6.3.4EC ON/OFF time mask for UE category M2
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.3.4EC.1 General ON/OFF time mask for UE category M2
6.3.4EC.1.1 Test purpose
Same test purpose as in clause 6.3.4.1.1.
6.3.4EC.1.2 Test applicability
This test case applies to all types of E-UTRA UE release 14 and forward of UE category M2.
6.3.4EC.1.3 Minimum conformance requirement
Same minimum conformance requirements as in clause 6.3.4.1.3.
6.3.4EC.1.4 Test description
6.3.4EC.1.4.1 Initial conditions
Same as in clause 6.3.4EA.1.4.1 with the following exceptions:
- Instead of Table 6.3.4EA.1.4.1-1 -> use Table 6.3.4EC.1.4.1-1
Table 6.3.4EC.1.4.1-1: Test Configuration Table
Initial Conditions |
||||||
Test Environment as specified in TS 36.508 [7] subclause 4.1 |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
|||||
Test Frequencies as specified in TS 36.508 [7] subclause 4.3.1 |
Low range, Mid range, High range |
|||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
5 MHz |
|||||
Test Parameters for Channel Bandwidths |
||||||
Downlink Configuration |
Uplink Configuration |
|||||
Ch BW |
N/A for General On/Off Time Mask test case |
Mod’n |
RB allocation |
|||
FDD and HD-FDD |
TDD |
Narrowband index1 |
||||
5MHz |
QPSK |
24 |
24 |
0 |
||
Note 1: Denotes the lowest narrowband index in the channel bandwidth where the wideband shall be placed. The allocation is contiguous, starting from the lowest narrowband index. Narrowband, Narrowband index and Wideband are defined in TS 36.211 [8], 5.2.4. |
6.3.4EC.1.4.2 Test procedure
Same as in clause 6.3.4EA.1.4.2 with the following exceptions:
- Instead of Table 6.3.4EA.1.4.1-1 -> use Table 6.3.4EC.1.4.1-1
6.3.4EC.1.4.3 Message contents
Same as in clause 6.3.4EA.1.4.3.
6.3.4EC.1.5 Test requirement
Same as in clause 6.3.4EA.1.5.
6.3.4EC.2 PRACH and SRS ON/OFF time mask for UE category M2
6.3.4EC.2.1 PRACH time mask for UE category M2
6.3.4EC.2.1.1 Test purpose
Same test purpose as in clause 6.3.4.2.1.1.
6.3.4EC.2.1.2 Test applicability
This test case applies to all types of E-UTRA UE release 14 and forward of UE category M2.
6.3.4EC.2.1.3 Minimum conformance requirement
Same minimum conformance requirements as in clause 6.3.4.2.1.3.
6.3.4EC.2.1.4 Test description
6.3.4EC.2.1.4.1 Initial conditions
Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.
The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA operating bands specified in clause 5.2E. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 6.3.4EC.2.1.4.1-1. The details of the uplink and downlink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3.
Table 6.3.4EC.2.1.4.1-1: Test Configuration Table
Initial Conditions |
||
Test Environment (as specified in TS 36.508 [7] subclause 4.1) |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
|
Test Frequencies (as specified in TS 36.508 [7] subclause 4.3.1) |
Mid range |
|
Test Channel Bandwidths (as specified in TS 36.508 [7] subclause 4.3.1) |
5 MHz, Highest |
|
PRACH preamble format |
FDD and HD-FDD |
TDD |
PRACH Configuration Index |
3 |
51 |
1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
2. The parameter settings for the cell are set up according to TS 36.508 [7] subclause 4.4.3.
3. Downlink signals are initially set up according to Annex C.0, C.1, and C.3.0, and uplink signals according to Annex H.1 and H.3.0.
4. Propagation conditions are set according to Annex B.0.
5. Ensure the UE is in State 3A-RF-CE according to TS 36.508 [7] clause 5.2A.2AA. Message contents are defined in clause 6.3.4EC.2.1.4.3.
6.3.4EC.2.1.4.2 Test procedure
Same test procedure as in clause 6.3.4EA.2.1.4.2.
6.3.4EC.2.1.4.3 Message contents
Same message contents as in clause 6.3.4EA.2.1.4.3.
6.3.4EC.2.1.5 Test requirement
The requirement for the power measured in steps (3), (4) and (5) of the test procedure shall not exceed the values specified in Table 6.3.4.2.1.5-1.
