8.1.3 NB-IoT Reference test conditions

36.5083GPPCommon test environments for User Equipment (UE) conformance testingEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Release 17TS

This clause contains the reference test conditions, which apply to all NB-IoT test cases unless otherwise specified.

8.1.3.1 NB-IoT Test frequencies

NB-IoT is designed to operate in the E-UTRA operating bands 1, 2, 3, 4, 5, 7, 8, 11, 12, 13, 14, 17, 18, 19, 20, 21, 25, 26, 28, 31, 41, 42, 43, 65, 66, 70, 71, 72, 73, 74, 85, 87, 88 and 103 which are defined in Table 5.5-1 in [21]. NB-IoT system operates in HD-FDD and TDD duplex mode or in TDD mode.

The test frequencies are based on the E-UTRA frequency bands defined in the core specifications.

The raster spacing is 100 kHz.

E-UTRA/FDD is designed to operate in paired bands of 3GPP TS 36.101 [27]. The reference test frequencies for the RF and Signalling test environment for each of the operating bands are defined in sub clause 8.1.3.1.1 and 8.1.3.1.2.

E-UTRA/TDD is designed to operate in unpaired bands of 3GPP TS 36.101 [27]. The reference test frequencies for the RF and Signalling test environment for each of the operating bands are defined in sub clause 8.1.3.1.2.

USA & Canada emission requirements for specific operating bands are indicated by network signaling value NS_04 on indicated bands in clause 8.1.3.1.1. The normative reference for this requirement is TS 36.101 [27] clause 5.5F.

8.1.3.1.1 NB-IoT FDD Mode Test frequencies

8.1.3.1.1.1 NB-IoT FDD reference test frequencies for operating band 1

Table 8.1.3.1.1.1-1: NB-IoT standalone Test frequencies for operating band 1

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

18001

0

1920.1

1

-0.5

2110.1

Mid Range

18300

0

1950.0

300

-0.5

2140.0

High Range

18599

0

1979.9

599

-0.5

2169.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.1-2: NB-IoT in-band Test frequencies for operating band 1

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

18007

0

1920.7000

7

-2

2110.6925

Low Range2

18060

-2

1925.9900

60

-1

2115.9975

Low Range3

18069

-2

1926.8900

69

-1

2116.8975

Mid Range1

18291

0

1949.1000

291

-2

2139.0925

Mid Range2

18310

-2

1950.9900

310

-1

2140.9975

Mid Range3

18319

-2

1951.8900

319

-1

2141.8975

High Range1

18593

0

1979.3000

593

1

2169.3075

High Range2

18560

-2

1975.9900

560

-1

2165.9975

High Range3

18569

-2

1976.8900

569

-1

2166.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.1-3: NB-IoT guard-band Test frequencies for operating band 1

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

18001

0

1920.1000

1

1

2110.1075

Mid Range

5

18276

0

1947.6000

276

1

2137.6075

10

18346

0

1954.6000

346

1

2144.6075

High Range

Any

18599

0

1979.9000

599

-2

2169.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.2 NB-IoT FDD reference test frequencies for operating band 2

Table 8.1.3.1.1.2-1: NB-IoT standalone Test frequencies for operating band 2

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

18601

0

1850.1

601

-0.5

1930.1

Mid Range

18900

0

1880.0

900

-0.5

1960.0

High Range

19199

0

1909.9

1199

-0.5

1989.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.2-1a: NB-IoT standalone Test frequencies for operating band 2 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

18602

0

1850.2

602

-0.5

1930.2

Mid Range

18900

0

1880.0

900

-0.5

1960.0

High Range

19198

0

1909.8

1198

-0.5

1989.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.2-2: NB-IoT in-band Test frequencies for operating band 2

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

18606

0

1850.6000

606

-2

1930.5925

Low Range2

18660

-2

1855.9900

660

-1

1935.9975

Low Range3

18669

-2

1856.8900

669

-1

1936.8975

Mid Range1

18891

0

1879.1000

891

-2

1959.0925

Mid Range2

18910

-2

1880.9900

910

-1

1960.9975

Mid Range3

18919

-2

1881.8900

919

-1

1961.8975

High Range1

19194

0

1909.4000

1194

1

1989.4075

High Range2

19160

-2

1905.9900

1160

-1

1985.9975

High Range3

19169

-2

1906.8900

1169

-1

1986.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.2-2a: NB-IoT in-band Test frequencies for operating band 2 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

18606

0

1850.6000

606

-2

1930.5925

Low Range2

18660

-2

1855.9900

660

-1

1935.9975

Low Range3

18669

-2

1856.8900

669

-1

1936.8975

Mid Range1

18891

0

1879.1000

891

-2

1959.0925

Mid Range2

18910

-2

1880.9900

910

-1

1960.9975

Mid Range3

18919

-2

1881.8900

919

-1

1961.8975

High Range1

19194

0

1909.4000

1194

1

1989.4075

High Range2

19160

-2

1905.9900

1160

-1

1985.9975

High Range3

19169

-2

1906.8900

1169

-1

1986.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.2-3: NB-IoT guard-band Test frequencies for operating band 2

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

18601

0

1850.1000

601

1

1930.1075

Mid Range

5

18876

0

1877.6000

876

1

1957.6075

10

18946

0

1884.6000

946

1

1964.6075

High Range

Any

19199

0

1909.9000

1199

-2

1989.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.2-3a: NB-IoT guard-band Test frequencies for operating band 2 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

18602

0

1850.2000

602

1

1930.2075

Mid Range

5

18876

0

1877.6000

876

1

1957.6075

10

18946

0

1884.6000

946

1

1964.6075

High Range

Any

19198

0

1909.8000

1198

-2

1989.7925

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.3 NB-IoT FDD reference test frequencies for operating band 3

Table 8.1.3.1.1.3-1: NB-IoT standalone Test frequencies for operating band 3

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

19201

0

1710.1

1201

-0.5

1805.1

Mid Range

19575

0

1747.5

1575

-0.5

1842.5

High Range

19949

0

1784.9

1949

-0.5

1879.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.3-2: NB-IoT in-band Test frequencies for operating band 3

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

19206

0

1710.6000

1206

-2

1805.5925

Low Range2

19260

-2

1715.9900

1260

-1

1810.9975

Low Range3

19269

-2

1716.8900

1269

-1

1811.8975

Mid Range1

19566

0

1746.6000

1566

-2

1841.5925

Mid Range2

19585

-2

1748.4900

1585

-1

1843.4975

Mid Range3

19594

-2

1749.3900

1594

-1

1844.3975

High Range1

19944

0

1784.4000

1944

1

1879.4075

High Range2

19910

-2

1780.9900

1910

-1

1875.9975

High Range3

19919

-2

1781.8900

1919

-1

1876.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.3-3: NB-IoT guard-band Test frequencies for operating band 3

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

19201

0

1710.1000

1201

1

1805.1075

Mid Range

5

19551

0

1745.1000

1551

1

1840.1075

10

19621

0

1752.1000

1621

1

1847.1075

High Range

Any

19949

0

1784.9000

1949

-2

1879.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.4 NB-IoT FDD reference test frequencies for operating band 4

Table 8.1.3.1.1.4-1: NB-IoT standalone Test frequencies for operating band 4

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

19951

0

1710.1

1951

-0.5

2110.1

Mid Range

20175

0

1732.5

2175

-0.5

2132.5

High Range

20399

0

1754.9

2399

-0.5

2154.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.4-1a: NB-IoT standalone Test frequencies for operating band 4 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

19952

0

1710.2

1952

-0.5

2110.2

Mid Range

20175

0

1732.5

2175

-0.5

2132.5

High Range

20398

0

1754.8

2398

-0.5

2154.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.4-2: NB-IoT in-band Test frequencies for operating band 4

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

19957

0

1710.7000

1957

-2

2110.6925

Low Range2

20010

-2

1715.9900

2010

-1

2115.9975

Low Range3

20019

-2

1716.8900

2019

-1

2116.8975

Mid Range1

20166

0

1731.6000

2166

-2

2131.5925

Mid Range2

20185

-2

1733.4900

2185

-1

2133.4975

Mid Range3

20194

-2

1734.3900

2194

-1

2134.3975

High Range1

20393

0

1754.3000

2393

1

2154.3075

High Range2

20360

-2

1750.9900

2360

-1

2150.9975

High Range3

20369

-2

1751.8900

2369

-1

2151.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.4-2a: NB-IoT in-band Test frequencies for operating band 4 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

19957

0

1710.7000

1957

-2

2110.6925

Low Range2

20010

-2

1715.9900

2010

-1

2115.9975

Low Range3

20019

-2

1716.8900

2019

-1

2116.8975

Mid Range1

20166

0

1731.6000

2166

-2

2131.5925

Mid Range2

20185

-2

1733.4900

2185

-1

2133.4975

Mid Range3

20194

-2

1734.3900

2194

-1

2134.3975

High Range1

20393

0

1754.3000

2393

1

2154.3075

High Range2

20360

-2

1750.9900

2360

-1

2150.9975

High Range3

20369

-2

1751.8900

2369

-1

2151.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.4-3: NB-IoT guard-band Test frequencies for operating band 4

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

19951

0

1710.1000

1951

1

2110.1075

Mid Range

5

20151

0

1730.1000

2151

1

2130.1075

10

20221

0

1737.1000

2221

1

2137.1075

High Range

Any

20399

0

1754.9000

2399

-2

2154.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.4-3a: NB-IoT guard-band Test frequencies for operating band 4 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

19952

0

1710.2000

1952

1

2110.2075

Mid Range

5

20151

0

1730.1000

2151

1

2130.1075

10

20221

0

1737.1000

2221

1

2137.1075

High Range

Any

20398

0

1754.8000

2398

-2

2154.7925

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.5 NB-IoT FDD reference test frequencies for operating band 5

