26.6.3 Test of measurement report
3GPP51.010-1Mobile Station (MS) conformance specificationPart 1: Conformance specificationTS
When an RR-connection exists, the MS shall send measurement reports. These reports contain reception characteristics from serving and neighbouring cells. The measurement report procedure is described in subclause 3.4.1.2 of 3GPP TS 04.08 / 3GPP TS 44.018.
NOTE 8: The capability to calculate RxLev and RxQual is tested in clauses 15 and 16. In this test only the signalling aspect is verified.
26.6.3.1 Measurement / no neighbours
26.6.3.1.1 Conformance requirements
The MS shall continuously send MEASUREMENT REPORT messages on every SACCH block and the measurement valid indication shall be set to valid (0) within the second block at the latest.
References
3GPP TS 04.08 / 3GPP TS 44.018, subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.1.2 Test purpose
To test that, when the SS gives absolutely no information about neighbouring cells, the MS does not report on neighbouring cells.
26.6.3.1.3 Method of test
Initial Conditions
System Simulator:
8 cells with the following settings:
Transmitter |
|||||||||
Serving |
Neighbour |
||||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
N7 |
||
Level |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
-40 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
1 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
288 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
335 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
171 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
044 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
0008H |
With the exception of the Cell Allocation, the rest of the parameters for all eight cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed twice.
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5 & 6 (on the second iteration of the test the SS also sends SYSTEM INFORMATION TYPE 5bis) on the SACCH. The BA is indicated as empty. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated in these that no measurement results have been obtained.
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
This sequence is performed for execution counter, k = 1, 2.
Since when k = 1, SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT (and when k = 2 an additional SYSTEM INFORMATION TYPE 5bis is included) are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
DCS 1 800 or PCS 1 900 begin:
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format |
1 024 range |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
k = 1. Information Element carries the complete BA. k = 2. Information Element carries only a part of the BA. |
– W(i) |
null. |
Band |
NCD Format |
GSM 450 |
Range 128 |
GSM 480 |
Range 128 |
GSM 710 |
Range 128 |
GSM 750 |
Range 128 |
T-GSM 810 |
Range 128 |
GSM 850 |
Range 128 |
GSM 900 |
Bitmap 0 |
DCS 1 800 |
Range 1 024 |
PCS 1 900 |
Range 1 024 |
SYSTEM INFORMATION TYPE 5bis (Sent only when k = 2):
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5bis. |
Neighbour Cells Description |
|
– Format |
1 024 range |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– W(i) |
DCS 1 800 or PCS 1 900: null. Other bands: Only channel 500 belongs to the BCCH allocation |
DCS 1 800 or PCS 1 900 begin:
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio_Link_Timeout |
default |
PLMN permitted |
only NCC 1 permitted |
DCS 1 800 or PCS 1 900 end:MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 2 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
No neighbour cell measurement result, or Neighbour cell information not available for serving cell. |
RXLEV_NCELL_1 |
00 0000 |
BCCH_FREQ_NCELL_1 |
0 0000 |
BSIC_NCELL_1 |
00 0000 |
. . . |
. . |
. . . |
. . |
RXLEV_NCELL_6 |
00 0000 |
BCCH_FREQ_NCELL_6 |
0 0000 |
BSIC_NCELL_6 |
00 0000 |
DSC1800 or PCS 1 900 end:
NOTE 1: The actual values are not checked.
NOTE 2: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE.
26.6.3.2 Measurement / all neighbours present
26.6.3.2.1 Conformance requirements
The MS shall continuously send MEASUREMENT REPORT messages on every SACCH blocks and the measurement valid indication shall be set to valid (0) within the second block at the latest. The MEASUREMENT REPORT message shall contain measurement results for the 6 strongest BCCH carriers with known and allowed NCC part of BSIC.
References
3GPP TS 04.08 / 3GPP TS 44.018, subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.2.2 Test purpose
To test that, when the SS gives information about neighbouring cells, the MS reports appropriate results.
26.6.3.2.3 Method of test
Initial Conditions
System Simulator:
8 cells with the following settings:
Transmitter |
|||||||||
Serving |
Neighbour |
||||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
N7 |
||
Level |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
-40 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
1 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
288 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
335 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
171 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
044 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
0008H |
With the exception of the Cell Allocation, the rest of the parameters for all eight cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed twice.
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5 and 6 (on the second iteration of the test the SS also sends SYSTEM INFORMATION TYPE 5bis) on the SACCH. All 8 of the BCCHs "on air" are indicated in the BA. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated within 20 s in these that measurement results for the 6 strongest carriers have been obtained.
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
This sequence is performed for execution counter, k = 1, 2.
Since when k = 1, SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT (and when k = 2 an additional SYSTEM INFORMATION TYPE 5bis is included) are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format |
See table below |
– BCCH Allocation Sequence |
1 |
– EXT IND |
k = 1. Information Element carries complete BA. k = 2. Information Element carries only a part of the BA. |
– BCCH Allocation ARFCN |
See table below |
Band |
SYSTEM INFORMATION TYPE 5 |
||
Format Identifier |
BCCH Allocation ARFCN k = 1 |
BCCH Allocation ARFCN k = 2 |
|
GSM 450 |
Variable bitmap |
259, 260, 261, 262, 263, 264, 265, 267, 268, 269, 270, 271, 272, 273, 274, 275, 276, 278, 279, 280, 281, 282, 283, 284, 285, 286, 287, 288, 289, 290, 291, 292 |
|
GSM 480 |
Variable bitmap |
306, 307, 308, 309, 310, 311, 312, 314, 315, 316, 317, 318, 319, 320, 321, 322, 323, 325, 326, 327, 328, 329, 330, 331, 332, 333, 334, 335, 336, 337, 338 , 339 |
|
GSM 710 |
Range 128 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472, 473, 475, 477, 481 |
|
GSM 750 |
Range 128 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472, 473, 475, 477, 481 |
|
T-GSM 810 |
Range 128 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472, 473, 475, 477, 481 |
|
GSM 850 |
Range 128 |
129, 135, 141, 147, 153, 159, 165, 171 |
|
GSM 900 |
Bitmap 0 |
2, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 16, 17, 18, 19, 20, 21, 22, 23, 24, 26, 28, 29, 30, 32, 34, 35, 36, 38, 40, 44 |
|
DCS 1 800 |
Range 1 024 |
514, 530, 549, 602, 665, 686, 762, 810 |
549, 602, 665, 686, 810. |
PCS 1 900 |
Range 1 024 |
514, 530, 549, 602, 665, 686, 762, 810 |
549, 602, 665, 686, 810. |
SYSTEM INFORMATION TYPE 5bis (Sent only when k = 2):
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5bis. |
Neighbour Cells Description |
|
– Format |
1 024 range |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– W(i) |
DCS 1 800 or PCS 1 900: Channel 20, 514, 530, 549, 762 belong to the BCCH allocation. Other bands: Channel 0 and 800 belong to the BCCH allocation.. |
DCS 1 800 or PCS 1 900 begin:
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio_Link_Timeout |
default |
PLMN permitted |
only NCC 1 permitted |
DCS 1 800 or PCS 1 900 end:
MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 2 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
6 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 1 |
BCCH_FREQ_NCELL_1 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 1 |
BCCH_FREQ_NCELL_2 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
See note 1 |
BCCH_FREQ_NCELL_3 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
RXLEV_NCELL_4 |
See note 1 |
BCCH_FREQ_NCELL_4 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
RXLEV_NCELL_5 |
See note 1 |
BCCH_FREQ_NCELL_5 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_5 |
Corresponds to that of BCCH_FREQ_NCELL_5 |
RXLEV_NCELL_6 |
See note 1 |
BCCH_FREQ_NCELL_6 |
Shall not correspond to N1 or N2 |
BSIC_NCELL_6 |
Corresponds to that of BCCH_FREQ_NCELL_6 |
NOTE 1: These actual values are not checked.
NOTE 2: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE.
