A.4A Reference parameters for discontinuous UL DPCCH transmission
25.1013GPPRelease 17TSUser Equipment (UE) radio transmission and reception (FDD)
The parameters for the UE UL power control operation with discontinuous UL DPCCH transmission test is specified in Table A.20A. Same parameter values are used for 2ms and 10ms E-DCH TTI.
Table A.20A: Parameters for the discontinuous UL DPCCH transmission
Parameter |
Unit |
Level |
Enabling_Delay |
Radio frames |
0 |
UE_DTX_cycle_1 |
Subframes |
10 |
UE_DTX_cycle_2 |
Subframes |
10 |
UE_DTX_DRX_offset |
Subframes |
0 |
Inactivity_threshold_for_UE_DTX_cycle2 |
E-DCH TTI |
1 |
UE_DPCCH_burst_1 |
Subframes |
1 |
UE_DPCCH_burst_2 |
Subframes |
1 |
UE_DTX_long_preamble_length |
Slots |
2 |
CQI Feedback cycle, k |
Milliseconds |
0 |
CQI_DTX_TIMER |
Subframes |
0 |
Table A.20B: (void)
Figure A.11A (void)