Table 4.4.4-1: Default parameters for simulated UTRA cells

cell ID

Primary scrambling code for FDD

Cell parameters ID for TDD

Cell 5

100

0

Cell 7

150

4

Cell 8

200

8

Cell 9

250

12

Cell 37

300

16

Cell 38

350

20

Cell 39

400

24

Table 4.4.4-2: Default NAS parameters for simulated UTRA cells

PLMN

Location Area Identification

Routing Area Identification

TMSI

P-TMSI signature

MCC

MNC

LA#

LAC

RA#

RAC

Cell 5

(Note 1)

LAI-1

1

RAI-1

1

Arbitrarily selected according to TS 23.003

subclause 2.4 [2]

Arbitrarily selected according to TS 23.003

subclause 2.7 [2]

Cell 7

(Note 1)

LAI-1

1

RAI-1

1

Cell 8

(Note 1)

LAI-1

1

RAI-1

1

Cell 9

(Note 1)

LAI-1

1

RAI-1

1

Cell 37

(Note 1)

LAI-1

1

RAI-1

1

Cell 38

(Note 1)

LAI-1

1

RAI-1

1

Cell 39

(Note 1)

LAI-1

1

RAI-1

1

Note 1: Set to the same Mobile Country Code and Mobile Network Code stored in EFIMSI on the test USIM card (subclause 4.9.3).

4.4.4.1 Common contents of system information blocks for UTRA cells

– System Information Block type 19

The system information block type 19 contains Inter-RAT frequency and priority information to be used in the cell.

Table 4.4.4.1-1: System Information Block type 19

Derivation Path: 25.331 clause 11.3

Information Element

Value/remark

Comment

Condition

SysInfoType19 ::= SEQUENCE {

utra-PriorityInfoList SEQUENCE {

utra-ServingCell SEQUENCE {

priority

3

s-PrioritySearch1

0 (0dB)

s-PrioritySearch2

Not present

default value is 0

threshServingLow

0 (0dB)

}

utran-FDD-FrequencyList SEQUENCE (SIZE(1..maxNumFDDFreqs)) OF SEQUENCE {}

Not present

utran-TDD-FrequencyList SEQUENCE (SIZE(1..maxNumTDDFreqs)) OF SEQUENCE {}

Not present

gsm-PriorityInfoList SEQUENCE (SIZE (1..maxNumGSMCellGroup)) OF SEQUENCE {}

Not present

eutra-FrequencyAndPriorityInfoList SEQUENCE (SIZE (1..maxNumEUTRAFreqs)) OF SEQUENCE {

The same number of entries as the configured eutra carriers

For Signalling test cases, see table 6.3.1.7-1

n denotes the index of the entry

earfcn[n]

Downlink EARFCN under test

For Signalling test cases, see table 6.3.1.7-1

measurementBandwidth[n]

Set according to EUTRA band ChBw in Table 5.6-1 of TS36.104.

priority[n]

4

qRxLevMinEUTRA[n]

-53 (-106 dBm)

For signalling test cases

-70 (-140 dBm)

For RF/RRM test cases

threshXhigh[n]

2 (4 dB)

threshXlow[n]

1 (2 dB)

eutra-blackListedCellList[n]

Not present

eutraDetection[n]

TRUE

}

eutra-FrequencyAndPriorityInfoList

Not present

Band > 64

v920NonCriticalExtensions SEQUENCE {

QBASED

va80NonCriticalExtensions SEQUENCE {

Band > 64

vb30NonCriticalExtensions SEQUENCE {

vb50NonCriticalExtensions SEQUENCE {

sysInfoType19-vb50ext SEQUENCE {

numberOfApplicableEARFCN

0

eutra-FrequencyAndPriorityInfoExtensionList SEQUENCE (SIZE (1..maxNumEUTRAFreqs)) OF SEQUENCE {

earfcn

Downlink EARFCN under test

For Signalling test cases, see table 6.3.1.7-1

measurementBandwidth

Set according to EUTRA band ChBw in Table 5.6-1 of TS 36.104.

