7.3A.6 Reference sensitivity exceptions due to cross band isolation for CA

38.101-13GPPNRPart 1: Range 1 StandaloneRelease 17TSUser Equipment (UE) radio transmission and reception

Sensitivity degradation is allowed for a band if it is impacted by UL of another band part which belongs to NR band of the same NR CA configuration due to cross band isolation issues. The reference sensitivity degradation for the victim band due to cross band isolation is specified only for the specific uplink and downlink test points specified in Table 7.3A.6-1 for either PC3 and PC2 NR CA from a PC3 aggressor NR UL band, and for PC2 NR CA, in Table 7.3A.6-1afrom a PC2 aggressor NR UL band, and in Table 7.3A.6-1b from a PC1.5 aggressor NR single band uplink

In Tables 7.3A.6-1, 7.3A.6-1a and 7.3A.6-1b the following terminology is used to define the source of cross-band isolation interference:

  • “ACLR1” indicates that the first adjacent channel of the aggressor UL band falls into the Rx channel of victim band.
  • “ACLR2” indicates that the second adjacent channel of the aggressor UL band falls into the Rx channel of victim band.

“>ACLR2” indicates that neither the first, nor the second adjacent channel of the aggressor UL band falls into the Rx channel of victim band.

Table 7.3A.6-1: Reference sensitivity exceptions (MSD) and uplink/downlink configurations due to cross band isolation from a PC3 aggressor NR UL band for NR CA FR1

UL band

DL band

UL Fc

UL BW

SCS of UL band

UL RB Allocation

DL Fc

DL BW

MSD

Cross-band

Interference

source

(MHz)

(MHz)

(kHz)

LCRB

(MHz)

(MHz)

(dB)

n1

n3

1922.5

5

15

25 (RBstart=0)

1877.5

5

3

>ACLR2

n1

n3

1945

50

15

128 (RBstart=0)

1877.5

5

[19.7]

ACLR1

n1

n38

1955

50

15

128 (RBstart=142)

2572.5

5

2.9

>ACLR2

n1

n38

1955

50

15

128 (RBstart=142)

2590

40

2.9

>ACLR2

n1

n40

1977.5

5

15

25 (RBstart=0)

2302.5

5

6.6

>ACLR2

n1

n41

1955

50

15

128 (RBstart=142)

2501

10

6.1

>ACLR2

n1

n41

1970

20

15

100 (RBstart=6)

2546

100

0.7

>ACLR2

n3

n41

1765

40

15

50 (RBstart=166)

2501

10

0.7

>ACLR2

n3

n41

1765

40

15

50 (RBstart=166)

2546

100

0.7

>ACLR2

n3

n74

1712.5

5

15

25 (RBstart=0)

1515.5

5

2.6

>ACLR2

n5

n28

834

20

15

20 (RBstart=0)

800.5

5

[17.5]

ACLR2

n7

n3

2525

50

15

45 (RBstart=0)

1877.5

5

0.6

>ACLR2

n7

n40

2502.5

5

15

25 (RBstart=0)

2397.5

5

3.7

>ACLR2

n18

n285

822.5

15

15

25 (RBstart=0)

800.5

5

31.3

ACLR1

n34

n3

2012.5

5

15

25 (RBstart=0)

1877.5

5

3

>ACLR2

n38

n1

2580

20

15

100 (RBstart=0)

2167.5

5

1.9

>ACLR2

n38

n25

2585

30

15

160 (RBstart=0)

1992.5

5

0.6

>ACLR2

n38

n78

2610

20

15

100 (RBstart=0)

3305

10

8.3

>ACLR2

n40

n1

2302.5

10

30

24 (RBstart=0)

2167.5

5

8.3

>ACLR2

n40

n1

2340

80

30

216 (RBstart=0)

2167.5

5

[18.1]

ACLR2

n40

n7

2350

100

30

270 (RBstart=3)

2622.5

5

[21.9]

>ACLR2

n40

n7

2350

100

30

270 (RBstart=3)

2645

50

[13.5]

>ACLR2

n41

n1

2521

50

30

128 (RBstart=0)

2167.5

5

9.1

>ACLR2

n41

n3

2526

60

30

160 (RBstart=0)

1877.5

5

0.6

>ACLR2

n41

n25

2511

30

15

160 (RBstart=0)

1992.5

5

0.6

>ACLR2

n41

n48

2680

20

15

100 (RBstart=0)

3552.5

5

8.3

>ACLR2

n411

n66

2521

50

30

128 (RBstart=0)

2197.5

5

3.5

>ACLR2

n41

n70

2511

30

15

160 (RBstart=0)

2017.5

5

0.6

>ACLR2

n41

n77

2680

20

15

100 (RBstart=6)

3305

10

8.3

>ACLR2

n41

n78

2680

20

15

100 (RBstart=6)

3305

10

8.3

>ACLR2

n46

n48

5190

80

30

216 (RBstart=0)

3697.5

5

13.3

>ACLR2

n46

n48

5190

80

30

216 (RBstart=0)

3650

100

6.2

>ACLR2

n46

n78

5190

80

30

216 (RBstart=0)

3795

10

10.4

>ACLR2

n46

n78

5190

80

30

216 (RBstart=0)

3750

100

5.1

>ACLR2

n48

n411

3570

40

15

216 (RBstart=0)

2685

10

[4.5]

>ACLR2

n48

n411

3570

40

15

216 (RBstart=0)

2640

100

[4.5]

>ACLR2

n48

n46

3680

40

15

216 (RBstart=0)

