6.7.5 OTA Operating band unwanted emission
37.145-23GPPActive Antenna System (AAS) Base Station (BS) conformance testingPart 2: radiated conformance testingRelease 17TS
6.7.5.1 Definition and applicability
Unless otherwise stated, for E-UTRA single band and MSR the operating band unwanted emission limits are defined from ΔfOBUE below the lowest frequency of each supported downlink operating band to the lower Base Station RF Bandwidth edge located at FBW RF,low and from the upper Base Station RF Bandwidth edge located at FBW RF,high up to ΔfOBUE above the highest frequency of each supported downlink operating band.
The requirements shall apply whatever the type of transmitter considered and for all transmission modes foreseen by the manufacturer’s specification.
For BS operating in bands n50, n51, n74, n75 and n76 additional emission limits that might be applicable outside OBUE frequency domain are specified in clause 6.7.5.5.4.6.
6.7.5.2 Minimum Requirement
For AAS BS in MSR operation the minimum requirement is defined in TS 37.105 [6], clause 9.7.5.2
For AAS BS in single RAT E-UTRA operation the minimum requirement is defined in TS 37.105 [6], clause 9.7.5.4.
This requirement does not apply to single RAT UTRA operation.
6.7.5.3 Test purpose
This test measures the emissions of the AAS BS, close to the assigned channel bandwidth of the wanted signal, while the AAS BS is in operation.
6.7.5.4 Method of test
6.7.5.4.1 Initial conditions
Test environment:
– normal; annex G.2.
RF channels to be tested for single carrier:
– B, M and T; see clause 4.12.1.
Base Station RF Bandwidth positions to be tested for multi-carrier:
– BRFBW, MRFBW and TRFBW in single-band operation; see clause 4.12.1; BRFBW_T’RFBW and B’RFBW_TRFBW in multi-band operation, see clause 4.12.1
6.7.5.4.2 Procedure
The following procedure for measuring TRP is based on the directional power measurements as described in Annex F. An alternative method to measure TRP is to use a characterized and calibrated reverberation chamber if so follow steps 1, 3, 4, 6, 9 and 10.
1) Place the AAS BS at the positioner.
2) Align the manufacturer declared coordinate system orientation (see table 4.10-1, D9.2) of the AAS BS with the test system.
3) The measurement devices characteristics shall be:
– detection mode: true RMS voltage or true power averaging.
The emission power should be averaged over an appropriate time duration to ensure the measurement is within the measurement uncertainty in Table 4.1.2.2-1.
4) Set the AAS BS to transmit:
a) For MSR:
– Set the AAS BS to transmit maximum power according to the applicable test configuration in clause 5 using the corresponding test models or set of physical channels in clause 4.12.
b) For E-UTRA:
– AAS BS declared to be capable of single carrier operation only, set the AAS BS to transmit a signal according to E-TM1.1 (clause 4.12.2) at manufacturer’s declared rated carrier TRP (Prated,c,TRP).
– For an AAS BS declared to be capable of multi-carrier and/or CA operation, set the set the AAS BS to transmit according to E-TM1.1 on all carriers configured using the applicable test configuration and corresponding power setting specified in clause 4.11.
5) Orient the positioner (and BS) in order that the direction to be tested aligns with the test antenna such that measurements to determine TRP can be performed (see annex F).
6) Sweep the centre frequency of the measurement filter in contiguous steps and measure emission power within the specified frequency ranges with the specified measurement bandwidth.
7) Repeat step 6-7 for all directions in the appropriated TRP measurement grid needed for TRPEstimate (see annex F).
8) Calculate TRPEstimate using the measurements made in Step 7.
9) Repeat the test for the remaining test cases:
a) For MSR with channel set-up according to clause 5 and clause 4.12.2.
b) For E-UTRA with the channel set-up according to E-TM 1.2
In addition, for multi-band RIB, the following steps shall apply:
10) For multi-band RIB and single band tests, repeat the steps above per involved band where single band test configurations and test models shall apply with no carrier activated in the other band.
6.7.5.5 Test Requirement
6.7.5.5.1 General
As a general rule, the resolution bandwidth of the measuring equipment should be equal to the measurement bandwidth. However, to improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth can be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.
6.7.5.5.2 MSR Band categories 1 and 3
For an AAS BS of Wide Area BS class operating in Band Category 1 or Band Category 3, the requirement applies outside the Base Station RF Bandwidth edges. In addition, for a Wide Area BS operating in non-contiguous spectrum, it applies inside any sub-block gap. In addition, for an AAS BS of Wide Area BS class operating in multiple bands, it applies inside any Inter RF Bandwidth gap.
For an AAS BS of Medium Range BS class operating in Band Category 1 the requirement applies outside the Base Station RF Bandwidth edges. In addition, for a Medium Range BS operating in non-contiguous spectrum, it applies inside any sub-block gap. In addition, for an AAS BS of Medium Range BS class operating in multiple bands, it applies inside any Inter RF Bandwidth gap.
For an AAS BS of Local Area BS class operating in Band Category 1 the requirement applies outside the Base Station RF Bandwidth edges. In addition, for a Local Area BS operating in non-contiguous spectrum, it applies inside any sub-block gap. In addition, for an AAS BS of Local Area BS class operating in multiple bands, it applies inside any Inter RF Bandwidth gap.
Outside the Base Station RF Bandwidth edges, emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.2-1 to 6.7.5.5.2-8 below, where:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3 dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is the offset to the frequency ΔfOBUE MHz outside the downlink operating band.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB, inside any Inter RF Bandwidth gaps with Wgap < 2×ΔfOBUE MHz, emissions shall not exceed the cumulative sum of the test requirements specified at the Base Station RF Bandwidth edges on each side of the Inter RF Bandwidth gap. The minimum requirement for Base Station RF Bandwidth edge is specified in Tables 6.7.5.5.2-1 to 6.7.5.5.2-8, where in this case:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3 dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the Inter RF Bandwidth gap divided by two.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB, the operating band unwanted emission limits apply also in a supported operating band without any carriers transmitted, in the case where there are carriers transmitted in another operating band. In this case where there is no carrier transmitted in an operating band, no cumulative limits are applied in the inter-band gap between a supported downlink band with carrier(s) transmitted and a supported downlink band without any carrier transmitted and
– In case the Inter RF Bandwidth gap between a supported downlink band with carrier(s) transmitted and a supported downlink band without any carrier transmitted is less than 2×ΔfOBUE MHz, f_offsetmax shall be the offset to the frequency ΔfOBUE MHz outside the outermost edges of the two supported downlink operating bands and the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause, shall apply across both supported downlink bands.
– In other cases, the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause for the largest frequency offset (Δfmax), shall apply from ΔfOBUE MHz below the lowest frequency, up to ΔfOBUE MHz above the highest frequency of the supported downlink operating band without any carrier transmitted.
