8.8 Power control in downlink

25.1013GPPRelease 17TSUser Equipment (UE) radio transmission and reception (FDD)

Power control in the downlink is the ability of the UE receiver to converge to required link quality set by the network while using as low power as possible in downlink . If a BLER target has been assigned to a DCCH (See Annex A.3), then it has to be such that outer loop is based on DTCH and not on DCCH.

The requirements in this subclause were derived with the assumption that the UTRAN responds immediately to the uplink TPC commands by adjusting the power of the first pilot field of the DL DPCCH that commences after end of the received TPC command.

8.8.1 Power control in the downlink, constant BLER target

8.8.1.1 Minimum requirements

For the parameters specified in Table 8.29 the downlink power ratio measured values, which are averaged over one slot, shall be below the specified value in Table 8.30 more than 90% of the time. BLER shall be as shown in Table 8.30. If the UE supports optional enhanced performance requirements type1 for DCH then for the parameters specified in Table 8.30A the downlink power ratio measured values, which are averaged over one slot, shall be below the specified value in Table 8.30B more than 90% of the time. BLER shall be as shown in Table 8.30B and Test 2 shall be replaced by Test 2a. Power control in downlink is ON during the test.

Table 8.29: Test parameter for downlink power control

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

9

-1

4

9

dBm/3.84 MHz

-60

-60

Information Data Rate

kbps

12.2

64

Reference channel in Annex A

A.3.1

A.3.5

Target quality value on DTCH

BLER

0.01

0.1

0.001

Target quality value on DCCH

BLER

0.1

0.1

Propagation condition

Case 4

Maximum_DL_Power *

dB

7

Minimum_DL_Power *

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

NOTE: Power is compared to P-CPICH as specified in [4].

Table 8.30: Requirements in downlink power control

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

-16.0

-9.0

-9.0

-10.3

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

0.1±30%

0.001±30%

Table 8.30A: Test parameter for downlink power control for UE supporting the enhanced performance requirements type1 for DCH

Parameter

Unit

Test 2a

dB

-1

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

Reference channel in Annex A

A.3.1

Target quality value on DTCH

BLER

0.01

Target quality value on DCCH

BLER

Propagation condition

PA3

Maximum_DL_Power *

dB

7

Minimum_DL_Power *

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

NOTE: Power is compared to P-CPICH as specified in [4].

Table 8.30B: Requirements in downlink power control for UE supporting the enhanced performance requirements type1 for DCH

Parameter

Unit

Test 2a

dB

-12.2

Measured quality on DTCH

BLER

0.01±30%

8.8.1A Power control in the downlink, constant BLER target when DL_DCH_FET_Config [10] is configured by higher layers

8.8.1A.1 Minimum requirements

For the parameters specified in Table 8.30C and Table 8.30D, the downlink power ratio measured values, which are averaged over one slot, shall be below the specified value in Table 8.30E, Table 8.30F, Table 8.30G and Table 8.30H more than 90% of the time. BLER shall be as shown inTable 8.30E, Table 8.30F, Table 8.30G and Table 8.30H. Test requirements in Table 8.30E, Table 8.30F, Table 8.30G and Table 8.30H correspond to DL_DCH_FET_Config is set to 0 with UL in 20ms transmission mode, DL_DCH_FET_Config is set to 0 with UL in 10ms transmission mode, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and non-Null transmission in the UL, and, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and Null transmission in the UL respectively.

Table 8.30C: Test parameter for downlink power control

Parameter

Unit

Test 1

Test 2

dB

9

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

0

Reference channel in Annex A

A.3A.2

A.3A.0

Target quality value on DTCH

BLER

0.01

Target quality value on DCCH

BLER

Propagation condition

Case 4

Maximum_DL_Power *

dB

7

Minimum_DL_Power *

dB

-18

-21

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Table 8.30D: Test parameter for downlink power control

Parameter

Unit

Test 3

Test 4

dB

-1

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

0

Reference channel in Annex A

A.3A.2

A.3A.0

Target quality value on DTCH

BLER

0.01

Target quality value on DCCH

BLER

Propagation condition

Case 4

Maximum_DL_Power *

dB

7

Minimum_DL_Power *

dB

-18

-21

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

NOTE: Power is compared to P-CPICH as specified in [4].

