7.3 Reference sensitivity level

25.1013GPPRelease 17TSUser Equipment (UE) radio transmission and reception (FDD)

The reference sensitivity level <REFSENS> is the minimum mean power received at the UE antenna port at which the specified minimum requirement shall be met.

7.3.1 Minimum requirement

The BER shall not exceed 0.001 for the parameters specified in Table 7.2.

Table 7.2: Test parameters for reference sensitivity, minimum requirement.

Operating Band

Unit

DPCH_Ec <REFSENS>

<REFÎor>

I

dBm/3.84 MHz

-117

-106.7

II

dBm/3.84 MHz

-115

-104.7

III

dBm/3.84 MHz

-114

-103.7

IV

dBm/3.84 MHz

-117

-106.7

V

dBm/3.84 MHz

-115

-104.7

VI

dBm/3.84 MHz

-117

-106.7

VII

dBm/3.84 MHz

-115

-104.7

VIII

dBm/3.84 MHz

-114

-103.7

IX

dBm/3.84 MHz

-116

-105.7

X

dBm/3.84 MHz

-117

-106.7

XI

dBm/3.84 MHz

-117

-106.7

XII

dBm/3.84 MHz

-114

-103.7

XIII

dBm/3.84 MHz

-114

-103.7

XIV

dBm/3.84 MHz

-114

-103.7

XIX

dBm/3.84 MHz

-117

-106.7

XX

dBm/3.84 MHz

-114

-103.7

XXI

dBm/3.84 MHz

-117

-106.7

XXII

dBm/3.84 MHz

-114

-103.7

XXV

dBm/3.84 MHz

-113.5

-103.2

XXVI

dBm/3.84 MHz

-113.5

-103.2

NOTE 1 For Power class 3 and 3bis this shall be at the maximum output power

NOTE 2 For Power class 4 this shall be at the maximum output power

NOTE 3 For the UE which supports both Band III and Band IX operating frequencies, the reference sensitivity level of -114.5 dBm DPCH_Ec <REFSENS> shall apply for Band IX. The corresponding <REFÎor> is -104.2 dBm

NOTE 4 For the UE which supports both Band XI and Band XXI operating frequencies, the reference sensitivity level is FFS.

NOTE 5 For the UE which supports both Band V and Band XXVI operating frequencies, the reference sensitivity level of -115 dBm DPCH_Ec <REFSENS> shall apply for Band XXVI when the carrier frequency of the assigned UTRA channel is within 869-894 MHz. The corresponding <REFÎor> is -104.7 dBm.

For the UE which supports DB-DC-HSDPA configuration in Table 7.2aA, the reference sensitivity level DPCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2 are allowed to be increased by the amount given in Table 7.2aA for the applicable bands.

Table 7.2aA: Allowed de-sensitization relative to reference sensitivity for UE which supports DB-DC-HSDPA.

DB-DC-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

2

1

II, IV

4

1

I, XI

For the UE which supports dual band 4C-HSDPA configuration in Table 7.2aB, the reference sensitivity level DPCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2 are allowed to be increased by the amount given in Table 7.2aB for the applicable bands.

Table 7.2aB: Allowed de-sensitization relative to reference sensitivity for UE which supports dual band 4C-HSDPA.

Dual Band 4C-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

II-1-IV-2

II-2-IV-1

II-2-IV-2

1

II, IV

For the UE which supports E-UTRA inter-band carrier aggregation the reference sensitivity level DPCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2 are allowed to be increased by the amount given in Table 7.3.1-1A of TS 36.101[11] for those UTRA operating bands corresponding to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations. The tolerance in Table 7.3.1-1A of TS 36.101[11] does not apply to supported UTRA operating bands with frequency range below 1 GHz that correspond to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations when such bands are belonging only to band combination(s) where one band is <1GHz and another band is >1.7GHz and there is no harmonic relationship between the low band UL and high band DL.

In case the UE supports DB-DC-HSDPA or dual band 4C-HSDPA configurations and one or more of the E-UTRA inter-band carrier aggregation configurations listed in Table 7.3.1-1A of TS36.101[11] with a UTRA operating band that belongs to UTRA and E-UTRA carrier aggregation configurations, then

– When the UTRA operating band frequency range is ≤ 1GHz, the applicable additional tolerance shall be the average of the applicable tolerances, truncated to one decimal place for that operating band among the supported DB-DC-HSDPA, dual band 4C-HSDPA, and E-UTRA CA configurations, with the DB-DC-HSDPA, dual carrier 4C-HSDPA, and E-UTRA CA configurations counted separately. In case there is a harmonic relation between low band UL and high band DL, then the maximum tolerance among the different supported carrier aggregation configurations involving such band shall be applied

– When the UTRA operating band frequency range is >1GHz, the applicable additional tolerance shall be the maximum tolerance that applies for that operating band among the supported DB-DC-HSDPA, dual band HSDPA, and E-UTRA CA configurations.