Inside any sub-block gap for a RIB operating in non-contiguous spectrum, emissions shall not exceed the cumulative sum of the test requirements specified for the adjacent sub blocks on each side of the sub block gap. The minimum requirement for each sub block is specified in Tables 6.7.5.5.2-1 to 6.7.5.5.2-8, where in this case:
– Δf is the separation between the sub block edge frequency and the nominal -3 dB point of the measuring filter closest to the sub block edge frequency.
– f_offset is the separation between the sub block edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the sub block gap bandwidth divided by two.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
Applicability of Wide Area operating band unwanted emission requirements in tables 6.7.5.5.2-1/2, 6.7.5.5.2-2a and 6.7.5.5.2-2b is specified in table 6.7.5.5.2-0.
Note: Option 1 and Option 2 correspond to the Category B option 1/2 operating band unwanted emissions defined in the E-UTRA and NR specifications TS 36.104 [4] and TS 38.104 [36]. Option 2 also corresponds to the UTRA spectrum emission mask as defined in TS 25.104 [2].
Table 6.7.5.5.2-0: Applicability of operating band unwanted emission requirements for BC1 and BC3 Wide Area BS
NR band operation |
UTRA supported |
Applicable requirement table |
None |
Y/N |
6.7.5.5.2-1/2 (option 2) |
In certain regions (NOTE 2), band 1, 65 |
N |
6.7.5.5.2-1/2 (option 2) |
Any below 1 GHz |
N |
6.7.5.5.2-2a (option 1) |
Any above 1 GHz except for certain regions (NOTE 2), band 1, 65 |
N |
6.7.5.5.2-2b/2c (option 1) |
NOTE 1: Void NOTE 2: Applicable only for operation in regions where Category B limits as defined in ITU-R Recommendation SM.329 [16] are used for which category B option 2 operating band unwanted emissions requirements as defined in TS 36.104 [4] and TS 38.104 [33] are applied. |
Table 6.7.5.5.2-1: WA BS OBUE in BC1 and BC3 bands ≤ 3 GHz applicable for: BS not supporting NR; or BS supporting NR in Band n1 or n65 – option 2
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.2 MHz |
0.015 MHz ≤ f_offset < 0.215 MHz |
-3.2 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3.2-15(f_offset/MHz-0.215)dBm (Note 6) |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15.2 dBm (Note 6) |
30 kHz |
1 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
1.5 MHz ≤ f_offset < min(f_offsetmax, 10.5 MHz) |
-2.2 dBm (Note 6) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 5, 6) |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/MHz (for MSR multi-band TAB connector supporting multi-band operation, either this limit or -16dBm/100kHz with correspondingly adjusted f_offset shall apply for this frequency offset range for operating bands < 1 GHz). NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. NOTE 6: For MSR multi-band TAB connector supporting multi-band operation, either this limit or -16dBm/100kHz with correspondingly adjusted f_offset shall apply for this frequency offset range for operating bands < 1 GHz. |
Table 6.7.5.5.2-2: WA BS OBUE in BC1 and BC3 bands > 3 GHz applicable for: BS not supporting NR; or BS supporting NR in Band n1 or n65 – option 2
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.2 MHz |
0.015 MHz ≤ f_offset < 0.215 MHz |
-3 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3-15(f_offset/MHz-0.215)dBm |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15 dBm |
30 kHz |
1 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
1.5 MHz ≤ f_offset < min(f_offsetmax, 10.5 MHz) |
-2 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 5) |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-2a: WA BS OBUE in BC1 and BC3 bands ≤ 1 GHz applicable for: BS supporting NR and not supporting UTRA – option 1
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 6.7.5.5.2-2b: WA BS OBUE in BC1 and BC3 bands > 3 GHz applicable for: BS supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
4 dBm – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 5) |
1 MHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1 MHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. |
Table 6.7.5.5.2-2c: WA BS OBUE in BC1 and BC3 bands > 1GHz and ≤ 3 GHz applicable for: BS supporting NR, not supporting NR operation in Band n1 or n65, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 5) |
1 MHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1 MHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. |
Table 6.7.5.5.2-3: MR BS OBUE in BC1 bands ≤ 3 GHz applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and not supporting NR; or BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm supporting NR and UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz |
0.015 MHz ≤ f_offset < 0.615 MHz |
Prated,c,TRP – 56.2 dB – (5/3)*(f_offset – 0,015) dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
Prated,c,TRP – 51.2 dB-15*(f_offset – 0,015) dB |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
Prated,c,TRP – 63.2 dB |
30 kHz |
1 MHz ≤ Δf ≤ 2.6 MHz |
1.5 MHz ≤ f_offset < 3.1 MHz |
Prated,c,TRP – 50.2 dB |
1 MHz |
2.6 MHz ≤ Δf ≤ 5 MHz |
3.1 MHz ≤ f_offset < 5.5 MHz |
min(Prated,c,TRP – 50.2 dB, -4.2dBm) |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
5.5 MHz ≤ f_offset < min (f_offsetmax, 10.5 MHz) |
Prated,c,TRP –54.2 dB |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
Prated,c,TRP-56 dB |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be (Prated,c,TRP – 56 dB)/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-3a: MR BS OBUE in BC1 bands ≤ 3 GHz applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm BS, supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP-51.2dB-(7/5)*(f_offset-0,05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP-58.2dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP-60dB, -16dBm) (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -60dB, -16dBm)/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 6.7.5.5.2-4: Medium Range BS operating band unwanted emission mask (UEM)
in BC1 bands > 3 GHz applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and not supporting NR; or BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm supporting NR and UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz |
0.015 MHz ≤ f_offset < 0.615 MHz |
Prated,c,TRP – 56 dB – (5/3)*(f_offset – 0,015) dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
Prated,c,TRP – 51dB -15*(f_offset-0,015) dB |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
Prated,c,TRP – 63 dB |
30 kHz |
1 MHz ≤ Δf ≤ 2.6 MHz |
1.5 MHz ≤ f_offset < 3.1 MHz |
Prated,c,TRP –50 dB |
1 MHz |
2.6 MHz ≤ Δf ≤ 5 MHz |
3.1 MHz ≤ f_offset < 5.5 MHz |
min(Prated,c,TRP – 50 dB, -4 dBm) |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
5.5 MHz ≤ f_offset < min(f_offsetmax ,10.5 MHz) |
Prated,c,TRP –54 dB |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
Prated,c,TRP-56 dB |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be (Prated,c,TRP – 56 dB)/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-4a: MR BS OBUE in BC1 bands > 3 GHz applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm BS, supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 51dB – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP -58 dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP -60dB, -16dBm) (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -60dB, -16dBm)/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 6.7.5.5.2-5: MR BS OBUE in BC1 bands ≤ 3 GHz applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and not supporting NR; or BS with maximum output power Prated,c,TRP ≤ 40 dBm supporting NR and UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz |
0.015 MHz ≤ f_offset < 0.615 MHz |
-16.2 -5/3(f_offset/MHz – 0.015) dBm |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
-11.2 -15(f_offset/MHz – 0.015) dBm |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-23.2 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 5 MHz |
1.5 MHz ≤ f_offset < 5.5 MHz |
-10.2 dBm |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax,10 MHz) |
5.5 MHz ≤ f_offset < min(f_offsetmax,10.5 MHz) |
