8.20 Alert sound mode +CALM
27.0073GPPAT command set for User Equipment (UE)Release 18TS
Table 80: +CALM parameter command syntax
Command |
Possible response(s) |
+CALM=[<mode>] |
+CME ERROR: <err> |
+CALM? |
+CALM: <mode> +CME ERROR: <err> |
+CALM=? |
+CALM: (list of supported <mode>s) +CME ERROR: <err> |
Description
This command is used to select the general alert sound mode of the MT. Refer clause 9.2 for possible <err> values.
Read command returns the current value of <mode>.
Test command returns supported values as a compound value.
Defined values
<mode>: integer type
0 normal mode
1 silent mode (all sounds from MT are prevented)
2… manufacturer specific
Implementation
Optional.