7.3A.4 Reference sensitivity exceptions due to UL harmonic interference for CA
38.101-13GPPNRPart 1: Range 1 StandaloneRelease 17TSUser Equipment (UE) radio transmission and reception
Sensitivity degradation is allowed for different combinations of UL configurations and DL channel bandwidths if a band in frequency range 1 is impacted by UL harmonic interference from another band which belongs to NR band in frequency range 1 of the same downlink CA configuration. Reference sensitivity exceptions and uplink/downlink configurations due to UL harmonic from a PC3 aggressor NR UL band for either single band uplink or PC3 or PC2 CA are specified in Table 7.3A.4-1. For these exceptions, only the listed test points in Table 7.3A.4-1 are needed to be tested.
Table 7.3A.4-1: Reference sensitivity exceptions and uplink/downlink configurations due to UL harmonic from a PC3 aggressor NR UL band for NR DL CA FR1
UL band |
DL band |
UL BW |
SCS of UL band |
UL RB Allocation |
DL BW |
MSD |
UL/DL fc condition |
UL/DL harmonic order |
(MHz) |
(kHz) |
LCRB |
(MHz) |
(dB) |
||||
n1 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n1 |
n77 |
20 |
15 |
100 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n1 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n2 |
n48 |
5 |
15 |
25 (RBstart=0) |
5 |
27.1 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n48 |
10 |
15 |
50 (RBstart=0) |
1007 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n48 |
5 |
15 |
25 (RBstart=0) |
10 |
1.9 |
NOTE 6 |
UL2/DL1 near-miss |
n2 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n77 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n2 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n78 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n2 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n3 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n3 |
n77 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n3 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n3 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n3 |
n78 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n3 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n5 |
n778 |
5 |
15 |
16 (RBstart=0) |
10 |
10.5 |
NOTE 4 |
UL4/DL1 direct-hit |
n5 |
n778 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n5 |
n778 |
5 |
15 |
16 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n5 |
n778 |
5 |
15 |
25 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n5 |
n78 |
5 |
15 |
16 (RBstart=0) |
10 |
10.5 |
NOTE 4 |
UL4/DL1 direct-hit |
n5 |
n78 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n8 |
n313 |
N/A |
N/A |
N/A |
N/A |
N/A |
NOTE 2 |
UL2/DL1 direct-hit |
n8 |
n7 |
5 |
15 |
8 (RBstart=0) |
5 |
10 |
NOTE 3 |
UL3/DL1 direct-hit |
n8 |
n7 |
5 |
15 |
25 (RBstart=0) |
50 |
1.1 |
NOTE 3 |
UL3/DL1 direct-hit |
n8 |
n41 |
5 |
15 |
16 (RBstart=0) |
10 |
13 |
NOTE 3 |
UL3/DL1 direct-hit |
n8 |
n41 |
5 |
15 |
25 (RBstart=0) |
100 |
3.5 |
NOTE 3 |
UL3/DL1 direct-hit |
n8 |
n77 |
5 |
15 |
16 (RBstart=0) |
10 |
10.8 |
NOTE 4 |
UL4/DL1 direct-hit |
n8 |
n77 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n8 |
n78 |
5 |
15 |
16 (RBstart=0) |
10 |
10.8 |
NOTE 4 |
UL4/DL1 direct-hit |
n8 |
n78 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n8 |
n79 |
5 |
15 |
16 (RBstart=0) |
10 |
12.0 |
NOTE 5 |
UL5/DL1 direct-hit |
n8 |
n79 |
5 |
15 |
25 (RBstart=0) |
100 |
4.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n12 |
n48 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n12 |
n48 |
5 |
15 |
25 (RBstart=0) |
40 |
4.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n12 |
n66 |
5 |
15 |
8 (RBstart=0) |
10 |
10 |
NOTE 3 |
UL3/DL1 direct-hit |
n12 |
n66 |
5 |
15 |
20 (RBstart=0) |
40 |
2.4 |
NOTE 3 |
UL3/DL1 direct-hit |
n12 |
n77 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n12 |
n77 |
5 |
15 |