Table 8.30E: Requirements in downlink power control (DL_DCH_FET_Config is set to 0 with 20ms UL transmission mode)

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

-17.7

-19.8

-10.2

-11.7

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

0.01±30%

0.01±30%

Table 8.30F: Requirements in downlink power control (DL_DCH_FET_Config is set to 0 with 10ms UL transmission mode)

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

-14.4

-16.5

-6.0

-8.7

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

0.01±30%

0.01±30%

Table 8.30G: Requirements in downlink power control (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode)

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

-17.5

-19.8

-9.6

-11.6

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

0.01±30%

0.01±30%

Table 8.30H: Requirements in downlink power control (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode and Null transmission in uplink)

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

dB

-17.5

-19.7

-9.6

-11.6

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

0.01±30%

0.01±30%

8.8.2 Power control in the downlink, initial convergence

This requirement verifies that DL power control works properly during the first seconds after DPCH connection is established

8.8.2.1 Minimum requirements

For the parameters specified in Table 8.31 the downlink DPCH_Ec/Ior power ratio measured values, which are averaged over 50 ms, shall be within the range specified in Table 8.32 more than 90% of the time. For UE supporting the enhanced performance requirements type1 for DCH with the parameters specified in Table 8.32A the downlink DPCH_Ec/Ior power ratio measured values, which are averaged over 50 ms, shall be within the range specified in Table 8.32B more than 90% of the time. T1 equals to 500 ms and it starts 10 ms after the DPDCH physical channel is considered established and the first uplink frame is transmitted. T2 equals to 500 ms and it starts when T1 has expired. Power control is ON during the test. If the UE supports optional enhanced performance requirements type1 for DCH, Test 1, Test 2, Test 3 and Test 4 shall be replaced by Test 1a, Test 2a, Test 3a and Test 4a.

The first 10 ms shall not be used for averaging, ie the first sample to be input to the averaging filter is at the beginning of T1. The averaging shall be performed with a sliding rectangular window averaging filter. The window size of the averaging filter is linearly increased from 0 up to 50 ms during the first 50 ms of T1, and then kept equal to 50ms.

Table 8.31: Test parameters for downlink power control

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

Target quality value on DTCH

BLER

0.01

0.01

0.1

0.1

Initial DPCH_Ec/Ior

dB

-5.9

-25.9

-3

-22.8

Information Data Rate

kbps

12.2

12.2

64

64

dB

-1

dBm/3.84 MHz

-60

Propagation condition

Static

Maximum_DL_Power

dB

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Table 8.32: Requirements in downlink power control

Parameter

Unit

Test 1 and Test 2

Test 3 and Test 4

during T1

dB

-18.9 ≤ DPCH_Ec/Ior ≤ -11.9

-15.1 ≤ DPCH_Ec/Ior ≤ -8.1

during T2

dB

-18.9 ≤ DPCH_Ec/Ior ≤ -14.9

-15.1 ≤ DPCH_Ec/Ior ≤ -11.1

Note: The lower limit is decreased by 3 dB for a UE with more than one antenna connector.

Table 8.32A: Test parameters for downlink power control for UE supporting the enhanced performance requirements type1 for DCH

Parameter

Unit

Test 1a

Test 2a

Test 3a

Test 4a

Target quality value on DTCH

BLER

0.01

0.01

0.1

0.1

Initial DPCH_Ec/Ior

dB

-8.9

-28

-6

-25.8

Information Data Rate

kbps

12.2

12.2

64

64

dB

-1

dBm/3.84 MHz

-60

Propagation condition

Static

Maximum_DL_Power

dB

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Table 8.32B: Requirements in downlink power control for UE supporting the enhanced performance requirements type1 for DCH

Parameter

Unit

Test 1a and Test 2a

Test 3a and Test 4a

during T1

dB

-21.9 ≤ DPCH_Ec/Ior ≤ -14.9

-18.1 ≤ DPCH_Ec/Ior ≤ -11.1

during T2

dB

-21.9 ≤ DPCH_Ec/Ior ≤ -17.9

-18.1 ≤ DPCH_Ec/Ior ≤ -14.1

8.8.2A Power control in the downlink, initial convergence when DL_DCH_FET_Config [10] is configured by higher layers

This requirement verifies that DL power control works properly during the first seconds after DPCH connection is established.

8.8.2A.1 Minimum requirements

For the parameters specified in Table 8.32C the downlink DPCH_Ec/Ior power ratio measured values, which are averaged over 50 ms, shall be within the range specified in Table 8.32D, Table 8.32E and Table 8.32F more than 90% of the time. T1 equals to 500 ms and it starts 10 ms after the DPDCH physical channel is considered established and the first uplink frame is transmitted. T2 equals to 500 ms and it starts when T1 has expired. Power control is ON during the test.