-14.2 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-16dBm (Note 5) |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-5a: MR BS OBUE in BC1 bands ≤ 3 GHz applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm, supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-11.2 dBm – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-18.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (Note 8) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20dBm/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 6.7.5.5.2-6: MR BS OBUE in BC1 bands > 3 GHz applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and not supporting NR; or BS with maximum output power Prated,c,TRP ≤ 40 dBm supporting NR and UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz |
0.015 MHz ≤ f_offset < 0.615 MHz |
-16 -5/3(f_offset/MHz – 0.015) dBm |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
-11 -15(f_offset/MHz – 0.015) dBm |
30 kHz |
(Note 3) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-23 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 5 MHz |
1.5 MHz ≤ f_offset < 5.5 MHz |
-10 dBm |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax,10 MHz) |
5.5 MHz ≤ f_offset < min(f_offsetmax,10.5 MHz) |
-14 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-16dBm (Note 5) |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: This frequency range ensures that the range of values of f_offset is continuous. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-6a: MR BS OBUE in BC1 bands > 3 GHz applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm, supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-11 dBm – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-18 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20dBm/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 6.7.5.5.2-7: LA BS OBUE in BC1 bands ≤ 3 GHz
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-19.2 dBm -7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-26.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (Note 5) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -28 dBm/100 kHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 3: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.2-8: LA BS OBUE in BC1 bands > 3 GHz
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Note 1, 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-19 dBm-7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-26 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (Note 5) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -28 dBm/100 kHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 3: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.3 MSR Band Category 2
For a RIB operating in Band Category 2 the requirement applies outside the Base Station RF Bandwidth edges. In addition, for a RIB operating in non-contiguous spectrum, it applies inside any sub-block gap.
Outside the Base Station RF Bandwidth edges, emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.3-1 to 6.7.5.5.3-8, where:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is the offset to the frequency ΔfOBUE MHz outside the downlink operating band.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB, inside any Inter RF Bandwidth gaps with Wgap < 2×ΔfOBUE MHz, emissions shall not exceed the cumulative sum of the test requirements specified at the Base Station RF Bandwidth edges on each side of the Inter RF Bandwidth gap. The minimum requirement for Base Station RF Bandwidth edge is specified in Tables 6.7.5.5.3-1 to 6.7.5.5.3-8, where in this case:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3 dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the Inter RF Bandwidth gap divided by two.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB and where there is no carrier transmitted in an operating band, no cumulative limits are applied in the inter-band gap between a supported downlink band with carrier(s) transmitted and a supported downlink band without any carrier transmitted and
– In case the inter-band gap between a supported downlink band with carrier(s) transmitted and a supported downlink band without any carrier transmitted less than is 2×ΔfOBUE MHz, f_offsetmax shall be the offset to the frequency ΔfOBUE MHz outside the outermost edges of the two supported downlink operating bands and the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause, shall apply across both supported downlink bands.
– In other cases, the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause for the largest frequency offset (Δfmax), shall apply from ΔfOBUE MHz below the lowest frequency, up to ΔfOBUE MHz above the highest frequency of the supported downlink operating band without any carrier transmitted.
Inside any sub-block gap for a RIB operating in non-contiguous spectrum, emissions shall not exceed the cumulative sum of the test requirement specified for the adjacent sub blocks on each side of the sub block gap. The minimum requirement for each sub block is specified in Tables 6.7.5.5.3-1 to 6.7.5.5.3-8, where in this case:
– Δf is the separation between the sub block edge frequency and the nominal -3 dB point of the measuring filter closest to the sub block edge.
– f_offset is the separation between the sub block edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the sub block gap bandwidth divided by two.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
Applicability of Wide Area operating band unwanted emission requirements in tables 6.7.5.5.3-1, 6.7.5.5.3-2a and 6.7.5.5.3-2b is specified in table 6.7.5.5.3-0.
Note: Option 1 and Option 2 correspond to the Category B option 1/2 operating band unwanted emissions defined in the E-UTRA and NR specifications TS 36.104 [4] and TS 38.104 [36]. Option 2 also corresponds to the UTRA spectrum emission mask as defined in TS 25.104 [2].
Table 6.7.5.5.3-0: Applicability of operating band unwanted emission requirements for BC2 Wide Area BS
NR band operation |
UTRA supported |
Applicable requirement table |
None |
Y/N |
6.7.5.5.3-1 (option 2) |
In certain regions (NOTE 2), band 3, 8 |
N |
6.7.5.5.3-1 (option 2) |
Any below 1 GHz except for, in certain regions (NOTE 2), band 8 |
N |
6.7.5.5.3-2a (option 1) |
Any above 1 GHz except for certain regions (NOTE 2), band 3 |
N |
6.7.5.5.3-2b (option 1) |
NOTE 1: Void NOTE 2: Applicable only for operation in regions where Category B limits as defined in ITU-R Recommendation SM.329 [16] are used for which category B option 2 operating band unwanted emissions requirements as defined in TS 36.104 [4] and TS 38.104 [33] are applied. |
Table 6.7.5.5.3-1: WA BS OBUE in BC2 bands applicable for: BS not supporting NR; or BS supporting NR in Band n3 or n8 – option 2
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2 and 3) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.2 MHz (Note 1) |
0.015 MHz ≤ f_offset < 0.215 MHz |
-3.2 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3.2-15(f_offset/MHz-0.215) dBm (Note 11) |
30 kHz |
(Note 8) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15.2 dBm (Note 11) |
30 kHz |
1 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
1.5 MHz ≤ f_offset < min(f_offsetmax, 10.5 MHz) |
-2.2 dBm (Note 11) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 10, 11) |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 6.7.5.5.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6 dBm/MHz (for MSR multi-band TAB connector, either this limit or -16dBm/100kHz with correspondingly adjusted f_offset shall apply for this frequency offset range for operating bands <1GHz). NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz operation the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 8: This frequency range ensures that the range of values of f_offset is continuous. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz. NOTE 11: For MSR multi-band TAB connector, either this limit or -16dBm/100kHz with correspondingly adjusted f_offset shall apply for this frequency offset range for operating bands < 1 GHz. |
Table 6.7.5.5.3-2: WA BS OBUE in BC2 bands applicable for: BS operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Note 2, 3 and 4) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
Max(15.8dBm-60(f_offset/MHz-0.015), -3.2 dBm) |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
Max(12.8dBm-160(f_offset/MHz-0.065), -3.2 dBm) |
30 kHz |
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 4: Void. NOTE 8: Void. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-2a: WA BS OBUE in BC2 bands ≤ 1 GHz applicable for: BS supporting NR, not operating NR in band n8, and not supporting UTRA – option 1
