6.2.5FA Configured UE transmitted Output Power for UE category NB1 and NB2/Power Class 6
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.5FA.1 Test purpose
Same test purpose as in clause 6.2.5F.1.
6.2.5FA.2 Test applicability
This test case applies to all types of NB-IoT FDD Power Class 6 UE release 14 and forward of category NB1 and NB2.
This test case applies to all types of NB-IoT TDD Power Class 6 UE release 15 and forward of category NB1 and NB2.
6.2.5FA.3 Minimum conformance requirements
For each slot i the NB IoT UE is allowed to set its configured maximum output power PCMAX,c. The configured maximum output power PCMAX,c is set within the following bounds:
PCMAX_L,c ≤ PCMAX,c ≤ PCMAX_H,c
Where
– PCMAX_L,c = MIN { PEMAX,c , PPowerClass – MPRc – A-MPRc}
– PCMAX_H,c = MIN { PEMAX,c, PPowerClass}
– PEMAX,c is the value given to IE P-Max, defined in [7]
– PPowerClass is the maximum category NB1 and NB2 UE power specified in Table 6.2.2FA.3-1 without taking into account the associated tolerance
– MPRc is specified in subclause 6.2.3FA
A-MPRc = 0dB unless otherwise stated.
The measurement period for PUMAX,c is at least one sub-frame (1ms) for 15 KHz channel spacing, and at least a 2ms slot (excluding the 2304Ts gap when UE is not transmitting) respectively for the 3.75 KHz channel spacing. The measured maximum output power PUMAX,c shall be within the following bounds:
PCMAX_L,c – T(PCMAX_L,c) ≤ PUMAX,c ≤ PCMAX_H,c + T(PCMAX_H,c)
Where T(PCMAX) is defined by the tolerance table below and applies to PCMAX_L,c and PCMAX_H,c separately.
Table 6.2.5FA.3-1: PCMAX tolerance for power class 6
PCMAX,c |
Tolerance T(PCMAX,c) |
13 ≤ PCMAX,c ≤ 14 |
2.5 |
12 ≤ PCMAX,c < 13 |
3.5 |
11 ≤ PCMAX,c < 12 |
4.0 |
8 ≤ PCMAX,c < 11 |
5.0 |
5 ≤ PCMAX,c < 8 |
6.0 |
-40 ≤ PCMAX,c < 5 |
7.0 |
The normative reference for this requirement is TS 36.101 [2] clause 6.2.5F.
6.2.5FA.4 Test description
6.2.5FA.4.1 Initial conditions
Same initial conditions as in clause 6.2.5F.4.1.
6.2.5FA.4.2 Test procedure
Same test procedure as in clause 6.2.5F.4.2.
6.2.5FA.4.3 Message contents
Message contents are according to TS 36.508 [7] subclause 8.1.6 with the following exceptions:
Table 6.2.5FA.4.3-1: SystemInformationBlockType1: Test point 1 for power class 6
Derivation Path: TS 36.508 [7] clause 8.1.4, Table 8.1.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
-10 |
Table 6.2.5FA.4.3-2: SystemInformationBlockType1: Test point 2 for power class 6
Derivation Path: TS 36.508 [7] clause 8.1.4, Table 8.1.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
6 |
Table 6.2.5FA.4.3-3: SystemInformationBlockType1: Test point 3 for power class 6
Derivation Path: TS 36.508 [7] clause 8.1.4, Table 8.1.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
9 |
6.2.5FA.5 Test requirement
The maximum output power measured shall not exceed the values specified in Table 6.2.5FA.5-1.Table 6.2.5FA.5-1: PCMAX configured UE output power for power class 6
maximum output power |
|
Measured UE output power test point 1 |
For carrier frequency f ≤ 3.0GHz: -10 dBm ± 7.7 |
Measured UE output power test point 2 |
For carrier frequency f ≤ 3.0GHz: 6 dBm ± 6.7 |
Measured UE output power test point 3 |
For carrier frequency f ≤ 3.0GHz: 9 dBm ± 5.7 |