6.2.5_1 Configured UE transmitted Output Power for HPUE
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.5_1.1 Test purpose
To verify the UE does not exceed the minimum between the PEMAX maximum allowed UL TX Power signalled by the E-UTRAN and the PPowerClass maximum UE power the UE power class.
Additionally, for power class 2 UE in band 41, to verify that PCMAX,c is reduced when the uplink/downlink configuration is 0 or 6 in the cell.
6.2.5_1.2 Test applicability
This test applies to all types of E-UTRA power Class 1 or power Class 2 UE release 10 and forward.
6.2.5_1.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 6.2.5.3 with the following exceptions:
– Instead of Table 6.2.2.3-1 🡪 use Table 6.2.2_1.3-1
– Instead of Section 6.2.3 🡪 use Section 6.2.3_1
– Instead of Section 6.2.4 🡪 use Section 6.2.4_1
The normative reference for this requirement is TS 36.101 [2] clause 6.2.5.
6.2.5_1.4 Test description
6.2.5_1.4.1 Initial conditions
Same initial conditions as in clause 6.2.5.4.1 with the following exceptions
– Instead of clause 6.2.5.4.3 🡪 use clause 6.2.5_1.4.3
– Instead of table 6.2.5.4.1-1 🡪 use table 6.2.5_1.4.1-1
Table 6.2.5_1.4.1-1: Test Configuration Table
Initial Conditions |
|||||
Test Environment as specified in TS 36.508 [7] subclause 4.1 |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
||||
Test Frequencies as specified in TS 36.508 [7] subclause 4.3.1 |
Mid range |
||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
Lowest, 5MHz, Highest |
||||
Test Parameters for Channel Bandwidths |
|||||
Downlink Configuration |
Uplink Configuration |
||||
Ch BW |
N/A for Configured UE transmitted Output Power test case |
Mod’n |
RB allocation |
||
FDD |
TDD |
||||
1.4MHz |
QPSK |
5 |
5 |
||
3MHz |
QPSK |
4 |
4 |
||
5MHz |
QPSK |
8 |
8 |
||
10MHz |
QPSK |
12 |
12 |
||
15MHz |
QPSK |
16 |
16 |
||
20MHz |
QPSK |
18 |
18 |
||
Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1. Note 2: For the uplink RB allocation the RBstart shall be RB #0. Note 3: For power class 2 operation in band 41, RMC with UL-DL config 1 is used in test points 1 to 4 and RMC with UL-DL config 0 is used in test point 5. |
6.2.5_1.4.2 Test procedure
Same test procedure as in clause 6.2.5.4.2 with the following exceptions:
– Instead of Table 6.2.5.5-1 🡪 use Tables 6.2.5_1.5-1 and 6.2.5_1.5-2
6.2.5_1.4.3 Message contents
Same message contents as in clause 6.2.5.4.3 with the following additional test point:
Table 6.2.5_1.4.3-1: SystemInformationBlockType1: Test point 4 for Power class 1
Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
25 |
Table 6.2.5_1.4.3-2: SystemInformationBlockType1: Test point 4 for Power class 2
Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
21 |
Table 6.2.5_1.4.3-3: SystemInformationBlockType1: Test point 5
Derivation Path: TS 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-3 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
26 |
Table 6.2.5_1.4.3-4: TDD-Config-DEFAULT: Test point 5
Derivation Path: TS 36.508 [7] clause 5.3.1, Table 5.3.1-1: TDD-Config-DEFAULT |
|||
Information Element |
Value/remark |
Comment |
Condition |
TDD-Config-DEFAULT ::= SEQUENCE { |
|||
subframeAssignment |
sa0 |
To enable PC3 fallback operation |
|
specialSubframePatterns |
ssp4 |
||
} |
6.2.5_1.5 Test requirement
The maximum output power measured shall not exceed the values specified in Table 6.2.5_1.5-1 and Table 6.2.5_1.5-2.
Table 6.2.5_1.5-1: PCMAX configured HPUE output power for Power class 1
Channel bandwidth / maximum output power |
||
5MHz |
10MHz |
|
Measured UE output power test point 1 |
-10 dBm ± 7.7 |
|
Measured UE output power test point 2 |
10 dBm ± 6.7 |
|
Measured UE output power test point 3 |
15 dBm ± 5.7 |
|
Measured UE output power test point 4 |
25dBm ± 2.7 |
Table 6.2.5_1.5-1a: PCMAX configured HPUE output power for Power class 1 from Release 11 and forward for the band with lower tolerance, E-UTRA bands ≤ 3GHz
Channel bandwidth / maximum output power |
||
5MHz |
10MHz |
|
Measured UE output power test point 1 |
-10 dBm ± 7.7 |
|
Measured UE output power test point 2 |
10 dBm ± 6.7 |
|
Measured UE output power test point 3 |
15 dBm ± 5.7 |
|
Measured UE output power test point 4 |
25dBm + 2.7/-3.7 |
Table 6.2.5_1.5-2: PCMAX configured HPUE output power for Power class 2
Channel bandwidth / maximum output power |
||
5MHz |
20MHz |
|
Measured UE output power test point 1 |
-10 dBm ± 7.7 |
|
Measured UE output power test point 2 |
10 dBm ± 6.7 |
|
Measured UE output power test point 3 |
15 dBm ± 5.7 |
|
Measured UE output power test point 4 |
21 dBm ±2.7 |
|
Measured UE output power test point 5 (Note 1) |
23 dBm ± 2.7 |
|
Note 1: Only applicable to power class 2 capable UE operating on Band 41with UL-DL config 0 or 6. |
Table 6.2.5_1.5-2a: PCMAX configured HPUE output power for Power class 2 from Release 11 and forward for the band with lower tolerance, 3GHz < E-UTRA bands ≤ 4.2GHz
Channel bandwidth / maximum output power |
||
5MHz |
20MHz |
|
Measured UE output power test point 1 |
-10 dBm ± 8 |
|
Measured UE output power test point 2 |
10 dBm ± 7 |
|
Measured UE output power test point 3 |
15 dBm ± 6 |
|
Measured UE output power test point 4 |
21 dBm +3/-4 |