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz – 0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 10) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.7.5.5.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 4: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.3-2b: WA BS OBUE in BC2 bands > 1 GHz applicable for: BS supporting NR, not operating NR in band n3, and not supporting UTRA – option 1
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz – 0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 5) |
1 MHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1 MHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.7.5.5.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 4: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.3-3: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and not supporting NR; or BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm supporting NR with UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2 and 3) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz (Note 1) |
0.015 MHz ≤ f_offset < 0.615 MHz |
Prated,c,TRP-56.2dB-(5/3)*(f_offset-0,015)dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
Prated,c,TRP-51.2dB-15*(f_offset-0,215)dB |
30 kHz |
(Note 8) |
1.015 MHz ≤ f_offset < 1.5 MHz |
Prated,c,TRP – 63.2 dB |
30 kHz |
1 MHz ≤ Δf ≤ 2.8 MHz |
1.5 MHz ≤ f_offset < 3.3 MHz |
Prated,c,TRP – 50.2 dB |
1 MHz |
2.8 MHz ≤ Δf ≤ 5 MHz |
3.3 MHz ≤ f_offset < 5.5 MHz |
min(Prated,c,TRP – 50.2 dB, -4.2dBm) |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
5.5 MHz ≤ f_offset < min(f_offsetmax,10.5 MHz) |
Prated,c,TRP – 54.2 dB |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
Prated,c,TRP -56 dB (Note 10) |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.7.5.5.3-5 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be (Prated,c,TRP – 56 dB)/MHz. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 8: This frequency range ensures that the range of values of f_offset is continuous. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-3a: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm, supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 51.2dB – 7/5(f_offset/MHz-0.05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP -58.2dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP -60dB, -16dBm) (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -60dB, -16dBm)/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.7.5.5.3-5 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 4: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.3-4: Medium Range BS operating band unwanted emission mask (UEM)
in BC2 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and not supporting NR; or BS with maximum output power Prated,c,TRP ≤ 40 dBm supporting NR with UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2 and 3) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.6 MHz (Note 1) |
0.015 MHz ≤ f_offset < 0.615 MHz |
-16.2dBm-5/3(f_offset/MHz-0.015)dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615 MHz ≤ f_offset < 1.015 MHz |
-11.2dBm-15(f_offset/MHz-0.215)dB |
30 kHz |
(Note 8) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-23.2 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 5 MHz |
1.5 MHz ≤ f_offset < 5.5 MHz |
-10.2 dBm |
1 MHz |
5 MHz ≤ Δf ≤ min(Δfmax,10 MHz) |
5.5 MHz ≤ f_offset < min(f_offsetmax,10.5 MHz) |
-14.2 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-16 dBm (Note 10) |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 6.7.5.5.3-6 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/MHz. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 8: This frequency range ensures that the range of values of f_offset is continuous. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-4a: MR BS OBUE in BC2 bands applicable for: BS maximum output power Prated,c,TRP ≤ 40 dBm, supporting NR, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-11.2 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-18.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (Note 5) |
100 kHz |
NOTE 1: For AAS BS supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20dBm/100 kHz. NOTE 2: For AAS BS supporting multi-band operation with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.7.5.5.3-6 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 4: Void. NOTE 5: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.3-5: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2 and 3) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
Prated,c,TRP-36.2-60(f_offset-0.015 |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
Prated,c,TRP-39.2-160(f_offset-0.065) |
30 kHz |
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 8: Void. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-6: MR BS OBUE in BC2 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and operating E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2, 3 and 4) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 |
Max(3.8-60(f_offset/MHz-0.015), -16.2) dBm |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
Max(0.8-160(f_offset/MHz-0.065), -16.2) dBm |
30 kHz |
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. NOTE 3: For multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 4: Void. NOTE 8: Void. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-7: LA BS OBUE in BC2 bands
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2 and 3) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz (Note 1) |
0.05 MHz ≤ f_offset < 5.05 MHz |
-19.2-7/5(f_offset/MHz-0.05) dBm |
100 kHz |
5 MHz ≤ Δf < min (10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-26.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (Note 10) |
100 kHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 6.6.5.5.3-8 apply for 0 MHz ≤ Δf < 0.16 MHz. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -28 dBm/100 kHz. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 8: Void. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
Table 6.7.5.5.3-8: LA BS OBUE for operation in BC2 bands applicable for: BS operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 2, 3 and 4) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
Max(-3.2dBm-60(f_offset/MHz-0.015)dB, -24.2dBm) |
30 kHz |
0.05 MHz ≤ Δf < 0.16 MHz |
0.065 MHz ≤ f_offset < 0.175 MHz |
max(-6.2dBm-160(f_offset/MHz-0.065)dB, -24.2 dBm) |
30 kHz |
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. NOTE 3: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the Inter RF Bandwidth gap. NOTE 4: Void. NOTE 8: Void. NOTE 10: The requirement is not applicable when Δfmax < 10 MHz |
NOTE 9: As a general rule for the requirements in the present clause, the resolution bandwidth of the measuring equipment should be equal to the measurement bandwidth. However, to improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.
6.7.5.5.4 MSR Additional requirements
6.7.5.5.4.1 Limits in FCC Title 47
In addition to the requirements in clauses 6.7.5.5.2 and 6.7.5.5.3, the AAS BSW may have to comply with the applicable emission limits established by FCC Title 47 [18], when deployed in regions where those limits are applied, and under the conditions declared by the manufacturer.
6.7.5.5.4.2 Unsynchronized operation for BC3
In certain regions, the following requirements may apply to a TDD AAS BS operating in BC3 in the same geographic area and in the same operating band as another TDD system without synchronisation. For this case the emissions shall not exceed -52 dBm/MHz in each supported downlink operating band except in:
– The frequency range from 10 MHz below the lower Base Station RF Bandwidth edge to the frequency 10 MHz above the upper Base Station RF Bandwidth edge of each supported band.
NOTE 1: Local or regional regulations may specify another excluded frequency range, which may include frequencies where synchronised TDD systems operate.
NOTE 2: TDD Base Stations that are synchronized and operating in BC3 can transmit without these additional co-existence requirements.
6.7.5.5.4.3 Protection of DTT
In certain regions the following requirement may apply for protection of DTT. For an AAS BS operating in Band 20/n20, the level of emissions in the band 470-790 MHz, measured in an 8 MHz filter bandwidth on centre frequencies Ffilter according to table 6.7.5.5.4.3-1, shall not exceed the maximum emission level TRP level shown in the table. This requirement applies in the frequency range 470-790 MHz even though part of the range falls in the spurious domain.