Table 8.1.3.1.1.5-1: NB-IoT standalone Test frequencies for operating band 5

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

20401

0

824.1

2401

-0.5

869.1

Mid Range

20525

0

836.5

2525

-0.5

881.5

High Range

20649

0

848.9

2649

-0.5

893.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.5-1a: NB-IoT standalone Test frequencies for operating band 5 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

20402

0

824.2

2402

-0.5

869.2

Mid Range

20525

0

836.5

2525

-0.5

881.5

High Range

20648

0

848.8

2648

-0.5

893.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.5-2: NB-IoT in-band Test frequencies for operating band 5

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

20406

0

824.6000

2406

-2

869.5925

Low Range2

20460

-2

829.9900

2460

-1

874.9975

Low Range3

20469

-2

830.8900

2469

-1

875.8975

Mid Range1

20516

0

835.6000

2516

-2

880.5925

Mid Range2

20535

-2

837.4900

2535

-1

882.4975

Mid Range3

20544

-2

838.3900

2544

-1

883.3975

High Range1

20644

0

848.4000

2644

1

893.4075

High Range2

20610

-2

844.9900

2610

-1

889.9975

High Range3

20619

-2

845.8900

2619

-1

890.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.5-2a: NB-IoT in-band Test frequencies for operating band 5 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

20406

0

824.6000

2406

-2

869.5925

Low Range2

20460

-2

829.9900

2460

-1

874.9975

Low Range3

20469

-2

830.8900

2469

-1

875.8975

Mid Range1

20516

0

835.6000

2516

-2

880.5925

Mid Range2

20535

-2

837.4900

2535

-1

882.4975

Mid Range3

20544

-2

838.3900

2544

-1

883.3975

High Range1

20644

0

848.4000

2644

1

893.4075

High Range2

20610

-2

844.9900

2610

-1

889.9975

High Range3

20619

-2

845.8900

2619

-1

890.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.5-3: NB-IoT guard-band Test frequencies for operating band 5

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

20401

0

824.1000

2401

1

869.1075

Mid Range

5

20501

0

834.1000

2501

1

879.1075

10

20571

0

841.1000

2571

1

886.1075

High Range

Any

20649

0

848.9000

2649

-2

893.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.5-3a: NB-IoT guard-band Test frequencies for operating band 5 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

20402

0

824.2000

2402

1

869.2075

Mid Range

5

20501

0

834.1000

2501

1

879.1075

10

20571

0

841.1000

2571

1

886.1075

High Range

Any

20648

0

848.8000

2648

-2

893.7925

NOTE 1: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.6 Void

8.1.3.1.1.7 NB-IoT FDD reference test frequencies for operating band 7

Table 8.1.3.1.1.7-1: NB-IoT standalone Test frequencies for operating band 7

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

20751

0

2500.1

2751

-0.5

2620.1

Mid Range

21100

0

2535.0

3100

-0.5

2655.0

High Range

21449

0

2569.9

3449

-0.5

2689.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.7-2: NB-IoT in-band Test frequencies for operating band 7

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

20757

0

2500.7000

2757

-2

2620.6925

Low Range2

20810

-2

2505.9900

2810

-1

2625.9975

Low Range3

20819

-2

2506.8900

2819

-1

2626.8975

Mid Range

21091

0

2534.1000

3091

-2

2654.0925

Mid Range2

21110

-2

2535.9900

3110

-1

2655.9975

Mid Range3

21119

-2

2536.8900

3119

-1

2656.8975

High Range

21443

0

2569.3000

3443

1

2689.3075

High Range2

21410

-2

2565.9900

3410

-1

2685.9975

High Range3

21419

-2

2566.8900

3419

-1

2686.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.7-3: NB-IoT guard-band Test frequencies for operating band 7

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

20751

0

2500.1000

2751

1

2620.1075

Mid Range

5

21076

0

2532.6000

3076

1

2652.6075

10

21146

0

2539.6000

3146

1

2659.6075

High Range

Any

21449

0

2569.9000

3449

-2

2689.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.8 NB-IoT FDD reference test frequencies for operating band 8

Table 8.1.3.1.1.8-1: NB-IoT standalone Test frequencies for operating band 8

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

21451

0

880.1

3451

-0.5

925.1

Mid Range

21625

0

897.5

3625

-0.5

942.5

High Range

21799

0

914.9

3799

-0.5

959.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.8-2: NB-IoT in-band Test frequencies for operating band 8

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

21456

0

880.6000

3456

-2

925.5925

Low Range2

21510

-2

885.9900

3510

-1

930.9975

Low Range3

21519

-2

886.8900

3519

-1

931.8975

Mid Range

21616

0

896.6000

3616

-2

941.5925

Mid Range2

21635

-2

898.4900

3635

-1

943.4975

Mid Range3

21644

-2

899.3900

3644

-1

944.3975

High Range

21794

0

914.4000

3794

1

959.4075

High Range2

21760

-2

910.9900

3760

-1

955.9975

High Range3

21769

-2

911.8900

3769

-1

956.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.8-3: NB-IoT guard-band Test frequencies for operating band 8

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

21451

0

880.1000

3451

1

925.1075

Mid Range

5

21601

0

895.1000

3601

1

940.1075

10

21671

0

902.1000

3671

1

947.1075

High Range

Any

21799

0

914.9000

3799

-2

959.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.9 to 8.1.3.1.1.10 Void

8.1.3.1.1.11 NB-IoT FDD reference test frequencies for operating band 11

Table 8.1.3.1.1.11-1: NB-IoT standalone Test frequencies for operating band 11

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

22751

0

1428.0

4751

-0.5

1476.0

Mid Range

22850

0

1437.9

4850

-0.5

1485.9

High Range

22949

0

1447.8

4949

-0.5

1495.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.11-2: NB-IoT in-band Test frequencies for operating band 11

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

22757

0

1428.6000

4757

-2

1476.5925

Low Range2

22810

-2

1433.8900

4810

-1

1481.8975

Low Range3

22819

-2

1434.7900

4819

-1

1482.7975

Mid Range1

22841

0

1437.0000

4841

-2

1484.9925

Mid Range2

22860

-2

1438.8900

4860

-1

1486.8975

Mid Range3

22869

-2

1439.7900

4869

-1

1487.7975

High Range1

22943

0

1447.2000

4943

1

1495.2075

High Range2

22910

-2

1443.8900

4910

-1

1491.8975

High Range3

22919

-2

1444.7900

4919

-1

1492.7975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.11-3: NB-IoT guard-band Test frequencies for operating band 11

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

22751

0

1428.0000

4751

1

1476.0075

Mid Range

22826

0

1435.5000

4826

1

1483.5075

High Range

22949

0

1447.8000

4949

-2

1495.7925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.12 NB-IoT FDD reference test frequencies for operating band 12

Table 8.1.3.1.1.12-1: NB-IoT standalone Test frequencies for operating band 12

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23011

0

699.1

5011

-0.5

729.1

Mid Range

23095

0

707.5

5095

-0.5

737.5

High Range

23179

0

715.9

5179

-0.5

745.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.12-1a: NB-IoT standalone Test frequencies for operating band 12 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23011

0

699.1

5011

-0.5

729.1

Mid Range

23095

0

707.5

5095

-0.5

737.5

High Range

23178

0

715.8

5178

-0.5

745.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.12-2: NB-IoT in-band Test frequencies for operating band 12

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23016

0

699.6000

5016

-2

729.5925

Low Range2

23070

-2

704.9900

5070

-1

734.9975

Low Range3

23079

-2

705.8900

5079

-1

735.8975

Mid Range1

23086

0

706.6000

5086

-2

736.5925

Mid Range2

23105

-2

708.4900

5105

-1

738.4975

Mid Range3

23114

-2

709.3900

5114

-1

739.3975

High Range1

23174

0

715.4000

5174

1

745.4075

High Range2

23140

-2

711.9900

5140

-1

741.9975

High Range3

23149

-2

712.8900

5149

-1

742.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.12-2: NB-IoT in-band Test frequencies for operating band 12 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23016

0

699.6000

5016

-2

729.5925

Low Range2

23070

-2

704.9900

5070

-1

734.9975

Low Range3

23079

-2

705.8900

5079

-1

735.8975

Mid Range1

23086

0

706.6000

5086

-2

736.5925

Mid Range2

23105

-2

708.4900

5105

-1

738.4975

Mid Range3

23114

-2

709.3900

5114

-1

739.3975

High Range1

23174

0

715.4000

5174

1

745.4075

High Range2

23140

-2

711.9900

5140

-1

741.9975

High Range3

23149

-2

712.8900

5149

-1

742.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.12-3: NB-IoT guard-band Test frequencies for operating band 12

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

23011

0

699.1000

5011

1

729.1075

Mid Range

5

23071

0

705.1000

5071

1

735.1075

10

23141

0

712.1000

5141

1

742.1075

High Range

Any

23179

0

715.9000

5179

-2

745.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.12-3a: NB-IoT guard-band Test frequencies for operating band 12 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

23011

0

699.1000

5011

1

729.1075

Mid Range

5

23071

0

705.1000

5071

1

735.1075

10

23141

0

712.1000

5141

1

742.1075

High Range

Any

23178

0

715.8000

5178

-2

745.7925

NOTE 1: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.13 NB-IoT FDD reference test frequencies for operating band 13

Table 8.1.3.1.1.13-1: NB-IoT standalone Test frequencies for operating band 13

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23181

0

777.1

5181

-0.5

746.1

Mid Range

23230

0

782.0

5230

-0.5

751.0

High Range

23279

0

786.9

5279

-0.5

755.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.13-1a: NB-IoT standalone Test frequencies for operating band 13 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23181