20 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n13 |
n77 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n13 |
n77 |
5 |
15 |
20 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n14 |
n77 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n14 |
n77 |
5 |
15 |
20 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n18 |
n77 |
5 |
15 |
16 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n18 |
n77 |
5 |
15 |
25 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n20 |
n78 |
5 |
15 |
16 (RBstart=0) |
10 |
10.8 |
NOTE 4 |
UL4/DL1 direct-hit |
n20 |
n78 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n24 |
n7712 |
N/A |
N/A |
N/A |
N/A |
N/A |
NOTE 2 |
UL2/DL1 direct-hit |
n24 |
n7712 |
N/A |
N/A |
N/A |
N/A |
N/A |
NOTE 2 |
UL2/DL1 direct-hit |
n25 |
n48 |
5 |
15 |
25 (RBstart=0) |
10 |
1.9 |
NOTE 6 |
UL2/DL1 near-miss |
n25 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n25 |
n77 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n25 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n25 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n25 |
n78 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n25 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n28 |
n1 |
5 |
15 |
8 (RBstart=0) |
5 |
10.2 |
NOTE 3 |
UL3/DL1 direct-hit |
n28 |
n1 |
5 |
15 |
25 (RBstart=0) |
50 |
1.1 |
NOTE 3 |
UL3/DL1 direct-hit |
n28 |
n50 |
5 |
15 |
12 (RBstart=0) |
5 |
23.0 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n50 |
5 |
15 |
25 (RBstart=0) |
80 |
10.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n74 |
5 |
15 |
12 (RBstart=0) |
5 |
23.1 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n74 |
5 |
15 |
25 (RBstart=0) |
20 |
16.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n75 |
5 |
15 |
12 (RBstart=0) |
5 |
28.1 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n75 |
10 |
15 |
50 (RBstart=0) |
50 |
18.7 |
NOTE 2 |
UL2/DL1 direct-hit |
n28 |
n77 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n28 |
n77 |
5 |
15 |
25 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n28 |
n78 |
5 |
15 |
10 (RBstart=0) |
10 |
10.4 |
NOTE 5 |
UL5/DL1 direct-hit |
n28 |
n78 |
5 |
15 |
25 (RBstart=0) |
100 |
0.7 |
NOTE 5 |
UL5/DL1 direct-hit |
n66 |
n48 |
5 |
15 |
12 (RBstart=0) |
5 |
27.1 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n48 |
40 |
15 |
200 (RBstart=0) |
1007 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n48 |
5 |
15 |
12 (RBstart=0) |
10 |
1.9 |
NOTE 6 |
UL2/DL1 near-miss |
n66 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n77 |
20 |
15 |
100 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n77 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n66 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n78 |
20 |
15 |
100 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n66 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n70 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
23.9 |
NOTE 2 |
UL2/DL1 direct-hit |
n70 |
n78 |
10 |
15 |
50 (RBstart=0) |
100 |
13.8 |
NOTE 2 |
UL2/DL1 direct-hit |
n70 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
1.1 |
NOTE 6 |
UL2/DL1 near-miss |
n71 |
n2510,11 |
5 |
15 |
8 (RBstart=0) |
10 |
10 |
NOTE 3 |
UL3/DL1 direct-hit |
n71 |
n2510,11 |
5 |
15 |
8 (RBstart=0) |
40 |
2.1 |
NOTE 3 |
UL3/DL1 direct-hit |
n71 |
n41 |
5 |
15 |
16 (RBstart=0) |
10 |
10.8 |
NOTE 4 |
UL4/DL1 direct-hit |
n71 |
n41 |
5 |
15 |
25 (RBstart=0) |
100 |
1.4 |
NOTE 4 |
UL4/DL1 direct-hit |
n71 |
n70 |
5 |
15 |
8 (RBstart=0) |
5 |
9.9 |
NOTE 3 |
UL3/DL1 direct-hit |
n71 |
n70 |
5 |
15 |
20 (RBstart=0) |
25 |
4.1 |
NOTE 3 |
UL3/DL1 direct-hit |
n92 |
n78 |
5 |
15 |
16 (RBstart=0) |
10 |
10.8 |
NOTE 4 |
UL4/DL1 direct-hit |
n92 |
n78 |
5 |
15 |
25 (RBstart=0) |
100 |
1.0 |
NOTE 4 |
UL4/DL1 direct-hit |
