6.2.2_1 Maximum Output Power for HPUE
36.521-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 1: Conformance testingRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
Editor’s note: For a transition period until RAN5#81, this test case in version 15.2.0 of 36.521-1 is allowed to be used.
6.2.2_1.1 Test purpose
Same test purpose as in clause 6.2.2.1.
6.2.2_1.2 Test applicability
This test case applies to all types of E-UTRA UE Power Class 1 or Power Class 2 release 10 and forward.
6.2.2_1.3 Minimum conformance requirements
The following defines the maximum output power for any transmission bandwidth within the channel bandwidth for Power Class 1 and Power Class 2 UE. The period of measurement shall be at least one sub frame (1ms).
Table 6.2.2_1.3-1: HPUE Power Class
EUTRA band |
Class 1 (dBm) |
Tolerance (dB) |
Class 2 (dBm) |
Tolerance (dB) |
Class 3 (dBm) |
Tolerance (dB) |
Class 4 (dBm) |
Tolerance (dB) |
14 |
31 |
+2/-31 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
31 |
31 |
+2/-31 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
38 |
N/A |
N/A |
26 |
±2 |
N/A |
N/A |
N/A |
N/A |
40 |
N/A |
N/A |
26 |
±2 |
N/A |
N/A |
N/A |
N/A |
41 |
N/A |
N/A |
26 |
±22 |
N/A |
N/A |
N/A |
N/A |
42 |
N/A |
N/A |
26 |
+2/-3 |
N/A |
N/A |
N/A |
N/A |
72 |
31 |
+2/-31 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
87 |
31 |
+2/-31 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
88 |
31 |
+2/-31 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
Note 1: The above tolerances are applicable for UE(s) that support up to 4 E-UTRA operating bands. For UE(s) that support 5 or more E-UTRA bands the maximum output power is expected to decrease with each additional band and is FFS Note 2: For transmission bandwidths (Figure 5.4.2-1, Table 5.4.4-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB Note 3: N/A Note 4: PPowerClass is the maximum UE power specified without taking into account the tolerance Note 5-6: N/A |
For a power class 2 capable UE operating on Band 41, when an IE P-max as defined in [5] of 23 dBm or lower is indicated in the cell or if the TDD frame configuration is 0 or 6, the requirements for power class 2 are not applicable, and the corresponding requirements for a power class 3 UE shall apply.
The normative reference for this requirement is TS 36.101 clause 6.2.2.
6.2.2_1.4 Test description
Same test description as in clause 6.2.2.4 with the following exceptions:
– Instead of Table 6.2.2.4.1-1🡪 use Table 6.2.2_1.4-1
Table 6.2.2_1.4-1: Test Configuration Table
Initial Conditions |
|||||
Test Environment as specified in TS 36.508 [7] subclause 4.1 |
Normal, TL/VL, TL/VH, TH/VL, TH/VH |
||||
Test Frequencies as specified in TS 36.508 [7] subclause 4.3.1 |
Low range, Mid range, High range |
||||
Test Channel Bandwidths as specified in TS 36.508 [7] subclause 4.3.1 |
Lowest, 5MHz, Highest |
||||
Test Parameters for Channel Bandwidths |
|||||
Downlink Configuration |
Uplink Configuration |
||||
Ch BW |
N/A for Max UE output power testing |
Mod’n |
RB allocation |
||
FDD |
TDD |
||||
1.4MHz |
QPSK |
1 |
1 |
||
1.4MHz |
QPSK |
5 |
5 |
||
3MHz |
QPSK |
1 |
1 |
||
3MHz |
QPSK |
4 |
4 |
||
5MHz |
QPSK |
1 |
1 |
||
5MHz |
QPSK |
8 |
8 |
||
10MHz |
QPSK |
1 |
1 |
||
10MHz |
QPSK |
12 |
12 |
||
15MHz |
QPSK |
1 |
1 |
||
15MHz |
QPSK |
16 |
16 |
||
20MHz |
QPSK |
1 |
1 |
||
20MHz |
QPSK |
18 |
18 |
||
Note 1: Test Channel Bandwidths are checked separately for each E-UTRA band, the applicable channel bandwidths are specified in Table 5.4.2.1-1. Note 2: For E-UTRA bands not applied with Note 2 in Table 6.2.2_1.3-1: Note 3: For E-UTRA bands applied with Note 2 in Table 6.2.2_1.3-1: |
– Message contents are according to TS 36.508 [7] subclause 4.4.3.2 with the following exceptions:
Table 6.2.2_1.4-2: SystemInformationBlockType1: Test point 1
Derivation Path: 36.508 [7] clause 4.4.3.2, Table 4.4.3.2-1 SystemInformationBlockType1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
p-Max |
31 dBm 26 dBm Not present |
for Power Class 1 for Power Class 2 other than Band 41 for Power Class 2 Band 41 See Table 6.2.2_1.3-1 |
6.2.2_1.5 Test requirements
The maximum output power, derived in step 3 shall be within the range prescribed by the nominal maximum output power and tolerance in Table 6.2.2_1.5-1
Table 6.2.2_1.5-1: HPUE Power Class test requirements
EUTRA band |
Class 1 (dBm) |
Tolerance (dB) |
Class 2 (dBm) |
Tolerance (dB) |
Class 3 (dBm) |
Tolerance (dB) |
Class 4 (dBm) |
Tolerance (dB) |
14 |
31 |
+2.7/-3.71 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
31 |
31 |
+2.7/-3.71 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
38 |
N/A |
N/A |
26 |
±2.7 |
N/A |
N/A |
N/A |
N/A |
40 |
N/A |
N/A |
26 |
±2.7 |
N/A |
N/A |
N/A |
N/A |
41 |
N/A |
N/A |
26 |
±2.72 |
N/A |
N/A |
N/A |
N/A |
42 |
N/A |
N/A |
26 |
+3/-4 |
N/A |
N/A |
N/A |
N/A |
72 |
31 |
+2.7/-3.71 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
87 |
31 |
+2.7/-3.71 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
88 |
31 |
+2.7/-3.71 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
Note 1: The above tolerances are applicable for UE(s) that support up to 4 E-UTRA operating bands. For UE(s) that support 5 or more E-UTRA bands the maximum output power is expected to decrease with each additional band and is FFS Note 2: For transmission bandwidths (Figure 5.4.2-1, Table 5.4.4-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB. |