4.8 Reference radio bearer configurations

36.5083GPPCommon test environments for User Equipment (UE) conformance testingEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Release 17TS

4.8.1 General

4.8.2 SRB and DRB parameters and combinations

4.8.2.1 SRB and DRB parameters

4.8.2.1.1 SRB configurations

Table 4.8.2.1.1-1: SRB-ToAddMod-DEFAULT

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

SRB-ToAddMod-DEFAULT ::= SEQUENCE {

srb-Identity

1

SRB1

2

SRB2

rlc-Config CHOICE {

defaultValue

}

logicalChannelConfig CHOICE {

defaultValue

}

}

Table 4.8.2.1.1-2: SRB4-ToAddMod-DEFAULT

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

SRB-ToAddMod-DEFAULT ::= SEQUENCE {

Srb-Identity

2

rlc-Config CHOICE {

am SEQUENCE {

ul-AM-RLC SEQUENCE {

t-PollRetransmit

ms45

pollPDU

infinity

pollByte

infinity

maxRetxThreshold

t4

}

dl-AM-RLC SEQUENCE {

t-Reordering

ms35

t-StatusProhibit

ms0

}

}

}

logicalChannelConfig CHOICE {

explicityValue ::= SEQUENCE {

ul-SpecificParameters SEQUENCE {

priority

15

prioritisedBitRate

infinity

bucketSizeDuration

ms50

logicalChannelGroup

0

}

}

}

srb-Identity-v1530

4

}

4.8.2.1.2 DRB PDCP configurations

4.8.2.1.2.1 DRB PDCP configurations for UM RLC

Table 4.8.2.1.2.1-1: PDCP-Config-DRB-UM

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

PDCP-Config-DRB-UM ::= SEQUENCE {

discardTimer

ms100

Suitable for real time services

rlc-AM SEQUENCE {}

Not present

rlc-UM SEQUENCE {

pdcp-SN-Size

Len12bits

}

headerCompression CHOICE {

notUsed

NULL

}

}

4.8.2.1.2.2 DRB PDCP configurations for AM RLC

Table 4.8.2.1.2.2-1: PDCP-Config-DRB-AM

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

PDCP-Config-DRB-AM ::= SEQUENCE {

discardTimer

Infinity

rlc-AM SEQUENCE {

statusReportRequired

TRUE

}

rlc-UM SEQUENCE {}

Not present

headerCompression CHOICE {

notUsed

NULL

}

ul-DataSplitDRB-ViaSCG-r12

TRUE

Uplink transmission of split DRB PDCP SDUs configured to be transmitted on the PSCell

DC_Setup_Split_DRB

t-Reordering-r12

ms200

ENUMERATED {ms0, ms20, ms40, ms60, ms80, ms100, ms120, ms140,

ms160, ms180, ms200, ms220, ms240, ms260, ms280, ms300,

ms500, ms750}

DC_Setup_Split_DRB

uplinkDataCompression-r15 SEQUENCE {

UDC

bufferSize-r15

kbyte2

ENUMERATED {kbyte2, kbyte4, kbyte8, spare1}

dictionary-r15

Not present

ENUMERATED {sip-SDP, operator}

}

}

Condition

Explanation

DC_Setup_Split_DRB

Setup of Split DRB

UDC

Setup of DRB with uplinkDataCompression

4.8.2.1.3 DRB RLC configurations

4.8.2.1.3.1 DRB UM RLC configurations

Table 4.8.2.1.3.1-1: RLC-Config-DRB-UM

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

RLC-Config-DRB-UM ::= CHOICE {

um-Bi-Directional SEQUENCE {

ul-UM-RLC SEQUENCE {

sn-FieldLength

Size10

}

dl-UM-RLC SEQUENCE {

sn-FieldLength

Size10

t-Reordering

ms50

ms50 provides sufficient margin

}

}

}

4.8.2.1.3.2 DRB AM RLC configurations

Table 4.8.2.1.3.2-1: RLC-Config-DRB-AM

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

RLC-Config-DRB-AM ::= CHOICE {

am SEQUENCE {

ul-AM-RLC SEQUENCE {

t-PollRetransmit

ms80

pollPDU

p128

pollByte

kB125

maxRetxThreshold

t4

}

dl-AM-RLC SEQUENCE {

t-Reordering

ms80

Is sufficient for 5 HARQ transmissions

t-StatusProhibit

Ms60

Should be equal to or smaller than t-PollRetransmit.