Table 6.7.5.5.4.3-1: Declared emissions levels for protection of DTT
Case |
Measurement filter centre frequency |
Condition on BS maximum aggregate TRP / 10 MHz, PTRP_10MHz (NOTE) |
Maximum Level PTRP,N,MAX |
Measurement Bandwidth |
A: for DTT frequencies where broadcasting is protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10 MHz ≥ 59 dBm |
1.8dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10 MHz < 59 dBm |
PTRP_10 MHz – 57.2 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10 MHz < 36 dBm |
-21.2dBm |
8 MHz |
|
B: for DTT frequencies where broadcasting is subject to an intermediate level of protection |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10 MHz ≥ 59 dBm |
11.8 dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10 MHz < 59 dBm |
PTRP_10 MHz – 47.2 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10 MHz < 36 dBm |
-11.2dBm |
8 MHz |
|
C: for DTT frequencies where broadcasting is not protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
N.A. |
23.8 dBm |
8 MHz |
NOTE: PTRP_10 MHz (dBm) is defined by the expression PTRP_10 MHz = P10 MHz + Gant + 6dB for UTRA and PTRP_10 MHz = P10 MHz + Gant + 9dB for E-UTRA, where Gant is 17 dBi |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions and the deployment (including antenna gain and feeder loss). The method outlined in annex B1, TS 37.105 [6] indicates how the limit in Table 6.7.5.5.4.3-1 demonstrates compliance to the regional requirement.
6.7.5.5.4.4 Co-existence with RNSS/GPS services in North America
In regions where FCC regulation applies, requirements for protection of GPS according to FCC Order DA 20-48applies for operation in Band 24. The following normative requirement covers the base station, to be used together with other information about the site installation to verify compliance with the requirement in FCC Order DA 20-48. The requirement applies to BS operating in Band 24 to ensure that appropriate interference protection is provided to the GPS. This requirement applies in the frequency range 1541-1650 MHz even though part of the range falls in the spurious domain.
The level of emissions in the 1541 – 1650 MHz band, measured in measurement bandwidth according to table 6.7.5.5.4.4-1 shall not exceed the maximum TRP limits indicated in the table.
Table 6.7.5.5.4.4-1: Emissions levels for protection of the 1541-1650 MHz band
Operating Band |
Frequency range (MHz) |
Emission level (dBW) (Measurement bandwidth = 1 MHz) |
Emission level (dBW) of discrete emissions of less than 700 Hz bandwidth (Measurement bandwidth = 1 kHz) |
Emission level (dBW) of discrete emissions of less than 2 kHz bandwidth (Measurement bandwidth = 1 kHz) |
24 |
1541 – 1559 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
|
1559 – 1610 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
||
1610 – 1650 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
NOTE: The regional requirements, included in FCC Order DA 20-48 are defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in TS 37.105 [6] annex B1 indicates how the limit in table 6.7.5.5.4.4-1 demonstrates compliance to the regional requirement in DA 20-48. PEIRP values in table 6.7.5.5.4.4-1are the effective isotropic power (or radiated power spectral density) set in the FCC Order DA 20-48 for the specified frequency ranges and bandwidths.
6.7.5.5.4.5 Void
Table 6.7.5.5.4.5-1: Void
6.7.5.5.4.6 Additional band 32, 50, 51, 74, 75 and 76 unwanted emissions
In certain regions, the following requirements may apply to BS operating in Band 32 within 1452-1492 MHz, in Band 75 within 1432-1517 MHz and in Band 76 within 1427-1432 MHz. The maximum level of unwanted emissions, measured as EIRP, on centre frequencies f_offset with filter bandwidth, according to table 6.7.5.5.4.6-1, shall not exceed the EIRP limits indicated in the table.
For Band 32, this requirement applies in the frequency range 1452-1492 MHz when non-Mobile/Fixed Communications Network (MFCN) services are deployed in adjacent frequency ranges, while it applies also within 1427-1452 MHz and/or 1492-1517 MHz when MFCN services are deployed in such frequency ranges, even though part of the ranges falls in the spurious domain. For Band 75, this requirement applies in the frequency range 1427-1517 MHz. For Band 76, this requirement applies in the frequency range 1432-1517 MHz even though part of the range falls in the spurious domain.
Table 6.7.5.5.4.6-1: Unwanted emission limits within 1427-1517 MHz
Frequency offset of measurement filter centre frequency, f_offset |
EIRP limit [dBm] |
Measurement bandwidth |
2.5 MHz |
16.3 |
5 MHz |
7.5 MHz |
11 |
5 MHz |
12.5 MHz ≤ f_offset ≤ f_offsetmax |
9 |
5 MHz |
NOTE: For Band 32, when non-MFCN services are deployed in the adjacent bands, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1454.5 MHz, and the frequency difference between the upper Base Station RF Bandwidthl edge and 1489.5 MHz for the set channel position. For Band 32, when MFCN services are deployed in the adjacent frequencies, Band 75 and Band 76, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1429.5 MHz, and the frequency difference between the upper Base Station RF Bandwidth edge and 1514.5 MHz for the set channel position. |
In certain regions, the following requirement may apply to BS operating in Band 32 within 1452-1492 MHz for the protection of non-MFCN services in spectrum adjacent to the frequency range 1452-1492 MHz. The maximum level of emissions, measured as EIRP, on centre frequencies Ffilter with filter bandwidth according to Table 6.7.5.5.4.6-2, shall not exceed the EIRP limits indicated in the table. This requirement applies in the frequency range 1429-1518 MHz even though part of the range falls in the spurious domain.
Table 6.7.5.5.4.6-2: Unwanted emission emission limits outside 1452-1492 MHz
Filter centre frequency, Ffilter |
EIRP limit [dBm] |
Measurement bandwidth |
1429.5 MHz ≤ Ffilter ≤ 1448.5 MHz |
-20 |
1 MHz |
Ffilter = 1450.5 MHz |
14 |
3 MHz |
Ffilter = 1493.5 MHz |
14 |
3 MHz |
1495.5 MHz ≤ Ffilter ≤ 1517.5 MHz |
-20 |
1 MHz |
In certain regions, the following requirement may apply to BS operating in Band 50 and Band 75 within 1492-1517 MHz and in Band 74 within 1492-1518 MHz. The maximum level of emissions, measured as EIRP, on centre frequencies Ffilter with filter bandwidth according to table 6.7.5.5.4.6-3, shall not exceed the EIRP limits indicated in the table.