NOTE 1: These requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the aggressor (lower) band for which the 2nd / 3rd / 4th / 5th transmitter harmonic is within the downlink transmission bandwidth of a victim (higher) band. NOTE 2: The requirements should be verified for UL NR ARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band. NOTE 3: The requirements should be verified for UL NR ARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with the carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the low band. NOTE 4: The requirements should be verified for UL EARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band. NOTE 5: The requirements should be verified for UL NR-ARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band. NOTE 6: The requirements are only applicable to channel bandwidths no larger than 20 MHz and with a carrier frequency at MHz offset from in the victim (higher band) with , whereandare the channel bandwidths configured in the aggressor (lower) and victim (higher) bands in MHz, respectively. NOTE 7: For these bandwidths, the minimum requirements are restricted to operation when carrier is configured as a downlink carrier part of CA configuration. NOTE 8: For a UE which supports this band combination only when the Band n77 frequency range restriction defined in NOTE 12 of Table 5.2-1 applies, the MSD test point(s) cannot be verified for the band combination and the test point(s) can be skipped. NOTE 9: Void. NOTE 10: These requirements apply when the lower edge frequency of the 10 MHz, 15 MHz, or 20 MHz uplink channel in Band 71 is located at or below 668 MHz and the downlink channel in Band n25 is located with its upper edge at 1995 MHz. NOTE 11: These requirements apply when the lower edge frequency of the uplink channel in Band n71 is located at or below 668 MHz and the downlink channel in Band n25 is located with its upper edge at 1990 MHz. NOTE 12: In the USA, n77 band is restricted to 3450 – 3550 MHz and 3700 – 3980 MHz. There is no UL harmonic due to n24 UL in downlink for n77 operating in 3450 – 3550 MHz and 3700 – 3980 MHz. NOTE 13: No requirements apply when there is at least one individual RE within the uplink transmission bandwidth of the low band for which the 2nd transmitter harmonic is within the downlink transmission bandwidth of the high band. The reference sensitivity for all active downlink component carriers is only verified when this is not the case (the requirements specified in clause 7.3.2 apply unless otherwise specified). |
Table 7.3A.4-1a: NR-U reference sensitivity measurement exclusion region in MHz.
NR Band / Harmonic order / Channel BW in UL |
|||||||||
Band |
Harmonic order |
5MHz |
10MHz |
15MHz |
20 MHz |
25 MHz |
30 MHz |
40MHz |
50 MHz |
n7 |
2 |
+/- 10 |
+/- 20 |
+/- 30 |
+/- 40 |
+/- 50 |
+/- 60 |
+/- 80 |
+/- 100 |
n25 |
3 |
+/- 15 |
+/- 23 |
+/- 35 |
+/- 45 |
+/- 90 |
|||
n66 |
3 |
+/- 15 |
+/- 23 |
+/- 35 |
+/- 45 |
+/- 90 |
|||
n48 |
2 |
+/- 10 |
+/- 20 |
+/- 30 |
+/- 40 |
+/- 80 |
|||
NOTE 1: Even though UL harmonic does not fall directly into NR-U band the exclusion region still applies. NOTE 2: The center of the exclusion region is obtained by multiplying the UL channel center frequency by the harmonic order. |
Table 7.3A.4-2: VoidTable 7.3A.4-3: Void
Table 7.3A.4-3a: Void
Sensitivity degradation is allowed for different combinations of UL configurations and DL channel bandwidths if a band is impacted by receiver harmonic mixing due to another band part which belongs to PC3 NR band or PC2 NR band of the same CA configuration. Reference sensitivity exceptions and uplink/downlink configurations due to harmonic mixing from a PC3 aggressor NR UL band for either PC3 or PC2 CA are specified in Table 7.3A.4-4 and from a PC2 aggressor NR UL band for PC2 CA are specified in Table 7.3A.4-4a.For these exceptions, only the listed test points in Table 7.3A.4-4, Table 7.3A.4-4a and Table 7.3A.4-4b are needed to be tested.