}

}

}

4.8.2.1.4 DRB Logical Channel configurations

Table 4.8.2.1.4-1: LogicalChannelConfig-DRB

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

LogicalChannelConfig-DRB ::= SEQUENCE {

ul-SpecificParameters SEQUENCE {

priority

6

HI

13

LO

prioritisedBitRate

kBps0

PBR is disabled.

bucketSizeDuration

ms100

logicalChannelGroup

1

HI

2

LO

}

}

Condition

Explanation

HI

Used for DRBs with high logical channel priority

LO

Used for DRBs with low logical channel priority

4.8.2.1.5 MAC configurations

Table 4.8.2.1.5-1: MAC-MainConfig-RBC

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

MAC-MainConfig-RBC ::= SEQUENCE {

ul-SCH-Config

Not present

SCell_AddMod

ul-SCH-Config SEQUENCE {

maxHARQ-Tx

n5

periodicBSR-Timer

sf20

Infinity

no_periodic_BSR_or_PHR

retxBSR-Timer

sf320

sf10240

no_periodic_BSR_or_PHR

ttiBundling

FALSE

}

drx-Config

Not present

NOT pc_FeatrGrp_5 or SCell_AddMod

drx-Config CHOICE {

pc_FeatrGrp_5 AND DRX_S

setup SEQUENCE {

onDurationTimer

psf2

psf5

For SIG and HalfDuplex

drx-InactivityTimer

psf100

drx-RetransmissionTimer

psf16

longDRX-CycleStartOffset CHOICE {

sf40 typical value in real network for real-time services.

sf40

4

For SIG

0

For RF

}

shortDRX

Not present

}

}

drx-Config CHOICE {

pc_FeatrGrp_5 AND DRX_L

setup SEQUENCE {

onDurationTimer

psf6

drx-InactivityTimer

psf1920

drx-RetransmissionTimer

psf16

longDRX-CycleStartOffset CHOICE {

sf1280 typical value in real network for best-effort services.