The first 10 ms shall not be used for averaging, ie the first sample to be input to the averaging filter is at the beginning of T1. The averaging shall be performed with a sliding rectangular window averaging filter. The window size of the averaging filter is linearly increased from 0 up to 50 ms during the first 50 ms of T1, and then kept equal to 50ms. Test requirements in Table 8.32D, Table 8.32E and Table 8.32F correspond to DL_DCH_FET_Config is set to 0 with UL in 20ms transmission mode, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and non-Null transmission in the UL, and, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and Null transmission in the UL respectively.

Table 8.32C: Test parameters for downlink power control

Parameter

Unit

Test 1

Test 2

Test 3

Test 4

Target quality value on DTCH

BLER

0.01

0.01

Initial DPCH_Ec/Ior

dB

-5.9

-25.9

-5.9

-25.9

Information Data Rate

kbps

12.2

0

DCCH Presence

No

dB

-1

dBm/3.84 MHz

-60

Propagation condition

Static

Maximum_DL_Power

dB

7

Minimum_DL_Power

dB

-18

-21

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Table 8.32D: Requirements in downlink power control (DL_DCH_FET_Config is set to 0 with 20ms UL transmission mode)

Parameter

Unit

Test 1 & Test 2

Test 3 & Test 4

during T1

dB

-20.6 ≤ DPCH_Ec/Ior ≤ -12.0

-20.6 ≤ DPCH_Ec/Ior ≤ -12.0

during T2

dB

-20.6 ≤ DPCH_Ec/Ior ≤ -15.5

-20.6 ≤ DPCH_Ec/Ior ≤ -15.6

Table 8.32E: Requirements in downlink power control (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode)

Parameter

Unit

Test 1 & Test 2

Test 3 & Test 4

during T1

dB

-21.0 ≤ DPCH_Ec/Ior ≤ -11.5

-21.4 ≤ DPCH_Ec/Ior ≤ -11.6

during T2

dB

-21.0 ≤ DPCH_Ec/Ior ≤ -15.8

-21.4 ≤ DPCH_Ec/Ior ≤ -15.2

Table 8.32F: Requirements in downlink power control (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode and Null transmission in uplink)

Parameter

Unit

Test 1 & Test 2

Test 3 & Test 4

during T1

dB

-21.3 ≤ DPCH_Ec/Ior ≤ -10.6

-22.1 ≤ DPCH_Ec/Ior ≤ -11.2

during T2

dB

-21.3 ≤ DPCH_Ec/Ior ≤ -15.0

-22.1 ≤ DPCH_Ec/Ior ≤ -14.9

8.8.3 Power control in downlink, wind up effects

8.8.3.1 Minimum requirements

This test is run in three stages where stage 1 is for convergence of the power control loop. In stage two the maximum downlink power for the dedicated channel is limited not to be higher than the value specified in Table 8.33. All parameters used in the three stages are specified in Table 8.33. The downlink power ratio measured values, which are averaged over one slot, during stage 3 shall be lower than the value specified in Table 8.34 more than 90% of the time.

Power control of the UE is ON during the test.

Table 8.33: Test parameter for downlink power control, wind-up effects

Parameter

Unit

Test 1

Stage 1

Stage 2

Stage 3

Time in each stage

s

5

5

0.5

dB

5

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

Quality target on DTCH

BLER

0.01

Propagation condition

Case 4

Maximum_DL_Power

dB

7

min(-6.2,P). Note 1

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Note 1: P is the level corresponding to the average power ratio – 2 dB compared to the P-CPICH level. The average power ratio is measured during the initialisation stage after the power control loop has converged before the actual test starts.

Table 8.34: Requirements in downlink power control, wind-up effects

Parameter

Unit

Test 1, stage 3

dB

-13.3

8.8.3A Power control in downlink, wind up effects when DL_DCH_FET_Config [10] is configured by higher layers

8.8.3A.1 Minimum requirements

This test is run in three stages where stage 1 is for convergence of the power control loop. In stage two the maximum downlink power for the dedicated channel is limited not to be higher than the value specified in Table 8.33A and Table 8.33B. All parameters used in the three stages are specified in Table 8.33A and Table 8.33B. The downlink power ratio measured values, which are averaged over one slot, during stage 3 shall be lower than the value specified in Table 8.34C, Table 8.34D, Table 8.34E and Table 8.34F more than 90% of the time. Test requirements in Table 8.34C, Table 8.34D, Table 8.34E and Table 8.34F correspond to DL_DCH_FET_Config is set to 0 with UL in 20ms transmission mode, DL_DCH_FET_Config is set to 0 with UL in 10ms transmission mode, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and non-Null transmission in the UL, and, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and Null transmission in the UL respectively.