5160

20

15.7

>ACLR2

n48

n96

3680

40

15

216 (RBstart=0)

5935

20

15.7

>ACLR2

n71

n29

688

20

15

20 (RBstart=86)

719.5

5

17.5

ACLR2

n77

n401

3350

100

30

270 (RBstart=0)

2397.5

10

4.5

>ACLR2

n77

n401

3350

100

30

270 (RBstart=0)

2350

100

4.5

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2685

10

4.5

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2640

100

4.5

>ACLR2

n78

n71

3350

100

30

270 (RBstart=0)

2687.5

5

4.5

>ACLR2

n78

n38

3350

100

30

270 (RBstart=0)

2617.5

5

3.3

>ACLR2

n78

n38

3350

100

30

270 (RBstart=0)

2600

40

3.3

>ACLR2

n78

n401

3350

100

30

270 (RBstart=0)

2397.5

5

4.5

>ACLR2

n78

n401

3350

100

30

270 (RBstart=0)

2350

100

4.5

>ACLR2

n78

n411

3350

100

30

270 (RBstart=0)

2685

10

4.5

>ACLR2

n78

n411

3350

100

30

270 (RBstart=0)

2640

100

4.5

>ACLR2

n78

n46

3750

100

30

270 (RBstart=3)

5160

20

13.5

>ACLR2

n783

n79

3750

100

30

270 (RBstart=3)

4420

40

2

>ACLR2

n783

n79

3750

100

30

270 (RBstart=3)

4450

100

2

>ACLR2

n79

n783

4450

100

30

270 (RBstart=0)

3795

10

2.6

>ACLR2

n79

n783

4450

100

30

270 (RBstart=0)

3750

100

2.6

>ACLR2

n96

n48

5965

80

30

216 (RBstart=0)

3697.5

5

13.3

>ACLR2

n96

n48

5965

80

30

216 (RBstart=0)

3650

100

6.2

>ACLR2

NOTE 1: Applicable only when harmonic mixing MSD for this combination is not applied.

NOTE 2: Void

NOTE 3: The requirements only apply for UEs supporting inter-band carrier aggregation with simultaneous Rx/Tx capability. Simultaneous Rx/Tx capability does not apply for UEs supporting band n78 with a n77 implementation.

NOTE 4: Void

NOTE 5: The MSD exceptions are applicable to the case that interference of UL band 3rd order IMD product falls into the affected DL channels.

Table 7.3A.6-1a: Reference sensitivity exceptions (MSD) and uplink/downlink configurations due to cross band isolation from a PC2 aggressor NR UL band for NR CA FR1

UL band

DL band

UL Fc

UL BW

SCS of UL band

UL RB Allocation

DL Fc

DL BW

MSD

Cross-band

Interference

source

(MHz)

(MHz)

(kHz)

LCRB

(MHz)

(MHz)

(dB)

n41

n3

2526

60

30

160 (RBstart=0)

1877.5

5

2.3

>ACLR2

n41

n25

2511

30

15

160 (RBstart=0)

1992.5

5

1.6

>ACLR2

n41

n66

2521

50

30

128 (RBstart=0)

2197.5

5

5.4

>ACLR2

n41

n77

2680

20

15

100 (RBstart=6)

3305

10

10.5

>ACLR2

n41

n79

2640

100

30

270 (RBstart=3)

4420

40

3.1

>ACLR2

n77

n2

3305

100

30

270 (RBstart=0)

1987.5

5

1.0

>ACLR2

n77

n25

3305

100

30

270 (RBstart=0)

1992.5

5

1.0

>ACLR2

n77

n30

3350

100

30

270 (RBstart=0)

2357.5

5

1.0

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2685

10

6.5

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2640

100

6.5

>ACLR2

n77

n66

3350

100

30

270 (RBstart=0)

2197.5

5

1.0

>ACLR2

n78

n7

3350

100

30

270 (RBstart=0)

2687.5

5

6.5

>ACLR2

n79

n41

4450

100

30

270 (RBstart=0)

2685

10

3.5

>ACLR2

NOTE 1: Applicable only when harmonic mixing MSD for this combination is not applied.

NOTE 2: Void.

Table 7.3A.6-1b: Reference sensitivity exceptions (MSD) and uplink/downlink configurations due to cross band isolation from a PC1.5 aggressor NR single UL band for DL NR CA FR1

UL band

DL band

UL Fc

UL BW

SCS of UL band

UL RB Allocation

DL Fc

DL BW

MSD

Cross-band

Interference

source

(MHz)

(MHz)

(kHz)

LCRB

(MHz)

(MHz)

(dB)

n41

n25

2511

30

15

160 (RBstart=0)

1992.5

5

2.8

>ACLR2

n41

n66

2521

50

30

128 (RBstart=0)

2197.5

5

7.7

>ACLR2

n41

n77

2680

20

15

100 (RBstart=6)

3305

10

13.3

>ACLR2

n77

n2

3305

100

30

270 (RBstart=0)

1987.5

5

1.8

>ACLR2

n77

n25

3305

100

30

270 (RBstart=0)

1992.5

5

1.8

>ACLR2

n77

n30

3350

100

30

270 (RBstart=0)

2357.5

5

1.8

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2685

10

9.0

>ACLR2

n77

n411

3350

100

30

270 (RBstart=0)

2640

100

9.0

>ACLR2

n77

n66

3350

100

30

270 (RBstart=0)

2197.5

5

1.8

>ACLR2

NOTE 1: Applicable only when harmonic mixing MSD for this combination is not applied.

NOTE 2: Void.

Table 7.3A.6.2: Void