6.3.4B ON/OFF time mask for UL-MIMO

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

6.3.4B.1 General ON/OFF time mask for UL-MIMO

Editor’s note: The measurement period in the minimum requirement is defined to be 1 subframe (14 symbols). Due to practical reasons the TDD measurement period for off power prior the PUSCH is 10 symbols. It is FFS, if this deviation is acceptable.

Editor’s notes: The following items are missing or incomplete:

– The initial conditions and test procedure are subject to further investigation

6.3.4B.1.1 Test purpose

To verify that the general ON/OFF time mask for UL-MIMO meets the requirements given in 6.3.4B.1.5.

The time mask for transmit ON/OFF defines the ramping time allowed for each transmit antenna of UE between transmit OFF power and transmit ON power.

Transmission of the wrong power increases interference to other channels, or increases transmission errors in the uplink channel.

6.3.4B.1.2 Test applicability

This test applies to all types of E-UTRA UE release 10 and forward that support UL-MIMO

6.3.4B.1.3 Minimum conformance requirement

For UE with multiple transmit antenna connectors, the ON/OFF time mask requirements in subclause 6.3.4.1.3 apply to each transmit antenna connector.

For UE with two transmit antenna connectors in closed-loop spatial multiplexing scheme, the general ON/OFF time mask requirements specified in subclause 6.3.4.1.3 apply to each transmit antenna connector with the UL-MIMO configurations specified in Table 6.2.2B.3-2.

The normative reference for this requirement is TS 36.101 [2] clause 6.3.4B

6.3.4B.1.4 Test description

6.3.4B.1.4.1 Initial conditions

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA operating bands specified in table 5.4.2.1-1. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 6.3.4B.1.4.1-1. The details of the uplink reference measurement channels (RMCs) are specified in Annexes A.2. Configurations of PDSCH and PDCCH before measurement are specified in Annex C.2

Table 6.3.4B.1.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in

TS 36.508 [7] subclause 4.1

Normal, TL/VL, TL/VH, TH/VL, TH/VH

Test Frequencies as specified in

TS 36.508 [7] subclause 4.3.1

Low range, Mid range, High range

Test Channel Bandwidths as specified in

TS 36.508 [7] subclause 4.3.1

Lowest, 5MHz, Highest

Test Parameters for Channel Bandwidths

Downlink Configuration

Uplink Configuration

Ch BW

N/A for General On/Off Time Mask test case

Mod’n

RB allocation

FDD

TDD

1.4MHz

QPSK

6

6

3MHz

QPSK

15

15

5MHz

QPSK

25

25

10MHz

QPSK

50

50

15MHz

QPSK

75

75

20MHz

QPSK

100

100

Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1.

1. Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A, Figure A.28.

2. The parameter settings for the cell are set up according to TS 36.508 [7] subclause 4.4.3.

3. Downlink signals are initially set up according to Annex C.0, C.1 and C.3.0, and uplink signals according to Annex H.1 and H.3.0.

4. The UL and DL Reference Measurement channels are set according to Table 6.3.4B.1.4.1-1.

5. Propagation conditions are set according to Annex B.0.

6. Ensure the UE is in State 3A-RF according to TS 36.508 [7] clause 5.2A.2. Message contents are defined in clause 6.3.4B.1.4.3. Note that PDCCH DCI format 4 sent after resetting uplink power with RRC Connection Reconfiguration, should have TPC command 0dB.

6.3.4B.1.4.2 Test procedure

1. SS sends uplink scheduling information via PDCCH with DCI format 4 and TPC command 0dB for C_RNTI to schedule the UL RMC according to Table 6.3.4B.1.4.1-1. Since the UE has no payload and no loopback data to send the UE sends uplink MAC padding bits on the UL RMC. The UL assignment is such that the UE transmits on UL sub-frame 2 of every radio frame.

2. For FDD: Measure the UE transmission OFF power during the sub-frame prior to the PUSCH subframe. For TDD: Measure the UE transmission OFF power during the 10 SCFDMA symbols prior to the PUSCH subframe.

3. Measure the output power of the UE PUSCH transmission during one sub-frame, excluding a transient period of 20 µs at the beginning of the subframe.

4. Measure the UE transmission OFF power during one sub-frame following the PUSCH subframe, excluding a transient period of 20 µs at the beginning of the subframe.

5. Repeat step 2) until 4) for each of transmit antenna of the UE.

6.3.4B.1.4.3 Message contents

Message contents are according to TS 36.508 [7] clause 4.6 with the following exceptions:

Table 6.3.4B.1.4.3-1: UplinkPowerControlCommon: Test point 1

Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-25 UplinkPowerControlCommon-DEFAULT

Information Element

Value/remark

Comment

Condition

UplinkPowerControlCommon-DEFAULT ::= SEQUENCE {

p0-NominalPUSCH

-105

Test point 1 to verify a UE relative low initial power transmission

Table 6.3.4B.1.4.3-2: PhysicalConfigDedicated

Derivation Path: TS 36.508 [7] clause 5.5.1.2, Table 5.5.1.2.1 PhysicalConfigDedicated-DEFAULT

Information Element

Value/remark

Comment

Condition

PhysicalConfigDedicated-DEFAULT ::= SEQUENCE {

UplinkPowerControlDedicated

UplinkPowerControlDedicated-DEFAULT

See clause 4.6.3

SRB1

UplinkPowerControlDedicated-DEFAULT

See clause 4.6.3

RBC

Table 6.3.4B.1.4.3-3: UplinkPowerControlDedicated

Derivation Path: TS 36.508 [7] clause 4.6.3, Table 4.6.3-26 UplinkPowerControlDedicated-DEFAULT

Information Element

Value/remark

Comment

Condition

UplinkPowerControlDedicated-DEFAULT ::= SEQUENCE {

p0-UE-PUSCH

1

SRB1

0

RBC

}

Table 6.3.4B.1.3-4: TDD-Config-DEFAULT: On/OFF time mask measurement

Derivation Path: 36.508 clause 5.3.1 Table 5.3.1-1 (SystemInformationBlockType1)

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

subframeAssignment

sa1

specialSubframePatterns

ssp5

To enable two symbol UpPTS, and to have 9 symbols GP.

}

6.3.4B.1.5 Test requirement

The requirement for the power measured in steps (2), (3) and (4) of the test procedure shall not exceed the values specified in Table 6.3.4B.1.5-1.

Table 6.3.4B.1.5-1: General ON/OFF time mask

Channel bandwidth / minimum output power / measurement bandwidth

1.4

MHz

3.0

MHz

5

MHz

10

MHz

15

MHz

20

MHz

Transmit OFF power

For carrier frequency f ≤ 3.0GHz: ≤ -48.5 dBm

For carrier frequency 3.0GHz < f ≤ 4.2GHz: ≤ -48.2 dBm

Transmission OFF Measurement bandwidth

1.08 MHz

2.7 MHz

4.5 MHz

9.0 MHz

13.5 MHz

18 MHz

Expected Transmission ON Measured power

-14.8 dBm

-10.8 dBm

-8.6 dBm

-5.6 dBm

-3.9 dBm

-2.6 dBm

ON power tolerance

f ≤ 3.0GHz

3.0GHz < f ≤ 4.2GHz

7.5 dB

±7.8dB

7.5 dB

±7.8dB

7.5dB

±7.8dB

7.5dB

±7.8dB

7.5dB

±7.8dB

7.5dB

±7.8dB