8.34 Ring melody control +CRMC

27.0073GPPAT command set for User Equipment (UE)Release 18TS

Table 94: +CRMC parameter command syntax

Command

Possible response(s)

+CRMC=<index>,<volume>[,[<call type>][,<profile>]]

+CME ERROR: <err>

+CRMC?

+CRMC: <index>,<volume>[,[<call type1>][,<profile1>]]

[<CR><LF>+CRMC: <index>,<volume>[,[<call type2>][,<profile1>]][…]]

[<CR><LF>+CRMC: <index>,<volume>[,[<call type1>][,<profile2>]]]

[<CR><LF>+CRMC: <index>,<volume>[,[<call type2>][,<profile2>]][…]]

+CME ERROR: <err>

+CRMC=?

+CRMC: (list of supported <index>s),(list of supported <volume>s)[,[(list of supported <call type>s)][,(list of supported <profile>s)]]

+CME ERROR: <err>

Description

Write command causes the MT to set a specific ring melody and volume for the selected call type and profile. The default values for the optional parameters are defined by the manufacturer.

Read command queries the settings for the ring melody. If call types and profiles are available, the corresponding ring melodies are listed. Starting with call type1 and profile1 the ring melody settings for each available profile and call type is issued.

Test command returns the list of supported indexes, volumes, call types and profiles as compound values.

Refer clause 9.2 for possible <err> values.

Defined values

<index>: integer type; manufacturer specific number to identify a certain ring melody

<volume>: integer type value with manufacturer specific range (smallest value represents the lowest sound level)

<call typex>: integer type; manufacturer specific number for a call type

<profilex>: integer type; manufacturer specific number for a profile

Implementation

Optional.