7.3.2 Additional requirement for DC-HSDPA

The BLER measured on each individual cell shall not exceed 0.1 for the parameters specified in Table 7.2A.

Note: The reference sensitivity level <REFSENS> requirement for DC-HSDPA is not applicable for dual uplink operation. However, there might be a substantial Rx de-sensitization for the UE operating in bands which have less than 80 MHz Tx-Rx frequency separation, transmitting on more than one uplink frequency, at maximum power.

Table 7.2A: Test parameters for reference sensitivity, additional requirement for DC-HSDPA.

Operating Band

Unit

HS-PDSCH_Ec <REFSENS>

<REFÎor>

I

dBm/3.84 MHz

-113

-102.7

II

dBm/3.84 MHz

-111

-100.7

III

dBm/3.84 MHz

-110

-99.7

IV

dBm/3.84 MHz

-113

-102.7

V

dBm/3.84 MHz

-111

-100.7

VI

dBm/3.84 MHz

-113

-102.7

VII

dBm/3.84 MHz

-111

-100.7

VIII

dBm/3.84 MHz

-110

-99.7

IX

dBm/3.84 MHz

-112

-101.7

X

dBm/3.84 MHz

-113

-102.7

XI

dBm/3.84 MHz

-113

-102.7

XII

dBm/3.84 MHz

-110

-99.7

XIII

dBm/3.84 MHz

-110

-99.7

XIV

dBm/3.84 MHz

-110

-99.7

XIX

dBm/3.84 MHz

-113

-102.7

XX

dBm/3.84 MHz

-110

-99.7

XXI

dBm/3.84 MHz

-113

-102.7

XXII

dBm/3.84 MHz

-110

-99.7

XXV

dBm/3.84 MHz

-109.5

-99.2

XXVI

dBm/3.84 MHz

-109.5

-99.2

NOTE 1 For Power class 3 and 3bis this shall be at the maximum output power

NOTE 2 For Power class 4 this shall be at the maximum output power

NOTE 3 For the UE which supports both Band III and Band IX operating frequencies, the reference sensitivity level of -110.5 dBm HS-PDSCH_Ec <REFSENS> shall apply for Band IX. The corresponding <REFÎor> is -100.2 dBm

NOTE 4 For the UE which supports both Band XI and Band XXI operating frequencies, the reference sensitivity level is FFS.

NOTE 5 For the UE which supports both Band V and Band XXVI operating frequencies, the reference sensitivity level of -111 dBm HS-PDSCH_Ec <REFSENS> shall apply for Band XXVI when any of the carrier frequencies of the assigned UTRA channel is within 869-894 MHz. The corresponding <REFÎor> is -100.7 dBm.

For the UE which supports DB-DC-HSDPA configuration in Table 7.2AA, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2A are allowed to be increased by the amount given in Table 7.2AA for the applicable bands.

Table 7.2AA: Allowed de-sensitization relative to referenece sensitivity for UE which supports DB-DC-HSDPA.

DB-DC-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

2

1

II, IV

4

1

I, XI

For the UE which supports dual band 4C-HSDPA configuration in Table 7.2AB, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2A are allowed to be increased by the amount given in Table 7.2AB for the applicable bands.

Table 7.2AB: Allowed de-sensitization relative to reference sensitivity for UE which supports dual band 4C-HSDPA.

Dual Band 4C-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

II-1-IV-2

II-2-IV-1

II-2-IV-2

1

II, IV

For the UE which supports E-UTRA inter-band carrier aggregation the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2A are allowed to be increased by the amount given in Table 7.3.1-1A of TS 36.101[11] for those UTRA operating bands corresponding to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations. The tolerance in Table 7.3.1-1A of TS 36.101[11] does not apply to supported UTRA operating bands with frequency range below 1 GHz that correspond to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations when such bands are belonging only to band combination(s) where one band is <1GHz and another band is >1.7GHz and there is no harmonic relationship between the low band UL and high band DL.

