26.11.6 Multiband signalling / Default messages contents

3GPP51.010-1Mobile Station (MS) conformance specificationPart 1: Conformance specificationTS

Default SYSTEM INFORMATION

The following parameters shall be coded into the system information messages. Parameters shall be coded according to 3GPP TS 04.08 / 3GPP TS 44.018.

SYSTEM INFORMATION TYPE 2bis, SYSTEM INFORMATION TYPE 5bis, SYSTEM INFORMATION TYPE 7 and SYSTEM INFORMATION TYPE 8 messages are not used.

For 450/900 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

Range 128

– Cell Allocation ARFCN

ARFCN 263, 267, 275 and 279

For Cell B

– Format identifier

Bit map 0

– Cell Allocation ARFCN

ARFCN 20, 30, 50 and 70

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 263

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 20

For 480/900 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

Range 128

– Cell Allocation ARFCN

ARFCN 310, 315, 322, 326

For Cell B

– Format identifier

Bit map 0

– Cell Allocation ARFCN

ARFCN 20, 30, 50 and 70

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Bit map 0

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 310

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 20

For 450/1 800 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

Range 128

– Cell Allocation ARFCN

ARFCN 263, 267, 275 and 279

For Cell B

– Format identifier

Range 512

– Cell Allocation ARFCN

ARFCN 590, 650, 750 and 850

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 261, 263, 282, 284, 287, 290, 293

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 263

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 590

For 480/1 800 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

Range 128

– Cell Allocation ARFCN

ARFCN 310, 315, 322, 326

For Cell B

– Format identifier

Range 512

– Cell Allocation ARFCN

ARFCN 590, 650, 750 and 850

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Range 128

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 128

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 308, 310, 329, 331, 334, 337, 340

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 310

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 590

For 900/1 800 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

Bit map 0

– Cell Allocation ARFCN

ARFCN 20, 30, 50 and 70

For Cell B

– Format identifier

Range 512

– Cell Allocation ARFCN

ARFCN 590, 650, 750 and 850

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

Bit map 0

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 810 and 870

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 10, 20, 80, 90, 100, 110 and 120

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 20

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 590

For 710/1 900 MS, 750/1 900 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

128 range

– Cell Allocation ARFCN

ARFCN 457, 467, 475 and 497

For Cell B

– Format identifier

Range 512

– Cell Allocation ARFCN

ARFCN 590, 650, 750 and 807

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

128 range

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 447, 457, 480, 499, 504, 507 and 510

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 447, 457, 480, 499, 504, 507 and 510

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

128 range

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 447, 457, 480, 499, 504, 507 and 510

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 447, 457, 480, 499, 504, 507 and 510

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 457

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 590

For 850/1 900 MS:

SYSTEM INFORMATION TYPE 1

Information Element

Value/remark

Cell channel description

For Cell A

– Format identifier

128 range

– Cell Allocation ARFCN

ARFCN 147, 157, 177 and 197

For Cell B

– Format identifier

Range 512

– Cell Allocation ARFCN

ARFCN 590, 650, 750 and 807

RACH control parameters

see below

SI1 rest octets

see below

SYSTEM INFORMATION TYPE 2

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

128 range

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 137, 147, 207, 217, 227, 237 and 247

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

– EXT-IND

"This IE carries the complete BA"

NCC permitted

see below

RACH control parameters

see below

SYSTEM INFORMATION TYPE 2ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 137, 147, 207, 217, 227, 237 and 247

SI 2ter rest octets

see below

SYSTEM INFORMATION TYPE 3

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Control Channel Description

see below

Cell options

see below

Cell selection parameters

see below

RACH control parameters

see below

SI3 rest octets

SI 2ter Indicator

System Information 2ter is available

Early Sending Classmark Control

Early Sending is explicitly accepted

SYSTEM INFORMATION TYPE 4

Information Element

Value/remark

Location Area Identification

see below

Cell selection parameters

see below

RACH control parameters

see below

CBCH Channel Description

see below

CBCH Mobile Allocation

see below

SI4 rest octets

see below

SYSTEM INFORMATION TYPE 5

Information Element

Value/remark

BCCH Frequency list

For Cell A

– Format identifier

128 range

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 137, 147, 207, 217, 227, 237 and 247

– EXT-IND

"The information element carries the complete BA"

For Cell B

– Format identifier

Range 512

– BCCH Allocation Sequence

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

– EXT-IND

This IE carries the complete BA

SYSTEM INFORMATION TYPE 5ter

Information Element

Value/remark

Neighbour Cells Description 2

Multiband reporting

0

For Cell A

– Format notation

Range 512

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 520, 590, 600, 700, 780, 800 and 810

For Cell B

– Format notation

Range 1024

– BA_IND

0

– BCCH Allocation ARFCN

ARFCN 137, 147, 207, 217, 227, 237 and 247

SYSTEM INFORMATION TYPE 6

Information Element

Value/remark

Cell identity

see below

Location Area Identification

see below

Cell options

see below

NCC permitted

see below

Common contents of information elements in SYSTEM INFORMATION TYPE 1 to 6 messages.

CBCH Channel Description

Not present

CBCH Mobile Allocation

Not present

Cell identity

CI VALUE

0001H for cell A, 0002H for cell B

Cell options

Power Control Indicator

power control indicator is not set

DTX Indicator

MS shall not use DTX

RADIO LINK TIME-OUT

8 SACCH blocks

Cell selection parameters

CELL RESELECT HYSTERESIS

12 dB

MS-TXPWR-MAX-CCH

Minimum level

RXLEV-ACCESS-MIN

Minimum level

ACS

There are no additional cell parameters included in SI7 and SI8

NECI

New establishment cause not supported

Control Channel Description

ATT

No Attach/Detach

BS-AG-BLKS-RES

0 blocks reserved

CCCH-CONF

Combined CCCH/SDCCH

BS-PA-MFRMS

5 multiframes

T3212

Infinite

L2 pseudo length

SI 1

21

SI 2

22

SI 2ter

18

SI 3

18

SI 4

12

Location Area Identification

MCC

001 decimal

MNC

01 decimal

LAC

0001H

Message Type

SI 1

00011001

SI 2

00011010

SI 2ter

00000011

SI 3

00011011

SI 4

00011100

SI 5

00011101

SI 5ter

00000110

SI 6

00011110

NCC permitted

00000010

RACH control parameters

MAX RETRANS

Max 1 retrans

TX-INTEGER

5 slots used

CELL BAR ACCESS

Not barred

CALL RE-ESTABLISHMENT

Not Allowed

EMERGENCY CALL

Allowed

ACCESS CONTROL CLASS

None Barred

(0…9, 11…15)

SI 1 rest octets

Not used (all bits are set to spare)

SI 2 rest octets

Not used (all bits are set to spare)

SI 2ter rest octets

Not used (all bits are set to spare)

SI 4 rest octets

Not used (all bits are set to spare)

Default settings for cell A

Downlink input level

63 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 147

Default settings for cell B

Downlink input level

53 dBmicroVolt emf

Uplink output power

Minimum supported by the MS

Propagation profile

Static

BCCH/CCCH

ARFCN 590

Default message contents for other messages

For subclause 26.11.2 Refer to table 26.6

For subclause 26.11.3 same as in subclause 26.7.

For subclause 26.11.4 no tests yet defined.

For subclause 26.11.5 same as in subclause 26.9.7.