6.2.3_6 Maximum Power Reduction (MPR) for Multi-Cluster PUSCH with UL 256QAM

36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

6.2.3_6.1 Test purpose

Same test purpose as in clause 6.2.3_2.

6.2.3_6.2 Test applicability

The requirements of this test apply in test cases 6.6.2.3_6 Adjacent Channel Leakage power Ratio for Multi-Cluster PUSCH to E-UTRA UE from release 14 and forward that support UL 256QAM and multi cluster PUSCH within a component carrier for the tested band.

NOTE: As a result TC 6.2.3_6 has not been included in the test case applicability table 4.1-1, TS 36.521-2. This does not preclude the test from being used for R&D or other purposes if deemed useful.

6.2.3_6.3 Minimum conformance requirements

For UE Power Class 1 and 3 transmissions with non-contiguous resource allocation in single component carrier, the allowed Maximum Power Reduction (MPR) for the maximum output power in table 6.2.2.3-1, is specified as follows

MPR = CEIL {MA, 0.5}

Where MA is defined as follows for QPSK, 16 QAM and 64 QAM

MA = 8.00-10.12A ; 0.00< A ≤ 0.33

5.67 – 3.07A ; 0.33< A ≤0.77

3.31 ; 0.77< A ≤1.00

Where MA is defined as follows for 256 QAM

MA = 8.00-10.12A ; 0.00< A ≤ 0.25

5.50 ; 0.25< A < 1.00

Where

A = NRB_alloc / NRB.

CEIL{MA, 0.5} means rounding upwards to closest 0.5dB, i.e. MPR ∈ [3.0, 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0]

For the UE maximum output power modified by MPR, the power limits specified in subclause 6.2.5 apply.

The normative reference for this requirement is TS 36.101 clause 6.2.3.

6.2.3_6.4 Test description

6.2.3_6.4.1 Initial condition

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA operating bands specified in clause 5.4.2.1. All of these configurations shall be tested with applicable test parameters for each channel bandwidth, and are shown in table 6.2.3_6.4.1-1. The details of the uplink reference measurement channels (RMCs) are specified in Annexes A.2. Configurations of PDSCH and PDCCH before measurement are specified in Annex C.2.

Table 6.2.3_6.4.1-1: Test Configuration Table

Initial Conditions

Test Environment as specified in

TS 36.508 [7] subclause 4.1

Normal, TL/VL, TL/VH, TH/VL, TH/VH

Test Frequencies as specified in

TS36.508 [7] subclause 4.3.1

Low range, Mid range, High range

Test Channel Bandwidths as specified in

TS 36.508 [7] subclause 4.3.1

Highest

Test Parameters for Channel Bandwidths

Configuration ID

Downlink Configuration

Uplink Configuration

Ch BW

N/A for Maximum Power Reduction (MPR) test case

Mod’n

Cluster1 RB allocations

(LCRB @ RBstart)

Cluster2 RB allocations

(LCRB @ RBstart)

1

5MHz

256QAM

2@0

1@24

2

5MHz

256QAM

18@0

2@22

3

5MHz

256QAM

2@0

18@6

4

10MHz

256QAM

3@0

2@48

5

10MHz

256QAM

42@0

3@45

6

10MHz

256QAM

3@0

42@6

7

15MHz

256QAM

8@0

7@68

8

15MHz

256QAM

60@0

4@68

9

15MHz

256QAM

4@0

60@12

10

20MHz

256QAM

4@0

4@96

11

20MHz

256QAM

92@0

4@96

12

20MHz

256QAM

4@0

92@8

Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1.

1. Connect the SS and interfering sources to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3.

2. The parameter settings for the cell are set up according to TS 36.508 [7] clause 4.4.3.

3. Downlink signals are initially set up according to Annex C.0, C.1, and C.3.0, and uplink signals according to Annex H.1 and H.3.0.

4. The UL Reference Measurement channels are set according to Table 6.2.3_6.4.1-1.

5. Ensure the UE is in State 3A-RF according to TS 36.508 [7] clause 5.2A.2. Message contents are defined in clause 6.2.3_6.4.3.

6.2.3_6.4.2 Test procedure

Same test procedure as in clause 6.2.3_2.4.2

– Instead of Table 6.2.3_2.4.1-1 🡪 use Table 6.2.3_6.4.1-1

6.2.3_6.4.3 Message contents

Message contents are according to TS 36.508 [7] subclause 4.6.

6.2.3_6.5 Test requirements

The maximum output power, derived in step 3 shall be within the range prescribed by the nominal maximum output power and tolerance in Table 6.2.3_6.5-1.

Table 6.2.3_6.5-1: UE Power Class test requirements for Multi-Cluster PUSCH with UL 256QAM

Configuration ID

EUTRA band

Class 1 (dBm)

Tol. (dB)

Class 2 (dBm)

Tol. (dB)

Class 3 (dBm)

Tol. (dB)

1

31, 51, 72, 73

23

+2,7 / ‑12,7

2

31, 51, 72, 73

23

+2,7 / ‑11,2

3

31, 51, 72, 73

23

+2,7 / ‑11,2

4

5, 6, 8, 11, 12, 13, 14, 17, 24, 27, 30

23

+2,7 / ‑12,7

5

5, 6, 8, 11, 12, 13, 14, 17, 24, 27, 30

23

+2,7 / ‑11,2

6

5, 6, 8, 11, 12, 13, 14, 17, 24, 27, 30

23

+2,7 / ‑11,2

7

18, 19, 21, 26, 34, 68

23

+2,7 / ‑11,7

8

18, 19, 21, 26, 34, 68

23

+2,7 / ‑11,2

9

18, 19, 21, 26, 34, 68

23

+2,7 / ‑11,2

10

1, 2, 3, 4, 7, 9, 10, 20, 23, 25, 28, 33, 35, 36, 37, 38, 39, 40, 41, 44, 45, 50, 65, 66, 70, 71, 74

23

+2,7 / ‑13,2

22, 42, 43, 48

23

+3,0 / ‑13,5

11

1, 2, 3, 4, 7, 9, 10, 20, 23, 25, 28, 33, 35, 36, 37, 38, 39, 40, 41, 44, 45, 50, 65, 66, 70, 71, 74

23

+2,7 / ‑11,2

22, 42, 43, 48

23

+3,0 / ‑11,5

12

1, 2, 3, 4, 7, 9, 10, 20, 23, 25, 28, 33, 35, 36, 37, 38, 39, 40, 41, 44, 45, 50, 65, 66, 70, 71, 74

23

+2,7 / ‑11,2

22, 42, 43, 48

23

+3,0 / ‑11,5