Table 7.3A.4-4: Reference sensitivity exceptions and uplink/downlink configurations due to harmonic mixing from a PC3 aggressor NR UL band for DL NR CA FR1
UL band |
DL band |
UL BW |
SCS of UL band |
UL RB Allocation |
DL BW |
MSD |
UL/DL fc condition |
UL/DL harmonic order |
(MHz) |
(kHz) |
LCRB |
(MHz) |
(dB) |
||||
n25 |
n713 |
5 |
15 |
25 (RBstart=0) |
5 |
26.5 |
NOTE 4 |
UL1/DL3 |
n25 |
n713 |
20 |
15 |
100 (RBstart=0) |
20 |
13.5 |
NOTE 4 |
UL1/DL3 |
n40 |
n20 |
5 |
15 |
25 (RBstart=0) |
5 |
27.8 |
NOTE 4 |
UL1/DL3 |
n40 |
n20 |
20 |
15 |
100 (RBstart=0) |
20 |
20.3 |
NOTE 4 |
UL1/DL3 |
n40 |
n28 |
5 |
15 |
25 (RBstart=0) |
5 |
37.8 |
NOTE 4 |
UL1/DL3 |
n40 |
n28 |
20 |
15 |
100 (RBstart=0) |
20 |
30.3 |
NOTE 4 |
UL1/DL3 |
n40 |
n77 |
10 |
30 |
24 (RBstart=0) |
10 |
8.3 |
NOTE 1 |
UL3/DL2 |
n40 |
n77 |
10 |
30 |
24 (RBstart=0) |
100 |
0.4 |
NOTE 1 |
UL3/DL2 |
n40 |
n78 |
10 |
30 |
24 (RBstart=0) |
10 |
8.3 |
NOTE 1 |
UL3/DL2 |
n40 |
n78 |
10 |
30 |
24 (RBstart=0) |
100 |
0.4 |
NOTE 1 |
UL3/DL2 |
n41 |
n183 |
5 |
15 |
25 (RBstart=0) |
5 |
24.3 |
NOTE 4 |
UL1/DL3 |
n41 |
n183 |
15 |
15 |
75 (RBstart=0) |
15 |
22.5 |
NOTE 4 |
UL1/DL3 |
n41 |
n48 |
10 |
30 |
24 (RBstart=0) |
10 |
8.3 |
NOTE 1 |
UL3/DL2 |
n41 |
n48 |
10 |
30 |
24 (RBstart=0) |
100 |
0.4 |
NOTE 1 |
UL3/DL2 |
n41 |
n78 |
10 |
30 |
24 (RBstart=0) |
10 |
8.3 |
NOTE 1 |
UL3/DL2 |
n41 |
n78 |
10 |
30 |
24 (RBstart=0) |
100 |
0.4 |
NOTE 1 |
UL3/DL2 |
n46 |
n7 |
5 |
15 |
12 (RBstart=0) |
5 |
8.3 |
NOTE 1 |
UL3/DL2 |
n46 |
n7 |
5 |
15 |
24 (RBstart=0) |
50 |
0.6 |
NOTE 1 |
UL3/DL2 |
n46 |
n48 |
5 |
15 |
12 (RBstart=0) |
5 |
22.6 |
NOTE 1 |
UL3/DL2 |
n46 |
n48 |
20 |
15 |
100 (RBstart=0) |
100 |
12 |
NOTE 1 |
UL3/DL2 |
n46 |
n78 |
5 |
15 |
25 (RBstart=0) |
10 |
19.5 |
NOTE 1 |
UL3/DL2 |
n46 |
n78 |
20 |
15 |
100 (RBstart=0) |
100 |
12 |
NOTE 1 |
UL3/DL2 |
n77 |
n2 |
10 |
15 |
25 (RBstart=0) |
5 |
6.7 |
NOTE 7 |
UL1/DL2 |
n77 |
n2 |
20 |
15 |
100 (RBstart=0) |
20 |
3,7 |
NOTE 7 |
UL1/DL2 |
n77 |
n5 |
5 |
15 |
25 (RBstart=0) |
5 |
5.7 |
NOTE 8 |
UL1/DL4 |
n77 |
n5 |
20 |
15 |
100 (RBstart=0) |
20 |
2.7 |
NOTE 8 |
UL1/DL4 |
n77 |
n12 |
10 |
15 |
25 (RBstart=0) |
5 |
31 |
NOTE 5 |
UL1/DL5 |
n77 |
n12 |
15 |
15 |
75 (RBstart=0) |
15 |
26.2 |
NOTE 5 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
25 (RBstart=0) |
5 |
31 |
NOTE 5 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
50 (RBstart=0) |
10 |
28 |
NOTE 5 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
25 (RBstart=0) |
5 |
31 |
NOTE 5 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
50 (RBstart=0) |
10 |
28 |
NOTE 5 |
UL1/DL5 |
n77 |
n25 |
10 |
15 |
25 (RBstart=0) |
5 |