26.6.3.3 Measurement / barred cells and non-permitted NCCs
26.6.3.3.1 Conformance requirements
The MS shall continuously send MEASUREMENT REPORTs on every SACCH blocks and the measurement valid indication shall be set to valid (0) within the second block at the latest. After 20 s the messages shall contain measurement results only for the 4 BCCH carriers on which the MS is allowed to report.
References
3GPP TS 04.08 / 3GPP TS 44.018 subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.3.2 Test purpose
To test that, when a combination of normal neighbours, barred cells and non-permitted NCCs is "on air", the MS reports only on normal neighbours.
26.6.3.3.3 Method of test
Initial Conditions
System Simulator:
8 cells with the following settings:
Transmitter |
|||||||||
Serving |
Neighbour |
||||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
N7 |
||
Level dBm |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
-40 |
|
NCC |
1 |
1 |
1 |
2 |
3 |
4 |
1 |
1 |
|
BCC |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
1 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
0008H |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
288 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
335 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
171 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
044 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
With the exception of the Cell Allocation, the rest of the parameters for all eight cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
NOTE 1: The BA sent in SYSTEM INFORMATION TYPE 5 does not include N1, N4 and N5. N1 may be the case of a barred cell, N3 simulates the case where another operator is transmitting on the same frequency (e.g. in border areas), N4 & N5 simulate the case where other operators are transmitting on other frequencies.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed twice.
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5 and 6 (on the second iteration of the test the SS also sends SYSTEM INFORMATION TYPE 5bis) on the SACCH. 5 of the 8 BCCHs "on air" are indicated in the BA. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated in these that measurement results for the 4 strongest permitted carriers have been obtained (one of the carriers in the BA belongs to a non-permitted NCC).
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
This sequence is performed for execution counter, k = 1, 2.
Since when k = 1 SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT (and when k = 2 an additional SYSTEM INFORMATION TYPE 5bis is included) messages are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format |
1024 range |
– BCCH Allocation Sequence |
1 |
– EXT IND |
k = 1. Information Element carries complete BA. k = 2. Information Element carries only a part of the BA. |
– BCCH Allocation ARFCN |
only channel numbers from the table below belong to the BCCH allocation.. |
Format |
BA ARFCNs K=1 |
BA ARFCNs K=2 |
|
GSM 450 |
Range 128 |
260, 268, 272, 284 and 288 |
260, 268, 272, 284 and 288 |
GSM 480 |
Range 128 |
307, 315, 319, 331 and 335 |
307, 315, 319, 331 and 335 |
GSM 710 |
Range 128 |
439, 451, 457, 475 and 481 |
439, 451, 457, 475 and 481 |
GSM 750 |
Range 128 |
439, 451, 457, 475 and 481 |
439, 451, 457, 475 and 481 |
T-GSM 810 |
Range 128 |
439, 451, 457, 475 and 481 |
439, 451, 457, 475 and 481 |
GSM 850 |
Range 128 |
129, 141, 147, 165 and 171 |
129, 141, 147, 165 and 171 |
GSM 900 |
Bitmap 0 |
2, 14, 20, 38, and 44 |
2, 14, 20, 38, and 44 |
DCS 1 800 |
Range 1 024 |
514, 549, 602, 665, 810 |
549, 602, 810 |
PCS 1 900 |
Range 1 024 |
514, 549, 602, 665, 810 |
549, 602, 810 |
SYSTEM INFORMATION TYPE 5bis (Sent only when k = 2):
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5bis. |
Neighbour Cells Description |
|
– Format |
1024 range |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– BCCH Allocation ARFCN |
DCS 1 800 or PCS 1 9 00:514, 665. Other bands: 0, 800 |
DCS 1 800 or PCS 1 900 begin:
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio-Link-Time-out |
default |
PLMN permitted |
only NCC 1 permitted |
DCS 1 800 or PCS 1 900 end:
MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 2 |
RXLEV_SUB_SERVING_CELL |
See note 2 |
MEAS_VALID |
See note 3 |
RXQUAL_FULL_SERVING_CELL |
See note 2 |
RXQUAL_SUB_SERVING_CELL |
See note 2 |
NO_NCELL_M |
4 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 2 |
BCCH_FREQ_NCELL_1 |
Corresponds to one of N7, N6, S1 or N2 |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 2 |
BCCH_FREQ_NCELL_2 |
Corresponds to one of N7, N6, S1 or N2 |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
See note 2 |
BCCH_FREQ_NCELL_3 |
Corresponds to one of N7, N6, S1 or N2 |
BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
RXLEV_NCELL_4 |
See note 2 |
BCCH_FREQ_NCELL_4 |
Corresponds to one of N7, N6, S1 or N2 |
BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
RXLEV_NCELL_5 |
00 00000 |
BCCH_FREQ_NCELL_5 |
0 0000 |
BSIC_NCELL_5 |
00 0000 |
RXLEV_NCELL_6 |
00 0000 |
BCCH_FREQ_NCELL_6 |
0 0000 |
BSIC_NCELL_6 |
00 0000 |
NOTE 2: These actual values are not checked.
NOTE 3: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 2 applies to ALL fields of the Measurement Results IE.
26.6.3.4 Measurement / DTX
26.6.3.4.1 Conformance requirements
After the sending of the HANDOVER COMPLETE, the MS shall continuously send measurement reports in every SACCH blocks, the measurement valid indication shall be set to valid (0) within the second block at the latest. After 20 s the order of values in the MEASUREMENT REPORT message shall contain measurement results for the 6 strongest BCCH carriers among those monitored by the MS. Further, in a quiet environment, the DTX_USED field shall be set by the MS to "DTX used".
References
3GPP TS 04.08 / 3GPP TS 44.018 subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.4.2 Test purpose
To test that, in the case of the MS using DTX and the SS indicating that power control is in use, the MS reports appropriate results.
26.6.3.4.3 Method of test
Initial Conditions
System Simulator:
8 cells with the following settings:
Transmitter |
|||||||||
Serving |
Neighbour |
||||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
N7 |
||
Level dBm |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
-40 |
|
NCC |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
BCC |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
1 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
0008H |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
288 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
335 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
171 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
044 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
In the serving cell, the DTX indicator is set to "MS shall use discontinuous transmission".
With the exception of the Cell Allocation, the rest of the parameters for all eight cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
The MS has just completed a handover into the serving cell, S1.
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed twice.
With the MS having a call in progress on an arbitrary cell, the MS is handed over to cell S1. On cell S1, the SS sends SYSTEM INFORMATION TYPE 5 and 6 (on the second iteration of the test the SS also sends SYSTEM INFORMATION TYPE 5bis) on the SACCH with all 8 of the BCCHs "on air" indicated in the BA. Cell S1 also indicates that DTX shall be used. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated in these that measurement results for the 6 strongest carriers have been obtained and that DTX has been used. (The MS is positioned in an environment free from acoustic noise.)
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
This sequence is performed twice for execution counter, k = 1, 2.