sf1280

4

For SIG

0

For RF

}

shortDRX

Not present

}

}

timeAlignmentTimerDedicated

sf750

shortTTI-AndSPT-r15

Not present

shortTTI-AndSPT-r15 CHOICE {

Short-TTI

setup SEQUENCE {

periodicBSR-Timer-r15

sf20

proc-Timeline-r15

nplus4set1

UE_ProcessingTimeline_Set1

nplus6set2

UE_ProcessingTimeline_ Set2

}

}

phr-Config CHOICE {

no_periodic_BSR_or_PHR

release

NULL

}

phr-Config

Not present

SCell_AddMod and RF

phr-Config CHOICE {

setup SEQUENCE {

periodicPHR-Timer

sf500

prohibitPHR-Timer

sf200

dl-PathlossChange

dB3

}

}

sr-ProhibitTimer-r9

Not present

mac-MainConfig-v1020

Not present

mac-MainConfig-v1020 SEQUENCE {

SCell_AddMod

sCellDeactivationTimer-r10

rf32

extendedBSR-Sizes-r10

setup

extendedPHR-r10

setup

}

stag-ToReleaseList-r11

Not present

stag-ToAddModList-r11

Not present

drx-Config-v1130

Not present

e-HARQ-Pattern-r12

Not present

dualConnectivityPHR

Not present

dualConnectivityPHR CHOICE {

SCG_Add_EN-DC

setup SEQUENCE {

phr-ModeOtherCG-r12

real

}

}

logicalChannelSR-Config-r12 CHOICE {}

Not present

extendedPHR2-r13

Not present

eDRX-Config-CycleStartOffset-r13 CHOICE {}

Not present

eDRX-Config-CycleStartOffset-r13 CHOICE {}

Not present

drx-Config-r13 CHOICE {}

Not present

}

Condition

Explanation

DRX_S

Used for DRX configuration with small DRX cycle length

DRX_L

Used for DRX configuration with large DRX cycle length

no_periodic_BSR_or_PHR

Used to disable BSR and PHR

For SIG

Used for DRX configuration in Protocol testing

For RF

Used for DRX configuration in RRM testing

SCell_AddMod

Addition or modification of SCell

HalfDuplex

Used during Type B HalfDuplexOperation

SCG_Add_EN-DC

Used during SCG addition of NR cell on EN-DC test cases

Short-TTI

When short TTI is used

UE_ProcessingTimeline_Set1

Used for UE capability supporting {subslot, subslot} and processing timeline Set1

UE_ProcessingTimeline_Set2

Used for UE capability supporting {subslot, subslot} and processing timeline Set2

Table 4.8.2.1.5-2: MAC-MainConfig-SRB

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

MAC-MainConfig-SRB ::= SEQUENCE {

ul-SCH-Config SEQUENCE {

maxHARQ-Tx

n5

periodicBSR-Timer

sf20

retxBSR-Timer

sf320

ttiBundling

FALSE

}

drx-Config CHOICE {

release

NULL

}

timeAlignmentTimerDedicated

sf750

phr-Config CHOICE {

setup SEQUENCE {

periodicPHR-Timer

sf500

prohibitPHR-Timer

sf200

dl-PathlossChange

dB3

}

}

}

4.8.2.1.6 Physical Layer configurations

Table 4.8.2.1.6-1: PhysicalConfigDedicated-DEFAULT

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

PhysicalConfigDedicated-DEFAULT ::= SEQUENCE {

pdsch-ConfigDedicated

PDSCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

Not present

RBC or RBC-HO or

SCell_AddMod

pucch-ConfigDedicated

PUCCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 and not (CE Mode A or CE Mode B)) or RBC-HO or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

Not present

RBC or

SCell_AddMod or

CEmodeA or CEmodeB

pusch-ConfigDedicated

PUSCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

Not present

RBC or RBC-HO or

SCell_AddMod

uplinkPowerControlDedicated

UplinkPowerControlDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

Not present

RBC or RBC-HO or

SCell_AddMod

tpc-PDCCH-ConfigPUCCH

Not present

SRB1 or

SCell_AddMod

TPC-PDCCH-Config-DEFAULT using condition PUCCH

See subclause 4.6.3

RBC or RBC-HO or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

tpc-PDCCH-ConfigPUSCH

Not present

SRB1

SCell_AddMod

TPC-PDCCH-Config-DEFAULT using condition PUSCH

See subclause 4.6.3

RBC or RBC-HO or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

cqi-ReportConfig

CQI-ReportConfig-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA or

PSCell_Mod or PSCell_Add_Split_DRB or PSCell_Add_SCG_DRB

CQI-ReportConfig- DEFAULT using condition CQI_PERIODIC

See subclause 4.6.3

(RBC or RBC-HO) and not RBC-HO-CA

Not present

CA

HalfDuplex

soundingRS-UL-ConfigDedicated

Not present

SRB1 or HO-TO-EUTRA

SCell_AddMod

PSCell_AddMod

HalfDuplex

SoundingRS-Ul-ConfigDedicated-DEFAULT

See subclause 4.6.3

RBC or RBC-HO

antennaInfo CHOICE {

explicitValue SEQUENCE {

2TX or 4TX

transmissionMode

tm3

codebookSubsetRestriction CHOICE {

n2TxAntenna-tm3

’11’

