6.2.3_1 Maximum Power Reduction (MPR) for HPUE
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.3_1.1 Test purpose
Same test purpose as in clause 6.2.3.1 with the following exception:
– Instead of Table 6.2.3.3-1 🡪 use Table 6.2.3_1.3-1
6.2.3_1.2 Test applicability
The requirements of this test apply in test cases 6.6.2.3_1 Adjacent Channel Leakage power Ratio for HPUE to all types of E-UTRA Power Class 1 or Power Class 2 UE release 10 and forward.
NOTE: As a result TC 6.2.3_1 has not been included in the test case applicability table 4.1-1, TS 36.521-2. This does not preclude the test from being used for R&D or other purposes if deemed useful.
6.2.3_1.3 Minimum conformance requirements
For UE Power Class 1 and 2, the allowed Maximum Power Reduction (MPR) for the maximum output power in Table 6.2.2_1.3-1 due to higher order modulation and transmit bandwidth configuration (resource blocks) is specified in Table 6.2.3_1.3-1.
Table 6.2.3_1.3-1: Maximum Power Reduction (MPR) for Power Class 1 and 2
Modulation |
Channel bandwidth / Transmission bandwidth configuration [RB] |
MPR (dB) |
|||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
QPSK |
> 5 |
> 4 |
> 8 |
> 12 |
> 16 |
> 18 |
≤ 1 |
16 QAM |
≤ 5 |
≤ 4 |
≤ 8 |
≤ 12 |
≤ 16 |
≤ 18 |
≤ 1 |
16 QAM |
> 5 |
> 4 |
> 8 |
> 12 |
> 16 |
> 18 |
≤ 2 |
For a power class 2 capable UE operating on Band 41, when an IE P-max as defined in [5] of 23 dBm or lower is indicated in the cell or if the TDD frame configuration is 0 or 6, the requirements for power class 2 are not applicable, and the corresponding requirements for a power class 3 UE shall apply.
For the UE maximum output power modified by MPR, the power limits specified in subclause 6.2.5_1.3 apply.
The normative reference for this requirement is TS 36.101 clause 6.2.3.
6.2.3_1.4 Test description
Same test description as in clause 6.2.3.4.
6.2.3_1.5 Test requirements
Same test requirements as in clause 6.2.3.5 with the following exceptions:
– Instead of Table 6.2.3.5-1 🡪 use Table 6.2.3_1.5-1
Table 6.2.3_1.5-1: UE Power Class 1 and 2 test requirements
E-UTRA Band |
Class 1 (dBm) |
Tol. (Db) |
Class 2 (dBm) |
Tol. (dB) |
Class 3 (dBm) |
QPSK partial RB allocation Tol. (dB)) |
QPSK full RB allocation Tol. (dB)) |
16QAM partial RB allocation Tol. (dB) |
16QAM full RB allocation Tol. (dB) |
14 |
31 |
+2.7/ -3.7 |
+2.7 / -4.7 |
+2.7 / -4.7 |
+2.7 / -5.7 |
||||
31 |
31 |
+2.7/ -3.7 |
+2.7 / -4.7 |
+2.7 / -4.7 |
+2.7 / -5.7 |
||||
38 |
26 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
40 |
26 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
41 |
26 |
±2.7 |
+2.7 / -3.7 |
+2.7 / -3.7 |
+2.7 / -4.7 |
||||
42 |
26 |
+3 -4 |
+3.0 / -5.0 |
+3.0 / -5.0 |
+3.0 / -6.0 |
||||
72 |
31 |
+2.7/ -3.7 |
+2.7 / -4.7 |
+2.7 / -4.7 |
+2.7 / -5.7 |
||||
Note 1: For transmission bandwidths (Figure 5.4.2-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB. Note 2: For the UE maximum output power modified by MPR, the power limits specified in Table 6.2.5.3-1 apply |