Since when k = 1, SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT (and when k = 2 an additional SYSTEM INFORMATION TYPE 5bis is included) messages are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Neighbour Cells Description |
|
– Format Identifier |
See table below |
– BCCH Allocation Sequence |
1 |
– BCCH Allocation ARFCN |
only channel numbers from the table below belong to the BCCH allocation. |
– EXT IND |
k = 1. Information Element carries the complete BA. k = 2. Information Element carries only a part of the BA. |
Band |
Format |
BCCH Allocation ARFCN k = 1 |
BCCH Allocation ARFCN k = 2 |
GSM 450 |
Range 128 |
260, 264, 268, 272, 276, 280, 284, 288 |
260, 264, 268, 272, 276, 280, 284, 288 |
GSM 480 |
Range 128 |
307, 211, 315, 319, 323, 327, 331, 335 |
307, 211, 315, 319, 323, 327, 331, 335 |
GSM 710 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 750 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
439, 445, 451, 457, 463, 469, 475, 481 |
T-GSM 810 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 850 |
Range 128 |
129, 135, 141, 147, 153, 159, 165, 171 |
129, 135, 141, 147, 153, 159, 165, 171 |
GSM 900 |
Bitmap 0 |
2, 8, 14, 20, 26, 32, 38, 44 |
2, 8, 14, 20, 26, 32, 38, 44 |
DCS 1 800 |
Range 1 024 |
514, 530, 549, 602 665, 686, 762, 810. |
549, 602, 665, 686, 810 |
PCS 1 900 |
Range 1 024 |
514, 530, 549, 602, 665, 686, 762, 810. |
549, 602, 665, 686, 810 |
SYSTEM INFORMATION TYPE 5bis (Sent only when k = 2):
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5bis. |
Neighbour Cells Description |
|
– Format |
1024 range |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– BCCH Allocation ARFCN |
DCS 1 800 or PCS 1 900: Channels 514, 530, 762 belong to the BCCH allocation. Other bands: Only channel 500 belongs to the BCCH allocation. |
SYSTEM INFORMATION TYPE 6:
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
Default |
LAI |
Default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall use DTX |
– Radio_Link_Timeout |
DCS 1 800 or PCS 1 900: default Other bands: 8 |
PLMN permitted (DCS 1 800 and PCS 1 900 only) |
only NCC 1 permitted |
MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
– BA_used |
1 (note 4) |
– DTX_used |
DTX was used (note 3) |
– RXLEV_FULL_SERVING_CELL |
See note 1 |
– RXLEV_SUB_SERVING_CELL |
See note 1 |
– MEAS_VALID |
See note 2 |
– RXQUAL_FULL_SERVING_CELL |
See note 1 |
– RXQUAL_SUB_SERVING_CELL |
See note 1 |
– NO_NCELL_M |
6 neighbour cell measurement results |
– RXLEV_NCELL_1 |
See note 1 |
– BCCH_FREQ_NCELL_1 |
Shall not correspond to N1 or N2 |
_ BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
– RXLEV_NCELL_2 |
See note 1 |
– BCCH_FREQ_NCELL_2 |
Shall not correspond to N1 or N2 |
– BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
– RXLEV_NCELL_3 |
See note 1 |
– BCCH_FREQ_NCELL_3 |
Shall not correspond to N1 or N2 |
– BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
– RXLEV_NCELL_4 |
See note 1 |
– BCCH_FREQ_NCELL_4 |
Shall not correspond to N1 or N2 |
– BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
– RXLEV_NCELL_5 |
See note 1 |
– BCCH_FREQ_NCELL_5 |
Shall not correspond to N1 or N2 |
– BSIC_NCELL_5 |
Corresponds to that of BCCH_FREQ_NCELL_5 |
– RXLEV_NCELL_6 |
See note 1 |
– BCCH_FREQ_NCELL_6 |
Shall not correspond to N1 or N2 |
– BSIC_NCELL_6 |
Corresponds to that of BCCH_FREQ_NCELL_6 |
NOTE 1: These actual values are not checked.
NOTE 2: The Measurement Valid Indication shall be set to valid within the second SACCH block after the HANDOVER COMPLETE message at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE.
NOTE 3: The DTX_used flag must only be checked from the MEASUREMENT REPORT occurring 2 complete SACCH multiframes after the MS has received SYSTEM INFORMATION TYPE 6. This is necessary to give the MS one SACCH multiframe to apply DTX and the second to transmit the updated MESUREMENT REPORT.
NOTE 4: The BA_used flag must only be checked from the MEASUREMENT REPORT occurring 1 complete SACCH multiframe after the MS has received SYSTEM INFORMATION TYPE 5 (and SYSTEM INFO TYPE 5BIS in the case of k=2). This is necessary to give the MS one SACCH multiframe to transmit the updated MESUREMENT REPORT.
26.6.3.5 Measurement / Frequency Formats
26.6.3.5.1 Conformance Requirement
The MS shall continuously send MEASUREMENT REPORT messages on every SACCH blocks and the measurement valid indication shall be set to valid (0) within the second block at the latest. After 20 s the values in the MEASUREMENT REPORT message shall contain measurement results for the cells on which the mobile is allowed to report.
References
3GPP TS 04.08 / 3GPP TS 44.018 subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.5.2 Test Purpose
To test that, when the SS gives information about neighbouring cells, the MS reports appropriate results.
26.6.3.5.3 Method of test
Initial Conditions
System Simulator:
2 cells with the following settings:
Transmitter |
|||
Serving |
Neighbour |
||
S1 |
N1 |
||
Level |
-60 |
-85 |
|
Ncc |
1 |
1 |
|
Bcc |
3 |
5 |
|
ARFCN |
GSM 450 |
260 |
264 |
GSM 480 |
307 |
311 |
|
GSM 710 |
439 |
445 |
|
GSM 750 |
439 |
445 |
|
T-GSM 810 |
439 |
445 |
|
GSM 850 |
129 |
135 |
|
GSM 900 |
002 |
008 |
|
DCS 1 800 |
715 |
805 |
|
PCS 1 900 |
715 |
805 |
|
Cell Identity |
0001H |
0002H |
With the exception of the Cell Allocation, the rest of the parameters for both cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed three times.
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5, 5bis and 6 on the SACCH. Both of the BCCHs "on air" are indicated in the BA. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated in these that the appropriate measurement results have been obtained as specified in the Specific Message Contents.
For each iteration of the test the frequency format of the BA list contained in the System Information 5 and 5bis message shall change according to the specific message contents.
Maximum Duration Of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
This sequence is performed for execution counter, K = 1, 2, 3.
Since SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION 5bis, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format |
See table below |
– BCCH Allocation Sequence |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– BCCH Allocation ARFCNs |
See table below |
Band |
k |
Format |
BCCH Allocation ARFCN |
GSM 450 |
1, 2, 3 |
Range 128 |
260, 262 and 264 |
GSM 480 |
1, 2, 3 |
Range 128 |
307, 309 and 311 |
GSM 710 |
1, 2, 3 |
Range 128 |
439, 443 and 445 |
T-GSM 810 |
1, 2, 3 |
Range 128 |
439, 443 and 445 |
GSM 750 |
1, 2, 3 |
Range 128 |
439, 443 and 445 |
GSM 850 |
1 |
Variable Bitmap |
129, 133, 135 |
GSM 850 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 810, 0 |
GSM 850 |
3 |
Range 256 |
130, 135, 138 |
GSM 900 |
1 |
Bitmap 0 |
2, 6, 8 |
GSM 900 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
GSM 900 |
3 |
Range 128 |
3, 8, 10 |
DCS 1 800 |
1 |
Range 1 024 |
500, 530, 595, 715, 815, 965, 1 000, 0 |
DCS 1 800 |
2 |
Variable Bitmap |
965, 1 000, 0, 2, 6, 8 |
DCS 1 800 |
3 |
Range 128 |
695, 715, 800 |
PCS 1 900 |
1 |
Range 1 024 |
500, 530, 595, 715, 805, 965, 1 000, 0 |
PCS 1 900 |
2 |
Variable Bitmap |
965, 1 000, 0, 2, 6, 8 |
PCS 1 900 |
3 |
Range 128 |
695, 715, 800 |
SYSTEM INFORMATION TYPE 5bis:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5bis. |
Neighbour Cells Description |
|
– Format |
K = 1. Bit Map 0. K = 2. Range 512 Format K = 3. Range 256 Format |
– BCCH Allocation Sequence number |
1 |
– EXT IND |
Information Element carries only a part of the BA. |
– W(i) / BCCH Allocation |
K = 1. Non null for 2, 6, 8 K = 2. Non null for 500, 530, 595, 715, 815, 965 K = 3. Non Null for 815, 965, 1000, 0, 2, 6 |
Band |
k |
Format Identifier |
BCCH Allocation ARFCN |
GSM 450 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
GSM 450 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
GSM 450 |
3 |
Variable Bitmap |
965, 1000, 0, 260, 262 |
GSM 480 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
GSM 480 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
GSM 480 |
3 |
Variable Bitmap |
965, 1000, 0, 307, 309 |
GSM 710 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
GSM 710 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
GSM 710 |
3 |
Variable Bitmap |
965, 1000, 0, 260, 262 |
GSM 750 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
GSM 750 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
GSM 750 |
3 |
Variable Bitmap |
965, 1000, 0, 260, 262 |
T-GSM 810 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
T-GSM 810 |
2 |
Range 512 |
530, 595, 965, 1000, 715, 815, 0 |
T-GSM 810 |
3 |
Variable Bitmap |
965, 1000, 0, 260, 262 |
GSM 850 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 810, 0 |
GSM 850 |
2 |
Range 128 |
129, 133, 135 |
GSM 850 |
3 |
Range 512 |
965, 1000, 0, 129, 133 |
GSM 900 |
1 |
Range 1 024 |
500, 530, 595, 965, 1000, 715, 815, 0 |
GSM 900 |
2 |
Range 512 |
2, 6, 8 |
GSM 900 |
3 |
Variable Bitmap |
965, 1000, 0, 2, 6 |
DCS 1 800 |
1 |
Bitmap 0 |
2, 6, 8 |
DCS 1 800 |
2 |