BIT STRING (SIZE (2))

2TX

n4TxAntenna-tm3

‘1111’

BIT STRING (SIZE (4))

4TX

}

ue-TransmitAntennaSelection CHOICE {

Release

NULL

}

}

defaultValue

NULL

}

schedulingRequestConfig

SchedulingRequest-Config-DEFAULT

See subclause 4.6.3

SRB1 or RBC-H or HO-TO-EUTRA

Not present

RBC

SCell_AddMod

PSCell_AddMod

cqi-ReportConfig-v920

Not present

antennaInfo-v920

Not present

antennaInfo-r10

Not present

antennaInfoUL-r10

Not present

cif-Presence-r10

FALSE

SCell_AddMod

Not present

cqi-ReportConfig-r10

CQI-ReportConfig-r10-DEFAULT

SCell_AddMod or RBC-HO-CA

Not present

csi-RS-Config-r10

Not present

pucch-ConfigDedicated-v1020

PUCCH-ConfigDedicated-v1020-DEFAULT

SCell_AddMod

pusch-ConfigDedicated-v1020

Not present

schedulingRequestConfig-v1020

Not present

soundingRS-UL-ConfigDedicated-v1020

Not present

soundingRS-UL-ConfigDedicatedAperiodic-r10

Not present

uplinkPowerControlDedicated-v1020

UplinkPowerControlDedicated-v1020-DEFAULT

SCell_AddMod and (TxD or SRSAp)

Not present

additionalSpectrumEmissionCA-r10

Not present

additionalSpectrumEmissionCA-r10

Not present

SCell_AddMod and Intra-BC CA

additionalSpectrumEmissionCA-r10 CHOICE {

SCell_AddMod and Inter-B CA and UL CA

setup SEQUENCE {

additionalSpectrumEmissionPCell-r10

Not present

}

}

epdcch-Config-r11

EPDCCH-Config-r11-DEFAULT

ePDCCH or (Not(RBC) and (CE Mode A or CE Mode B))

Not present

csi-RS-ConfigNZPToReleaseList-r11

Not present

csi-RS-ConfigNZPToAddModList-r11

Not present

csi-RS-ConfigNZPToAddModList-r11 SEQUENCE (SIZE (1..maxCSI-RS-NZP-r11)) OF {

1 entry

DL_CoMP

CSI-RS-ConfigNZP-r11[1]

CSI-RS-ConfigNZP-r11-DEFAULT

}

csi-RS-ConfigZPToReleaseList-r11

Not present

csi-RS-ConfigZPToAddModList-r11

Not present

csi-RS-ConfigZPToAddModList-r11 SEQUENCE (SIZE (1..maxCSI-RS-ZP-r11)) OF {

1 entry

DL_CoMP

CSI-RS-ConfigZP-r11[1]

CSI-RS-ConfigZP-r11-DEFAULT

}

pdsch-ConfigDedicated-v1130

PDSCH-ConfigDedicated-v1130-DEFAULT

DL_CoMP

Not present

cqi-ReportConfig-v1130

CQI-ReportConfig-v1130-DEFAULT

DL_CoMP

Not present

pusch-EnhancementsConfig-r14

PUSCH-EnhancementsConfig-r14-DEFAULT

eVoLTE

Not present

pucch-ConfigDedicated-v1130

PUCCH-ConfigDedicated-v1130-DEFAULT

UL_CoMP

Not present

pusch-ConfigDedicated-v1130

PUSCH-ConfigDedicated-v1130-DEFAULT

UL_CoMP

Not present

uplinkPowerControlDedicated-v1130

UplinkPowerControlDedicated-v1130-DEFAULT

UL_CoMP

Not present

cqi-ReportConfigPCell-v1250

CQI-ReportConfig-v1250-DEFAULT

DL 256QAM

Not present

uplinkPowerControlDedicated-v1250

Not present

pusch-ConfigDedicated-v1250

Not present

csi-RS-Config-v1250

Not present

pdsch-ConfigDedicated-v1280

Not present

pdsch-ConfigDedicated-v1310

Not present

pucch-ConfigDedicated-r13

Not present

PUCCH-ConfigDedicated- r13-DEFAULT

Not (RBC) and ( CEmodeA or CemodeB)

