6.2.2E UE Maximum Output Power for UE category 0
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.2.2E.1 Test purpose
Same test purpose as in clause 6.2.2.1.
6.2.2E.2 Test applicability
This test case applies to all types of E-UTRA UE release 12 and forward of UE category 0.
6.2.2E.3 Minimum conformance requirements
Same minimum conformance requirements as in clause 6.2.2.3
6.2.2E.4 Test description
6.2.2E.4.1 Initial condition
Same initial conditions as in clause 6.2.2.4.1 with the following exceptions:
– Instead of Table 6.2.2.4.1-1 🡪 use Table 6.2.2E.4.1-1.
– Connect the SS to the UE antenna connectors as shown in TS 36.508 [7] Annex A Figure A.3 using only main UE Tx/Rx antenna.
Table 6.2.2E.4.1-1: Test Configuration Table
Initial Conditions |
|||||
Test Environment as specified in TS 36.508 [7] subclause 4.1 |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
||||
Test Frequencies as specified in TS 36.508 [7] subclause 4.3.1 |
Low range, Mid range, High range |
||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
Lowest, 5MHz, Highest |
||||
Test Parameters for Channel Bandwidths |
|||||
Downlink Configuration |
Uplink Configuration |
||||
Ch BW |
N/A for Max UE output power testing |
Mod’n |
RB allocation |
||
FDD and HD-FDD |
TDD |
||||
1.4MHz |
QPSK |
1 |
1 |
||
1.4MHz |
QPSK |
5 |
5 |
||
3MHz |
QPSK |
1 |
1 |
||
3MHz |
QPSK |
4 |
4 |
||
5MHz |
QPSK |
1 |
1 |
||
5MHz |
QPSK |
8 |
8 |
||
10MHz |
QPSK |
1 |
1 |
||
10MHz |
QPSK |
12 |
12 |
||
15MHz |
QPSK |
1 |
1 |
||
15MHz |
QPSK |
16 |
16 |
||
20MHz |
QPSK |
1 |
1 |
||
20MHz |
QPSK |
18 |
18 |
||
Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1. Note 2: For E-UTRA bands not applied with Note 2 in Table 6.2.2.3-1: Note 3: For E-UTRA bands applied with Note 2 in Table 6.2.2.3-1: |
6.2.2E.4.2 Test procedure
Same test procedure as in clause 6.2.2.4.2 with the following exception for HD-FDD:
– In step 3, slots with transient periods are not under test. Half-duplex guard subframes are not under test.
6.2.2E.4.3 Message contents
Message contents are according to TS 36.508 [7] subclause 4.6.
6.2.2E.5 Test requirements
The maximum output power, derived in step 3 shall be within the range prescribed by the nominal maximum output power and tolerance in Table 6.2.2E.5-1.
Table 6.2.2E.5-1: UE Power Class test requirements
EUTRA band |
Class 1 (dBm) |
Tolerance (dB) |
Class 2 (dBm) |
Tolerance (dB) |
Class 3 (dBm) |
Tolerance (dB) |
Class 4 (dBm) |
Tolerance (dB) |
1 |
23 |
±2.7 |
||||||
2 |
23 |
±2.72 |
||||||
3 |
23 |
±2.72 |
||||||
4 |
23 |
±2.7 |
||||||
5 |
23 |
±2.7 |
||||||
6 |
23 |
±2.7 |
||||||
7 |
23 |
±2.72 |
||||||
8 |
23 |
±2.72 |
||||||
9 |
23 |
±2.7 |
||||||
10 |
23 |
±2.7 |
||||||
11 |
23 |
±2.7 |
||||||
12 |
23 |
±2.72 |
||||||
13 |
23 |
±2.7 |
||||||
14 |
23 |
±2.7 |
||||||
… |
||||||||
17 |
23 |
±2.7 |
||||||
18 |
23 |
±2.76 |
||||||
19 |
23 |
±2.7 |
||||||
20 |
23 |
±2.72 |
||||||
21 |
23 |
±2.7 |
||||||
22 |
23 |
+3.0/-4.5 |
||||||
23 |
235 |
±2.75 |
||||||
24 |
23 |
±2.7 |
||||||
25 |
23 |
±2.72 |
||||||
26 |
23 |
±2.72 |
||||||
27 |
23 |
±2.7 |
||||||
28 |
23 |
+2.7/-3.2 |
||||||
30 |
23 |
±2.7 |
||||||
31 |
23 |
±2.7 |
||||||
… |
||||||||
33 |
23 |
±2.7 |
||||||
34 |
23 |
±2.7 |
||||||
35 |
23 |
±2.7 |
||||||
36 |
23 |
±2.7 |
||||||
37 |
23 |
±2.7 |
||||||
38 |
23 |
±2.7 |
||||||
39 |
23 |
±2.7 |
||||||
40 |
23 |
±2.7 |
||||||
41 |
23 |
±2.72 |
||||||
42 |
23 |
+3.0/-4.0 |
||||||
43 |
23 |
+3.0/-4.0 |
||||||
44 |
23 |
+2.7/[-3.7] |
||||||
45 |
23 |
±2.7 |
||||||
… |
||||||||
Note 1: The above tolerances are applicable for UE(s) that support up to 4 E-UTRA operating bands. For UE(s) that support 5 or more E-UTRA bands the maximum output power is expected to decrease with each additional band and is FFS Note 2: For transmission bandwidths (Figure 5.4.2-1, Table 5.4.4-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB Note 3: PPowerClass is the maximum UE power specified without taking into account the tolerance. Note 4: For the UE which supports both Band 11 and Band 21 operating frequencies, the tolerance is FFS. Note 5: When NS_20 is signalled, the total output power within 2000-2005 MHz shall be limited to 7 dBm. Note 6: For a UE that supports both Band 18 and Band 26, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5dB for transmission bandwidths confined within 815 MHz and 818 MHz. |