Range 512 |
500, 530, 595, 715, 815, 965 |
DCS 1 800 |
3 |
Range 256 |
815, 965, 1000, 0, 2, 6 |
PCS 1 900 |
1 |
Bitmap 0 |
2, 6, 8 |
PCS 1 900 |
2 |
Range 512 |
500, 530, 595, 715, 805, 965 |
PCS 1 900 |
3 |
Range 256 |
805, 965, 1000, 0, 2, 6 |
DCS 1 800 or PCS 1 9 00 begin:
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio_Link_Timeout |
default |
PLMN permitted |
only NCC 1 permitted |
DCS 1 800 or PCS 1 9 00 end:
MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 2 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
2 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 1 |
BCCH_FREQ_NCELL_1 |
Shall correspond to S1 or N1, i.e., value in table below. |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 1 |
BCCH_FREQ_NCELL_2 |
Shall correspond to S1 or N1, i.e., value in table below. |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
00 0000 |
BCCH_FREQ_NCELL_3 |
0 0000 |
BSIC_NCELL_3 |
00 0000 |
. . . |
. . |
. . . |
. . |
RXLEV_NCELL_6 |
00 0000 |
BCCH_FREQ_NCELL_6 |
0 0000 |
BSIC_NCELL_6 |
00 0000 |
MEASUREMENT REPORT |
|||
Band |
k |
BCCH_FREQ_NCELL_1 |
BCCH_FREQ_NCELL_2 |
GSM 450 |
1, 2, 3 |
0 or 2 |
0 or 2 |
GSM 480 |
1, 2, 3 |
0 or 2 |
0 or 2 |
GSM 710 |
1, 2, 3 |
0 or 2 |
0 or 2 |
GSM 750 |
1, 2, 3 |
0 or 2 |
0 or 2 |
T-GSM 810 |
1, 2, 3 |
0 or 2 |
0 or 2 |
GSM 850 |
1, 2 |
0 or 2 |
0 or 2 |
GSM 850 |
3 |
0 or 3 |
0 or 3 |
GSM 900 |
1, 2 |
0 or 2 |
0 or 2 |
GSM 900 |
3 |
0 or 3 |
0 or 3 |
DCS 1 800 |
1, 2 |
6 or 7 |
6 or 7 |
DCS 1 800 |
3 |
3 or 5 |
3 or 5 |
PCS 1 900 |
1, 2 |
6 or 7 |
6 or 7 |
PCS 1 900 |
3 |
3 or 5 |
3 or 5 |
NOTE 1: These actual values are not checked.
NOTE 2: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE.
26.6.3.6 Measurement / multiband environment
26.6.3.6.1 Conformance requirements
The MS shall continuously send MEASUREMENT REPORT messages on every SACCH blocks and the measurement valid indication shall be set to valid (0) within the second block at the latest. The MEASUREMENT REPORT message shall contain measurement results for up to the 6 strongest BCCH carriers among those with known and allowed NCC part of BSIC on which the mobile is asked to report.
References
3GPP TS 04.08 / 3GPP TS 44.018 subclause 3.4.1.2, 3GPP TS 05.08 subclause 8.4.
26.6.3.6.2 Test purpose
To test that, when the SS gives information about neighbouring cells using SYSTEM INFORMATION TYPE 2ter/5ter, the MS reports appropriate results.
26.6.3.6.3 Method of test
Initial Conditions
System Simulator:
8 cells with the following settings:
Transmitter |
|||||||||
Serving |
Neighbour |
||||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
N7 |
||
Level |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
-40 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
1 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
288 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
335 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
481 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
171 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
044 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
810 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
0008H |
With the exception of the Cell Allocation, the rest of the parameters for all eight cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1, 2 and 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
This test procedure is performed once.
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5, 5ter & 6 on the SACCH. All 8 of the BCCHs "on air" are indicated in the BA. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated within 20 s in these that measurement results for the 6 strongest carriers, on which the mobile is asked to report, have been obtained.
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
Since SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 5ter, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 2ter:
Information Element |
value/remark |
Additional Multiband information |
|
– Multiband reporting |
Minimum 2 cells reported from each band supported excluding the frequency band of the serving cell. |
Extension of the BCCH Frequency list |
|
– Format identifier |
See table below |
– BCCH Allocation Sequence |
0 |
– BCCH Allocation ARFCN |
ARFCN 514, 530, 549, 602, 665, 686, 762, 810 |
Band |
Format |
BCCH Allocation ARFCN |
GSM 450 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 480 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 710 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
GSM 750 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
T-GSM 810 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
GSM 850 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 900 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
DCS 1 800 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
PCS 1 900 |
Range 128 |
129, 135, 141, 147, 153, 159, 165, 171 |
SYSTEM INFORMATION TYPE 3:
as default except:
Information Element |
value/remark |
SI 3 rest octets |
|
– SI 2ter indicator |
System Information 2ter is available |
– Early Classmark Sending Control |
Early Sending is explicitly accepted |
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Descriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format Identifier |
See table below |
– BCCH Allocation Sequence |
1 |
– BCCH Allocation ARFCN |
See table below |
– EXT IND |
Information Element carries the complete BA. |
Band |
Format |
BCCH Allocation ARFCN |
GSM 450 |
Range 128 |
260, 264, 268, 272, 276, 280, 284 , 288 |
GSM 480 |
Range 128 |
307, 311, 315, 319, 323, 327, 331 , 335 |
GSM 710 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 750 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
T-GSM 810 |
Range 128 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 850 |
Range 128 |
129, 135, 141, 147, 153, 159, 165 , 171 |
GSM 900 |
Bitmap 0 |
2, 8, 14, 20, 26, 32, 38, 44 |
DCS 1 800 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
PCS 1 900 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
SYSTEM INFORMATION TYPE 5ter:
Information Element |
value/remark |
Protocol Descriminator |
RR management |
Message Type |
Sys Info 5ter. |
Additional Multiband information |
|
– Multiband reporting |
Minimum 2 cells reported from each band supported excluding the frequency band of the serving cell. |
Extension of the BCCH Frequency list |
|
– Format identifier |
See table below |
– BCCH Allocation Sequence |
1 |
– BCCH Allocation ARFCN |
See table below |
Band |
Format Identifier |
BCCH Allocation ARFCN |
GSM 450 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 480 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 710 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
GSM 750 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
T-GSM 810 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
GSM 850 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
GSM 900 |
Range 512 |
514, 530, 549, 602, 665, 686, 762, 810 |
DCS 1 800 |
Range 1 024 |
2, 8, 14, 20, 26, 32, 38, 44 |
PCS 1 900 |
Range 128 |
129, 135, 141, 147, 153, 159, 165, 171 |
MEASUREMENT REPORT:
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 3 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
6 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 1 |
BCCH_FREQ_NCELL_1 |
See note 2 |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 1 |
BCCH_FREQ_NCELL_2 |
See note 2 |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
See note 1 |
BCCH_FREQ_NCELL_3 |
See note 2 |
BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
RXLEV_NCELL_4 |
See note 1 |
BCCH_FREQ_NCELL_4 |
See note 2 |
BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
RXLEV_NCELL_5 |
See note 1 |
BCCH_FREQ_NCELL_5 |
See note 2 |
BSIC_NCELL_5 |
Corresponds to that of BCCH_FREQ_NCELL_5 |
RXLEV_NCELL_6 |
See note 1 |
BCCH_FREQ_NCELL_6 |
See note 2 |
BSIC_NCELL_6 |
Corresponds to that of BCCH_FREQ_NCELL_6 |
NOTE 1: These actual values are not checked. NOTE 2: report on ARFCNs See table below. NOTE 3: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE. |
Band |
ARFCNS |
GSM 450 |
260, 272, 276, 280, 284 and 288 |
GSM 480 |
307, 319, 323, 327, 331 and 335 |
GSM 710 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 750 |
439, 445, 451, 457, 463, 469, 475, 481 |
T-GSM 810 |
439, 445, 451, 457, 463, 469, 475, 481 |
GSM 850 |
129, 147, 153, 159, 165 and 171 |
GSM 900 |
2, 20, 26, 32, 38 and 44 |
DCS 1 800 |
514, 549, 665, 686, 762, 810 |
PCS 1 900 |
514, 549, 665, 686, 762, 810 |
26.6.3.7 Measurement / new cell reporting
26.6.3.7.1 Conformance requirements
The MS shall continuously send MEASUREMENT REPORT messages on every SACCH blocks and the measurement valid indication shall be set to valid (0) within the second block at the latest. The MS shall report a new strongest cell in the measurement report at the latest 5 s after a new strongest cell (which is part of the BA(SACCH)) has been activated under the following network conditions: Initial serving cell at RXLEV= -70 dBm, with 6 neighbours at RXLEV= -75 dBm. Then the new BCCH carrier is switched on at RXLEV= -60 dBm.