In case the UE supports DB-DC-HSDPA or dual band 4C-HSDPA configurations and one or more of the E-UTRA inter-band carrier aggregation configurations listed in Table 7.3.1-1A of TS36.101[11] with a UTRA operating band that belongs to UTRA and E-UTRA carrier aggregation configurations, then

– When the UTRA operating band frequency range is ≤ 1GHz, the applicable additional tolerance shall be the average of the applicable tolerances, truncated to one decimal place for that operating band among the supported DB-DC-HSDPA, dual band 4C-HSDPA, and E-UTRA CA configurations, with the DB-DC-HSDPA, dual carrier 4C-HSDPA, and E-UTRA CA configurations counted separately. In case there is a harmonic relation between low band UL and high band DL, then the maximum tolerance among the different supported carrier aggregation configurations involving such band shall be applied

– When the UTRA operating band frequency range is >1GHz, the applicable additional tolerance shall be the maximum tolerance that applies for that operating band among the supported DB-DC-HSDPA, dual band 4C-HSDPA, and E-UTRA CA configurations.

7.3.3 Additional requirement for DB-DC-HSDPA

For all requirements listed in Table 7.2.B, corresponding to the specific DB-DC-HSDPA configuration(s) supported by the UE, (see Table 5.0aA), the BLER measured on each individual cell shall not exceed 0.1.

Table 7.2B: Test parameters for reference sensitivity, additional requirement for DB-DC-HSDPA.

DB-DC-HSDPA configuration

DL Band

UL Band

Unit

HS-PDSCH_Ec

<REFSENS>

<REFÎor>

1

I

I

dBm/3.84 MHz

-113

-102.7

VIII

dBm/3.84 MHz

-110

-99.7

I

VIII

dBm/3.84 MHz

-113

-102.7

VIII

dBm/3.84 MHz

-110

-99.7

2

II

II

dBm/3.84 MHz

-110

-99.7

IV

dBm/3.84 MHz

-112

-101.7

II

IV

dBm/3.84 MHz

-110

-99.7

IV

dBm/3.84 MHz

-112

-101.7

3

I

I

dBm/3.84 MHz

-113

-102.7

V

dBm/3.84 MHz

-111

-100.7

I

V

dBm/3.84 MHz

-113

-102.7

V

dBm/3.84 MHz

-111

-100.7

4

I

I

dBm/3.84 MHz

-112

-101.7

XI

dBm/3.84 MHz

-112

-101.7

I

XI

dBm/3.84 MHz

-112

-101.7

XI

dBm/3.84 MHz

-112

-101.7

5

II

II

dBm/3.84 MHz

-111

-100.7

V

dBm/3.84 MHz

-111

-100.7

II

V

dBm/3.84 MHz

-111

-100.7

V

dBm/3.84 MHz

-111

-100.7

6

I

I

dBm/3.84 MHz

-113

-102.7

XXXII

dBm/3.84 MHz

-113

-102.7

NOTE 1 For Power class 3 and 3bis this shall be at the maximum output power

NOTE 2 For Power class 4 this shall be at the maximum output power

7.3.4 Additional requirement for single band 4C-HSDPA

For all requirements listed in Table 7.2C, corresponding to the specific single band 4C-HSDPA configuration(s) supported by the UE, (see Table 5.0aB), the BLER measured on each individual cell shall not exceed 0.1.

Note: The reference sensitivity level <REFSENS> requirement for single band 4C-HSDPA is not applicable for dual uplink operation. However, there might be a substantial Rx de-sensitization for the UE operating in bands which have less than 80 MHz Tx-Rx frequency separation, transmitting on more than one uplink frequency, at maximum power.

Table 7.2C: Test parameters for reference sensitivity, additional requirement for single band 4C-HSDPA.

Single band 4C-HSDPA configuration

DL Band

Unit

HS-PDSCH_Ec <REFSENS>

<REFÎor>

UL-DL carrier separation

I-3

I

dBm/3.84 MHz

-113

-102.7

Minimum

II-3, II-4

II

dBm/3.84 MHz

-111

-100.7

Minimum

NOTE 1 For Power class 3, 3bis and 4, this shall be at the maximum output power

For the UE which supports DB-DC-HSDPA configuration in Table 7.2CA, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2C are allowed to be increased by the amount given in Table 7.2CA for the applicable bands.

Table 7.2CA: Allowed de-sensitization relative to reference sensitivity for UE which supports DB-DC-HSDPA.

DB-DC-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

2

1

II

4

1

I

For the UE which supports dual band 4C-HSDPA configuration in Table 7.2CB, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2C are allowed to be increased by the amount given in Table 7.2CB for the applicable bands.