Table 6.7.5.5.4.6-3: Operating band 50, 74 and 75 emission test limits above 1518 MHz
Filter centre frequency, Ffilter |
EIRP limit [dBm] |
Measurement bandwidth |
1518.5 MHz ≤ Ffilter ≤ 1519.5 MHz |
-0.8 |
1 MHz |
1520.5 MHz ≤ Ffilter ≤ 1558.5 MHz |
-30 |
1 MHz |
In certain regions, the following requirement may apply to E-UTRA BS operating in Band 50 and Band 75 within 1432-1452 MHz, and in Band 51 and Band 76. Emissions shall not exceed the test level specified in table 6.7.5.5.4.6-4.
Table 6.7.5.5.4.6-4: Additional unwanted emission limits for BS operating in Band 50 and 75 within 1432-1452 MHz, and in Band 51 and 76
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
Ffilter = 1413.5 MHz |
-42 |
27 MHz |
6.7.5.5.4.7 Additional requirements for band 45
In certain regions the following requirement may apply to E-UTRA BS operating in Band 45. Emissions shall not exceed the maximum levels specified in table 6.7.5.5.4.7-1.
Table 6.7.5.5.4.7-1: Emissions limits for protection of adjacent band services
Operating Band |
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
45 |
Ffilter = 1467.5 |
-11 |
1 MHz |
Ffilter = 1468.5 |
-14 |
1 MHz |
|
Ffilter = 1469.5 |
-17 |
1 MHz |
|
Ffilter = 1470.5 |
-24 |
1 MHz |
|
Ffilter = 1471.5 |
-31 |
1 MHz |
|
1472.5 MHz ≤ Ffilter ≤ 1491.5 MHz |
-38 |
1 MHz |
6.7.5.5.4.8 Additional requirements for band 48
The following requirement may apply to BS operating in Band 48 in certain regions. Emissions shall not exceed the maximum levels specified in table 6.7.5.5.4.8-1.
Table 6.7.5.5.4.8-1: Additional operating band unwanted emission limits for Band 48
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement |
Measurement bandwidth |
All |
0 MHz ≤ Δf < 10 MHz |
0.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |
6.7.5.5.5 E-UTRA
6.7.5.5.5.1 General
The measurement results in clause 6.7.5.4 shall not exceed the maximum levels specified in the tables below, where:
– Δf is the separation between the channel edge frequency and the nominal -3dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the channel edge frequency and the centre of the measuring filter.
– f_offsetmax is the offset to the frequency ΔfOBUE MHz outside the downlink operating band.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB, inside any Inter RF Bandwidth gaps with Wgap < 2×ΔfOBUE MHz, emissions shall not exceed the cumulative sum of the test requirements specified at the Base Station RF Bandwidth edges on each side of the Inter RF Bandwidth gap. The test requirement for Base Station RF Bandwidth edge is specified in Tables 6.7.5.5.5.2-1 to 6.7.5.5.5.2‑9, where in this case:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3 dB point of the measuring filter closest to the Base Station RF Bandwidth edge.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the Inter RF Bandwidth gap minus half of the bandwidth of the measuring filter.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For multi-band RIB, the operating band unwanted emission limits apply also in a supported operating band without any carrier transmitted, in the case where there are carrier(s) transmitted in another supported operating band. In this case, no cumulative limit is applied in the inter-band gap between a supported downlink operating band with carrier(s) transmitted and a supported downlink operating band without any carrier transmitted and:
– In case the inter-band gap between a supported downlink operating band with carrier(s) transmitted and a supported downlink operating band without any carrier transmitted is less than 2×ΔfOBUE MHz, f_offsetmax shall be the offset to the frequency ΔfOBUE MHz outside the outermost edges of the two supported downlink operating bands and the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause, shall apply across both downlink bands.
– In other cases, the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present clause for the largest frequency offset (Δfmax), shall apply from ΔfOBUE MHz below the lowest frequency, up to ΔfOBUE MHz above the highest frequency of the supported downlink operating band without any carrier transmitted.
For a multicarrier E-UTRA TAB connector or a RIB configured for intra-band contiguous or non-contiguous carrier aggregation the definitions above apply to the lower edge of the carrier transmitted at the lowest carrier frequency and the upper edge of the carrier transmitted at the highest carrier frequency within a specified frequency band.
In addition inside any sub-block gap for a RIB operating in non-contiguous spectrum, measurement results shall not exceed the cumulative sum of the test requirements specified for the adjacent sub blocks on each side of the sub block gap. The minimum requirement for each sub block is specified in Tables 6.7.5.5.5.2-1 to 6.7.5.5.5.2-9, where in this case:
– Δf is the separation between the sub block edge frequency and the nominal -3 dB point of the measuring filter closest to the sub block edge.
– f_offset is the separation between the sub block edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the sub block gap bandwidth minus half of the bandwidth of the measuring filter.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
6.7.5.5.5.2 Wide Area BS (Category A)
For E-UTRA RIB operating in Bands 5, 6, 8, 12, 13, 14, 17, 18, 19, 26, 27, 28, 29, 31, 44, 68, 71, 72, 73, 85 emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.5.2‑1 to 6.7.5.5.5.2-3.
Table 6.7.5.5.5.2-1: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E‑UTRA bands < 1 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
9.8 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-0.2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-2.2 dBm |
100 kHz |
10 MHz ≤ Δf Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-4 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-2: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E‑UTRA bands < 1 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
5.8 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4.2 dBm |
100 kHz |
6 MHz ≤ Δf ≤ min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-2.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-4 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-3: Wide Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands < 1 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
For E-UTRA RIB operating in Bands 1, 2, 3, 4, 7, 9, 10, 11, 21, 23, 24, 25, 30, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 45, 48, 65, 66, 69, 70, emissions shall not exceed the maximum levels specified in tables 6.6.5.5.5.2-4, 6.6.5.5.5.2-6 and 6.6.5.5.5.2-8.
For E-UTRA RIB operating in Bands 22, 42, 43, 52 emissions shall not exceed the maximum levels specified in tables 6.6.5.5.5.2-5, 6.6.5.5.5.2-7 and 6.6.5.5.5.2-9.
Table 6.7.5.5.5.2-4: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (1GHz < E‑UTRA bands ≤ 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
9.8 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-0.2 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
3.3 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-2.2 (Note 8) dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-5: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E‑UTRA bands > 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
10 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
0 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
3.3 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-2 (Note 8) dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-6: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (1GHz < E‑UTRA bands ≤ 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
5.8 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4.2 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-2.2 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirmeent within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-7: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E‑UTRA bands > 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
6 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4.0 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-2.0 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-8: Wide Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (1GHz < E-UTRA bands ≤ 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.2-9: Wide Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands > 3 GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
4 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -4 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.5.3 Wide Area BS Category B (Option1)
For Category B Operating band unwanted emissions, there are two options for the limits that may be applied regionally, option 1 is as follows. For E-UTRA AAS BS operating in Bands 5, 8, 12, 13, 14, 17, 20, 26, 27, 28, 29, 31, 44, 67, 68, 71, 72, 73, 85 emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.5.3-1 to 6.7.5.5.5.3-3.
