6.3.5_1 Power Control for HPUE
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
Same text as in clause 6.3.5.
6.3.5_1.1 Power Control Absolute power tolerance for HPUE
6.3.5_1.1.1 Test purpose
Same test purpose as in clause 6.3.5.1.1.
6.3.5_1.1.2 Test applicability
This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.
6.3.5_1.1.3 Minimum conformance requirement
Same minimum conformance requirement as in clause 6.3.5.1.3 with the following exceptions:
– Instead of sub-clause 6.2.2 🡪 use sub-clause 6.2.2_1
The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.1.1.
6.3.5_1.1.4 Test description
Same test description as in clause 6.3.5.1.4 with the following exceptions:
– For test point 2, instead of Table 6.3.5.1.4.3-2 🡪 use Table 6.3.5_1.1.4.3-1 or 6.3.5_1.1.4.3-2
Table 6.3.5_1.1.4.3-1: UplinkPowerControlCommon: Test point 2 for Power Class 1
Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-25 UplinkPowerControlCommon-DEFAULT |
|||
Information Element |
Value/remark |
Comment |
Condition |
UplinkPowerControlCommon-DEFAULT ::= SEQUENCE { p0-NominalPUSCH |
-85 |
Test point 2 to verify a UE relative high initial power transmission |
Table 6.3.5_1.1.4.3-2: UplinkPowerControlCommon: Test point 2 for Power Class 2
Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-25 UplinkPowerControlCommon-DEFAULT |
|||
Information Element |
Value/remark |
Comment |
Condition |
UplinkPowerControlCommon-DEFAULT ::= SEQUENCE { p0-NominalPUSCH |
-90 |
Test point 2 to verify a UE relative high initial power transmission |
6.3.5_1.1.5 Test requirement
The requirement for the power measured in step (2) of the test procedure is not to exceed the values specified in Tables 6.3.5_1.1.5-1, 6.3.5_1.1.5-2, 6.3.5_1.1.5-3, and 6.3.5_1.1.5-4.
Table 6.3.5_1.1.5-1: Absolute power tolerance: test point 1 for Power Class 1
Channel bandwidth / expected output power (dBm) |
||
5 MHz |
10 MHz |
|
Expected Measured power Normal conditions |
-8.6 dBm |
-5.6 dBm |
Power tolerance |
± 10.0dB |
± 10.0dB |
Expected Measured power Extreme conditions |
-8.6 dBm |
-5.6 dBm |
Power tolerance |
± 13.0dB |
± 13.0dB |
Note 1: The lower power limit shall not exceed the minimum output power requirements defined in sub-clause 6.3.2.3 |
Table 6.3.5_1.1.5-2: Absolute power tolerance: test point 1 for Power Class 2
Channel bandwidth / expected output power (dBm) |
||||
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Expected Measured power Normal conditions |
-8.6 dBm |
-5.6 dBm |
-3.9 dBm |
-2.6 dBm |
Power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
Expected Measured power Extreme conditions |
-8.6 dBm |
-5.6 dBm |
-3.9 dBm |
-2.6 dBm |
Power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
Note 1: The lower power limit shall not exceed the minimum output power requirements defined in sub-clause 6.3.2.3 |
Table 6.3.5_1.1.5-3: Absolute power tolerance: test point 2 for Power Class 1
Channel bandwidth / expected output power (dBm) |
||
5 MHz |
10 MHz |
|
Expected Measured power Normal conditions |
11.4 dBm |
14.4 dBm |
Power tolerance |
± 10.0dB |
± 10.0dB |
Expected Measured power Extreme conditions |
11.4 dBm |
14.4 dBm |
Power tolerance |
± 13.0dB |
± 13.0dB |
Note 1: The upper power limit shall not exceed the maximum output power requirements defined by the power class in sub-clause 6.2.2_1.3. |
Table 6.3.5_1.1.5-4: Absolute power tolerance: test point 2 for Power Class 2
Channel bandwidth / expected output power (dBm) |
||||
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Expected Measured power Normal conditions |
6.4 dBm |
9.4 dBm |
11.2 dBm |
12.4 dBm |
Power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
± 10.0dB ± 10.4dB |
Expected Measured power Extreme conditions |
6.4 dBm |
9.4 dBm |
11.2 dBm |
12.4 dBm |
Power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
± 13.0dB ± 13.4dB |
Note 1: The upper power limit shall not exceed the maximum output power requirements defined by the power class in sub-clause 6.2.2_1.3 |
6.3.5_1.2 Power Control Relative power tolerance for HPUE
6.3.5_1.2.1 Test purpose
Same test purpose as in clause 6.3.5.2.1.
6.3.5_1.2.2 Test applicability
This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.
6.3.5_1.2.3 Minimum conformance requirement
Same minimum conformance requirement as in clause 6.3.5.2.3 with the following exceptions
– Instead of clause 6.2.2.3 🡪 use sub-clause 6.2.2_1.3
The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.2.
6.3.5_1.2.4 Test description
Same test description as in clause 6.3.5.2.4 with the following exceptions:
– Power Class 1: In clause 6.3.5.2.4.2, test step 2.1, setting the UE PUSCH power at +26dBm +/-3.2dB instead of +18.0dBm +/-3.2dB
– Power Class 2: In clause 6.3.5.2.4.2, test step 2.1, setting the UE PUSCH power at +21dBm +/-3.2dB instead of +18.0dBm +/-3.2dB
6.3.5_1.2.5 Test requirement
Same test requirement as in clause 6.3.5.2.5.
6.3.5_1.3 Aggregate power control tolerance for HPUE
6.3.5_1.3.1 Test purpose
Same test purpose as in clause 6.3.5.3.1.
6.3.5_1.3.2 Test applicability
This test applies to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.
6.3.5_1.3.3 Minimum conformance requirement
Same minimum conformance requirement as in clause 6.3.5.3.3 with the following exception:
– Instead of sub-clause 6.2.2 🡪 use sub-clause 6.2.2_1
The normative reference for this requirement is TS 36.101 [2] clause 6.3.5.3.1.
6.3.5_1.3.4 Test description
Same test description as in clause 6.3.5.3.4.
6.3.5_1.3.5 Test requirement
Same test requirement as in clause 6.3.5.3.5.