8.4 Battery charge +CBC

27.0073GPPAT command set for User Equipment (UE)Release 18TS

Table 63: +CBC action command syntax

Command

Possible response(s)

+CBC

+CBC: <bcs>,<bcl>

+CME ERROR: <err>

+CBC=?

+CBC: (list of supported <bcs>s),(list of supported <bcl>s)

Description

Execution command returns battery connection status <bcs> and battery charge level <bcl> of the MT. Refer clause 9.2 for possible <err> values.

Test command returns values supported as compound values.

Defined values

<bcs>: integer type

0 MT is powered by the battery

1 MT has a battery connected, but is not powered by it

2 MT does not have a battery connected

3 Recognized power fault, calls inhibited

<bcl>: integer type

0 battery is exhausted, or MT does not have a battery connected

1…100 battery has 1‑100 percent of capacity remaining

Implementation

Optional.