NOTE: Because of test equipment limitations it is acceptable to activate the new carrier to replace one of the 6 neighbours.
References
3GPP TS 04.08 / 3GPP TS 44.018 subclause 3.4.1.2, 3GPP TS 05.08 subclause 7.2.
26.6.3.7.2 Test purpose
To test that, when the SS activates a new strongest neighbour cell, the MS reports that cell with a maximum delay of 5 s.
26.6.3.7.3 Method of test
Initial Conditions
System Simulator:
7 cells with the following settings:
Transmitter |
||||||||
Serving |
Neighbour |
|||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
||
Level |
-70 |
-75 |
-75 |
-75 |
-75 |
-75 |
-75 |
|
NCC |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
BCC |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
With the exception of the Cell Allocation, the rest of the parameters for all seven cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A. The Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells need have only one entry, consisting of the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
The test is performed in two steps a) and b).
Step a)
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5 & 6 on the SACCH. All 7 of the BCCHs "on air" are indicated in the BA. The MS shall send MEASUREMENT REPORTs back to the SS, and it shall be indicated within 20 s in these that measurement results for the 6 strongest carriers have been obtained.
Step b)
The SS replaces neighbour cell N1 with neighbour cell N7 with a signal strenght of –60 dBm, in order to have the following new settings:
Transmitter |
||||||||
Serving |
Neighbour |
|||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
||
Level |
-70 |
-60 |
-75 |
-75 |
-75 |
-75 |
-75 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
1 |
7 |
1 |
3 |
5 |
7 |
|
ARFCN |
GSM 450 |
260 |
288 |
268 |
272 |
276 |
280 |
284 |
GSM 480 |
307 |
335 |
315 |
319 |
323 |
327 |
331 |
|
GSM 710 |
439 |
481 |
451 |
457 |
463 |
469 |
475 |
|
GSM 750 |
439 |
481 |
451 |
457 |
463 |
469 |
475 |
|
T-GSM 810 |
439 |
481 |
451 |
457 |
463 |
469 |
475 |
|
GSM 850 |
129 |
162 |
141 |
147 |
153 |
159 |
165 |
|
GSM 900 |
002 |
044 |
014 |
020 |
026 |
032 |
038 |
|
DCS 1 800 |
514 |
810 |
602 |
665 |
762 |
686 |
549 |
|
PCS 1 900 |
514 |
810 |
602 |
665 |
762 |
686 |
549 |
|
Cell Identity |
0001H |
0008H |
0003H |
0004H |
0005H |
0006H |
0007H |
With a maximum delay of 5 s, the neighbour cell N7 is included in the measurement report messages.
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
Since SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT REPORT are sent continuously, a table is not applicable in this test. The interval between 2 successive Layer 2 frames containing MEASUREMENT REPORTs shall not exceed one Layer 2 frame.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
– Format |
See table below |
– BCCH Allocation Sequence |
1 |
– EXT IND |
Information Element carries complete BA. |
– BCCH Allocation ARFCN |
See table below |
Band |
BCCH Allocation ARFCNs |
Format |
GSM 450 |
259, 261, 262, 263, 264, 265, 267, 268, 269, 270, 271, 272, 273, 274, 275, 276, 278, 279, 280, 281, 282, 283, 284, 285, 286, 287, 288, 289, 290, 291, 292 |
Variable bitmap |
GSM 480 |
306, 308, 309, 310, 311, 312, 314, 315, 316, 317, 318, 319, 320, 321, 322, 323, 325, 326, 327, 328, 329, 330, 331, 332, 333, 334, 335, 336, 337, 338, 339 |
Variable bitmap |
GSM 710 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472 and 475 |
Range 128 |
GSM 750 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472 and 475 |
Range 128 |
T-GSM 810 |
439, 441, 442, 443, 444, 445, 446, 447, 448, 449, 450,451, 453, 454, 455, 456, 457, 458, 459, 460, 461, 463, 465, 466, 467, 469, 471, 472 and 475 |
Range 128 |
GSM 850 |
129, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 143, 144, 145, 146, 147, 148, 149, 150, 151, 153, 155, 156, 157, 159, 161, 162 and 165 |
Range 128 |
GSM 900 |
2, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 16, 17, 18, 19, 20, 21, 22, 23, 24, 26, 28, 29, 30, 32, 34, 35, 36, 38, 40, 44 |
Bitmap 0 |
DCS 1 800 |
514, 530, 549, 602, 665, 686, 762, 810. |
Range 1 024 |
PCS 1 900 |
514, 530, 549, 602, 665, 686, 762, 810. |
Range 1 024 |
DCS 1 800 or PCS 1 900 begin:
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio_Link_Timeout |
default |
PLMN permitted |
only NCC 1 permitted |
DCS 1 800 or PCS 1 900 end:
MEASUREMENT REPORT: Step a)
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 2 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
6 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 1 |
BCCH_FREQ_NCELL_1 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 1 |
BCCH_FREQ_NCELL_2 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
See note 1 |
BCCH_FREQ_NCELL_3 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
RXLEV_NCELL_4 |
See note 1 |
BCCH_FREQ_NCELL_4 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
RXLEV_NCELL_5 |
See note 1 |
BCCH_FREQ_NCELL_5 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_5 |
Corresponds to that of BCCH_FREQ_NCELL_5 |
RXLEV_NCELL_6 |
See note 1 |
BCCH_FREQ_NCELL_6 |
Shall correspond to S1 or N1 or N2 or N3 or N4 or N5 or N6 |
BSIC_NCELL_6 |
Corresponds to that of BCCH_FREQ_NCELL_6 |
MEASUREMENT REPORT: Step b)
Information Element |
value/remark |
Protocol Discriminator |
RR Management |
Transaction Identifier |
0000 |
Message Type |
MEASUREMENT REPORT |
Measurement Results |
|
BA_used |
1 |
DTX_used |
DTX was not used |
RXLEV_FULL_SERVING_CELL |
See note 1 |
RXLEV_SUB_SERVING_CELL |
See note 1 |
MEAS_VALID |
See note 2 |
RXQUAL_FULL_SERVING_CELL |
See note 1 |
RXQUAL_SUB_SERVING_CELL |
See note 1 |
NO_NCELL_M |
6 neighbour cell measurement results |
RXLEV_NCELL_1 |
See note 1 |
BCCH_FREQ_NCELL_1 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_1 |
Corresponds to that of BCCH_FREQ_NCELL_1 |
RXLEV_NCELL_2 |
See note 1 |
BCCH_FREQ_NCELL_2 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_2 |
Corresponds to that of BCCH_FREQ_NCELL_2 |
RXLEV_NCELL_3 |
See note 1 |
BCCH_FREQ_NCELL_3 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_3 |
Corresponds to that of BCCH_FREQ_NCELL_3 |
RXLEV_NCELL_4 |
See note 1 |
BCCH_FREQ_NCELL_4 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_4 |
Corresponds to that of BCCH_FREQ_NCELL_4 |
RXLEV_NCELL_5 |
See note 1 |
BCCH_FREQ_NCELL_5 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_5 |
Corresponds to that of BCCH_FREQ_NCELL_5 |
RXLEV_NCELL_6 |
See note 1 |
BCCH_FREQ_NCELL_6 |
Shall correspond to S1 or N2 or N3 or N4 or N5 or N6 or N7 |
BSIC_NCELL_6 |
Corresponds to that of BCCH_FREQ_NCELL_6 |
NOTE 1: These actual values are not checked.
