6.2.5_1 Configured UE transmitted Output Power for HPUE

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

6.2.5_1.1 Test purpose

To verify the UE does not exceed the minimum between the PEMAX maximum allowed UL TX Power signalled by the E-UTRAN and the PPowerClass maximum UE power the UE power class.

Additionally, for power class 2 UE in band 41, to verify that PCMAX,c is reduced when the uplink/downlink configuration is 0 or 6 in the cell.

6.2.5_1.2 Test applicability

This test applies to all types of E-UTRA power Class 1 or power Class 2 UE release 10 and forward.

6.2.5_1.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.2.5.3 with the following exceptions:

– Instead of Table 6.2.2.3-1 🡪 use Table 6.2.2_1.3-1

– Instead of Section 6.2.3 🡪 use Section 6.2.3_1

– Instead of Section 6.2.4 🡪 use Section 6.2.4_1

The normative reference for this requirement is TS 36.101 [2] clause 6.2.5.

6.2.5_1.4 Test description

6.2.5_1.4.1 Initial conditions

Same initial conditions as in clause 6.2.5.4.1 with the following exceptions

– Instead of clause 6.2.5.4.3 🡪 use clause 6.2.5_1.4.3

– Instead of table 6.2.5.4.1-1 🡪 use table 6.2.5_1.4.1-1

Table 6.2.5_1.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in

TS 36.508 [7] subclause 4.1

Normal, TL/VL, TL/VH, TH/VL, TH/VH

Test Frequencies as specified in

TS 36.508 [7] subclause 4.3.1

Mid range

Test Channel Bandwidths as specified in

TS 36.508 [7] subclause 4.3.1

Lowest, 5MHz, Highest

Test Parameters for Channel Bandwidths

Downlink Configuration

Uplink Configuration

Ch BW

N/A for Configured UE transmitted Output Power test case

Mod’n

RB allocation

FDD

TDD

1.4MHz

QPSK

5

5

3MHz

QPSK

4

4

5MHz

QPSK

8

8

10MHz

QPSK

12

12

15MHz

QPSK

16

16

20MHz

QPSK

18

18

Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1.

Note 2: For the uplink RB allocation the RBstart shall be RB #0.

Note 3: For power class 2 operation in band 41, RMC with UL-DL config 1 is used in test points 1 to 4 and RMC with UL-DL config 0 is used in test point 5.

6.2.5_1.4.2 Test procedure

Same test procedure as in clause 6.2.5.4.2 with the following exceptions:

– Instead of Table 6.2.5.5-1 🡪 use Tables 6.2.5_1.5-1 and 6.2.5_1.5-2

6.2.5_1.4.3 Message contents

Same message contents as in clause 6.2.5.4.3 with the following additional test point:

Table 6.2.5_1.4.3-1: SystemInformationBlockType1: Test point 4 for Power class 1

Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1

Information Element

Value/remark

Comment

Condition

p-Max

25

Table 6.2.5_1.4.3-2: SystemInformationBlockType1: Test point 4 for Power class 2

Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1

Information Element

Value/remark

Comment

Condition

p-Max

21

Table 6.2.5_1.4.3-3: SystemInformationBlockType1: Test point 5

Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1

Information Element

Value/remark

Comment

Condition

p-Max

26

Table 6.2.5_1.4.3-4: TDD-Config-DEFAULT: Test point 5

Derivation Path: TS 36.508 [7] clause 5.3.1, Table 5.3.1-1: TDD-Config-DEFAULT

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

subframeAssignment

sa0

To enable PC3 fallback operation

specialSubframePatterns

ssp4

}

6.2.5_1.5 Test requirement

The maximum output power measured shall not exceed the values specified in Table 6.2.5_1.5-1 and Table 6.2.5_1.5-2.

Table 6.2.5_1.5-1: PCMAX configured HPUE output power for Power class 1

Channel bandwidth / maximum output power

5MHz

10MHz

Measured UE output power test point 1

-10 dBm ± 7.7

Measured UE output power test point 2

10 dBm ± 6.7

Measured UE output power test point 3

15 dBm ± 5.7

Measured UE output power test point 4

25dBm ± 2.7

Table 6.2.5_1.5-1a: PCMAX configured HPUE output power for Power class 1 from Release 11 and forward for the band with lower tolerance, E-UTRA bands ≤ 3GHz

Channel bandwidth / maximum output power

5MHz

10MHz

Measured UE output power test point 1

-10 dBm ± 7.7

Measured UE output power test point 2

10 dBm ± 6.7

Measured UE output power test point 3

15 dBm ± 5.7

Measured UE output power test point 4

25dBm + 2.7/-3.7

Table 6.2.5_1.5-2: PCMAX configured HPUE output power for Power class 2

Channel bandwidth / maximum output power

5MHz

20MHz

Measured UE output power test point 1

-10 dBm ± 7.7

Measured UE output power test point 2

10 dBm ± 6.7

Measured UE output power test point 3

15 dBm ± 5.7

Measured UE output power test point 4

21 dBm ±2.7

Measured UE output power test point 5 (Note 1)

23 dBm ± 2.7

Note 1: Only applicable to power class 2 capable UE operating on Band 41with UL-DL config 0 or 6.

Table 6.2.5_1.5-2a: PCMAX configured HPUE output power for Power class 2 from Release 11 and forward for the band with lower tolerance, 3GHz < E-UTRA bands ≤ 4.2GHz

Channel bandwidth / maximum output power

5MHz

20MHz

Measured UE output power test point 1

-10 dBm ± 8

Measured UE output power test point 2

10 dBm ± 7

Measured UE output power test point 3

15 dBm ± 6

Measured UE output power test point 4

21 dBm +3/-4