6.2.5EB Configured UE transmitted Power for UE category 1bis
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.5EB.1 Test purpose
Same test purpose as in clause 6.2.5.1.
6.2.5EB.2 Test applicability
This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.
6.2.5EB.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 6.2.5.3
6.2.5EB.4 Test description
6.2.5EB.4.1 Initial conditions
Same initial conditions as in clause 6.2.5.4.1 with following exception:
– Connect SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
6.2.5EB.4.2 Test procedure
Same test procedure as in clause 6.2.5.4.2.
6.2.5EB.4.3 Message contents
Same message contents as in clause 6.2.5.4.3.
6.2.5EB.5 Test requirement
The maximum output power measured shall not exceed the values specified in Table 6.2.5EB.5-1.
Table 6.2.5EB.5-1: PCMAX configured UE output power
Channel bandwidth / maximum output power |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Measured UE output power test point 1 |
For carrier frequency f ≤ 3.0GHz: -10 dBm ± 7.7 For carrier frequency 3.0GHz < f ≤ 4.2GHz: -10 dBm ± 8.0 |
|||||
Measured UE output power test point 2 |
For carrier frequency f ≤ 3.0GHz: 10 dBm ± 6.7 For carrier frequency 3.0GHz < f ≤ 4.2GHz: 10 dBm ± 7.0 |
|||||
Measured UE output power test point 3 |
For carrier frequency f ≤ 3.0GHz: 15 dBm ± 5.7 For carrier frequency 3.0GHz < f ≤ 4.2GHz: 15 dBm ± 6.0 |
|||||
Note: In addition note 2 in Table 6.2.2.3-1 shall apply to the tolerances. |