Table 6.3.4.2.1.5-1: PRACH time mask
Channel bandwidth / Output Power [dBm] / measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Transmit OFF power |
For carrier frequency f ≤ 3.0GHz: ≤ -48.5 dBm For carrier frequency 3.0GHz < f ≤ 4.2GHz: ≤ -48.2 dBm |
|||||
Transmission OFF Measurement bandwidth |
N/A |
N/A |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |
Expected PRACH Transmission ON Measured power |
N/A |
N/A |
-1 dBm |
-1 dBm |
-1 dBm |
-1 dBm |
ON power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
N/A |
N/A |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |
6.3.4EC.2.2 SRS time mask for UE category M2
6.3.4EC.2.2.1 Test purpose
Same test purpose as in clause 6.3.4.2.2.1.
6.3.4EC.2.2.2 Test applicability
This test case applies to all types of E-UTRA UE release 14 and forward of UE category M2.
6.3.4EC.2.2.3 Minimum conformance requirement
Same minimum conformance requirements as in clause 6.3.4.2.2.3.
6.3.4EC.2.2.4 Test description
6.3.4EC.2.2.4.1 Initial conditions
Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.
The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA operating bands specified in clause 5.2E. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 6.3.4EC.2.2.4.1-1. The details of the uplink and downlink reference measurement channels (RMCs) are specified in Annexes A.2 and A.3.
Table 6.3.4EC.2.2.4.1-1: Test Configuration Table
Initial Conditions |
||
Test Environment (as specified in TS 36.508 [7] subclause 4.1) |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
|
Test Frequencies (as specified in TS 36.508 [7] subclause 4.3.1) |
Mid range |
|
Test Channel Bandwidths (as specified in TS 36.508 [7] subclause 4.3.1) |
5MHz, Highest |
|
SRS configuration |
FDD and HD-FDD |
TDD |
srs-BandwidthConfig |
bw7 |
bw2 |
srs-SubframeConfig |
sc3 |
sc0 |
ackNackSRS-SimultaneousTransmission |
FALSE |
FALSE |
srsMaxUpPts |
N/A |
N/A |
srs-Bandwidth |
bw3 |
bw3 |
srs-HoppingBandwidth |
hbw3 |
hbw0 |
freqDomainPosition |
0 |
0 |
Duration |
TRUE |
TRUE |
srs-ConfigIndex |
7 |
0 |
transmissionComb |
0 |
0 |
cyclicShift |
cs0 |
cs0 |
1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
2. The parameter settings for the cell are set up according to TS 36.508 [7] subclause 4.4.3.
3. Downlink signals are initially set up according to Annex C.0, C.1, and C.3.0, and uplink signals according to Annex H.1 and H.3.0.
4. Propagation conditions are set according to Annex B.0.
5. Ensure the UE is in State 3A-RF-CE according to TS 36.508 [7] clause 5.2A.2AA. Message contents are defined in clause 6.3.4EC.2.2.4.3. Note that MPDCCH DCI format 6-0A sent after resetting uplink power with RRC Connection Reconfiguration, should have TPC command 0dB.
6.3.4EC.2.2.4.2 Test procedure
Same test procedure as in clause 6.3.4EA.2.2.4.2.
6.3.4EC.2.2.4.3 Message contents
Same message contents as in clause 6.3.4EA.2.2.4.3.
6.3.4EC.2.2.5 Test requirement
The requirement for the power measured in steps (1), (2) and (3) of the test procedure shall not exceed the values specified in Table 6.3.4EC.2.2.5-1.
Table 6.3.4EC.2.2.5-1: SRS time mask
Channel bandwidth / Output Power [dBm] / measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Transmit OFF power |
For carrier frequency f ≤ 3.0GHz: ≤ -48.5 dBm For carrier frequency 3.0GHz < f ≤ 4.2GHz: ≤ -48.2 dBm |
|||||
Transmission OFF Measurement bandwidth |
N/A |
N/A |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |
Expected SRS Transmission ON Measured power |
N/A |
N/A |
-2.6 dBm |
-2.6 dBm |
-2.6 dBm |
-2.6 dBm |
ON power tolerance f ≤ 3.0GHz 3.0GHz < f ≤ 4.2GHz |
N/A |
N/A |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |
± 7.5dB ± 7.8dB |