6.7 |
NOTE 7 |
UL1/DL2 |
n77 |
n25 |
20 |
15 |
100 (RBstart=0) |
40 |
1.1 |
NOTE 7 |
UL1/DL2 |
n776 |
n29 |
10 |
15 |
25 (RBstart=0) |
5 |
31 |
NOTE 5 |
UL1/DL5 |
n776 |
n29 |
10 |
15 |
50 (RBstart=0) |
10 |
28 |
NOTE 5 |
UL1/DL5 |
n77 |
n30 |
10 |
15 |
12 (RBstart=0) |
5 |
10.4 |
NOTE 2 |
UL2/DL3 |
n77 |
n30 |
10 |
15 |
24 (RBstart=0) |
10 |
8.0 |
NOTE 2 |
UL2/DL3 |
n77 |
n40 |
20 |
30 |
50 (RBstart=0) |
10 |
10.4 |
NOTE 2 |
UL2/DL3 |
n77 |
n40 |
20 |
30 |
50 (RBstart=0) |
100 |
0.9 |
NOTE 2 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
10 |
10.4 |
NOTE 2 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
100 |
6.3 |
NOTE 2 |
UL2/DL3 |
n78 |
n40 |
20 |
30 |
50 (RBstart=0) |
5 |
10.4 |
NOTE 2 |
UL2/DL3 |
n78 |
n40 |
20 |
30 |
50 (RBstart=0) |
80 |
4.5 |
NOTE 2 |
UL2/DL3 |
n78 |
n41 |
20 |
30 |
50 (RBstart=0) |
10 |
10.4 |
NOTE 2 |
UL2/DL3 |
n78 |
n41 |
20 |
30 |
50 (RBstart=0) |
100 |
6.3 |
NOTE 2 |
UL2/DL3 |
n96 |
n48 |
5 |
15 |
25 (RBstart=0) |
5 |
5.8 |
NOTE 2 |
UL2/DL3 |
n96 |
n48 |
20 |
15 |
100 (RBstart=0) |
100 |
0.5 |
NOTE 2 |
UL2/DL3 |
NOTE 1: The requirements should be verified for UL NR-ARFCN of the aggressor (lower) band (superscript LB) such that in MHz and with carrier frequency in the victim (higher) band in MHz and the channel bandwidth configured in the lower band. NOTE 2: The requirements should be verified for UL NR-ARFCN of the aggressor (high) band (superscript HB) such that in MHz and with carrier frequency in the victim (lower) band in MHz and the channel bandwidth configured in the higher band. NOTE 3: These requirements apply when there is at least one individual RE within the downlink transmission bandwidth of the victim (lower) band for which the 3rd harmonic is within the uplink transmission bandwidth or the uplink adjacent channel’s transmission bandwidth of an aggressor (higher) band. NOTE 4: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. NOTE 5: The requirements should be verified for DL EARFCN of the victim (lower) band (superscript LB) such that with the DL carrier frequency in the lower band and the UL carrier frequency in the higher band, both in MHz. NOTE 6: For a UE which supports this band combination only when the Band n77 frequency range restriction defined in NOTE 12 of Table 5.2-1 applies, the MSD test point(s) cannot be verified for the band combination and the test point(s) can be skipped. NOTE 7: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. NOTE 8: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. |
Table 7.3A.4-4a: Reference sensitivity exceptions and uplink/downlink configurations due to harmonic mixing from a PC2 aggressor NR UL band for NR DL CA FR1