0

777.1

5181

-0.5

746.1

Mid Range

23230

0

782.0

5230

-0.5

751.0

High Range

23278

0

786.8

5278

-0.5

755.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.13-2: NB-IoT in-band Test frequencies for operating band 13

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23187

0

777.7000

5187

-2

746.6925

Low Range2

23240

-2

782.9900

5240

-1

751.9975

Low Range3

23249

-2

783.8900

5249

-1

752.8975

Mid Range1

23221

0

781.1000

5221

-2

750.0925

Mid Range2

23240

-2

782.9900

5240

-1

751.9975

Mid Range3

23249

-2

783.8900

5249

-1

752.8975

High Range1

23273

0

786.3000

5273

1

755.3075

High Range2

23240

-2

782.9900

5240

-1

751.9975

High Range3

23249

-2

783.8900

5249

-1

752.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.13-2a: NB-IoT in-band Test frequencies for operating band 13 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23187

0

777.7000

5187

-2

746.6925

Low Range2

23240

-2

782.9900

5240

-1

751.9975

Low Range3

23249

-2

783.8900

5249

-1

752.8975

Mid Range1

23221

0

781.1000

5221

-2

750.0925

Mid Range2

23240

-2

782.9900

5240

-1

751.9975

Mid Range3

23249

-2

783.8900

5249

-1

752.8975

High Range1

23273

0

786.3000

5273

1

755.3075

High Range2

23240

-2

782.9900

5240

-1

751.9975

High Range3

23249

-2

783.8900

5249

-1

752.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.13-3: NB-IoT guard-band Test frequencies for operating band 13

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

23181

3

777.1150

5181

1

746.1075

Mid Range

5

23206

3

779.6150

5206

1

748.6075

10

23276

3

786.6150

5276

1

755.6075

High Range

Any

23279

-3

786.8850

5279

-2

755.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.13-3a: NB-IoT guard-band Test frequencies for operating band 13 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

23181

3

777.1150

5181

1

746.1075

Mid Range

5

23206

3

779.6150

5206

1

748.6075

10

23276

3

786.6150

5276

1

755.6075

High Range

Any

23278

-3

786.7850

5278

-2

755.7925

NOTE 1: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.14 NB-IoT FDD reference test frequencies for operating band 14

Table 8.1.3.1.1.14-1: NB-IoT standalone Test frequencies for operating band 14

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23281

0

788.1

5281

-0.5

758.1

Mid Range

23330

0

793.0

5330

-0.5

763.0

High Range

23379

0

797.9

5379

-0.5

767.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.14-2: NB-IoT in-band Test frequencies for operating band 14

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23287

0

788.7000

5287

-2

758.6925

Low Range2

23340

-2

793.9900

5340

-1

763.9975

Low Range3

23349

-2

794.8900

5349

-1

764.8975

Mid Range1

23321

0

792.1000

5321

-2

762.0925

Mid Range2

23340

-2

793.9900

5340

-1

763.9975

Mid Range3

23349

-2

794.8900

5349

-1

764.8975

High Range1

23373

0

797.3000

5373

1

767.3075

High Range2

23340

-2

793.9900

5340

-1

763.9975

High Range3

23349

-2

794.8900

5349

-1

764.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.14-3: NB-IoT guard-band Test frequencies for operating band 14

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

23281

3

788.1150

5281

1

758.1075

Mid Range

5

23306

3

790.6150

5306

1

760.6075

10

23376

3

797.6150

5376

1

767.6075

High Range

Any

23379

-3

797.8850

5379

-2

767.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.15 to 8.1.3.1.1.16 Void

8.1.3.1.1.17 NB-IoT FDD reference test frequencies for operating band 17

Table 8.1.3.1.1.17-1: NB-IoT standalone Test frequencies for operating band 17

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23731

0

704.1

5731

-0.5

734.1

Mid Range

23790

0

710.0

5790

-0.5

740.0

High Range

23849

0

715.9

5849

-0.5

745.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.17-1a: NB-IoT standalone Test frequencies for operating band 17 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23732

0

704.2

5732

-0.5

734.2

Mid Range

23790

0

710.0

5790

-0.5

740.0

High Range

23848

0

715.8

5848

-0.5

745.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.17-2: NB-IoT in-band Test frequencies for operating band 17

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23737

0

704.7000

5737

-2

734.6925

Low Range2

23790

-2

709.9900

5790

-1

739.9975

Low Range3

23799

-2

710.8900

5799

-1

740.8975

Mid Range1

23781

0

709.1000

5781

-2

739.0925

Mid Range2

23800

-2

710.9900

5800

-1

740.9975

Mid Range3

23809

-2

711.8900

5809

-1

741.8975

High Range1

23843

0

715.3000

5843

1

745.3075

High Range2

23810

-2

711.9900

5810

-1

741.9975

High Range3

23819

-2

712.8900

5819

-1

742.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.17-2a: NB-IoT in-band Test frequencies for operating band 17 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23737

0

704.7000

5737

-2

734.6925

Low Range2

23790

-2

709.9900

5790

-1

739.9975

Low Range3

23799

-2

710.8900

5799

-1

740.8975

Mid Range1

23781

0

709.1000

5781

-2

739.0925

Mid Range2

23800

-2

710.9900

5800

-1

740.9975

Mid Range3

23809

-2

711.8900

5809

-1

741.8975

High Range1

23843

0

715.3000

5843

1

745.3075

High Range2

23810

-2

711.9900

5810

-1

741.9975

High Range3

23819

-2

712.8900

5819

-1

742.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.17-3: NB-IoT guard-band Test frequencies for operating band 17

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23731

0

704.1000

5731

1

734.1075

Mid Range

23766

0

707.6000

5766

1

737.6075

High Range

23849

0

715.9000

5849

-2

745.8925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.17-3a: NB-IoT guard-band Test frequencies for operating band 17 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23732

0

704.2000

5732

1

734.2075

Mid Range

23766

0

707.6000

5766

1

737.6075

High Range

23848

0

715.8000

5848

-2

745.7925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.18 NB-IoT FDD reference test frequencies for operating band 18

Table 8.1.3.1.1.18-1: NB-IoT standalone Test frequencies for operating band 18

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23851

0

815.1

5851

-0.5

860.1

Mid Range

23925

0

822.5

5925

-0.5

867.5

High Range

23999

0

829.9

5999

-0.5

874.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.18-2: NB-IoT in-band Test frequencies for operating band 18

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

23857

0

815.7000

5857

-2

860.6925

Low Range2

23910

-2

820.9900

5910

-1

865.9975

Low Range3

23919

-2

821.8900

5919

-1

866.8975

Mid Range1

23916

0

821.6000

5916

-2

866.5925

Mid Range2

23935

-2

823.4900

5935

-1

868.4975

Mid Range3

23944

-2

824.3900

5944

-1

869.3975

High Range1

23993

0

829.3000

5993

1

874.3075

High Range2

23960

-2

825.9900

5960

-1

870.9975

High Range3

23969

-2

826.8900

5969

-1

871.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.18-3: NB-IoT guard-band Test frequencies for operating band 18

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

23851

0

815.1000

5851

1

860.1075

Mid Range

23901

0

820.1000

5901

1

865.1075

High Range

23999

0

829.9000

5999

-2

874.8925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.19 NB-IoT FDD reference test frequencies for operating band 19

Table 8.1.3.1.1.19-1: NB-IoT standalone Test frequencies for operating band 19

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

24001

0

830.1

6001

-0.5

875.1

Mid Range

24075

0

837.5

6075

-0.5

882.5

High Range

24149

0

844.9

6149

-0.5

889.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.19-2: NB-IoT in-band Test frequencies for operating band 19

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

24007

0

830.7000

6007

-2

875.6925

Low Range2

24060

-2

835.9900

6060

-1

880.9975

Low Range3

24069

-2

836.8900

6069

-1

881.8975

Mid Range1

24066

0

836.6000

6066

-2

881.5925

Mid Range2

24085

-2

838.4900

6085

-1

883.4975

Mid Range3

24094

-2

839.3900

6094

-1

884.3975

High Range1

24143

0

844.3000

6143

1

889.3075

High Range2

24110

-2

840.9900

6110

-1

885.9975

High Range3

24119

-2

841.8900

6119

-1

886.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.19-3: NB-IoT guard-band Test frequencies for operating band 19

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

24001

0

830.1000

6001

1

875.1075

Mid Range

24051

0

835.1000

6051

1

880.1075

High Range

24149

0

844.9000

6149

-2

889.8925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.20 NB-IoT FDD reference test frequencies for operating band 20

Table 8.1.3.1.1.20-1: NB-IoT standalone Test frequencies for operating band 20

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

24151

0

832.1

6151

-0.5

791.1

Mid Range

24300

0

847.0

6300

-0.5

806.0

High Range

24449

0

861.9

6449

-0.5

820.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.20-2: NB-IoT in-band Test frequencies for operating band 20

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

24157

0

832.7000

6157

-2

791.6925

Low Range2

24210

-2

837.9900

6210

-1

796.9975

Low Range3

24219

-2

838.8900

6219

-1

797.8975

Mid Range1

24291

0

846.1000

6291

-2

805.0925

Mid Range2

24310

-2

847.9900

6310

-1

806.9975

Mid Range3

24319

-2

848.8900

6319

-1

807.8975

High Range1

24443

0

861.3000

6443

1

820.3075

High Range2

24410

-2

857.9900

6410

-1

816.9975

High Range3

24419

-2

858.8900

6419

-1

817.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.20-3: NB-IoT guard-band Test frequencies for operating band 20

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

24151

3

832.1150

6151

1

791.1075

Mid Range

5

24276

3

844.6150

6276

1

803.6075

10

24346

3

851.6150

6346

1

810.6075

High Range

Any

24449

-3

861.8850

6449

-2

820.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.21 NB-IoT FDD reference test frequencies for operating band 21

