6.2.5EB Configured UE transmitted Power for UE category 1bis

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

6.2.5EB.1 Test purpose

Same test purpose as in clause 6.2.5.1.

6.2.5EB.2 Test applicability

This test applies to all types of E-UTRA UE release 13 and forward of category 1bis.

6.2.5EB.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.2.5.3

6.2.5EB.4 Test description

6.2.5EB.4.1 Initial conditions

Same initial conditions as in clause 6.2.5.4.1 with following exception:

– Connect SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.

6.2.5EB.4.2 Test procedure

Same test procedure as in clause 6.2.5.4.2.

6.2.5EB.4.3 Message contents

Same message contents as in clause 6.2.5.4.3.

6.2.5EB.5 Test requirement

The maximum output power measured shall not exceed the values specified in Table 6.2.5EB.5-1.

Table 6.2.5EB.5-1: PCMAX configured UE output power

Channel bandwidth / maximum output power

1.4

MHz

3.0

MHz

5

MHz

10

MHz

15

MHz

20

MHz

Measured UE output power test point 1

For carrier frequency f ≤ 3.0GHz: -10 dBm ± 7.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: -10 dBm ± 8.0

Measured UE output power test point 2

For carrier frequency f ≤ 3.0GHz: 10 dBm ± 6.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: 10 dBm ± 7.0

Measured UE output power test point 3

For carrier frequency f ≤ 3.0GHz: 15 dBm ± 5.7

For carrier frequency 3.0GHz < f ≤ 4.2GHz: 15 dBm ± 6.0

Note: In addition note 2 in Table 6.2.2.3-1 shall apply to the tolerances.