Power control of the UE is ON during the test.

Table 8.34A: Test parameter for downlink power control, wind-up effects (12.2 kbps without DCCH)

Parameter

Unit

Test 1

Stage 1

Stage 2

Stage 3

Time in each stage

s

5

5

0.5

dB

5

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

DCCH Presence

No

Quality target on DTCH

BLER

0.01

Propagation condition

Case 4

Maximum_DL_Power

dB

7

min(-6.2,P). Note 1

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Note 1: P is the level corresponding to the average power ratio – 2 dB compared to the P-CPICH level. The average power ratio is measured during the initialisation stage after the power control loop has converged before the actual test starts.

Table 8.34B: Test parameter for downlink power control, wind-up effects (0 kbps without DCCH)

Parameter

Unit

Test 1

Stage 1

Stage 2

Stage 3

Time in each stage

s

5

5

0.5

dB

5

dBm/3.84 MHz

-60

Information Data Rate

kbps

0

DCCH Presence

No

Quality target on DTCH

BLER

0.01

Propagation condition

Case 4

Maximum_DL_Power

dB

7

min(-6.2,P). Note 1

7

Minimum_DL_Power

dB

-21

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Note 1: P is the level corresponding to the average power ratio – 2 dB compared to the P-CPICH level. The average power ratio is measured during the initialisation stage after the power control loop has converged before the actual test starts.

Table 8.34C: Requirements in downlink power control, wind-up effects (DL_DCH_FET_Config is set to 0 with 20ms UL transmission mode)

Parameter

Unit

Test 1, stage 3

Reference Measurement Channel (A.3A.2)

Test 1, stage 3

Reference Measurement Channel (A.3A.0)

dB

-14.6

-17.3

Table 8.34D: Requirements in downlink power control, wind-up effects (DL_DCH_FET_Config is set to 0 with 10ms UL transmission mode)

Parameter

Unit

Test 1, stage 3

Reference Measurement Channel (A.3A.2)

Test 1, stage 3

Reference Measurement Channel (A.3A.0)

dB

-13.6

-15.7

Table 8.34E: Requirements in downlink power control, wind-up effects (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode)

Parameter

Unit

Test 1, stage 3

Reference Measurement Channel (A.3A.2)

Test 1, stage 3

Reference Measurement Channel (A.3A.0)

dB

-14.7

-17.1

Table 8.34F: Requirements in downlink power control, wind-up effects (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode and Null transmission in Uplink)

Parameter

Unit

Test 1, stage 3

Reference Measurement Channel (A.3A.2)

Test 1, stage 3

Reference Measurement Channel (A.3A.0)

dB

-14.7

-16.7

8.8.4 Power control in the downlink, different transport formats

8.8.4.1 Minimum requirements

Test 1 verifies that UE outer loop power control has proper behaviour with different transport formats.

The downlink reference measurement channel used in this subclause shall have two different transport formats. The different transport formats of the downlink reference measurement channel used shall correspond to the measurement channels specified in Annex A.3.0 and A.3.1. The transport format used in downlink reference measurement channel during different stages of the test shall be set according to the information data rates specified in Table 8.34A. During stage 1 a downlink transport format combination using the 12.2kbps information data rate DTCH shall be used, and during stage 2 the downlink transport format combination shall be changed such that a 0kbps information data rate transport format combination is then used.

For the parameters specified in Table 8.34A the downlink power ratio measured values, which are averaged over one slot, shall be below the specified value in Table 8.34B more than 90% of the time. BLER shall be as shown in Table 8.34B. Power control in downlink is ON during the test.

Table 8.34A: Parameters for downlink power control in case of different transport formats

Parameter

Unit

Test 1

Stage 1

Stage 2

Time in each stage

s

Note 1

Note 1

dB

9

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

0

Quality target on DTCH

BLER

0.01

Quality target on DCCH

BLER

1

Propagation condition

Case4

Maximum_DL_Power

dB

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Note 1: The stage lasts until the DTCH quality has converged to the quality target

NOTE: Power is compared to P-CPICH as specified in [4].