Table 8.1.3.1.1.21-1: NB-IoT standalone Test frequencies for operating band 21

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

24451

0

1448.00

6451

-0.5

1496.00

Mid Range

24525

0

1455.40

6525

-0.5

1503.40

High Range

24599

0

1462.80

6599

-0.5

1510.80

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.21-2: NB-IoT in-band Test frequencies for operating band 21

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

24457

-3

1448.5850

6457

-2

1496.5925

Low Range2

24510

-2

1453.8900

6510

-1

1501.8975

Low Range3

24519

-2

1454.7900

6519

-1

1502.7975

Mid Range

24516

-3

1454.4850

6516

-2

1502.4925

Mid Range2

24535

-2

1456.3900

6535

-1

1504.3975

Mid Range3

24544

-2

1457.2900

6544

-1

1505.2975

High Range

24593

3

1462.2150

6593

1

1510.2075

High Range2

24560

-2

1458.8900

6560

-1

1506.8975

High Range3

24569

-2

1459.7900

6569

-1

1507.7975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.21-3: NB-IoT guard-band Test frequencies for operating band 21

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

24451

0

1448.0000

6451

1

1496.0075

Mid Range

5

24501

0

1453.0000

6501

1

1501.0075

10

24571

0

1460.0000

6571

1

1508.0075

High Range

Any

24599

0

1462.8000

6599

-2

1510.7925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.22 to 8.1.3.1.1.24 Void

8.1.3.1.1.25 NB-IoT FDD reference test frequencies for operating band 25

Table 8.1.3.1.1.25-1: NB-IoT standalone Test frequencies for operating band 25

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26041

0

1850.10

8041

-0.5

1930.1

Mid Range

26365

0

1882.50

8365

-0.5

1962.5

High Range

26689

0

1914.90

8689

-0.5

1994.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.25-1a: NB-IoT standalone Test frequencies for operating band 25 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26042

0

1850.20

8042

-0.5

1930.2

Mid Range

26365

0

1882.50

8365

-0.5

1962.5

High Range

26688

0

1914.80

8688

-0.5

1994.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.25-2: NB-IoT in-band Test frequencies for operating band 25

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

26046

0

1850.6000

8046

-2

1930.5925

Low Range2

26100

-2

1855.9900

8100

-1

1935.9975

Low Range3

26109

-2

1856.8900

8109

-1

1936.8975

Mid Range1

26356

0

1881.6000

8356

-2

1961.5925

Mid Range2

26375

-2

1883.4900

8375

-1

1963.4975

Mid Range3

26384

-2

1884.3900

8384

-1

1964.3975

High Range1

26684

0

1914.4000

8684

1

1994.4075

High Range2

26650

-2

1910.99

8650

-1

1990.9975

High Range3

26659

-2

1911.89

8659

-1

1991.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.25-2a: NB-IoT in-band Test frequencies for operating band 25 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

26046

0

1850.6000

8046

-2

1930.5925

Low Range2

26100

-2

1855.9900

8100

-1

1935.9975

Low Range3

26109

-2

1856.8900

8109

-1

1936.8975

Mid Range1

26356

0

1881.6000

8356

-2

1961.5925

Mid Range2

26375

-2

1883.4900

8375

-1

1963.4975

Mid Range3

26384

-2

1884.3900

8384

-1

1964.3975

High Range1

26684

0

1914.4000

8684

1

1994.4075

High Range2

26650

-2

1910.99

8650

-1

1990.9975

High Range3

26659

-2

1911.89

8659

-1

1991.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.25-3: NB-IoT guard-band Test frequencies for operating band 25

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26041

0

1850.1000

8041

1

1930.1075

Mid Range

26341

0

1880.1000

8341

1

1960.1075

High Range

26689

0

1914.9000

8689

-2

1994.8925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.25-3a: NB-IoT guard-band Test frequencies for operating band 25 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26041

0

1850.1000

8041

1

1930.1075

Mid Range

26341

0

1880.1000

8341

1

1960.1075

High Range

26688

0

1914.8000

8688

-2

1994.7925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.26 NB-IoT FDD reference test frequencies for operating band 26

Table 8.1.3.1.1.26-1: NB-IoT standalone Test frequencies for operating band 26

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26691

0

814.1

8691

-0.5

859.1

Mid Range

26865

0

831.5

8865

-0.5

876.5

High Range

27039

0

848.9

9039

-0.5

893.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.26-1a: NB-IoT standalone Test frequencies for operating band 26 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26692

0

814.2

8692

-0.5

859.2

Mid Range

26865

0

831.5

8865

-0.5

876.5

High Range

27038

0

848.8

9038

-0.5

893.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.26-2: NB-IoT in-band Test frequencies for operating band 26

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

26696

0

814.6000

8696

-2

859.5925

Low Range2

26750

-2

819.9900

8750

-1

864.9975

Low Range3

26759

-2

820.8900

8759

-1

865.8975

Mid Range1

26856

0

830.6000

8856

-2

875.5925

Mid Range2

26875

-2

832.4900

8875

-1

877.4975

Mid Range3

26884

-2

833.3900

8884

-1

878.3975

High Range1

27034

0

848.4000

9034

1

893.4075

High Range2

27000

-2

844.9900

9000

-1

889.9975

High Range3

27009

-2

845.8900

9009

-1

890.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.26-2a: NB-IoT in-band Test frequencies for operating band 26 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

26696

0

814.6000

8696

-2

859.5925

Low Range2

26750

-2

819.9900

8750

-1

864.9975

Low Range3

26759

-2

820.8900

8759

-1

865.8975

Mid Range1

26856

0

830.6000

8856

-2

875.5925

Mid Range2

26875

-2

832.4900

8875

-1

877.4975

Mid Range3

26884

-2

833.3900

8884

-1

878.3975

High Range1

27034

0

848.4000

9034

1

893.4075

High Range2

27000

-2

844.9900

9000

-1

889.9975

High Range3

27009

-2

845.8900

9009

-1

890.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.26-3: NB-IoT guard-band Test frequencies for operating band 26

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26691

0

814.1000

8691

1

859.1075

Mid Range

26841

0

829.1000

8841

1

874.1075

High Range

27039

0

848.9000

9039

-2

893.8925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.26-3a: NB-IoT guard-band Test frequencies for operating band 26 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

26692

0

814.2000

8692

1

859.2075

Mid Range

26841

0

829.1000

8841

1

874.1075

High Range

27038

0

848.8000

9038

-2

893.7925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.27 Void

8.1.3.1.1.28 NB-IoT FDD reference test frequencies for operating band 28

Table 8.1.3.1.1.28-1: NB-IoT standalone Test frequencies for operating band 28

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

27211

0

703.1

9211

-0.5

758.1

Mid Range

27435

0

725.5

9435

-0.5

780.5

High Range

27659

0

747.9

9659

-0.5

802.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.28-2: NB-IoT in-band Test frequencies for operating band 28

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

27216

0

703.6000

9216

-2

758.5925

Low Range2

27270

-2

708.9900

9270

-1

763.9975

Low Range3

27279

-2

709.8900

9279

-1

764.8975

Mid Range1

27426

0

724.6000

9426

-2

779.5925

Mid Range2

27420

-2

723.9900

9420

-1

778.9975

Mid Range3

27429

-2

724.8900

9429

-1

779.8975

High Range1

27654

0

747.4000

9654

1

802.4075

High Range2

27620

-2

743.9900

9620

-1

798.9975

High Range3

27629

-2

744.8900

9629

-1

799.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.28-3: NB-IoT guard-band Test frequencies for operating band 28

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

27211

0

703.1000

9211

1

758.1075

Mid Range

5

27411

0

723.1000

9411

1

778.1075

10

27456

0

727.6000

9456

1

782.6075

High Range

Any

27659

0

747.9000

9659

-2

802.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.29 to 8.1.3.1.1.30 Void

8.1.3.1.1.31 NB-IoT FDD reference test frequencies for operating band 31

Table 8.1.3.1.1.31-1: NB-IoT standalone Test frequencies for operating band 31

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

27761

0

452.60

9871

-0.5

462.6

Mid Range

27785

0

455.00

9895

-0.5

465

High Range

27809

0

457.40

9919

-0.5

467.4

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.31-2: NB-IoT in-band Test frequencies for operating band 31

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

27766

-3

453.0850

9876

-2

463.0925

Low Range2

27794

0

455.9000

9904

1

465.9075

Low Range3

27803

0

456.8000

9913

1

466.8075

Mid Range1

27776

-3

454.0850

9886

-2

464.0925

Mid Range2

27794

0

455.9000

9904

1

465.9075

Mid Range3

27803

0

456.8000

9913

1

466.8075

High Range1

27804

3

456.9150

9914

1

466.9075

High Range2

27794

0

455.9000

9904

1

465.9075

High Range3

27803

0

456.8000

9913

1

466.8075

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 5 MHz and NB-IoT PRB 17

NOTE 3: Related to LTE channel BW 5 MHz and NB-IoT PRB 22

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.31-3: NB-IoT guard-band Test frequencies for operating band 31

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

27761

0

452.6000

9871

1

462.6075

Mid Range

27761

0

452.6000

9871

1

462.6075

High Range

27809

0

457.4000

9919

-2

467.3925

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

8.1.3.1.1.32 to 8.1.3.1.1. 64 Void

8.1.3.1.1.65 NB-IoT FDD reference test frequencies for operating band 65

Table 8.1.3.1.1.65-1: NB-IoT standalone Test frequencies for operating band 65

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

131073

0

1920.1

65537

-0.5

2110.1

Mid Range

131522

0

1965.0

65986

-0.5

2155.0

High Range

131971

0

2009.9

66435

-0.5

2199.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

NOTE 2: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.65-2: NB-IoT in-band Test frequencies for operating band 65