pusch-ConfigDedicated-r13

Not present

pdcch-CandidateReductions-r13

Not present

cqi-ReportConfig-v1310

Not present

soundingRS-UL-ConfigDedicated-v1310

Not present

soundingRS-UL-ConfigDedicatedUpPTsExt-r13

Not present

soundingRS-UL-ConfigDedicatedAperiodic-v1310

Not present

soundingRS-UL-ConfigDedicatedAperiodicUpPTsExt-r13

Not present

csi-RS-Config-v1310

Not present

ce-Mode-r13 CHOICE {}

Not present

ce-Mode-r13 CHOICE {

Not (RBC) and ( CEmodeA OR CemodeB)

Setup

ce-ModeA

CEmodeA

setup

ce-ModeB

CEmodeB

}

physicalConfigDedicatedSTTI-r15

Not present

physicalConfigDedicatedSTTI-r15 CHOICE {

Short-TTI

setup SEQUENCE{

antennaInfoDedicatedSTTI-r15 CHOICE {

setup SEQUENCE{

transmissionModeDL-MBSFN-r15

tm3

transmissionModeDL-nonMBSFN-r15

tm3

maxLayersMIMO-STTI-r15

fourLayers

slotSubslotPDSCH-TxDiv-2Layer-r15

Not present

slotSubslotPDSCH-TxDiv-4Layer-r15

Not present

}

}

antennaInfoUL-STTI-r15 SEQUENCE {

transmissionModeUL-STTI-r15

tm1

}

pucch-ConfigDedicated-v1530

Not present

schedulingRequestConfig-v1530

Not present

uplinkPowerControlDedicatedSTTI-r15 SEQUENCE{

accumulationEnabledSTTI-r15

TRUE

uplinkPower-CSIPayload

FALSE

}

semiOpenLoopSTTI-r15

Not present

slotOrSubslotPDSCH-Config-r15

SlotOrSubslotPDSCH-Config-r15-DEFAULT

slotOrSubslotPUSCH-Config-r15

SlotOrSubslotPUSCH-Config-r15-DEFAULT

spdcch-Config-r15

SPDCCH-Config-r15-DEFAULT

spucch-Config-r15

SPUCCH-Config-r15-DEFAULT

srs-DCI7-TriggeringConfig-r15

Not present

shortProcessingTime-r15

Not present

shortTTI-r15 SEQUENCE{

dl-STTI-Length-r15

slot

ul-STTI-Length-r15

slot

}

}

}

uplinkPowerControlDedicated-v1530

Not present

uplinkPowerControlDedicated-v1530

UplinkPowerControlDedicated-v1530-DEFAULT

Aerial UE

}

Note: For signalling test, table 6.6B.1.1.1-1 is applied.

Condition

Explanation

SRB1

Used at configuration of SRB1 during RRC connection (re-)establishment

RBC

Used at configuration of a radio bearer combination during SRB2+DRB establishment

2TX

Used for cells with two antenna ports

4TX

Used for cells with four antenna ports

RBC-HO

Used during Handover

RBC-HO-CA

Used during Handover when Carrier Aggregation is configured for the source cells

SCell_AddMod

Addition or modification of SCell

HO-TO-EUTRA

Inter-RAT handover to E-UTRA

ePDCCH

Used at configuration of ePDCCH

DL_CoMP

Used for DL CoMP

UL_CoMP

Used for UL CoMP

CA

For Carrier Aggregation Test cases

TxD

When PUCCH Transmission Diversity is performed.