Table 7.2CB: Allowed de-sensitization relative to reference sensitivity for UE which supports dual band 4C-HSDPA.

Dual Band 4C-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

II-1-IV-2

II-2-IV-1

II-2-IV-2

1

II

For the UE which supports E-UTRA inter-band carrier aggregation the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2C are allowed to be increased by the amount given in Table 7.3.1-1A of TS 36.101[11] for those UTRA operating bands corresponding to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations. The tolerance in Table 7.3.1-1A of TS 36.101[11] does not apply to supported UTRA operating bands with frequency range below 1 GHz that correspond to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations when such bands are belonging only to band combination(s) where one band is <1GHz and another band is >1.7GHz and there is no harmonic relationship between the low band UL and high band DL.

In case the UE supports DB-DC-HSDPA configurations and one or more of the E-UTRA inter-band carrier aggregation configurations listed in Table 7.3.1-1A of TS36.101[11] with a UTRA operating band that belongs to UTRA and E-UTRA carrier aggregation configurations, then

– When the UTRA operating band frequency range is ≤ 1GHz, the applicable additional tolerance shall be the average of the applicable tolerances, truncated to one decimal place for that operating band among the supported DB-DC-HSDPA and E-UTRA CA configurations, with the DB-DC-HSDPA and E-UTRA CA configurations counted separately. In case there is a harmonic relation between low band UL and high band DL, then the maximum tolerance among the different supported carrier aggregation configurations involving such band shall be applied

– When the UTRA operating band frequency range is >1GHz, the applicable additional tolerance shall be the maximum tolerance that applies for that operating band among the supported DB-DC-HSDPA and E-UTRA CA configurations.

7.3.5 Additional requirement for dual band 4C-HSDPA

For all requirements listed in Table 7.2D, corresponding to the specific dual band 4C-HSDPA configuration(s) supported by the UE, (see Table 5.0aC), the BLER measured on each individual cell shall not exceed 0.1.

Note: The reference sensitivity level <REFSENS> requirement for dual band 4C-HSDPA is not applicable for dual uplink operation. However, there might be a substantial Rx de-sensitization for the UE operating in bands which have less than 80 MHz Tx-Rx frequency separation, transmitting on more than one uplink frequency, at maximum power.

Table 7.2D: Test parameters for reference sensitivity, additional requirement for dual band 4C-HSDPA.

Dual band 4C-HSDPA configuration

DL Band

UL Band

Unit

HS-PDSCH_Ec <REFSENS>

<REFÎor>

UL-DL carrier separation

I-2-VIII-1

I-3-VIII-1

I-2-VIII-2

I-1-VIII-2

I

I

dBm/3.84 MHz

-113

-102.7

Minimum

VIII

dBm/3.84 MHz

-110

-99.7

Minimum

I

VIII

dBm/3.84 MHz

-113

-102.7

Minimum

VIII

dBm/3.84 MHz

-110

-99.7

Minimum

II-1-IV-2

II-2-IV-1

II-2-IV-2

II

II

dBm/3.84 MHz

-110

-99.7

Minimum

IV

dBm/3.84 MHz

-112

-101.7

Minimum

II

IV

dBm/3.84 MHz

-110

-99.7

Minimum

IV

dBm/3.84 MHz

-112

-101.7

Minimum

I-1-V-2

I-2-V-1

I-2-V-2

I

I

dBm/3.84 MHz

-113

-102.7

Minimum

V

dBm/3.84 MHz

-111

-100.7

Minimum

I

V

dBm/3.84 MHz

-113

-102.7

Minimum

V

dBm/3.84 MHz

-111

-100.7

Minimum

II-1-V-2

II

II

dBm/3.84 MHz

-111

-100.7

Minimum

V

dBm/3.84 MHz

-111

-100.7

Minimum

II

V

dBm/3.84 MHz

-111

-100.7

Minimum

V

dBm/3.84 MHz

-111

-100.7

Minimum

I-1-XXXII-2

I-2-XXXII-1

I

I

dBm/3.84 MHz

-113

-102.7

Minimum

XXXII

dBm/3.84 MHz

-113

-102.7

Minimum

NOTE 1 For Power class 3, 3bis and 4, this shall be at the maximum output power

7.3.6 Additional requirement for single band 8C-HSDPA

For all requirements listed in Table 7.2E, corresponding to the specific single band 8C-HSDPA configuration(s) supported by the UE, (see Table 5.0aD), the BLER measured on each individual cell shall not exceed 0.1.

