6.3.5_1 Power Control for HPUE

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

Same text as in clause 6.3.5.

6.3.5_1.1 Power Control Absolute power tolerance for HPUE

6.3.5_1.1.1 Test purpose

Same test purpose as in clause 6.3.5.1.1.

6.3.5_1.1.2 Test applicability

This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.

6.3.5_1.1.3 Minimum conformance requirement

Same minimum conformance requirement as in clause 6.3.5.1.3 with the following exceptions:

– Instead of sub-clause 6.2.2 🡪 use sub-clause 6.2.2_1

The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.1.1.

6.3.5_1.1.4 Test description

Same test description as in clause 6.3.5.1.4 with the following exceptions:

– For test point 2, instead of Table 6.3.5.1.4.3-2 🡪 use Table 6.3.5_1.1.4.3-1 or 6.3.5_1.1.4.3-2

Table 6.3.5_1.1.4.3-1: UplinkPowerControlCommon: Test point 2 for Power Class 1

Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-25 UplinkPowerControlCommon-DEFAULT

Information Element

Value/remark

Comment

Condition

UplinkPowerControlCommon-DEFAULT ::= SEQUENCE {

p0-NominalPUSCH

-85

Test point 2 to verify a UE relative high initial power transmission

Table 6.3.5_1.1.4.3-2: UplinkPowerControlCommon: Test point 2 for Power Class 2

Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-25 UplinkPowerControlCommon-DEFAULT

Information Element

Value/remark

Comment

Condition

UplinkPowerControlCommon-DEFAULT ::= SEQUENCE {

p0-NominalPUSCH

-90

Test point 2 to verify a UE relative high initial power transmission

6.3.5_1.1.5 Test requirement

The requirement for the power measured in step (2) of the test procedure is not to exceed the values specified in Tables 6.3.5_1.1.5-1, 6.3.5_1.1.5-2, 6.3.5_1.1.5-3, and 6.3.5_1.1.5-4.

Table 6.3.5_1.1.5-1: Absolute power tolerance: test point 1 for Power Class 1

Channel bandwidth / expected output power (dBm)

5

MHz

10

MHz

Expected Measured power Normal conditions

-8.6 dBm

-5.6 dBm

Power tolerance

± 10.0dB

± 10.0dB

Expected Measured power Extreme conditions

-8.6 dBm

-5.6 dBm

Power tolerance

± 13.0dB

± 13.0dB

Note 1: The lower power limit shall not exceed the minimum output power requirements defined in sub-clause 6.3.2.3

Table 6.3.5_1.1.5-2: Absolute power tolerance: test point 1 for Power Class 2

Channel bandwidth / expected output power (dBm)

5 MHz

10 MHz

15 MHz

20 MHz

Expected Measured power Normal conditions

-8.6 dBm

-5.6 dBm

-3.9 dBm

-2.6 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

Expected Measured power Extreme conditions

-8.6 dBm

-5.6 dBm

-3.9 dBm

-2.6 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

Note 1: The lower power limit shall not exceed the minimum output power requirements defined in sub-clause 6.3.2.3

Table 6.3.5_1.1.5-3: Absolute power tolerance: test point 2 for Power Class 1

Channel bandwidth / expected output power (dBm)

5

MHz

10

MHz

Expected Measured power Normal conditions

11.4 dBm

14.4 dBm

Power tolerance

± 10.0dB

± 10.0dB

Expected Measured power Extreme conditions

11.4 dBm

14.4 dBm

Power tolerance

± 13.0dB

± 13.0dB

Note 1: The upper power limit shall not exceed the maximum output power requirements defined by the power class in sub-clause 6.2.2_1.3.

Table 6.3.5_1.1.5-4: Absolute power tolerance: test point 2 for Power Class 2

Channel bandwidth / expected output power (dBm)

5 MHz

10 MHz

15 MHz

20 MHz

Expected Measured power Normal conditions

6.4 dBm

9.4 dBm

11.2 dBm

12.4 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

± 10.0dB

± 10.4dB

Expected Measured power Extreme conditions

6.4 dBm

9.4 dBm

11.2 dBm

12.4 dBm

Power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

± 13.0dB

± 13.4dB

Note 1: The upper power limit shall not exceed the maximum output power requirements defined by the power class in sub-clause 6.2.2_1.3

6.3.5_1.2 Power Control Relative power tolerance for HPUE

6.3.5_1.2.1 Test purpose

Same test purpose as in clause 6.3.5.2.1.

6.3.5_1.2.2 Test applicability

This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.

6.3.5_1.2.3 Minimum conformance requirement

Same minimum conformance requirement as in clause 6.3.5.2.3 with the following exceptions

– Instead of clause 6.2.2.3 🡪 use sub-clause 6.2.2_1.3

The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.2.

6.3.5_1.2.4 Test description

Same test description as in clause 6.3.5.2.4 with the following exceptions:

– Power Class 1: In clause 6.3.5.2.4.2, test step 2.1, setting the UE PUSCH power at +26dBm +/-3.2dB instead of +18.0dBm +/-3.2dB

– Power Class 2: In clause 6.3.5.2.4.2, test step 2.1, setting the UE PUSCH power at +21dBm +/-3.2dB instead of +18.0dBm +/-3.2dB

6.3.5_1.2.5 Test requirement

Same test requirement as in clause 6.3.5.2.5.

6.3.5_1.3 Aggregate power control tolerance for HPUE

6.3.5_1.3.1 Test purpose

Same test purpose as in clause 6.3.5.3.1.

6.3.5_1.3.2 Test applicability

This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.

6.3.5_1.3.3 Minimum conformance requirement

Same minimum conformance requirement as in clause 6.3.5.3.3 with the following exception:

– Instead of sub-clause 6.2.2 🡪 use sub-clause 6.2.2_1

The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.3.1.

6.3.5_1.3.4 Test description

Same test description as in clause 6.3.5.3.4.

6.3.5_1.3.5 Test requirement

Same test requirement as in clause 6.3.5.3.5.