SRSAp

Aperiodic SRS configured

Intra-BC CA

Intra-band contiguous Carrier Aggregation

Inter-B CA

Inter-band Carrier Aggregation

UL CA

When UL Carrier Aggregation is used.

PSCell_Mod

Modification of PSCell

PSCell_Add_Split_DRB

Add PSCell(s) and setup of Split DRB

PSCell_Add_SCG_DRB

Add PSCell(s) and setup of SCG DRB

CEmodeA

Used for CE mode A testing

CEmodeB

Used for CE mode B testing

HalfDuplex

Used during Type B HalfDuplexOperation

DL 256QAM

When DL 256QAM is used

eVoLTE

When VoLTE enhancement is used.

Aerial UE

For Aerial vehicles

Short-TTI

When short TTI is used

Table 4.8.2.1.6-1A: PhysicalConfigDedicated-eIMTA

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

PhysicalConfigDedicated-eIMTA ::= SEQUENCE {

pdsch-ConfigDedicated

PDSCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA

Not present

RBC or RBC-HO

SCell_AddMod

pucch-ConfigDedicated

PUCCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 or RBC-HO or HO-TO-EUTRA

Not present

RBC

SCell_AddMod

pusch-ConfigDedicated

PUSCH-ConfigDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA

Not present

RBC or RBC-HO

SCell_AddMod

uplinkPowerControlDedicated

UplinkPowerControlDedicated-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA

Not present

RBC or RBC-HO

SCell_AddMod

tpc-PDCCH-ConfigPUCCH

Not present

SRB1

SCell_AddMod

TPC-PDCCH-Config-DEFAULT using condition PUCCH

See subclause 4.6.3

RBC or RBC-HO or HO-TO-EUTRA

tpc-PDCCH-ConfigPUSCH

Not present

SRB1

SCell_AddMod

TPC-PDCCH-Config-DEFAULT using condition PUSCH

See subclause 4.6.3

RBC or RBC-HO or HO-TO-EUTRA

cqi-ReportConfig

CQI-ReportConfig-DEFAULT

See subclause 4.6.3

SRB1 or HO-TO-EUTRA

CQI-ReportConfig- DEFAULT using condition CQI_PERIODIC

See subclause 4.6.3

RBC or RBC-HO

Not present

CA

soundingRS-UL-ConfigDedicated

Not present

SRB1 or HO-TO-EUTRA

SCell_AddMod

SoundingRS-Ul-ConfigDedicated-DEFAULT

See subclause 4.6.3

RBC or RBC-HO

antennaInfo CHOICE {

explicitValue SEQUENCE {

2TX

transmissionMode

tm3

codebookSubsetRestriction CHOICE {

n2TxAntenna-tm3

’11’

BIT STRING (SIZE (2))

}

ue-TransmitAntennaSelection CHOICE {

Release

NULL

}

}

defaultValue

NULL

}

schedulingRequestConfig

SchedulingRequest-Config-DEFAULT

See subclause 4.6.3

SRB1 or RBC-H or HO-TO-EUTRA

Not present

RBC

SCell_AddMod

cqi-ReportConfig-v920

Not present

antennaInfo-v920

Not present

antennaInfo-r10

Not present

antennaInfoUL-r10

Not present

cif-Presence-r10

FALSE

SCell_AddMod

Not present

cqi-ReportConfig-r10

CQI-ReportConfig-r10-DEFAULT

SCell_AddMod

Not present

csi-RS-Config-r10

Not present

pucch-ConfigDedicated-v1020

PUCCH-ConfigDedicated-v1020-DEFAULT

SCell_AddMod

pusch-ConfigDedicated-v1020

Not present

schedulingRequestConfig-v1020

Not present

soundingRS-UL-ConfigDedicated-v1020

Not present

soundingRS-UL-ConfigDedicatedAperiodic-r10

Not present

uplinkPowerControlDedicated-v1020

UplinkPowerControlDedicated-v1020-DEFAULT

SCell_AddMod and (TxD or SRSAp)