Table 8.34B: Requirements in downlink power control in case of different transport formats

Parameter

Unit

Test 1, stage 1

Test 1, stage 2

dB

-16.0

-18.0

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

8.8.4A Power control in the downlink, different transport formats

8.8.4A.1 Minimum requirements

Test 1 verifies that UE outer loop power control has proper behaviour with different transport formats.

The downlink reference measurement channel used in this subclause shall have two different transport formats. The different transport formats of the downlink reference measurement channel used shall correspond to the measurement channels specified in Annex A.3A.0 and A.3A.2. The transport format used in downlink reference measurement channel during different stages of the test shall be set according to the information data rates specified in Table 8.34BA. During stage 1 a downlink transport format combination using the 12.2kbps information data rate DTCH shall be used, and during stage 2 the downlink transport format combination shall be changed such that a 0kbps information data rate transport format combination is then used.

For the parameters specified in Table 8.34BA, the downlink power ratio measured values, which are averaged over one slot, shall be below the specified value in Table 8.34BB, Table 8.34BC, Table 8.34BD and Table 8.34BE more than 90% of the time. BLER shall be as shown in Table 8.34BB, Table 8.34BC, Table 8.34BD and Table 8.34BE. Power control in downlink is ON during the test. Test requirements in Table 8.34BB, Table 8.34BC, Table 8.34BD and Table 8.34BE correspond to DL_DCH_FET_Config is set to 0 with UL in 20ms transmission mode, DL_DCH_FET_Config is set to 0 with UL in 10ms transmission mode, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and non-Null transmission in the UL, and, DL_DCH_FET_Config is set to 1 with UL in 10ms transmission mode and Null transmission in the UL respectively.

Table 8.34BA: Parameters for downlink power control in case of different transport formats

Parameter

Unit

Test 1

Stage 1

Stage 2

Time in each stage

s

Note 1

Note 1

dB

9

dBm/3.84 MHz

-60

Information Data Rate

kbps

12.2

0

DCCH Presence

No

Quality target on DTCH

BLER

0.01

Quality target on DCCH

BLER

1

Propagation condition

Case4

Maximum_DL_Power

dB

7

Minimum_DL_Power

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Note 1: The stage lasts until the DTCH quality has converged to the quality target

NOTE: Power is compared to P-CPICH as specified in [4].

Table 8.34BB: Requirements in downlink power control in case of different transport formats (DL_DCH_FET_Config is set to 0 with 20ms UL transmission mode)

Parameter

Unit

Test 1, stage 1

Test 1, stage 2

dB

-17.7

-19.8

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

Table 8.34BC: Requirements in downlink power control in case of different transport formats (DL_DCH_FET_Config is set to 0 with 10ms UL transmission mode)

Parameter

Unit

Test 1, stage 1

Test 1, stage 2

dB

-14.4

-16.6

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

Table 8.34BD: Requirements in downlink power control in case of different transport formats (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode)

Parameter

Unit

Test 1, stage 1

Test 1, stage 2

dB

-17.5

-19.8

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

Table 8.34BE: Requirements in downlink power control in case of different transport formats (DL_DCH_FET_Config is set to 1 with 10ms UL transmission mode and Null transmission in uplink)

Parameter

Unit

Test 1, stage 1

Test 1, stage 2

dB

-17.5

-19.8

Measured quality on DTCH

BLER

0.01±30%

0.01±30%

8.8.5 Power control in the downlink for F-DPCH

8.8.5.1 Minimum requirements

For the parameters specified in Table 8.34C the downlink power ratio measured values, which are averaged over TPC symbols of the F-DPCH frame, shall be below the specified value in Table 8.34D more than 90% of the time. TPC command error ratio shall be in the limits given by Table 8.34D. Power control in downlink is ON during the tests.

Table 8.34C: Test parameters for Fractional downlink power control

Parameter

Unit

Test 1

Test 2

dB

9

-1

dBm/3.84 MHz

-60

SF

256

Target quality value on F DPCH

%

0.01

0.05

Propagation condition

Case 4

Maximum_DL_Power *

dB

7

Minimum_DL_Power *

dB

-18

DL Power Control step size, TPC

dB

1

Limited Power Increase

"Not used"

Power-Control-Algorithm

Algorithm 1

Table 8.34D: Requirements in Fractional downlink power control

Parameter

Unit

Test 1

Test 2

dB

-15.9

-12.0

TPC command Error Ratio high

0.015

0.065

TPC command Error Ratio low

0.005

0.035