9.2.3 Reporting of Channel Quality Indicator
25.1023GPPRelease 17TSUser Equipment (UE) radio transmission and reception (TDD)
The reporting accuracy of channel quality indicator (CQI) under AWGN and static orthogonal environments is determined by the reporting variance and the BLER performance using the transport format indicated by the reported CQI median.
9.2.3.1 Minimum Requirement-UE categories 1-24
For the parameters specified in Table 9.15, the reported CQI value shall be within +/- x, as specified in Table 9.16, of the reported median CQI for more than Y%, also specified in Table 9.16, of the time.
Table 9.15: Test parameters for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Category 1-3 |
Category 4-6 |
Category 7-9 |
Category 10-12 |
Category 13-15 |
Category 16-18 |
Category 19-21 |
Category 22-24 |
||||||
Parameter |
Unit |
Test 1 |
Test 2 |
Test 3 |
Test 4 |
Test 5 |
Test 6 |
Test 7 |
Test 8 |
Test 9 |
Test 10 |
Test 11 |
Test 12 |
Number of TS |
– |
2 |
2 |
3 |
4 |
5 |
3 |
4 |
5 |
||||
Number of HS-PDSCH codes per TS |
– |
10 |
10 |
10 |
10 |
10 |
14 |
14 |
14 |
||||
HS-PDSCHi_Ec/Ior |
dB |
-10 |
-10 |
-10 |
-10 |
-10 |
-11.46 |
-11.46 |
-11.46 |
||||
HS-PDSCH Channelization Codes* |
C(k,Q) |
C(i,16) 1i10 |
C(i,16) 1i10 |
C(i,16) 1i10 |
C(i,16) 1i10 |
C(i,16) 1i10 |
C(i,16) 1i14 |
C(i,16) 1i14 |
C(i,16) 1i14 |
||||
Number of DPCHo |
– |
0 |
|||||||||||
Number of HARQ Process |
– |
4 |
|||||||||||
Number of transmission |
– |
1 |
|||||||||||
Ioc** |
dBm/1.28MHz |
-60 |
|||||||||||
|
dB |
1 |
1 |
8 |
1 |
8 |
1 |
8 |
1 |
8 |
18 |
18 |
18 |
Propagation Channel |
– |
AWGN |
|||||||||||
*Note 1 Refer to TS 25.223 for definition of channelization codes, scrambling code and basic midamble code. **Note 2 For multi-carrier reception, it refers to |
Table 9.16: Performance requirements for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Test |
Permitted CQI range from median (x) |
% of time that CQI must be within +/- x of median (Y) |
Maximum BLER for median reported CQI |
Test 1 |
+/- 3 |
90 |
10% |
Test 2 |
+/- 3 |
90 |
|
Test 3 |
+/- 2 |
90 |
|
Test 4 |
+/- 2 |
90 |
|
Test 5 |
+/-2 |
90 |
|
Test 6 |
+/-2 |
90 |
|
Test 7 |
+/-2 |
90 |
|
Test 8 |
+/-2 |
90 |
|
Test 9 |
+/-2 |
90 |
|
Test 10 |
+/-2 |
90 |
|
Test 11 |
+/-2 |
90 |
|
Test 12 |
+/-2 |
90 |
9.2.3.2 Minimum Requirement-UE categories 25-27
For the parameters specified in Table 9.16A, the reported CQI value shall be within +/- x, as specified in Table 9.16B, of the reported median CQI for more than Y%, also specified in Table 9.16B, of the time.
The MIMO dual stream static orthogonal propagation conditions are defined in subclause B.3.2.1. For UE supporting Spreading Factor 1 only in dual stream transmission, the number of HS-PDSCH codes per TS should be configured to 1 in dual stream transmission, and the HS-PDSCHi_Ec/Ior should be 0dB.