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

131078

0

1920.6000

65542

-2

2110.5925

Low Range2

131132

-2

1925.9900

65596

-1

2115.9975

Low Range3

131141

-2

1926.8900

65605

-1

2116.8975

Mid Range1

131513

0

1964.1000

65977

-2

2154.0925

Mid Range2

131532

-2

1965.9900

65996

-1

2155.9975

Mid Range3

131541

-2

1966.8900

66005

-1

2156.8975

High Range1

131966

0

2009.4000

66430

1

2199.4075

High Range2

131932

-2

2005.9900

66396

-1

2195.9975

High Range3

131941

-2

2006.8900

66405

-1

2196.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.65-3: NB-IoT guard-band Test frequencies for operating band 65

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

131073

0

1920.1000

65537

1

2110.1075

Mid Range

5

131498

0

1962.6000

65962

1

2152.6075

10

131568

0

1969.6000

66032

1

2159.6075

High Range

Any

131971

0

2009.9000

66435

-2

2199.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

8.1.3.1.1.66 NB-IoT FDD reference test frequencies for operating band 66

Table 8.1.3.1.1.66-1: NB-IoT standalone Test frequencies for operating band 66

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

131973

0

1710.1

66437

-0.5

2110.1

Mid Range

132322

0

1745.0

66786

-0.5

2145.0

High Range

132671

0

1779.9

67135

-0.5

2179.9

High Range3

132421

0

1754.9

66885

-0.5

2154.9

High Range4

132571

0

1769.0

67035

-0.5

2169.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

NOTE 2: Only paired part of the band considered for NB-IoT

NOTE 3: Applicable to NB-IoT FDD MFBI where band 66 overlaps band 4

NOTE 4: Applicable to NB-IoT FDD MFBI where band 66 overlaps band 10

Table 8.1.3.1.1.66-1a: NB-IoT standalone Test frequencies for operating band 66 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

131974

0

1710.2

66438

-0.5

2110.2

Mid Range

132322

0

1745.0

66786

-0.5

2145.0

High Range

132670

0

1779.8

67134

-0.5

2179.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

NOTE 2: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.66-2: NB-IoT in-band Test frequencies for operating band 66

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

131978

0

1710.6000

66442

-2

2110.5925

Low Range2

132032

-2

1715.9900

66496

-1

2115.9975

Low Range3

132041

-2

1716.8900

66505

-1

2116.8975

Mid Range1

132313

0

1744.1000

66777

-2

2144.0925

Mid Range2

132432

-2

1755.9900

66896

-1

2155.9975

Mid Range3

132441

-2

1756.8900

66905

-1

2156.8975

High Range1

132666

0

1779.4000

67130

1

2179.4075

High Range2

132632

-2

1775.9900

67096

-1

2175.9975

High Range3

132641

-2

1776.8900

67105

-1

2176.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.66-2a: NB-IoT in-band Test frequencies for operating band 66 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

131978

0

1710.6000

66442

-2

2110.5925

Low Range2

132032

-2

1715.9900

66496

-1

2115.9975

Low Range3

132041

-2

1716.8900

66505

-1

2116.8975

Mid Range1

132313

0

1744.1000

66777

-2

2144.0925

Mid Range2

132432

-2

1755.9900

66896

-1

2155.9975

Mid Range3

132441

-2

1756.8900

66905

-1

2156.8975

High Range1

132666

0

1779.4000

67130

1

2179.4075

High Range2

132632

-2

1775.9900

67096

-1

2175.9975

High Range3

132641

-2

1776.8900

67105

-1

2176.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.66-3: NB-IoT guard-band Test frequencies for operating band 66

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

131973

0

1710.1000

66437

1

2110.1075

Mid Range

5

132298

0

1742.6000

66762

1

2142.6075

10

132468

0

1759.6000

66932

1

2159.6075

High Range

Any

132671

0

1779.9000

67135

-2

2179.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

Table 8.1.3.1.1.66-3a: NB-IoT guard-band Test frequencies for operating band 66 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

131974

0

1710.2000

66438

1

2110.2075

Mid Range

5

132298

0

1742.6000

66762

1

2142.6075

10

132468

0

1759.6000

66932

1

2159.6075

High Range

Any

132670

0

1779.8000

67134

-2

2179.7925

NOTE 1: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 2: Only paired part of the band considered for NB-IoT

8.1.3.1.1.67 to 8.1.3.1.1.69 Void

8.1.3.1.1.70 NB-IoT FDD reference test frequencies for operating band 70

Table 8.1.3.1.1.70-1: NB-IoT standalone Test frequencies for operating band 70

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

132973

0

1695.1

68337

-0.5

1995.1

Mid Range

133047

0

1702.5

68411

-0.5

2002.5

High Range

133121

0

1709.9

68485

-0.5

2009.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.70-2: NB-IoT in-band Test frequencies for operating band 70

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

132979

-3

1695.6850

68343

-2

1995.6925

Mid Range

3

133038

-3

1701.5850

68402

-2

2001.5925

10 PRB 30

133057

-2

1703.4900

68421

-1

2003.4975

10 PRB 35

133066

-2

1704.3900

68430

-1

2004.3975

High Range

Any

133115

3

1709.3150

68479

1

2009.3075

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

Table 8.1.3.1.1.70-3: NB-IoT guard-band Test frequencies for operating band 70

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

132973

0

1695.1000

68337

1

1995.1075

Mid Range

5

133023

0

1700.1000

68387

1

2000.1075

10

133093

0

1707.1000

68457

1

2007.1075

High Range

Any

133121

0

1709.9000

68485

-2

2009.8925

NOTE 1: Void

NOTE 2: Applicable to either 3.75 kHz or 15 kHz UL sub-carrier spacing

NOTE 3: Only paired part of the band considered for NB-IoT

8.1.3.1.1.71 NB-IoT FDD reference test frequencies for operating band 71

Table 8.1.3.1.1.71-1: NB-IoT standalone Test frequencies for operating band 71

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

133123

0

663.1000

68587

-0.5

617.1000

Mid Range

133297

0

680.5000

68761

-0.5

634.5000

High Range

133471

0

697.9000

68935

-0.5

651.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.71-1a: NB-IoT standalone Test frequencies for operating band 71 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

133124

0

663.2000

68588

-0.5

617.2000

Mid Range

133297

0

680.5000

68761

-0.5

634.5000

High Range

133470

0

697.8000

68934

-0.5

651.8000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.71-2: NB-IoT in-band Test frequencies for operating band 71

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

133129

0

663.7000

68593

-2

617.6925

Low Range2

133182

-2

668.9900

68646

-1

622.9975

Low Range3

133191

-2

669.8900

68655

-1

623.8975

Mid Range1

133288

0

679.6000

68752

-2

633.5925

Mid Range2

133307

-2

681.4900

68771

-1

635.4975

Mid Range3

133316

-2

682.3900

68780

-1

636.3975

High Range1

133465

0

697.3000

68929

1

651.3075

High Range2

133432

-2

693.9900

68896

-1

647.9975

High Range3

133441

-2

694.8900

68905

-1

648.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.71-2a: NB-IoT in-band Test frequencies for operating band 71 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

133129

0

663.7000

68593

-2

617.6925

Low Range2

133182

-2

668.9900

68646

-1

622.9975

Low Range3

133191

-2

669.8900

68655

-1

623.8975

Mid Range1

133288

0

679.6000

68752

-2

633.5925

Mid Range2

133307

-2

681.4900

68771

-1

635.4975

Mid Range3

133316

-2

682.3900

68780

-1

636.3975

High Range1

133465

0

697.3000

68929

1

651.3075

High Range2

133432

-2

693.9900

68896

-1

647.9975

High Range3

133441

-2

694.8900

68905

-1

648.8975

NOTE 1: Related to LTE channel BW 3 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.71-3: NB-IoT guard-band Test frequencies for operating band 71

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

133123

3

663. 1150

68587

1

617.1075

Mid Range

5

133273

3

678. 1150

68737

1

632.1075

10

133343

3

685. 1150

68807

1

639.1075

High Range

Any

133471

-3

697. 8850

68935

-2

651.8925

NOTE 1: Void.

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.71-3a: NB-IoT guard-band Test frequencies for operating band 71 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

133124

3

663. 2150

68588

1

617.2075

Mid Range

5

133273

3

678. 1150

68737

1

632.1075

10

133343

3

685. 1150

68807

1

639.1075

High Range

Any

133470

-3

697. 7850

68934

-2

651.7925

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.72 Void

8.1.3.1.1.73 NB-IoT FDD reference test frequencies for operating band 73

Table 8.1.3.1.1.73-1: NB-IoT standalone Test frequencies for operating band 73

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

133523

0

450.1000

68997

-0.5

461.1000

Mid Range

133547

0

452.5000

69011

-0.5

462.5000

High Range

133571

0

454.9000

69035

-0.5

464.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.73-2: NB-IoT in-band Test frequencies for operating band 73

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

133556

0

453.4000

69020

1

463.4000

Mid Range

133556

0

453.4000

69020

1

463.4000

High Range

133556

0

453.4000

69020

1

463.4000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

NOTE 2: Defined for 5 MHz LTE Cell Bandwidth.

