8.4 Battery charge +CBC
27.0073GPPAT command set for User Equipment (UE)Release 18TS
Table 63: +CBC action command syntax
Command |
Possible response(s) |
+CBC |
+CBC: <bcs>,<bcl> +CME ERROR: <err> |
+CBC=? |
+CBC: (list of supported <bcs>s),(list of supported <bcl>s) |
Description
Execution command returns battery connection status <bcs> and battery charge level <bcl> of the MT. Refer clause 9.2 for possible <err> values.
Test command returns values supported as compound values.
Defined values
<bcs>: integer type
0 MT is powered by the battery
1 MT has a battery connected, but is not powered by it
2 MT does not have a battery connected
3 Recognized power fault, calls inhibited
<bcl>: integer type
0 battery is exhausted, or MT does not have a battery connected
1…100 battery has 1‑100 percent of capacity remaining
Implementation
Optional.