Not present

additionalSpectrumEmissionCA-r10

Not present

additionalSpectrumEmissionCA-r10

Not present

SCell_AddMod and Intra-BC CA

additionalSpectrumEmissionCA-r10 CHOICE {

SCell_AddMod and Inter-B CA and UL CA

setup SEQUENCE {

additionalSpectrumEmissionPCell-r10

1 (CA_NS_01)

}

}

epdcch-Config-r11

EPDCCH-Config-r11- eIMTA

ePDCCH

Not present

csi-RS-ConfigNZPToReleaseList-r11

Not present

csi-RS-ConfigNZPToAddModList-r11

Not present

csi-RS-ConfigNZPToAddModList-r11 SEQUENCE (SIZE (1..maxCSI-RS-NZP-r11)) OF {

1 entry

DL_CoMP

CSI-RS-ConfigNZP-r11[1]

CSI-RS-ConfigNZP-r11-DEFAULT

}

csi-RS-ConfigZPToReleaseList-r11

Not present

csi-RS-ConfigZPToAddModList-r11

Not present

csi-RS-ConfigZPToAddModList-r11 SEQUENCE (SIZE (1..maxCSI-RS-ZP-r11)) OF {

1 entry

DL_CoMP

CSI-RS-ConfigZP-r11[1]

CSI-RS-ConfigZP-r11-DEFAULT

}

pdsch-ConfigDedicated-v1130

PDSCH-ConfigDedicated-v1130-DEFAULT

DL_CoMP

Not present

cqi-ReportConfig-v1130

CQI-ReportConfig-v1130-eIMTA

DL_CoMP

Not present

pucch-ConfigDedicated-v1130

PUCCH-ConfigDedicated-v1130-DEFAULT

UL_CoMP

Not present

pusch-ConfigDedicated-v1130

PUSCH-ConfigDedicated-v1130-DEFAULT

UL_CoMP

Not present

uplinkPowerControlDedicated-v1130

UplinkPowerControlDedicated-v1130-DEFAULT

UL_CoMP

Not present

antennaInfo-v1250

Not present

eimta-MainConfig-r12

EIMTA-MainConfig-r12-DEFAULT

eIMTA

Not present

eimta-MainConfigPCell-r12

EIMTA-MainConfigServCell-r12-DEFAULT

eIMTA

Not present

pucch-ConfigDedicated-v1250

PUCCH-ConfigDedicated-v1250-DEFAULT

eIMTA

Not present

cqi-ReportConfigPCell-v1250

CQI-ReportConfig-v1250 -DEFAULT

eIMTA

Not present

uplinkPowerControlDedicated-v1250

UplinkPowerControlDedicated-v1250-DEFAULT

eIMTA

Not present

pusch-ConfigDedicated-v1250

PUSCH-ConfigDedicated-v1250-DEFAULT

eIMTA

Not present

csi-RS-Config-v1250

Not present

}

Condition

Explanation

SRB1

Used at configuration of SRB1 during RRC connection (re-)establishment

RBC

Used at configuration of a radio bearer combination during SRB2+DRB establishment

2TX

Used for cells with two antenna ports

RBC-HO

Used during Handover

RBC-HO-CA

Used during Handover when Carrier Aggregation is configured for the source cells

SCell_AddMod

Addition or modification of SCell

HO-TO-EUTRA

Inter-RAT handover to E-UTRA

ePDCCH

Used at configuration of ePDCCH

DL_CoMP

Used for DL CoMP

UL_CoMP

Used for UL CoMP

CA

For Carrier Aggregation Test cases

TxD

When PUCCH Transmission Diversity is performed.

