8.6 Mobile termination control mode +CMEC

27.0073GPPAT command set for User Equipment (UE)Release 18TS

Table 65: +CMEC parameter command syntax

Command

Possible response(s)

+CMEC=[<keyp>[,<disp>[,<ind>[,<tscrn>]]]

+CME ERROR: <err>

+CMEC?

+CMEC: <keyp>,<disp>,<ind>,<tscrn>

+CMEC=?

+CMEC: (list of supported <keyp>s),(list of supported <disp>s),(list of supported <ind>s),(list of supported <tscrn>s)

Description

Set command selects the equipment, which operates MT keypad, writes to MT display and sets MT indicators. If operation mode is not allowed by the MT, +CME ERROR: <err> is returned. Refer clause 9.2 for possible <err> values.

Read command returns the current settings.

Test command returns the modes supported as compound values.

Defined values

<keyp>: integer type

0 MT can be operated only through its keypad (execute command of +CKPD cannot be used)

1 MT can be operated only from TE (with command +CKPD)

2 MT can be operated from both MT keypad and TE

<disp>: integer type

0 only MT can write to its display (command +CDIS can only be used to read the display)

1 only TE can write to MT display (with command +CDIS)

2 MT display can be written by both MT and TE

<ind>: integer type

0 only MT can set the status of its indicators (command +CIND can only be used to read the indicators)

1 only TE can set the status of MT indicators (with command +CIND)

2 MT indicators can be set by both MT and TE

<tscrn>: integer type

0 only MT can set the status of its indicators (execute command of +CTSA cannot be used)

1 only TE can set the status of MT indicators (with command +CTSA)

2 MT indicators can be set by both MT and TE

Implementation

Mandatory when any of keypad, display or indicator or touch screen commands is implemented.