Note: The reference sensitivity level <REFSENS> requirement for single band 8C-HSDPA is not applicable for dual uplink operation. However, there might be a substantial Rx de-sensitization for the UE operating in bands which have less than 80 MHz Tx-Rx frequency separation, transmitting on more than one uplink frequency, at maximum power.

Table 7.2E: Test parameters for reference sensitivity, additional requirement for single band 8C-HSDPA.

Single band 8C-HSDPA configuration

DL Band

Unit

HS-PDSCH_Ec <REFSENS>

<REFÎor>

UL-DL carrier separation

I-8

I

dBm/3.84 MHz

-113

-102.7

Minimum

NOTE 1 For Power class 3, 3bis and 4, this shall be at the maximum output power

7.3.7 Additional requirement for single band NC-4C-HSDPA

For all requirements listed in Table 7.2E, corresponding to the specific single band NC-4C-HSDPA configuration(s) supported by the UE, (see Table 5.0aE), the BLER measured on each individual cell shall not exceed 0.1.

Note: The reference sensitivity level <REFSENS> requirement for single band NC-4C-HSDPA is not applicable for dual uplink operation. However, there might be a substantial Rx de-sensitization for the UE operating in bands which have less than 80 MHz Tx-Rx frequency separation, transmitting on more than one uplink frequency, at maximum power.

Table 7.2E: Test parameters for reference sensitivity, additional requirement for single band NC-4C-HSDPA.

Single band NC-4C-HSDPA configuration

DL Band

Unit

HS-PDSCH_Ec <REFSENS>

<REFÎor>

UL-DL carrier separation

I-1-5-1, I-2-5-1, I-3-10-1

I

dBm/3.84 MHz

-113

-102.7

Minimum

IV-1-5-1, IV-2-10-1, IV-2-15-2, IV-2-20-1, IV-2-25-2

IV

dBm/3.84 MHz

-113

-102.7

Minimum

NOTE 1 For Power class 3, 3bis and 4, this shall be at the maximum output power

For the UE which supports DB-DC-HSDPA configuration in Table 7.2F, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2E are allowed to be increased by the amount given in Table 7.2F for the applicable bands.

Table 7.2F: Allowed de-sensitization relative to referenece sensitivity for UE which supports DB-DC-HSDPA.

DB-DC-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

2

1

IV

4

1

I

For the UE which supports dual band 4C-HSDPA configuration in Table 7.2G, the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2E are allowed to be increased by the amount given in Table 7.2G for the applicable bands.

Table 7.2G: Allowed de-sensitization relative to reference sensitivity for UE which supports dual band 4C-HSDPA.

Dual Band 4C-HSDPA Configuration

Allowed de-sensitization (dB)

Applicable bands

II-1-IV-2

II-2-IV-1

II-2-IV-2

1

IV

For the UE which supports E-UTRA inter-band carrier aggregation the reference sensitivity level HS-PDSCH_Ec <REFSENS> and corresponding <REFÎor> in Table 7.2E are allowed to be increased by the amount given in Table 7.3.1-1A of TS 36.101[11] for those UTRA operating bands corresponding to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations. The tolerance in Table 7.3.1-1A of TS 36.101[11] does not apply to supported UTRA operating bands with frequency range below 1 GHz that correspond to the E-UTRA operating bands that belong to the supported inter-band carrier aggregation configurations when such bands are belonging only to band combination(s) where one band is <1GHz and another band is >1.7GHz and there is no harmonic relationship between the low band UL and high band DL.

In case the UE supports DB-DC-HSDPA configurations and one or more of the E-UTRA inter-band carrier aggregation configurations listed in Table 7.3.1-1A of TS36.101[11] with a UTRA operating band that belongs to UTRA and E-UTRA carrier aggregation configurations, then

– When the UTRA operating band frequency range is ≤ 1GHz, the applicable additional tolerance shall be the average of the applicable tolerances, truncated to one decimal place for that operating band among the supported DB-DC-HSDPA and E-UTRA CA configurations, with the DB-DC-HSDPA and E-UTRA CA configurations counted separately. In case there is a harmonic relation between low band UL and high band DL, then the maximum tolerance among the different supported carrier aggregation configurations involving such band shall be applied

– When the UTRA operating band frequency range is >1GHz, the applicable additional tolerance shall be the maximum tolerance that applies for that operating band among the supported DB-DC-HSDPA and E-UTRA CA configurations.