Table 9.16A: Test parameters for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Category 25 |
Category 26 |
Category 27 |
||||||||
Parameter |
Unit |
Test 1 |
Test 2 |
Test 3 |
Test 4 |
Test 5 |
Test 6 |
|||
Number of TS |
– |
3 |
4 |
5 |
||||||
Number of HS-PDSCH codes per TS |
– |
16 |
16 |
16 |
||||||
Number of HS-PDSCH codes per TS |
– |
16 |
||||||||
HS-PDSCHi_Ec/Ior |
dB |
-12.04 |
||||||||
HS-PDSCH Channelization Codes |
C(k,Q) |
C(i,16) 1i16 |
||||||||
Number of DPCHo |
– |
0 |
||||||||
Number of HARQ Process perstream |
– |
4 |
||||||||
Number of transmission |
– |
1 |
||||||||
Ioc |
dBm |
-60 |
||||||||
|
dB |
8 |
10 |
8 |
10 |
8 |
10 |
|||
Stream Number configuration |
– |
Single Stream |
Dual Stream |
Single Stream |
Dual Stream |
Single Stream |
Dual Stream |
|||
Propagation Channel |
– |
AWGN |
Static Orthogonal |
AWGN |
Static Orthogonal |
AWGN |
Static Orthogonal |
Table 9.16B: Performance requirements for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Test |
Permitted CQI range from median (x) |
% of time that CQI must be within +/- x of median (Y) |
Maximum BLER for median reported CQI |
Test 1 |
+/- 2 |
90 |
10% |
Test 2 |
+/- 2 |
90 |
|
Test 3 |
+/- 2 |
90 |
|
Test 4 |
+/- 2 |
90 |
|
Test 5 |
+/-2 |
90 |
|
Test 6 |
+/-2 |
90 |
9.2.3.3 Minimum Requirement-UE categories 28-30
For the parameters specified in Table 9.16C, the reported CQI value shall be within +/- x, as specified in Table 9.16D, of the reported median CQI for more than Y%, also specified in Table 9.16D, of the time.
The MIMO dual stream static orthogonal propagation conditions are defined in subclause B.3.2.1. For UE supporting Spreading Factor 1 only in dual stream transmission, the number of HS-PDSCH codes per TS should be configured to 1 in dual stream transmission, and the HS-PDSCHi_Ec/Ior should be 0dB.
Table 9.16C: Test parameters for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Category 28 |
Category 29 |
Category 30 |
||||||||
Parameter |
Unit |
Test 1 |
Test 2 |
Test 3 |
Test 4 |
Test 5 |
Test 6 |
|||
Number of TS |
– |
3 |
4 |
5 |
||||||
Number of HS-PDSCH codes per TS |
– |
16 |
16 |
16 |
||||||
Number of HS-PDSCH codes per TS |
– |
16 |
||||||||
HS-PDSCHi_Ec/Ior |
dB |
-12.04 |
||||||||
HS-PDSCH Channelization Codes |
C(k,Q) |
C(i,16) 1i16 |
||||||||
Number of DPCHo |
– |
0 |
||||||||
Number of HARQ Process perstream |
– |
4 |
||||||||
Number of transmission |
– |
1 |
||||||||
Ioc |
dBm |
-60 |
||||||||
|
dB |
16 |
18 |
16 |
18 |
16 |
18 |
|||
Stream Number |
– |
Single Stream |
Dual Stream |
Single Stream |
Dual Stream |
Single Stream |
Dual Stream |
|||
Propagation Channel |
– |
AWGN |
Static Orthogonal |
AWGN |
Static Orthogonal |
AWGN |
Static Orthogonal |
Table 9.16D: Performance requirements for CQI reporting measurement channel requirements (1.28 Mcps TDD Option)
Test |
Permitted CQI range from median (x) |
% of time that CQI must be within +/- x of median (Y) |
Maximum BLER for median reported CQI |
Test 1 |
+/- 2 |
90 |
10% |
Test 2 |
+/- 2 |
90 |
|
Test 3 |
+/- 2 |
90 |
|
Test 4 |
+/- 2 |
90 |
|
Test 5 |
+/- 2 |
90 |
|
Test 6 |
+/- 2 |
90 |