6.3.2EB Minimum Output Power for UE category 1bis
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.3.2EB.1 Test purpose
Same test purpose as in clause 6.3.2.1.
6.3.2EB.2 Test applicability
This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.
6.3.2EB.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 6.3.2.3.
6.3.2EB.4 Test description
6.3.2EB.4.1 Initial conditions
Same initial conditions as in clause 6.3.2.4.1 with following exceptions:
– Connect SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
6.3.2EB.4.2 Test procedure
Same test procedure as in clause 6.3.2.4.2.
6.3.2EB.4.3 Message contents
Message contents are according to TS 36.508 [7] subclause 4.6.
6.3.2EB.5 Test requirement
The minimum output power measured shall not exceed the values specified in Table 6.3.2EB.5-1.
Table 6.3.2EB.5-1: Minimum output power
Channel bandwidth / minimum output power / measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Minimum output power |
For carrier frequency f ≤ 3.0GHz: ≤ -39 dBm For carrier frequency 3.0GHz < f ≤ 4.2GHz: ≤ -38.7 dBm |
|||||
Measurement bandwidth (Note 1) |
1.08 MHz |
2.7 MHz |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |
Note 1: Different implementations such as FFT or spectrum analyzer approach are allowed. For spectrum analyzer approach the measurement bandwidth is defined as an equivalent noise bandwidth. |