priority

4

qRxLevMinEUTRA

-53 (-106 dBm)

For signalling test cases

-70 (-140 dBm)

For RF/RRM test cases

threshXhigh

2 (4 dB)

threshXlow

1 (2 dB)

qqualMinEUTRA

Not present

threshXhigh2

Not present

threshXlow2

Not present

eutra-blackListedCellList

Not present

eutraDetection

TRUE

}

}

vb80NonCriticalExtensions SEQUENCE {}

}

}

}

sysInfoType19-v920ext SEQUENCE {

utra-PriorityInfoList-v920ext SEQUENCE {

threshServingLow2

7 (7dB)

default value is 0

}

eutra-FrequencyAndPriorityInfoList-v920ext (SIZE (1..maxNumEUTRAFreqs)) OF SEQUENCE {

qQualMinEUTRA[n]

-20 (-20dB)

threshXhigh2[n]

5 (5dB)

threshXlow2[n]

5 (5dB)

}

v920NonCriticalExtensions SEQUENCE {

Band > 64

va80NonCriticalExtensions SEQUENCE {

vb30NonCriticalExtensions SEQUENCE {

vb50NonCriticalExtensions SEQUENCE {

sysInfoType19-vb50ext SEQUENCE {

numberOfApplicableEARFCN

0

eutra-FrequencyAndPriorityInfoExtensionList SEQUENCE (SIZE (1..maxNumEUTRAFreqs)) OF SEQUENCE {

earfcn

Downlink EARFCN under test

For Signalling test cases, see table 6.3.1.7-1

measurementBandwidth

Set according to EUTRA band ChBw in Table 5.6-1 of TS 36.104.

priority

4

qRxLevMinEUTRA

-53 (-106 dBm)

For signalling test cases

-70 (-140 dBm)

For RF/RRM test cases

threshXhigh

2 (4 dB)

threshXlow

1 (2 dB)

qqualMinEUTRA

Not present

threshXhigh2

Not present

threshXlow2

Not present

eutra-blackListedCellList

Not present

eutraDetection

TRUE

}

}

vb80NonCriticalExtensions SEQUENCE {}

}

}

}

}

}

nonCriticalExtensions SEQUENCE {}

Not present

}

}

Condition

Explanation

QBASED

See the definition below table 4.4.3.2-3.

Band > 64

If band > 64 is selected

4.4.4.2 UTRA SIB scheduling for inter EUTRA – UTRA test

Table 4.4.4.2-1: UTRA SIB schedule

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB19

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

64

SEG_
COUNT

1

1

1

1

1

1

4

4

1

3

1

1

2

Table 4.4.4.2-2: UTRA SIB-repeat period

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB19

SIB19

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

MIB

SIB11

SIB11

SIB11

4.4.4.3 UTRA SIB scheduling for inter EUTRA – UTRA – GERAN test

Table 4.4.4.3-1: UTRA SIB schedule

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/

SIB5bis

SIB7

SIB11

SIB16

SIB18

SIB19

SIB Rep

8

16

128

128

64

64

128

32

128

128

128

128

Max. No of seg.

1

2

1

1

1

1

4

1

3

8

1

3

Table 4.4.4.3-2: UTRA SIB-repeat period

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SB1

MIB

SIB1

SIB18

SIB2

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB4

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SB1

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB11

SIB11

SIB11

Frame No / SIB_POS

64

66

68

70

72

74

76

78

Block Type

MIB

SB1

SB1

SIB16

MIB

SIB16

SIB16

SIB16

Frame No / SIB_POS

80

82

84

86

88

90

92

94

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB19

SIB4

Frame No / SIB_POS

96

98

100

102

104

106

108

110

Block Type

MIB

SB1

SB1

SIB16

MIB

SIB16

SIB16

SIB16

Frame No / SIB_POS

112

114

116

118

120

122

124

126

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB19

SIB19