UL band |
DL band |
UL BW |
SCS of UL band |
UL RB Allocation |
DL BW |
MSD |
UL/DL fc condition |
UL/DL harmonic order |
(MHz) |
(kHz) |
LCRB |
(MHz) |
(dB) |
||||
n77 |
n2 |
10 |
15 |
25 (RBstart=0) |
5 |
9.1 |
NOTE 4 |
UL1/DL2 |
n77 |
n2 |
20 |
15 |
100 (RBstart=0) |
20 |
6.7 |
NOTE 4 |
UL1/DL2 |
n77 |
n5 |
10 |
15 |
25 (RBstart=0) |
5 |
8.1 |
NOTE 5 |
UL1/DL4 |
n77 |
n5 |
20 |
15 |
20 (RBstart=0) |
20 |
4.3 |
NOTE 5 |
UL1/DL4 |
n77 |
n12 |
10 |
15 |
25 (RBstart=0) |
5 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n12 |
15 |
15 |
75 (RBstart=0) |
15 |
29.2 |
NOTE 1 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
25 (RBstart=0) |
5 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
50 (RBstart=0) |
10 |
31 |
NOTE 1 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
25 (RBstart=0) |
5 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
50 (RBstart=0) |
10 |
31 |
NOTE 1 |
UL1/DL5 |
n77 |
n25 |
10 |
15 |
25 (RBstart=0) |
5 |
9.2 |
NOTE 4 |
UL1/DL2 |
n77 |
n25 |
20 |
15 |
100 (RBstart=0) |
40 |
2.0 |
NOTE 4 |
UL1/DL2 |
n772 |
n29 |
10 |
15 |
25 (RBstart=0) |
5 |
34 |
NOTE 1 |
UL1/DL5 |
n772 |
n29 |
10 |
15 |
50 (RBstart=0) |
10 |
31 |
NOTE 1 |
UL1/DL5 |
n77 |
n30 |
10 |
15 |
12 (RBstart=0) |
5 |
13.2 |
NOTE 3 |
UL2/DL3 |
n77 |
n30 |
10 |
15 |
25 (RBstart=0) |
10 |
10.6 |
NOTE 3 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
10 |
13.2 |
NOTE 3 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
100 |
8.8 |
NOTE 3 |
UL2/DL3 |
n78 |
n3 |
5 |
15 |
25 (RBstart=0) |
5 |
8.1 |
NOTE 4 |
UL1/DL2 |
n78 |
n3 |
40 |
15 |
216 (RBstart=0) |
40 |
1 |
NOTE 4 |
UL1/DL2 |
n78 |
n28 |
5 |
15 |
25 (RBstart=0) |
5 |
31 |
NOTE 1 |
UL1/DL5 |
n78 |
n28 |
30 |
15 |
160 (RBstart=0) |
30 |
11.7 |
NOTE 1 |
UL1/DL5 |
NOTE 1: The requirements should be verified for DL EARFCN of the victim (lower) band (superscript LB) such that with the DL carrier frequency in the lower band and the UL carrier frequency in the higher band, both in MHz. NOTE 2: For a UE which supports this band combination only when the Band n77 frequency range restriction defined in NOTE 12 of Table 5.2-1 from TS 38.101-1 applies, the MSD test point(s) cannot be verified for the band combination and the test point(s) can be skipped. NOTE 3: The requirements should be verified for UL NR-ARFCN of the aggressor (high) band (superscript HB) such that in MHz and with carrier frequency in the victim (lower) band in MHz and the channel bandwidth configured in the higher band. NOTE 4: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. NOTE 5: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. |
