10.1.65 Indicating the selected PLMN for access to restricted local operator services (RLOS) +CRLOSP
27.0073GPPAT command set for User Equipment (UE)Release 18TS
Table 10.1.65-1: +CRLOSP parameter command syntax
Command |
Possible response(s) |
+CRLOSP=[<n>] |
+CME ERROR: <err> |
+CRLOSP? |
+CRLOSP: <n>[,<RLOS_plmn>] |
+CRLOSP=? |
+CRLOSP: (list of supported <n>s) |
Description
The set command controls the presentation of unsolicited result code +CRLOSPU: <RLOS_plmn> when <n>=1 indicating the PLMN that the UE has selected for access to RLOS.
Refer clause 9.2 for possible <err> values.
The read command returns the current settings of <n> and the currently selected PLMN for access to RLOS (if available).
The test command returns values supported as a compound value.
Defined values
<n>: integer type.
0 Disable presentation of the unsolicited result code +CRLOSPU.
1 Enable presentation of the unsolicited result code +CRLOSPU.
<RLOS_plmn>: string type; indicates the MCC and MNC of the PLMN that the UE has selected for access to RLOS. For the format and the encoding of the MCC and MNC, see 3GPP TS 23.003 [7]. This parameter shall not be subject to conventional character conversion as per +CSCS.
Implementation
Optional. This command is only applicable to UEs in E-UTRAN.