8.28 Call meter maximum event +CCWE

27.0073GPPAT command set for User Equipment (UE)Release 18TS

Table 88: +CCWE parameter command syntax

Command

Possible response(s)

+CCWE=[<mode>]

+CME ERROR: <err>

+CCWE?

+CCWE: <mode>

+CME ERROR: <err>

+CCWE=?

+CCWE: (list of supported <mode>s)

+CME ERROR: <err>

Description

Shortly before the ACM (Accumulated Call Meter) maximum value is reached, an unsolicited result code +CCWV will be sent, if enabled by this command. The warning is issued approximately when 30 seconds call time remains. It is also issued when starting a call if less than 30 s call time remains. If setting fails in an MT error, +CME ERROR: <err> is returned. Refer clause 9.2 for possible <err> values.

Read command returns the current setting.

Test command returns supported settings as a compound value.

Defined values

<mode>: integer type

0 Disable the call meter warning event

1 Enable the call meter warning event

Implementation

Optional.