8.40 Automatic time zone update +CTZU
27.0073GPPAT command set for User Equipment (UE)Release 18TS
Table 100: +CTZU parameter command syntax
Command |
Possible response(s) |
+CTZU=[<onoff>] |
+CME ERROR: <err> |
+CTZU? |
+CTZU: <onoff> +CME ERROR: <err> |
+CTZU=? |
+CTZU: (list of supported <onoff>s) +CME ERROR: <err> |
Description
Set command enables and disables automatic time zone update via NITZ. If setting fails in an MT error, +CME ERROR: <err> is returned. Refer clause 9.2 for possible <err> values.
Read command returns the current settings in the MT.
Test command returns supported on- and off-values as a compound value.
Defined values
<onoff>: integer type value indicating
0 Disable automatic time zone update via NITZ.
1 Enable automatic time zone update via NITZ.
Implementation
Optional.