8.6 Uplink Power Control for 3.84 Mcps TDD Option

25.1023GPPRelease 17TSUser Equipment (UE) radio transmission and reception (TDD)

Power control in the uplink is the ability of the UE to converge to the required link quality set by the network while using minimum uplink power.

8.6.1 Test Conditions

During period T1, the PCCPCH and a second Beacon Channel are transmitted in the DL in designated slots within each frame and at the same power level.

The UE transmits, using the channel of TS25.105, Annex A.2.1 UL reference measurement channel (12.2 kbps) in one UL slot. For different parts of the test, different UL slots will be designated.

The values of table 8.14, period T1 shall be selected. Then, with the received PCCPCH and Beacon power set at -60 dBm, the value of DPCH constant value shall be adjusted so that the mean UE output power is 5 dBm. These conditions are held steady during period T1.

Periods T1 and T2 are each 5 seconds long.

Table 8.14: UL Power Control Test Conditions

Period T1

Period T2

IBTS all slots

dBm

-60

PCCPCH Power -Broadcast

dBm

18

PCCPCH power – Received

dBm

-60

-70

Mean UE transmit power

dBm

5

According to tables 8.15 and 8.16

SIRTARGET

dB

6

Ioc in PCCPCH and Beacon Slots

dBm

-60

IE (information element) Alpha

As defined in 25.331

1.0

PCCPCH slot position

Integer 0 -14

0

Beacon slot position

Integer 0-14

8

Figure 8.1

8.6.2 Performance

At the end of period T1, the PCCPCH and Beacon Received power shall be simultaneously decreased by 10 dB. These conditions are summarized in table 8.14, period T2.

For the first frame including the change in received power the UE output power shall satisfy the values in table 8.15.

For the 20th frame after the change in received power the UE output power shall satisfy the values in table 8.16.

Table 8.15: Required UE Output Power, Frame Containing Power Level Change

Parameter

Units

Value

UL transmission slot position

1,9

7,14

UE output power

dBm

15 ±4.0

5 ±0.5

Table 8.16: Required UE Output Power, 20 Frames after Power Level Change

Parameter

Units

Value

UL transmission slot position

1,9

7,14

UE output power

dBm

15 ±4.0

15 ±4.0