Table 6.7.5.5.5.3-1: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E‑UTRA bands < 1 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
9.8 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-0.2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5.2 dBm |
100 kHz |
10 MHz ≤ Δf Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -7 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-2: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E‑UTRA bands < 1 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
5.8 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4.2 dBm |
100 kHz |
6 MHz ≤ Δf ≤ min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -7 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-3: Wide Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands < 1 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -7 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
For E-UTRA RIB operating in Bands 1, 2, 3, 4, 7, 10, 25, 30, 33, 34, 35, 36, 37, 38, 39, 40, 41, 45, 48, 65, 66, 69, 70, emissions shall not exceed the maximum levels specified in tables 6.6.5.5.5.3-4, 6.6.5.5.5.3-6 and 6.6.5.5.5.3-8.
For E-UTRA RIB operating in Bands 22, 42, 43, 52 emissions shall not exceed the maximum levels specified in tables 6.6.5.5.5.3-5, 6.6.5.5.5.3-7 and 6.6.5.5.5.3-9.
Table 6.7.5.5.5.3-4: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (1GHz < E‑UTRA bands ≤ 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
9.8d Bm – 10/1.4(f_offset/MHz-0,05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-0.2 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
3.3 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4.2 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-5: Wide Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E‑UTRA bands > 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
10dBm – 10/1.4(f_offset/MHz-0,05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
0 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
3.3 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-6: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (1GHz < E‑UTRA bands ≤ 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
5.8 dBm-10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4.2 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4.2 dBm (Note 8( |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-7: Wide Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E‑UTRA bands > 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
6 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-4 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-8: Wide Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (1GHz < E-UTRA bands ≤ 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
3.8 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.3-9: Wide Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands > 3 GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
4 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-3 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.5.4 Wide Area BS Category B (Option 2)
For Category B Operating band unwanted emissions, there are two options for the limits that may be applied regionally, option 2 is as follows.
The limits in this clause are intended for Europe and may be applied regionally for a RIB operating in band 1, 3, 8, 32, 33, 34 or 65.
For a RIB operating in band 1, 3, 8, 32, 33, 34 or 65, emissions shall not exceed the maximum levels specified in table 6.6.5.5.5.4-1 below for 5, 10, 15 and 20 MHz channel bandwidth.
Table 6.7.5.5.5.4-1: Regional Wide Area BS operating band unwanted emission limits
in band 1, 3, 8, 32, 33, 34 or 65 for 5, 10, 15 and 20 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.2 MHz |
0.015 MHz ≤ f_offset < 0.215 MHz |
-3.2 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3.2 dBm – 15(f_offset/MHz-0.215) dB |
30 kHz |
(Note 7) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15.2 dBm |
30 kHz |
1 MHz ≤ Δf ≤ min( 10 MHz , Δfmax) |
1.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-2.2 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 7: This frequency range ensures that the range of values of f_offset is continuous. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
For a RIB operating in band 3, 8 or 65, emissions shall not exceed the maximum levels specified in table 6.7.5.5.5.4‑2 for 3 MHz channel bandwidth.
Table 6.7.5.5.5.4-2: Regional Wide Area BS operating band unwanted emission limits
in band 3, 8 or 65 for 3 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
15.8 dBm – 60(f_offset_MHz-0.015) dB |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0. 065 MHz ≤ f_offset < 0.165 MHz |
12.8dBm-160(f_offset/MHz-0.065) dB |
30 kHz |
0.15 MHz ≤ Δf < 0.2 MHz |
0.165 MHz ≤ f_offset < 0.215 MHz |
-3.2 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3.2 dBm-15(f_offset/MHz-0.215) dB |
30 kHz |
(Note 7) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15.2 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 6 MHz |
1.5 MHz ≤ f_offset < 6.5 MHz, |
-2.2 dBm |
1 MHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4.2 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
|
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 7: This frequency range ensures that the range of values of f_offset is continuous. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
For a BS operating in band 3, 8 or 65, emissions shall not exceed the maximum levels specified in table 6.7.5.5.5.4‑3 for 1.4 MHz channel bandwidth.
Table 6.7.5.5.5.4-3: Regional Wide Area BS operating band unwanted emission limits
in band 3, 8 or 65 for 1.4 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
15.8 dBm – 60(f_offset/MHz-0.015) dB |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0. 065 MHz ≤ f_offset < 0.165 MHz |
12.8 dBm – 160(f_offset/MHz-0.065) dB |
30 kHz |
0.15 MHz ≤ Δf < 0.2 MHz |
0.165 MHz ≤ f_offset < 0.215 MHz |
-3.2 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
-3.2-15(f_offset/MHz-0.215)dB |
30 kHz |
(Note 7) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-15.2 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 2.8 MHz |
1.5 MHz ≤ f_offset < 3.3 MHz |
-2.2 dBm |
1 MHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
3.3 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4.2 dBm (Note 8) |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 8) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -6 dBm/1 MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. NOTE 7: This frequency range ensures that the range of values of f_offset is continuous. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.5.5 Local Area BS (Category A and B)
For an AAS BS of Local Area BS class in E-UTRA bands ≤ 3 GHz, emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.5.5-1, 6.7.5.5.5.5-3 and 6.7.5.5.5.5-5.
For an AAS BS of Local Area BS class in E-UTRA bands > 3 GHz, emissions shall not exceed the maximum levels specified in tables 6.7.5.5.5.5-2, 6.7.5.5.5.5-4 and 6.7.5.5.5.5-6.
Table 6.7.5.5.5.5-1: Local Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
-10.2 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-20.2 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-20.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-22 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -22 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.5-2: Local Area BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
-10 dBm-10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-20 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-20 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-22 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -22 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.5-3: Local Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
-14.2 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-24.2 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-24.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-26 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -26 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.5-4: Local Area BS operating band unwanted emission limits
for 3 MHz channel bandwidth (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
-14 dBm – 10/3(f_offset/MHz-0.05)dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-24 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-24 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-26 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -26 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.5-5: Local Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-19.2 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-26.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -28 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.5-6: Local Area BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-19 dBm – 7/5(f_offset/MHz-0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-26 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -28 dBm/100 kHz. NOTE 2: For BS a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.5.6 Medium Range BS (Category A and B)
For an AAS BS of Medium Range BS class in E-UTRA bands ≤ 3 GHz, emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.5.6-1, 6.7.5.5.5.6-3, 6.7.5.5.5.6-5, 6.7.5.5.5.6-7, 6.7.5.5.5.6-9 and 6.7.5.5.5.6-11.
For an AAS BS of Medium Range BS class in E-UTRA bands > 3 GHz, emissions shall not exceed the maximum levels specified in Tables 6.7.5.5.5.6-2, 6.7.5.5.5.6-4, 6.7.5.5.5.6-6, 6.7.5.5.5.6-8, 6.7.5.5.5.6-10 and 6.7.5.5.5.6-12.
