.3.4.1 Initial conditions

Same initial conditions as in clause 6.3.5.3.4.1 with the following exceptions:

– Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.

6.3.5EB.3.4.2 Test procedure

Same test procedure as in clause 6.3.5.3.4.2.

6.3.5EB.3.4.3 Message contents

Same message contents as in clause 6.3.5.3.4.3.

6.3.5EB.3.5 Test requirements

Same test requirements as in clause 6.3.5.3.5.