6.2.4EB Additional Maximum Power Reduction (A-MPR) for UE category 1bis
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.4EB.1 Test purpose
Same test purpose as in clause 6.2.4.1.
6.2.4EB.2 Test applicability
The requirements of this test apply in test case 6.6.2.2EB Additional Spectrum Emission Mask for network signalled values NS_03, NS_04, NS_06 and NS_07 to all types of E-UTRA UE release 13 and forward of UE category 1bis.
The requirements of this test apply in test case 6.6.3EB.3 Additional Spurious Emissions for network signalled values NS_04, NS_05, NS_07, NS_12, NS_13, NS_14, NS_15, NS_17 and NS_18 to all types of E-UTRA UE release 13 and forward of UE category 1bis.
NOTE: As a result TC 6.2.4EB has not been included in the test case applicability table 4.1-1, TS 36.521-2. This does not preclude the test from being used for R&D or other purposes if deemed useful.
6.2.4EB.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 6.2.4.3.
6.2.4EB.4 Test description
6.2.4EB.4.1 Initial conditions
Same initial conditions as in clause 6.2.3.4.1 with the following exceptions:
– Connect the SS to the UE antenna connectors as shown in TS 36.508[7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
6.2.4EB.4.2 Test procedure
Same test procedure as in clause 6.2.2.4.2.
6.2.4EB.4.3 Message contents
Same message contents as in clause 6.2.2.4.3.
6.2.4EB.5 Test requirement
The maximum output power, derived in step 2 of clause 6.2.3EB.4.2, shall be within the range prescribed by the nominal maximum output power and tolerance in Table 6.2.3EB.5-1.
Table 6.2.3EB.5-1: UE Power Class test requirements
E-UTRA Band |
Class 1 (dBm) |
Tol. (Db) |
Class 2 (dBm) |
Tol. (dB) |
Class 3 (dBm) |
QPSK partial RB allocation Tol. (dB)) |
QPSK full RB allocation Tol. (dB)) |
16QAM partial RB allocation Tol. (dB) |
16QAM full RB allocation Tol. (dB) |
1 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
2 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
3 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
4 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
5 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
7 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
8 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
12 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
13 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
18 |
23 |
±2.73 |
+2.7 / 3 -3.7 |
+2.7 / 3 -3.7 |
+2.7 / 3 -4.7 |
||||
20 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
26 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
28 |
23 |
+2.7/-3.2 |
+2.7/-4.2 |
+2.7/-4.2 |
+2.7/-5.2 |
||||
31 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
39 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
41 |
23 |
±2.71 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -3.7 |
+2.7 / 1,2 -4.7 |
||||
66 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
72 |
23 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
Note 1: For transmission bandwidths (Figure 5.4.2-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB. Note 2: For the UE maximum output power modified by MPR, the power limits specified in Table 6.2.5.3-1 apply Note 3: For a UE that supports both Band 18 and Band 26, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5dB for transmission bandwidths confined within 815 MHz and 818 MHz |