SRSAp

Aperiodic SRS configured

Intra-BC CA

Intra-band contiguous Carrier Aggregation

Inter-B CA

Inter-band Carrier Aggregation

UL CA

When UL Carrier Aggregation is used.

eIMTA

eIMTA cell environment

4.8.2.1.7 DRB configurations

Table 4.8.2.1.7-1: DRB-ToAddMod-DEFAULT(bid)

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

DRB-ToAddMod-DEFAULT(bid) ::= SEQUENCE {

bid is the bearer identity (1..8)

eps-BearerIdentity

bid+4

drb-Identity

bid

pdcp-Config

PDCP-Config-DRB-AM

AM

PDCP-Config-DRB-UM

UM

rlc-Config

RLC-Config-DRB-AM

AM

RLC-Config-DRB-UM

UM

logicalChannelIdentity

bid+2

logicalChannelConfig

LogicalChannelConfig-DRB using condition LO

UM

LogicalChannelConfig-DRB using condition HI

AM

}

Condition

Explanation

AM

Used for AM DRB

UM

Used for UM DRB

Table 4.8.2.1.7-2: DRB-ToAddMod-EN-DC-Split

Derivation Path: 36.331 clause 6.3.2

Information Element

Value/remark

Comment

Condition

DRB-ToAddMod-EN-DC-Split ::= SEQUENCE {

eps-BearerIdentity

6

drb-Identity

2

pdcp-Config

Not present

rlc-Config

RLC-Config-DRB-AM

logicalChannelIdentity

Not present

logicalChannelConfig

LogicalChannelConfig-DRB using condition HI

}

4.8.2.2 SRB and DRB combinations

4.8.2.2.1 Combinations on DL-SCH and UL-SCH

4.8.2.2.1.1 SRB1 and SRB2 for DCCH + n x AM DRB + m x UM DRB, where n=1..N and m=0..M

This SRB and DRB combination is setup with UE Registration procedure and the Generic Radio Bearer Establishment or Generic Radio Bearer Establishment, UE Test Mode Activated procedure using specific message content – the default RRCConnectionReconfiguration message with condition SRB2-DRB(n, m).

4.8.3 UTRA reference radio parameters and combinations

Table 4.8.3-1 defines UTRA reference radio parameters and combinations to be used in E-UTRA and UTRA inter-RAT test cases.

Table 4.8.3-1: UTRA reference radio parameters and combinations

Condition

Reference configuration

Comment

UTRA Speech

TS 34.108 subclause 6.10.2.4.1.4

Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

UTRA FDD PS RB

TS 34.108 subclause 6.10.2.4.1.26

Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

UTRA HSDPA RB

TS 34.108 subclause 6.10.2.4.5.1

Interactive or background / UL:64 DL: [max bit rate depending on UE category] / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

UTRA HSUPA/HSDPA RB

TS 34.108 subclause 6.10.2.4.6.3

Streaming or interactive or background / UL: [max bit rate depending on UE category and TTI] DL: [max bit rate depending on UE category] / PS RAB + UL: [max bit rate depending on UE category and TTI] DL: [max bit rate depending on UE category] SRBs for DCCH on E-DCH and HS-DSCH

UTRA PS RB + Speech

TS 34.108 subclause 6.10.2.4.1.40

Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + Interactive or background / UL:64 DL:64 kbps / PS RAB+ UL:3.4 DL: 3.4 kbps SRBs for DCCH

4.8.4 GERAN reference PDP context parameters

Table 4.8.4-1 defines GERAN reference PDP context parameters to be used in E-UTRA and GERAN inter-RAT test cases.

Table 4.8.4-1: GERAN reference PDP context parameters

Condition

Reference configuration

Comment

GPRS

TS 51.010-1 subclause 40.5, Test PDP context3.

Test PDP context3 is the default Test PDP context which is used in the GERAN Inter-RAT GPRS test cases where no particular Test PDP contexts are specified. Compression is always turned off if nothing else is stated explicitly in the test case.