Table 8.1.3.1.1.73-3: NB-IoT guard-band Test frequencies for operating band 73

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

133523

0

450.1000

68997

1

461.1000

Mid Range

5

133523

0

450.1000

68997

1

461.1000

High Range

Any

133571

0

454.9000

69035

1

464.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.74 to 8.1.3.1.1.84 Void

8.1.3.1.1.85 NB-IoT FDD reference test frequencies for operating band 85

Table 8.1.3.1.1.85-1: NB-IoT standalone Test frequencies for operating band 85

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134003

0

698,1000

70367

-0.5

728,1000

Mid Range

134082

0

706,0000

70446

-0.5

736,0000

High Range

134181

0

715,9000

70545

-0.5

745,9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.85-1a: NB-IoT standalone Test frequencies for operating band 85 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134004

0

698,2000

70368

-0.5

728,2000

Mid Range

134082

0

706,0000

70446

-0.5

736,0000

High Range

134180

0

715,8000

70544

-0.5

745,8000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.85-2: NB-IoT in-band Test frequencies for operating band 85

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

134062

-2

703,9900

70426

-1

733,9975

Low Range2

134071

-2

704,8900

70435

-1

734,8975

Mid Range1

134102

-2

707,9900

70466

-1

737,9975

Mid Range2

134111

-2

708,8900

70475

-1

738,8975

High Range1

134142

-2

711,9900

70506

-1

741,9975

High Range2

134151

-2

712,8900

70515

-1

742,8975

NOTE 1: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 3: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.85-2a: NB-IoT in-band Test frequencies for operating band 85 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

134062

-2

703,9900

70426

-1

733,9975

Low Range2

134071

-2

704,8900

70435

-1

734,8975

Mid Range1

134102

-2

707,9900

70466

-1

737,9975

Mid Range2

134111

-2

708,8900

70475

-1

738,8975

High Range1

134142

-2

711,9900

70506

-1

741,9975

High Range2

134151

-2

712,8900

70515

-1

742,8975

NOTE 1: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 3: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.85-3: NB-IoT guard-band Test frequencies for operating band 85

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

134098

0

707,6000

70462

1

737,6075

Mid Range

10

134138

0

711,6000

70502

1

741,6075

High Range

Any

134178

0

715,6000

70542

-2

745,6075

NOTE 1: Void.

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.85-3a: NB-IoT guard-band Test frequencies for operating band 85 with NS_04

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

134004

0

698.2000

70368

1

728.2075

Mid Range

10

134092

0

707.0000

70456

1

737.0075

High Range

Any

134180

0

715.8000

70544

-2

745.7925

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.86 FFS

8.1.3.1.1.87 NB-IoT FDD reference test frequencies for operating band 87

Table 8.1.3.1.1.87-1: NB-IoT standalone Test frequencies for operating band 87

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134183

0

410.1000

70547

-0.5

420.1000

Mid Range

134207

0

412.5000

70571

-0.5

422.5000

High Range

134231

0

414.9000

70595

-0.5

424.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.87-2: NB-IoT in-band Test frequencies for operating band 87

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134216

0

413.4000

70580

1

423.4000

Mid Range

134216

0

413.4000

70580

1

423.4000

High Range

134216

0

413.4000

70580

1

423.4000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

NOTE 2: Defined for 5 MHz LTE Cell Bandwidth.

Table 8.1.3.1.1.87-3: NB-IoT guard-band Test frequencies for operating band 87

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

134183

0

410.1000

70547

1

420.1000

Mid Range

5

134183

0

410.1000

70547

1

4210.1000

High Range

Any

134231

0

414.9000

70595

1

424.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.88 NB-IoT FDD reference test frequencies for operating band 88

Table 8.1.3.1.1.88-1: NB-IoT standalone Test frequencies for operating band 88

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134233

0

412.1000

70597

-0.5

422.1000

Mid Range

134257

0

414.5000

70621

-0.5

424.5000

High Range

134281

0

416.9000

70645

-0.5

426.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.88-2: NB-IoT in-band Test frequencies for operating band 88

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134266

0

415.4000

70630

1

425.4000

Mid Range

134266

0

415.4000

70630

1

425.4000

High Range

134266

0

415.4000

70630

1

425.4000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

NOTE 2: Defined for 5 MHz LTE Cell Bandwidth.

Table 8.1.3.1.1.88-3: NB-IoT guard-band Test frequencies for operating band 88

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

134233

0

412.1000

70597

1

422.1000

Mid Range

5

134233

0

412.1000

70597

1

422.1000

High Range

Any

134281

0

416.9000

70645

1

426.9000

NOTE 1: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.1.89 to 8.1.3.1.1.102 Void

8.1.3.1.1.103 NB-IoT FDD reference test frequencies for operating band 103

Table 8.1.3.1.1.103-1: NB-IoT standalone Test frequencies for operating band 103

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134283

0

787.1

70647

-0.5

757.1

Mid Range

134287

0

787.5

70651

-0.5

757.5

High Range

134291

0

787.9

70655

-0.5

757.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.103-1a: NB-IoT standalone Test frequencies for operating band 103 with NS_04

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

134284

0

787.2

70648

-0.5

757.2

Mid Range

134287

0

787.5

70651

-0.5

757.5

High Range

134290

0

787.8

70654

-0.5

757.8

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

8.1.3.1.2 NB-IoT TDD Mode Test frequencies

8.1.3.1.2.1 to 8.1.3.1.2.40 Void

8.1.3.1.2.41 NB-IoT TDD reference test frequencies for operating band 41

Table 8.1.3.1.1.41-1: NB-IoT standalone Test frequencies for operating band 41

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

39651

0

2496.1

39651

-0.5

2496.1

Mid Range

40620

0

2593.0

40620

-0.5

2593.0

High Range

41589

0

2689.9

41589

-0.5

2689.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.1.41-2: NB-IoT in-band Test frequencies for operating band 41

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

39657

0

2496.7000

39657

-2

2496.6925

Low Range2

39710

-2

2501.9900

39710

-1

2501.9975

Low Range3

39719

-2

2502.8900

39719

-1

2502.8975

Mid Range1

40611

0

2592.1000

40611

-2

2592.0925

Mid Range2

40630

-2

2593.9900

40630

-1

2593.9975

Mid Range3

40639

-2

2594.8900

40639

-1

2594.8975

High Range1

41583

0

2689.3000

41583

1

2689.3075

High Range2

41550

-2

2685.9900

41550

-1

2685.9975

High Range3

41559

-2

2686.8900

41559

-1

2686.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.1.41-3: NB-IoT guard-band Test frequencies for operating band 41

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

39651

3

2496.1150

39651

1

2496.1075

Mid Range

5

40596

3

2590.6150

40596

1

2590.6075

10

40666

3

2597.6150

40666

1

2597.6075

High Range

Any

41589

-3

2689.8850

41589

-2

2689.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.2.42 NB-IoT TDD reference test frequencies for operating band 42

Table 8.1.3.1.2.42-1: NB-IoT standalone Test frequencies for operating band 42

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

41591

0

3400.1

41591

-0.5

3400.1

Mid Range

42590

0

3500.0

42590

-0.5

3500.0

High Range

43589

0

3599.9

43589

-0.5

3599.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.2.42-2: NB-IoT in-band Test frequencies for operating band 42

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

41597

0

3400.7000

41597

-2

3400.6925

Low Range2

41650

-2

3405.9900

41650

-1

3405.9975

Low Range3

41659

-2

3406.8900

41659

-1

3406.8975

Mid Range1

42581

0

3499.1000

42581

-2

3499.0925

Mid Range2

42600

-2

3500.9900

42600

-1

3500.9975

Mid Range3

42609

-2

3501.8900

42609

-1

3501.8975

High Range1

43583

0

3599.3000

43583

1

3599.3075

High Range2

43550

-2

3595.9900

43550

-1

3595.9975

High Range3

43559

-2

3596.8900

43559

-1

3596.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.2.42-3: NB-IoT guard-band Test frequencies for operating band 42

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

41591

3

3400.1150

41591

1

3400.1075

Mid Range

5

42566

3

3497.6150

42566

1

3497.6075

10

42636

3

3504.6150

42636

1

3504.6075

High Range

Any

43589

-3

3599.8850

43589

-2

3599.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.1.2.43 NB-IoT TDD reference test frequencies for operating band 43

Table 8.1.3.1.2.43-1: NB-IoT standalone Test frequencies for operating band 43

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

39651

0

2496.1

39651

-0.5

2496.1

Mid Range

40620

0

2593.0

40620

-0.5

2593.0

High Range

41589

0

2689.9

41589

-0.5

2689.9

NOTE 1: Applicable to either 3.75 kHz or 15 kHz NB-IoT UL subcarrier spacing

Table 8.1.3.1.2.43-2: NB-IoT in-band Test frequencies for operating band 43

Test Frequency ID

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range1

43597

0

3600.7000

43597

-2

3600.6925

Low Range2

43650

-2

3605.9900

43650

-1

3605.9975

Low Range3

43659

-2

3606.8900

43659

-1

3606.8975

Mid Range1

44581

0

3699.1000

44581

-2

3699.0925

Mid Range2

44600

-2

3700.9900

44600

-1

3700.9975

Mid Range3

44609

-2

3701.8900

44609

-1

3701.8975

High Range1

45583

0

3799.3000

45583

1

3799.3075

High Range2

45550

-2

3795.9900

45550

-1

3795.9975

High Range3

45559

-2

3796.8900

45559

-1

3796.8975

NOTE 1: Related to LTE channel BW 5 MHz

NOTE 2: Related to LTE channel BW 10 MHz and NB-IoT PRB 30

NOTE 3: Related to LTE channel BW 10 MHz and NB-IoT PRB 35

NOTE 4: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

Table 8.1.3.1.2.43-3: NB-IoT guard-band Test frequencies for operating band 43

Test Frequency ID

LTE Cell Bandwidth [MHz]

NUL

MUL

Frequency of Uplink [MHz]

NDL

MDL

Frequency of Downlink [MHz]

Low Range

Any

43591

3

3600.1150

43591

1

3600.1075

Mid Range

5

44566

3

3697.6150

44566

1

3697.6075

10

44636

3

3704.6150

44636

1

3704.6075

High Range

Any

45589

-3

3799.8850

45589

-2

3799.8925

NOTE 1: Void

NOTE 2: Defined for NB-IoT UL subcarrier spacing 15 kHz. Also applicable for 3.75 kHz UL sub-carrier spacing

8.1.3.2 NB-IoT Radio conditions

8.1.3.2.1 NB-IoT Normal propagation condition

Same normal propagation condition as defined in clause 4.3.2.1 apply.

