8.59 Battery capacity +CBCAP

27.0073GPPAT command set for User Equipment (UE)Release 18TS

Table 8.59-1: CBCAP parameter command syntax

Command

Possible response(s)

+CBCAP=[<reporting>[,<reporting_interval>]]

+CBCAP?

+CBCAP: <reporting>,<reporting_interval>,<bcl>

+CBCAP=?

+CBCAP: (list of supported <reporting>s),(list of supported <reporting_interval>s)

Description

Set command enables reporting upon change in battery capacity level, with unsolicited result code +CBCAP: <bcl>. Consecutive reports never show same value of <bcl>.

Read command returns the status of result code presentation and the current battery capacity level.

Test command returns values supported as compound values.

Defined values

<reporting>: integer type. Enables and disables reporting of changes in the battery capacity level.

0 Disable reporting

1 Enable reporting

<reporting_interval>: integer type. Sets the reporting interval of the battery capacity level (in percentages). The default value is manufacturer specific.

1…100 Amount that the remaining battery capacity must change before reporting.

<bcl>: integer type. Gives the remaining relative battery capacity level (in percentages).

0 The battery is exhausted or ME does not have a battery connected

1…100 remaining battery capacity level (in percentages). The provided values are dependant on the parameter <reporting_interval>. A value of 5 for parameter <reporting_interval>, means that the following values of <bcl> are applicable: 0, 5, 10, 15, … , 90, 95, 100.

NOTE: 100% capacity is always reported, even if <reporting_interval> is set to a value where no integer multiple equals 100.

Implementation

Optional.