NOTE 2: The Measurement Valid Indication shall be set to valid within the second SACCH block at the latest. When the Indication is set to ‘Not Valid’, then NOTE 1 applies to ALL fields of the Measurement Results IE.
NOTE 3: Cell S1 shall be included in the Measurement Report sent by the MS.
26.6.3.8 Enhanced Measurement /all neighbours present
26.6.3.8.1 Conformance requirements
When in dedicated mode or group transmit mode, the mobile station regularly sends either MEASUREMENT REPORT or ENHANCED MEASUREMENT REPORT messages to the network.
The Mobile Station shall use ENHANCED MEASUREMENT REPORT messages instead of MEASUREMENT REPORT messages if that is indicated by the parameter REPORT_TYPE and if at least one BSIC is allocated to each BA (list) frequency
For Enhanced Measurement Reporting, cells shall be reported if they are among the at least 6 strongest carriers, and BSIC is successfully decoded and valid (see sub-clause 10.1.1) or, if indicated by the parameter INVALID_BSIC_REPORTING, with known and allowed NCC part. The neighbour cells shall be reported according to the priority defined in sub-clause 8.4.8.1. For other radio access technology/mode, RXLEV is replaced by the relevant measurement quantity (see sub-clause 8.1.5);
For report with the ENHANCED MEASUREMENT REPORT message, the Neighbour Cell list is the concatenation of the GSM Neighbour Cell list and the 3G Neighbour Cell list (if any).
References
3GPP TS 04.08 / 3GPP TS 44.018, sub-clause 3.4.1.2; 3.4.1.2.1.3, 3GPP TS 05.08 sub-clause 10.1.4.1
26.6.3.8.2 Test purpose
To test that, when the SS gives information about neighbouring cells, the MS reports appropriate results.
26.6.3.8.3 Method of test
Initial Conditions
System Simulator:
7 cells with the following settings:
Transmitter |
||||||||
Serving |
Neighbour |
|||||||
S1 |
N1 |
N2 |
N3 |
N4 |
N5 |
N6 |
||
Level |
-60 |
-85 |
-80 |
-75 |
-55 |
-50 |
-45 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
5 |
7 |
1 |
3 |
5 |
7 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
280 |
284 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
327 |
331 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
469 |
475 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
159 |
165 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
032 |
038 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
686 |
549 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
0006H |
0007H |
One UTRAN FDD CELL, N7 with following parameters:
UARFCN=10700 (Downlink UE receive, Node B transmit)
Parameter |
Unit |
UTRAN FDD Cell |
CPICH_Ec/Ior |
dB |
-10 |
PCCPCH_Ec/Ior |
dB |
-12 |
SCH_Ec/Ior |
dB |
-12 |
PICH_Ec/Ior |
dB |
-15 |
DPCH_Ec/Ior |
dB |
- |
OCNS |
-0.94 |
|
dB |
10 |
|
dBm/3.84 MHz |
-70 |
|
CPICH_Ec/Io |
dB |
-10.4 |
CPICH RSCP |
dBm |
-70 |
FDD_MULTIRAT_ |
integer |
1 |
Qsearch_P |
integer |
7 (search always) |
3G_SEARCH_PRIO |
integer |
1 |
Propagation Condition |
AWGN |
Reference
TS 45.008 clause 10.1.4.1
Mobile Station
The MS is in the active state of a call (U10).
Specific PICS statements
–
PIXIT statements
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT INFORMATION message on the SACCH. The Report Type parameter on the SACCH indicated ENHANCED MEASUREMENT REPORT. All 7 of the BCCHs "on air" are indicated in the BA and 3G Neighbour Cell Description is indicated in the MEASUREMENT INFORMATION message. The MS shall send ENHANCED MEASUREMENT REPORT back to the SS, and it shall be indicated within 20 s in these that measurement results for the 6 strongest carriers.
Maximum Duration of Test
5 minutes, including 1 minute for any necessary operator actions.
Expected Sequence
Since SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT INFORMATION message are sent continuously on SACCH, a table is not applicable in this test.
Specific Message Contents
SYSTEM INFORMATION TYPE 5:
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Sys Info 5. |
Neighbour Cells Description |
|
Format Identifier |
See Table below |
BCCH Allocation Sequence |
1 |
BCCH Allocation ARFCN |
The channel numbers from the table below belong to the BCCH allocation. |
Band |
BCCH Allocation ARFCNs |
Format Identifier |
GSM 450 |
264, 268, 272, 276, 280, 284 |
Bitmap 0 |
GSM 480 |
311, 315, 319, 323, 327, 331 |
Bitmap 0 |
GSM 710 |
445, 451, 457, 463, 469, 475 |
Bitmap 0 |
GSM 750 |
445, 451, 457, 463, 469, 475 |
Bitmap 0 |
T-GSM 810 |
445, 451, 457, 463, 469, 475 |
Bitmap 0 |
GSM 850 |
135, 141, 147, 153, 159, 165 |
Bitmap 0 |
GSM 900 |
8, 14, 20, 26, 32, 38 |
Bitmap 0 |
DCS 1 800 |
530, 549, 602, 665, 686, 762. |
Range 1 024 |
PCS 1 900 |
530, 549, 602, 665, 686, 762. |
Range 1 024 |
SYSTEM INFORMATION TYPE 6:
Information Element |
value/ remark |
Protocol Discriminator |
RR Management |
Message Type |
sys info 6 |
Cell Identity |
default |
LAI |
default |
Cell Options |
|
– Power Control Indicator |
Power Control Indicator is set |
– DTX Indicator |
MS shall not use DTX |
– Radio_Link_Timeout |
Default |
PLMN permitted |
only NCC 1 permitted |
MEASUREMENT INFORMATION
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Measurement Information (downlink) 00101 |
BA_IND (BCCH Allocation Sequence) |
1 |
3G_BA_IND |
1 |
Report Type |
Enhanced Measurement Report |
REPORT_PRIORITY_Description |
0 |
3G UTRAN FDD Neighbour Cells Description |
|
UARFCN |
10700 |
Absolute_Index_Start_EMR |
6 |
Measurement Parameters |
|
Multi-band Reporting |
0 |
SERVING_BAND_REPORTING |
3 |
SCALE_ORD |
0 |
XXX_REPORTING_THRESHOLD |
1 (priority reporting if rep. value above threshold for 6) |
XXX_REPORTING_OFFSET |
0 (Note 1) |
3G Measurement Parameters |
|
Qsearch_C |
0 |
3G_SEARCH_PRIO |
1 |
FDD_REP_QUANT |
0 (RSCP) |
FDD_MULTIRAT_REPORTING |
1 (one sell) |
FDD_REPORTING_OFFSET |
0 |
FDD_REPORTING_THRESHOLD |
1 (priority reporting if rep. value above threshold for 6) |
ENHANCED MEASUREMENT REPORT:
Information Element |
Value/remark |
Protocol Discriminator |
RR Management |
Message Type |
ENHANCED MEASUREMENT REPORT |
Measurement Results |
|
Serving CELL data |
|
BA_USED |
1 |
3G_BA_USED |
1 |
SCALE |
0 |
BSIC_Seen |
0 |
DTX_used |
DTX was not used |
RXLEV_VAL |
See note 2 |
RX_QUAL_FULL |
100 |
MEAN_BEP |
See note 2 |
CV_BEP |
See note 2 |
NBR_RCVD_BLOCKS |
See note 2 |
Neighbour CELL reporting |
Measurements for the all GSM Cells (including the serving cell) and the UTRAN cell (N7) (Note 2) |
NOTE 1: XXX represent the tested band.
