The parameters for the UE UL power control operation with discontinuous UL DPCCH transmission test is specified in Table A.20A. Same parameter values are used for 2ms and 10ms E-DCH TTI.

Table A.20A: Parameters for the discontinuous UL DPCCH transmission

Parameter

Unit

Level

Enabling_Delay

Radio frames

0

UE_DTX_cycle_1

Subframes

10

UE_DTX_cycle_2

Subframes

10

UE_DTX_DRX_offset

Subframes

0

Inactivity_threshold_for_UE_DTX_cycle2

E-DCH TTI

1

UE_DPCCH_burst_1

Subframes

1

UE_DPCCH_burst_2

Subframes

1

UE_DTX_long_preamble_length

Slots

2

CQI Feedback cycle, k

Milliseconds

0

CQI_DTX_TIMER

Subframes

0

Table A.20B: (void)