8.1.3.3 NB-IoT Physical channel allocations

8.1.3.3.1 NB-IoT Antennas

As the UE has one Rx antenna, the downlink signal is applied to it.

8.1.3.3.2 NB-IoT Downlink physical channels and physical signals

The Downlink Physical channels and Physical signals used and their relative powers are specified for either single or two SS Tx antenna in table 8.1.3.3.2-1. According to this table, no boosting needs to be signalled (as power ratios are fixed between NRS EPRE and all DL channels for a given number of DL antenna ports).

According to TS 36.213 [29] clause 16.2.2, if higher layer parameter operationModeInfo indicates ‘00’ for a cell, the ratio of NRS EPRE to CRS EPRE is given by the parameter nrs-CRS-PowerOffset if the parameter nrs-CRS-EPRE-Ratio is provided by higher layers, and the ratio of NRS EPRE to CRS EPRE may be assumed to be 0 dB if the parameter nrs-CRS-EPRE-Ratio is not provided by higher layers.

Table 8.1.3.3.2-1: NB-IoT Power allocation for OFDM symbols and reference signals (1 or 2 SS Tx antenna)

Physical Channel / Signal

EPRE Ratio

NPBCH

According to TS 36.213 [29] clause 16.2.2, a UE may assume the ratio of NPBCH EPRE to NRS EPRE among NPBCH REs (not applicable to NPBCH REs with zero EPRE) is 0 dB for an NB-IoT cell with one NRS antenna port and -3 dB for an NB-IoT cell with two NRS antenna ports.

NPSS

Power allocation for NPSS is defined as equal to NRS EPRE = -85 dBm/15 kHz in order to have a constant EPRE (an absolute value is used as there is no NRS transmission when NPSS is transmitted).

NSSS

Power allocation for NSSS is defined as equal to NRS EPRE = -85 dBm/15 kHz in order to have a constant EPRE (an absolute value is used as there is no NRS transmission when NPSS is transmitted).

NPDCCH

According to TS 36.213 [29] clause 16.2.2, a UE may assume the ratio of NPDCCH EPRE to NRS EPRE among NPDCCH REs (not applicable to NPDCCH REs with zero EPRE) is 0 dB for an NB-IoT cell with one NRS antenna port and -3 dB for an NB-IoT cell with two NRS antenna ports.

NPDSCH

According to TS 36.213 [29] clause 16.2.2, a UE may assume the ratio of NPDSCH EPRE to NRS EPRE among NPDSCH REs (not applicable to NPDSCH REs with zero EPRE) is 0 dB for an NB-IoT cell with one NRS antenna port and -3 dB for an NB-IoT cell with two NRS antenna ports.

NRS

– If the number of NRS antenna ports is one, the EPRE of NRS and the EPRE of all NB-IoT DL channels is the same

– If the number of NRS antenna ports is two, the EPRE per antenna port of NRS port is 3dB larger compared to the EPRE per antenna port of all NB-IoT DL channels

– This means no signalling support of power offsets

– The set of values for power offset between NRS and LTE CRS is {-6, -4.77, -3, -1.77, 0, 1, 1.23, 2, 3, 4, 4.23, 5, 6, 7, 8, 9} dB.

NWUS

According to TS 36.213 [29] clause 16.2.2, the ratio of NWUS EPRE to NRS EPRE is 0 dB.

8.1.3.3.3 NB-IoT Mapping of downlink physical channels and signals to physical resources

Parameters for mapping of NB-IoT downlink physical channels and signals are specified as follows:

Normal Cyclic Prefix

, Physical layer cell identity = 0 is used as the default physical layer cell identity

For RF testing, the mapping of DL physical channels to resource element is defined TS 36.521-1 [21] Annex C.1.

Table 8.1.3.3.3-1: NB-IoT Mapping of DL Physical Channels and Signals to Resource Elements (FDD)

Physical channel / signal

Time Domain Location

Frequency Domain Location

Note

NPBCH

– NPBCH is transmitted in subframe 0 in every radio frame

– NPBCH consists of 8 independently decodable blocks of 80 ms duration

– The time interval where MIB remains unchanged is 640 ms

– NPBCH does not use the first 3 symbols in a subframe in in-band operation.

– For stand-alone and guard-band, the first 3 symbols (of the subframe transmitting NPBCH) contain no NPBCH.

Occupies any of the 12 subcarriers not reserved for transmission of reference signals

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.4.4

NPSS

– NPSS is transmitted in subframe 5

– NPSS uses the last 11 OFDM symbols of subframes in which NB-PSS occurs for normal CP

– NB-IoT PSS/SSS do not use:

– the LTE PDCCH control region

– REs used by LTE CRS

– The periodicity of NPSS transmission is 10ms.

NPSS is mapped to sub-carriers #0-10 of the NB-IoT carrier

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.7.1.2

NSSS

– NSSS is transmitted in subframe 9

– NSSS uses the last 11 OFDM symbols of subframes in which NB-SSS occurs for normal CP

– NB-IoT PSS/SSS do not use:

– the LTE PDCCH control region

– REs used by LTE CRS

– NSSS periodicity is 20ms

The number of subcarriers for NSSS is 12

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.7.2.2

NPDCCH

– NPDCCH on a given NB-IoT carrier are not mapped to the subframes containing NPSS/NSSS/PBCH on that carrier

– NPDCCH are not be mapped onto resources elements used for NRS

– NPDCCH are not overlapped with PBCH, PSS, SSS, or CRS

– One or two NPDCCHs can be transmitted in a subframe.

– In in-band, first three OFDM symbols are not used for NPDCCH

– In stand-alone and guard-band, all OFDM symbols are available for NPDCCH

– NPDCCH and NPDSCH are multiplexed only based on TDM at subframe level

– It means that only cross subframe scheduling is supported

– The start of an NPDCCH search space is >=4ms after the end of the last NPDCCH search space

– NPDCCH is transmitted on an aggregation of one or two consecutive narrowband control channel elements (NCCEs), where a narrowband control channel element corresponds to 6 consecutive subcarriers in a subframe where NCCE 0 occupies subcarriers 0 through 5 and NCCE 1 occupies subcarriers 6 through 11.

– REG is not defined for NPDCCH

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.5.5

NPDSCH

– The start of NB-PDSCH transmission is >=4ms later than the end of its associated DL assignment

– NPDSCH on a given NB-IoT carrier are not mapped to the subframes containing NPSS/NSSS/PBCH on that carrier

– NPDSCH resources elements should be different from the ones used for NRS

– NPDSCH resources elements should be different from the ones used for CRS

Occupies any of the 12 subcarriers not reserved for transmission of reference signals

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.3.4

NRS

– Narrowband reference signals are transmitted in all NB-IoT downlink subframes in a cell supporting NPDSCH transmission.

– NRS is not transmitted in subframes that are not NB-IoT downlink subframes, except if these subframes contain NPBCH or NPDSCH carrying SystemInformationBlockType1-NB where NRS shall be transmitted.

– Narrowband reference signals are transmitted in subframes #0 and #4 and in subframes #9 not containing NSSS [when no NB-IoT downlink subframes configuration has not been established].

– The narrowband reference signals shall not be mapped to subframes containing NPSS or NSSS.

– NRS are transmitted on one or two antenna ports 0 to 1 (refer to Figure 10.2.6.2-1 in TS 36.211 [35]).

2 subcarriers per antenna port in any OFDM symbols where NRS is transmitted

NWUS

– NWUS and its associated NB-IoT paging occasion subframes are on the same NB-IoT carrier.

– NWUS shall not be transmitted in subframes #4 carrying SystemInformationBlockType1-NB, those subframes are counted in the NWUS mapping but are not used for transmission of NWUS.

The number of subcarriers for NWUS is 12. The same antenna port shall be used for all symbols of the NWUS within a subframe.

Mapping rule is specified in TS 36.211 [35] sub clause 10.2.6B.2

Table 8.1.3.3.3-2: NB-IoT Mapping of DL Physical Channels to Resource Elements (TDD)

Physical channel

Time Domain Location

Frequency Domain Location

Note

NPBCH

Same as in Table 8.1.3.3.3-1, except for

– NPBCH is transmitted in subframe 9 in every radio frame

Same as in Table 8.1.3.3.3-1

NPSS

Same as in Table 8.1.3.3.3-1

Same as in Table 8.1.3.3.3-1

NSSS

Same as in Table 8.1.3.3.3-1, except for

– NSSS is transmitted in subframe 0

Same as in Table 8.1.3.3.3-1

NPDCCH

Same as in Table 8.1.3.3.3-1, except for

– Except in a special subframe when NPDCCH is transmitted in more than one subframe,

– In a special subframe where the NPDCCH is transmitted in one subframe, NPDCCH are mapped into DwPTS

– In a special subframe where the NPDCCH is transmitted in more than one subframe, NPDCCH are not mapped to NRS locations when the subframe is not a special subframe.

Same as in Table 8.1.3.3.3-1

NPDSCH

Same as in Table 8.1.3.3.3-1, except for

– Except in a special subframe when >1, NPDSCH resources elements should be different from the ones used for NRS

– NPDSCH resources elements should be different from the ones used for CRS

– In a special subframe, if , NPDSCH are mapped into DwPTS

– In a special subframe, if , NPDSCH are not mapped to NRS locations in subframes which are not special subframes.

Same as in Table 8.1.3.3.3-1

NRS

Same as in Table 8.1.3.3.3-1, except for

– Narrowband reference signals are transmitted in subframes #9 and in subframes #0 not containing NSSS [when no ddNB-IoT downlink subframes configuration has not been established].