Table 7.3A.4-4b: Reference sensitivity exceptions and uplink/downlink configurations due to harmonic mixing from a PC1.5 NR UL band for NR DL CA FR1
UL band |
DL band |
UL BW |
SCS of UL band |
UL RB Allocation |
DL BW |
MSD |
UL/DL fc condition |
UL/DL harmonic order |
(MHz) |
(kHz) |
LCRB |
(MHz) |
(dB) |
||||
n77 |
n2 |
10 |
15 |
25 (RBstart=0) |
5 |
11.8 |
NOTE 4 |
UL1/DL2 |
n77 |
n2 |
20 |
15 |
100 (RBstart=0) |
20 |
9.2 |
NOTE 4 |
UL1/DL2 |
n77 |
n5 |
10 |
15 |
25 (RBstart=0) |
5 |
10.7 |
NOTE 5 |
UL1/DL4 |
n77 |
n5 |
20 |
15 |
20 (RBstart=0) |
20 |
6.4 |
NOTE 5 |
UL1/DL4 |
n77 |
n12 |
10 |
15 |
25 (RBstart=0) |
5 |
37 |
NOTE 1 |
UL1/DL5 |
n77 |
n12 |
15 |
15 |
75 (RBstart=0) |
15 |
32.2 |
NOTE 1 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
25 (RBstart=0) |
5 |
37 |
NOTE 1 |
UL1/DL5 |
n77 |
n13 |
10 |
15 |
50 (RBstart=0) |
10 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
25 (RBstart=0) |
5 |
37 |
NOTE 1 |
UL1/DL5 |
n77 |
n14 |
10 |
15 |
50 (RBstart=0) |
10 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n25 |
10 |
15 |
25 (RBstart=0) |
5 |
11.9 |
NOTE 4 |
UL1/DL2 |
n77 |
n25 |
20 |
15 |
100 (RBstart=0) |
40 |
3.3 |
NOTE 4 |
UL1/DL2 |
n77 |
n29 |
10 |
15 |
25 (RBstart=0) |
5 |
37 |
NOTE 1 |
UL1/DL5 |
n77 |
n29 |
10 |
15 |
50 (RBstart=0) |
10 |
34 |
NOTE 1 |
UL1/DL5 |
n77 |
n30 |
10 |
15 |
12 (RBstart=0) |
5 |
16.1 |
NOTE 3 |
UL2/DL3 |
n77 |
n30 |
10 |
15 |
25 (RBstart=0) |
10 |
13.5 |
NOTE 3 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
10 |
16.1 |
NOTE 3 |
UL2/DL3 |
n77 |
n41 |
20 |
30 |
50 (RBstart=0) |
100 |
11.5 |
NOTE 3 |
UL2/DL3 |
NOTE 1: The requirements should be verified for DL EARFCN of the victim (lower) band (superscript LB) such that with the DL carrier frequency in the lower band and the UL carrier frequency in the higher band, both in MHz. NOTE 2: For a UE which supports this band combination only when the Band n77 frequency range restriction defined in NOTE 12 of Table 5.2-1 from TS 38.101-1 applies, the MSD test point(s) cannot be verified for the band combination and the test point(s) can be skipped. NOTE 3: The requirements should be verified for UL NR-ARFCN of the aggressor (high) band (superscript HB) such that in MHz and with carrier frequency in the victim (lower) band in MHz and the channel bandwidth configured in the higher band. NOTE 4: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. NOTE 5: The requirements should be verified for UL NR-ARFCN of the aggressor (higher) band (superscript HB) such that in MHz and with the carrier frequency in the victim (lower) band and the channel bandwidth configured in the higher band. |
Table 7.3A.4-5: Void