NOTE 2: These actual values are not checked.
26.6.3.9 Enhanced Measurement Report / Measurement Parameters
26.6.3.9.1 Conformance requirements
The BA (list) which is the initial basis for the measurements is derived from information received on the BCCH in System Information 2 and optionally 2bis and/or 2ter and on the SACCH in System Information 5 and optionally 5bis and/or 5ter. MEASUREMENT INFORMATION and SI2quater messages may add information for the GSM Neighbour Cell List and provide 3G Neighbour Cell list. The Mobile Station shall use ENHANCED MEASUREMENT REPORT messages instead of MEASUREMENT REPORT messages if that is indicated by the parameter REPORT_TYPE and if at least one BSIC is allocated to each BA (list) frequency.
The network may request the MS to report serving cell and neighbour cell measurements with Enhanced Measurement Report message by the parameter REPORT_TYPE, provided that BSIC for all GSM neighbour cells has been sent to the MS (See 3GPP TS 44.018). This reporting is referred as Enhanced Measurement Reporting.
The MS shall use the SCALE value as indicated by the parameter SCALE_ORD in the MEASUREMENT INFORMATION. The MS shall indicate the used SCALE value in each individual ENHANCED MEASUREMENT REPORT or PACKET ENHANCED MEASUREMEMT REPORTmessage.
References
3GPP TS 44.018 subclauses 3.2.2.1 and 3.4.1.2
3GPP TS 45.008 subclauses 8.4.8
26.6.3.9.2 Test purpose
To test that the MS reports appropriate results using Enhanced Measurement Report message when REPORT_TYPE is set to 0 in Measurement Information (System Information 2quater respectively).
To verify that an MS, in dedicated mode, use the SCALE value as indicated by the parameter SCALE_ORD in the MEASUREMENT INFORMATION.
26.6.3.9.3 Method of test
Initial Conditions
System Simulator:
5 cells with the following settings:
Transmitter |
||||||
Serving |
Neighbour |
|||||
S1 |
N1 |
N2 |
N3 |
N4 |
||
Level |
-60 |
-85 |
-80 |
-75 |
-55 |
|
Ncc |
1 |
1 |
1 |
1 |
1 |
|
Bcc |
3 |
5 |
7 |
1 |
3 |
|
ARFCN |
GSM 450 |
260 |
264 |
268 |
272 |
276 |
GSM 480 |
307 |
311 |
315 |
319 |
323 |
|
GSM 710 |
439 |
445 |
451 |
457 |
463 |
|
GSM 750 |
439 |
445 |
451 |
457 |
463 |
|
T-GSM 810 |
439 |
445 |
451 |
457 |
463 |
|
GSM 850 |
129 |
135 |
141 |
147 |
153 |
|
GSM 900 |
002 |
008 |
014 |
020 |
026 |
|
DCS 1 800 |
514 |
530 |
602 |
665 |
762 |
|
PCS 1 900 |
514 |
530 |
602 |
665 |
762 |
|
Cell Identity |
0001H |
0002H |
0003H |
0004H |
0005H |
The parameters for all five cells are the same as the default settings and default SYSTEM INFORMATION TYPE 1 to 4 message contents for cell A with the following exceptions:
– the Cell Allocation for the serving cell is the same as the default setting for cell A. The Cell Allocations for the neighbour cells only have one entry for the ARFCN of that cell’s BCCH.
Mobile Station:
The MS is in the active state of a call (U10).
Specific PICS statements:
–
PIXIT statements:
–
Foreseen Final State of the MS
Active state of a call (U10).
Test Procedure
Step a)
With the MS having a call in progress, the SS sends SYSTEM INFORMATION TYPE 5, SYSTEM INFORMATION TYPE 6 and MEASUREMENT INFORMATION messages on the SACCH. The Report Type parameter on the SACCH indicates ENHANCED MEASUREMENT REPORT and SERVING_BAND_REPORTING is set to 3. Serving cell and 4 neighbour cells "on air" are indicated in the BA and no 3G Neighbour Cell Description is indicated in the MEASUREMENT INFORMATION message. The MS shall send ENHANCED MEASUREMENT REPORTs back to the SS, and all carriers present in the BA List shall be indicated within 20 s in these that measurement results.
Step b)
Then the SS sends MEASUREMENT INFORMATION message including the request the use of SCALE_ORD parameter. The MS shall send Enhanced Measurement Report back to the SS and indicate the use of SCALE_ORD parameter. The SS checks that the offset is correctly applied by the MS.
Maximum Duration of Test
5 minutes.
Expected Sequence
Since System Information 5, System Information 6 and Measurement Information are sent on SACCH a table is not applicable in this test.
Specific Message Contents
MEASUREMENT INFORMATION (Step a)
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Measurement Information (downlink) 00101 |
< BA_IND : bit > |
Same BA_IND as for SI5 |
< 3G_BA_IND : bit > |
0 |
< MP_CHANGE_MARK : bit > |
0 |
< MI_INDEX : bit (4) > |
‘0000’B |
< MI_COUNT : bit (4) > |
‘0000’B |
< PWRC : bit > |
0 |
< REPORT_TYPE : bit > |
0 = enhanced |
< REPORTING_RATE : bit > |
0 |
< INVALID_BSIC_REPORTING : bit > |
0 |
0 | 1 < Real Time Difference Description> |
0 |
0 | 1 < BSIC Description>: |
1 |
< BSIC Description struct > |
According to the cells table in Initial Conditions of the test case |
0 | 1 < REPORT PRIORITY Description> |
0 |
0 | 1 < Measurement_Parameters Description > |
1 |
0 | 1 < MULTIBAND_REPORTING > |
0 |
0 | 1 < SERVING_BAND_REPORTING: |
1 |
bit(2) > |
‘11’B |
< SCALE_ORD > |
‘00’B |
0 | 1 < 900_REPORTING_OFFSET > |
0 |
0 | 1 < 1800_REPORTING_OFFSET > |
0 |
0 | 1 < 400_REPORTING_OFFSET > |
0 |
0 | 1 < 1900_REPORTING_OFFSET > |
0 |
0 | 1 < 850_REPORTING_OFFSET > |
0 |
MEASUREMENT INFORMATION (Step b)
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Measurement Information (downlink) 00101 |
< BA_IND : bit > |
Same BA_IND as for SI5 |
< 3G_BA_IND : bit > |
0 |
< MP_CHANGE_MARK : bit > |
1 |
< MI_INDEX : bit (4) > |
‘0000’B |
< MI_COUNT : bit (4) > |
‘0000’B |
< PWRC : bit > |
0 |
< REPORT_TYPE : bit > |
0 = enhanced |
< REPORTING_RATE : bit > |
0 |
< INVALID_BSIC_REPORTING : bit > |
0 |
0 | 1 < Real Time Difference Description> |
0 |
0 | 1 < BSIC Description>: |
1 |
< BSIC Description struct > |
According to the cells table in Initial Conditions of the test case |
0 | 1 < REPORT PRIORITY Description> |
0 |
0 | 1 < Measurement_Parameters Description > |
1 |
0 | 1 < MULTIBAND_REPORTING > |
0 |
0 | 1 < SERVING_BAND_REPORTING: |
1 |
bit(2) > |
‘11’B |
< SCALE_ORD > |
‘01’B |
0 | 1 < 900_REPORTING_OFFSET > |
0 |
0 | 1 < 1800_REPORTING_OFFSET > |
0 |
0 | 1 < 400_REPORTING_OFFSET > |
0 |
0 | 1 < 1900_REPORTING_OFFSET > |
0 |
0 | 1 < 850_REPORTING_OFFSET > |
0 |
ENHANCED MEASUREMENT REPORT (a):
Information Element |
Value/remark |
Protocol Discriminator |
RR Management |
Message Type |
ENHANCED MEASUREMENT REPORT |
< BA_USED > |
0 |
< BSIC_Seen > |
0 |
< SCALE > |
0 |
0 | 1 < Serving cell data : |
1 |
< DTX_USED > |
0 |
Serving Data info |
Content accuracy not checked (Note 1) |
1 <Repeated Invalid_BSIC_Information> |
0 |
0 | 1 < Bitmap Type Reporting Info flag : |
1 |
Reporting Quantity |
RXLEV for all Cells (S1,N1, N2, N3 and N4) present (Note 1) |
ENHANCED MEASUREMENT REPORT (b):
Information Element |
Value/remark |
Protocol Discriminator |
RR Management |
Message Type |
ENHANCED MEASUREMENT REPORT |
< 3G_BA_USED > |
0 |
< BA_USED > |
0 |
< BSIC_Seen > |
0 |
< SCALE > |
1 |
0 | 1 < Serving cell data : |
1 |
< DTX_USED > |
0 |
Serving Data info |
Content accuracy not checked (Note 2) |
1 <Repeated Invalid_BSIC_Information> |
0 |
0 | 1 < Bitmap Type Reporting Info flag: |
1 |
Reporting Quantity |
RXLEV for all Cells (S1, N1, N2, N3 and N4) present (Note 2) |
NOTE 1: The actual values are not checked.