Same as in Table 8.1.3.3.3-1

8.1.3.3.4 NB-IoT Uplink physical channels and physical signals

The NB-IoT uplink setting in table 8.1.3.3.4-1 is used unless otherwise specified in a test case.

Table 8.1.3.3.4-1: NB-IoT Default Uplink setting

Unit

Channel bandwidth

200 kHz

Number of Tones

1

Sub-carrier spacing

kHz

15

8.1.3.3.5 NB-IoT Mapping of uplink physical channels and signals to physical resources

[FFS]

8.1.3.4 NB-IoT Signal levels

8.1.3.4.1 NB-IoT Downlink signal levels

The downlink power settings in table 8.1.3.4.1-1 are used unless otherwise specified in a test case.

Table 8.1.3.4.1-1: NB-IoT Default Downlink power levels

Unit

Channel bandwidth

200 kHz

Number of Tones

12

Channel BW Power

dBm

-74

NRS EPRE

dBm/15kHz

-85

Note 1: The channel bandwidth powers are informative, based on -85dBm/15kHz NRS_EPRE, then scaled according to the number of tones in DL and rounded to the nearest integer dBm value.

Note 2: The power level is specified at the UE Rx antenna

It is [FFS] whether there is a requirement to specify constant power throughout all OFDM symbols, and if so how unallocated Resource elements should be treated.

The default signal level uncertainty is +/-3dB at each test port, for any level specified. If the uncertainty value is critical for the test purpose a tighter uncertainty is specified for the related test case in TS 36.521-1 [21] Annex F or in TS 36.521-3 [34] Annex F

8.1.3.4.2 NB-IoT Uplink signal levels

[FFS]

8.1.3.5 NB-IoT Standard test signals

8.1.3.5.1 NB-IoT Downlink test signals

[FFS]

8.1.3.5.2 NB-IoT Uplink test signals

[FFS]

8.1.3.6 NB-IoT Physical layer parameters

8.1.3.6.1 NB-IoT Downlink physical layer parameters

8.1.3.6.1.1 NB-IoT Physical layer parameters for DCI format N0

Default NB-IoT physical layer parameters for DCI format N0 are specified in table 8.1.3.6.1.1-1.

Table 8.1.3.6.1.1-1: NB-IoT Physical layer parameters for DCI format N0

Parameter

Value

Value in binary

Flag for format N0/format N1differentiation

format N0

"0"

Subcarrier indication

0 if not specified othewise depending on test case

(6 bits as defined in section 16.5.1.1 of 36.213 [29])

Resource assignment

Depending on test parameters

(3 bits as defined in section 16.5.1.1 of 36.213 [29])

Scheduling delay

0
(2 bits as defined in section 16.5.1 of of 36.213 [29])

“00”

Modulation and coding scheme

Depending on test parameters

(4 bits as defined in section 16.5.1.2 of 36.213 [29])

Redundancy version

0
(1 bit as defined in clause 16.5.1.2 of 36.213 [29])

"0"

Repetition number

NRep = 1

(3 bits as defined in clause 16.5.1.2 of 36.213 [29])

“000”

New data indicator

Set for every data transmission/retransmission according to the rules specified in TS 36.321 [14]

(1 bit)

DCI subframe repetition number

R = 2 (according to NPDCCH configuration of Table 8.1.6.3-3)(2 bits as defined in section 16.6 in 36.213 [29])

“00”

HARQ process number

Mandatory present if 2 HARQ processes are configured in the UE, default value (HARQ process) "0". Otherwise not present(1 bit as defined in section 16.5.1.2 of 36.213 [29])

8.1.3.6.1.2 NB-IoT Physical layer parameters for DCI format N1

Default NB-IoT physical layer parameters for DCI format N1 are specified in table 8.1.3.6.1.2-1 for random access procedure initiated by a NPDCCH order, in table 8.1.3.6.1.2-2 for the scheduling of one NPDSCH codeword in one cell scrambled by RA-RNTI/C-RNTI and in table 8.1.3.6.1.2-2 for the scheduling of one NPDSCH codeword in one cell scrambled by G-RNTI.

Table 8.1.3.6.1.2-1: NB-IoT Physical layer parameters for DCI format N1 (for random access procedure initiated by a NPDCCH order)

Parameter

Value

Value in binary

Flag for format N0/format N1 differentiation

format N1

“1”

NPDCCH order indicator

1

“1”

Starting number of NPRACH repetitions

n1

2 bits as defined in section 16.3.1 of 36.213 [29])

“00”

Subcarrier indication of NPRACH

12

(6 bits as defined in section 16.3.1 of 36.213 [29])

“001100”

NOTE 1: All the remaining bits in format N1 are set to one

Table 8.1.3.6.1.2-2: NB-IoT Physical layer parameters for DCI format N1 (for the scheduling of one NPDSCH codeword in one cell scrambled by RA-RNTI/C-RNTI)

Parameter

Value

Value in binary

Flag for format N0/format N1 differentiation

format N1

“1”

NPDCCH order indicator

0

“0”

Scheduling delay

0

(3 bits as defined in clause16.4.1 of 36.213 [29])

“000”

Resource assignment

Depending on test parameters

(3 bits as defined in section 16.4.1.3 of 36.213 [29])

Modulation and coding scheme

Depending on test parameters

(4 bits as defined in section 16.4.1.5 of 36.213 [29])

Repetition number

NRep = 1

(4 bits as defined in section 16.4.1.3 of 36.213 [29])

“0000”

New data indicator

Set for every data transmission/retransmission according to the rules specified in TS 36.321 [14]

(1 bit)

HARQ-ACK resource

0 if not specified otherwise depending on test case

(4 bits as defined in section 16.4.2 of 36.213 [29])

DCI subframe repetition number

R = 2 (according to NPRACH configuration of Table 8.1.6.3-5) (2 bits as defined in section 16.6 in 36.213 [29])

“00”

HARQ process number

Mandatory present if 2 HARQ processes are configured in the UE, default value (HARQ process) "0". Otherwise not present

(1 bit as defined in section 16.4.1.5 of 36.213 [29])

Table 8.1.3.6.1.2-3: NB-IoT Physical layer parameters for DCI format N1 (for the scheduling of one NPDSCH codeword in one cell scrambled by G-RNTI)

Parameter

Value

Value in binary

Information for SC-MCCH change notification

0

(2 bit as defined in section 5.8a of 36.331 [17])

“00”

Scheduling delay

0

(3 bits as defined in clause16.4.1 of 36.213 [29])

“000”

Resource assignment

Depending on test parameters

(3 bits as defined in section 16.4.1.3 of 36.213 [29])

Modulation and coding scheme

Depending on test parameters

(4 bits as defined in section 16.4.1.5 of 36.213 [29])

Repetition number

NRep = 1

(4 bits as defined in section 16.4.1.3 of 36.213 [29])

“0000”

DCI subframe repetition number

R = 2 (according to SC-MTCH configuration of Table 8.1.6.1-15a)

(2 bits as defined in section 16.6 in 36.213 [29])

“00”

HARQ process number

Mandatory present if 2 HARQ processes are configured in the UE, default value (HARQ process) "0". Otherwise not present

(1 bit as defined in section 16.4.1.5 of 36.213 [29])

8.1.3.6.1.3 (Void)

8.1.3.6.1.4 (Void)

8.1.3.6.1.5 NB-IoT Physical layer parameters for DCI format N2

Default NB-IoT physical layer parameters for DCI format N2 are specified in table 8.1.3.6.1.5-1 for paging, in table 8.1.3.6.1.5-2 for direct indication and in table 8.1.3.6.1.5-3 for scheduling of one NPDSCH codeword carrying SC-MCCH in one cell.

Table 8.1.3.6.1.5-1: NB-IoT Physical layer parameters for DCI format N2 (for paging)

Parameter

Value

Value in binary

Flag for paging/direct indication differentiation

1

“1”

Resource assignment

Depending on test parameters

(3 bits as defined in section 16.4.1.3 of 36.213 [29])

Modulation and coding scheme (transport block 1)

Depending on test parameters

(4 bits as defined in section 16.4.1.5 of 36.213 [29])

Repetition number

NRep = 1

(4 bits as defined in section 16.4.1.3 of 36.213 [29])

“0000”

DCI subframe repetition number

R = 1 (according to PCCH configuration of Table 8.1.6.3-2)

(3 bits as defined in section 16.6 of 36.213 [29])

“000”

Table 8.1.3.6.1.5-2: NB-IoT Physical layer parameters for DCI format N2 (for direct indication)

Parameter

Value

Value in binary

Flag for paging/direct indication differentiation

0

“0”

Direct Indication information

1
(8 bits provide direct indication of system information update and other fields, as defined in 36.331 [17])

“00000001”

NOTE 1: Reserved information bits are added until the size is equal to that of format N2 with Flag=1

Table 8.1.3.6.1.5-3: NB-IoT Physical layer parameters for DCI format N2 (for one NPDSCH codeword carrying SC-MCCH in one cell)

Parameter

Value

Value in binary

Information for SC-MCCH change notification

0

(1 bit as defined in section 5.8a of 36.331 [17])

“0”

Resource assignment

Depending on test parameters

(3 bits as defined in section 16.4.1.3 of 36.213 [29])

Modulation and coding scheme (transport block 1)

Depending on test parameters

(4 bits as defined in section 16.4.1.5 of 36.213 [29])

Repetition number

NRep = 1

(4 bits as defined in section 16.4.1.3 of 36.213 [29])

“0000”

DCI subframe repetition number

R = 1 (according to SC-MCCH configuration of Table 8.1.4.3.3-7)

(3 bits as defined in section 16.6 of 36.213 [29])

“000”