NOTE 2: the RxLev must 10 dB lower than before sending the Measurement Information (b)
26.6.3.10 Enhanced Measurement Report / EMR Reporting after Handover
26.6.3.10.1 Conformance requirements
1. The BA (list) which is the initial basis for the measurements is derived from information received on the BCCH in System Information 2 and optionally 2bis and/or 2ter and on the SACCH in System Information 5 and optionally 5bis and/or 5ter. MEASUREMENT INFORMATION and SI2quater messages may add information for the GSM Neighbour Cell List and provide 3G Neighbour Cell list. The Mobile Station shall use ENHANCED MEASUREMENT REPORT messages instead of MEASUREMENT REPORT messages if that is indicated by the parameter REPORT_TYPE and if at least one BSIC is allocated to each BA (list) frequency
2. When in dedicated mode or group transmit mode, the mobile station regularly sends either MEASUREMENT REPORT or ENHANCED MEASUREMENT REPORT messages to the network. These messages contain measurement results about reception characteristics from the current cell and from neighbour cells.
3. The Mobile Station shall use ENHANCED MEASUREMENT REPORT messages instead of MEASUREMENT REPORT messages if that is indicated by the parameter REPORT_TYPE and if at least one BSIC is allocated to each BA (list) frequency.
References
3GPP TS 44.018 subclauses 3.2.2.1 and 3.4.1.2
3GPP TS 45.008 subclauses 8.4.8
26.6.3.10.2 Test purpose
1. To verify that an MS, in dedicated mode, on a cell A, after receiving a Measurement Information on SACCH with one BSIC allocated to each BA(list) frequency with REPORT_TYPE set to 0 sends ENHANCED MEASUREMENT REPORT.
2. To verify that the MS after switching to a new cell via handover procedure continues to send ENHANCED MEASUREMENT REPORT only after receiving a new Measurement Information.
26.6.3.10.3 Method of test
Initial Conditions
System Simulator:
2 cells, A and B with same LAI default parameters
Mobile Station:
The MS is in the active state of a call (U10)
Specific PICS statements:
–
PIXIT statements:
–
Test Procedure
With the MS having a call in progress on cell A, the SS sends SYSTEM INFORMATION TYPE 5 & 6 on the SACCH.
The SS sends a Measurement Information with Report Type = 0 to trigger the MS to send Enhanced Measurement Report. Measurement results for cell B shall be indicated there.
The MS is handed over to cell B. The MS sends MEAUREMENT REPORT until it receives the MEASUREMENT INFORMATION. The measurement results for cell A shall be indicated.
Maximum Duration of Test
5 minutes.
Expected Sequence
Step |
Direction |
Message |
Comments |
0 |
MS -> SS |
The MS is in the active state of a call on cell A. |
|
1 |
SS -> MS |
MEASUREMENT INFORMATION |
|
2 |
MS -> SS |
ENHANCED MEASUREMENT REPORT |
Measurement results for cell B are present |
3 |
SS -> MS |
HANDOVER COMMAND |
Contains the parameters for cell B |
4 |
MS -> SS |
HANDOVER ACCESS |
Repeated on every burst of the uplink main DCCH (and optionally the SACCH) until reception of PHYSICAL INFORMATION. |
5 |
SS -> MS |
PHYSICAL INFORMATION |
Sent after reception of n HANDOVER ACCESS messages. |
6 |
MS -> SS |
SABM |
Sent without information field. |
7 |
SS -> MS |
UA |
|
8 |
MS -> SS |
HANDOVER COMPLETE |
|
9 |
MS -> SS |
MEASUREMENT REPORT |
|
10 |
SS -> MS |
MEASUREMENT INFORMATION |
|
11 |
MS -> SS |
ENHANCED MEASUREMENT REPORT |
Measurement results for cell A to be reported with in 20 sec of step10. |
Specific Message Contents
MEASUREMENT INFORMATION (Step 1)
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Measurement Information (downlink) 00101 |
< BA_IND : bit > |
Same BA_IND as for SI5 |
< 3G_BA_IND : bit > |
0 |
< MP_CHANGE_MARK : bit > |
0 |
< MI_INDEX : bit (4) > |
‘0000’B |
< MI_COUNT : bit (4) > |
‘0000’B |
< PWRC : bit > |
0 |
< REPORT_TYPE : bit > |
0 = enhanced |
< REPORTING_RATE : bit > |
0 |
< INVALID_BSIC_REPORTING : bit > |
0 |
0 | 1 < Real Time Difference Description> |
0 |
0 | 1 < BSIC Description>: |
1 |
< BSIC Description struct > |
According to the neighbour cells list of cell A |
0 | 1 < REPORT PRIORITY Description> |
0 |
0 | 1 < Measurement_Parameters Description > |
1 |
0 | 1 < MULTIBAND_REPORTING > |
0 |
0 | 1 < SERVING_BAND_REPORTING: |
1 |
bit(2) > |
‘11’B |
< SCALE_ORD > |
‘00’B |
0 | 1 < 900_REPORTING_OFFSET > |
0 |
0 | 1 < 1800_REPORTING_OFFSET > |
0 |
0 | 1 < 400_REPORTING_OFFSET > |
0 |
0 | 1 < 1900_REPORTING_OFFSET > |
0 |
0 | 1 < 850_REPORTING_OFFSET > |
0 |
MEASUREMENT INFORMATION (Step 10)
Information Element |
value/remark |
Protocol Discriminator |
RR management |
Message Type |
Measurement Information (downlink) 00101 |
< BA_IND : bit > |
Same BA_IND as for SI5 |
< 3G_BA_IND : bit > |
0 |
< MP_CHANGE_MARK : bit > |
0 |
< MI_INDEX : bit (4) > |
‘0000’B |
< MI_COUNT : bit (4) > |
‘0000’B |
< PWRC : bit > |
0 |
< REPORT_TYPE : bit > |
0 = enhanced |
< REPORTING_RATE : bit > |
0 |
< INVALID_BSIC_REPORTING : bit > |
0 |
0 | 1 < Real Time Difference Description> |
0 |
0 | 1 < BSIC Description>: |
1 |
< BSIC Description struct > |
According to the neighbour cells list of cell B |
0 | 1 < REPORT PRIORITY Description> |
0 |
0 | 1 < Measurement_Parameters Description > |
1 |
0 | 1 < MULTIBAND_REPORTING > |
0 |
0 | 1 < SERVING_BAND_REPORTING: |
1 |
bit(2) > |
‘11’B |
< SCALE_ORD > |
‘00’B |
0 | 1 < 900_REPORTING_OFFSET > |
0 |
0 | 1 < 1800_REPORTING_OFFSET > |
0 |
0 | 1 < 400_REPORTING_OFFSET > |
0 |
0 | 1 < 1900_REPORTING_OFFSET > |
0 |
0 | 1 < 850_REPORTING_OFFSET > |
0 |