Table 6.7.5.5.5.6-1: Medium Range BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
Prated,c,TRP – 43.2 dB – (10/1.4)*(f_offset-0,05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
Prated,c,TRP -53.2 dB |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-14.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-16 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-2: Medium Range BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
Prated,c,TRP – 43 dB – (10/1.4)*(f_offset-0,05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
Prated,c,TRP -53 dB |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-14 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-16 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -25 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-3: Medium Range BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
-3.2 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-13.2 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-14.2dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-16 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/100 kHz. NOTE 2: For BS a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-4: Medium Range BS operating band unwanted emission limits
for 1.4 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
-3 dBm – 10/1.4(f_offset/MHz-0.05) dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-13 dBm |
100 kHz |
2.8 MHz ≤ Δf < min(10 MHz, Δfmax) |
2.85 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-14dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-16 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -16 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-5: Medium Range BS operating band unwanted emission limits
for 3 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
Prated,c,TRP – 47.2 dB – (10/3)*(f_offset-0,05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
Prated,c,TRP – 57.2 dB |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Min(Prated,c,TRP – 57.2dB, -14.2 dBm) (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP –59 dB, -16 dBm) (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be Min(Prated,c,TRP -59dB, -16 dBm)/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-6: Medium Range BS operating band unwanted emission limits
for 3 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
Prated,c,TRP – 47 dB – (10/3)*(f_offset-0,05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
Prated,c,TRP – 57 dB |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Min(Prated,c,TRP –57 dB, -14 dBm) (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP –59 dB, -16 dBm) (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be Min(Prated,c,TRP -59dB, -16 dBm)/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-7: Medium Range BS operating band unwanted emission limits
for 3 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
-7.2 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-17.2 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-17.2 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-19 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -19 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-8: Medium Range BS operating band unwanted emission limits
for 3 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
-7 dBm – 10/3(f_offset/MHz-0.05) dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-17 dBm |
100 kHz |
6 MHz ≤ Δf < min(10 MHz, Δfmax) |
6.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-17 dBm (Note 8) |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-19 dBm (Note 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -19 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-9: Medium Range BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 51.2dB – (7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP – 58.2 dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP – 60 dB, -16 dBm) (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be Min(Prated,c,TRP -60 dB, -16 dBm)/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-10: Medium Range BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 51 dB-(7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP – 58 dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP – 60 dB, -16 dBm) (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be Min(Prated,c,TRP -60 dB, -16 dBm)/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-11: Medium Range BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands ≤ 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 11.2 dB-(7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-18.2 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -20dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
Table 6.7.5.5.5.6-12: Medium Range BS operating band unwanted emission limits
for 5, 10, 15 and 20 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm (E-UTRA bands > 3 GHz)
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement (Notes 1 and 2) |
Measurement bandwidth |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 11 dB-(7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-18 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the test requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10 MHz from both adjacent sub blocks on each side of the sub-block gap, where the test requirement within sub-block gaps shall be -20 dBm/100 kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE MHz the test requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
6.7.5.5.5.7 Additional requirements
In certain regions the following test requirement may apply. For E-UTRA RIB operating in Bands 5, 26, 27 or 28, emissions shall not exceed the maximum levels specified in Table 6.7.5.5.5.7-1.
Table 6.7.5.5.5.7-1: Additional operating band unwanted emission limits for E-UTRA bands < 1 GHz
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement |
Measurement bandwidth |
1.4 MHz |
0 MHz ≤ Δf < 1 MHz |
0.005 MHz ≤ f_offset < 0.995 MHz |
-12.2 dBm |
10 kHz |
3 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-11.2dBm |
30 kHz |
5 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-13.2 dBm |
30 kHz |
10 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-11.2 dBm |
100 kHz |
15 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-11.2 dBm |
100 kHz |
20 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-11.2 dBm |
100 kHz |
All |
1 MHz ≤ Δf < min(10 MHz, Δfmax) |
1.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-11.2dBm (Note 8) |
100 kHz |
All |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-13 dBm (Note 8) |
100 kHz |
NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
In certain regions the following test requirement may apply. For E-UTRA a RIB operating in Bands 2, 4, 10, 23, 25, 30, 35, 36, 41, 66, emissions shall not exceed the maximum levels specified in Table 6.7.5.5.5.7-2.
Table 6.7.5.5.5.7-2: Additional operating band unwanted emission limits for E-UTRA bands > 1GHz
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement |
Measurement bandwidth |
1.4 MHz |
0 MHz ≤ Δf < 1 MHz |
0.005 MHz ≤ f_offset < 0.995 MHz |
-12.2 dBm |
10 kHz |
3 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-11.2 dBm |
30 kHz |
5 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-13.2 dBm |
30 kHz |
10 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-11.2 dBm |
100 kHz |
15 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-13.2 dBm |
100 kHz |
20 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-14.2 dBm |
100 kHz |
All |
1 MHz ≤ Δf < min(10 MHz, Δfmax) |
1.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-11.2 dBm (Note 8) |
1 MHz |
All |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-13 dBm (Note 8) |
1 Mhz |
NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
In certain regions the following test requirement may apply. For E-UTRA a RIB operating in Bands 12, 13, 14, 17, 29, 85 emissions shall not exceed the maximum levels specified in Table 6.7.5.5.5.7-3.
Table 6.7.5.5.5.7-3: Additional operating band unwanted emission limits
for E-UTRA (bands 12, 13, 14, 17, 29, 85)
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Test requirement |
Measurement bandwidth |
All |
0 MHz ≤ Δf < 100 kHz |
0.015 MHz ≤ f_offset < 0.085 MHz |
-11.2 dBm |
30 kHz |
All |
100 kHz ≤ Δf < min(10 MHz, Δfmax) |
150 kHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-11.2 dBm (Note 8) |
100 kHz |
All |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-13 dBm (Note 8) |
100 kHz |
NOTE 8: The requirement is not applicable when Δfmax < 10 MHz. |
In certain regions, the following test requirements may apply to an E-UTRA TDD RIB operating in the same geographic area and in the same operating band as another E-UTRA TDD system without synchronisation. For this case the emissions shall not exceed -52 dBm/MHz in each supported downlink operating band, except in:
– The frequency range from ΔfOBUE MHz below the lower channel edge to the frequency ΔfOBUE MHz above the upper channel edge of each supported band.
In certain regions the following test requirement may apply for protection of DTT. For E-UTRA a RIB operating in Band 20, the level of emissions in the band 470-790 MHz, measured in an 8 MHz filter bandwidth on centre frequencies Ffilter according to Table 6.7.5.5.5.7-4, shall not exceed the maximum emission TRP level shown in the table. This test requirement applies in the frequency range 470-790 MHz even though part of the range falls in the spurious domain.
Table 6.7.5.5.5.7-4: Declared emissions levels for protection of DTT
Case |
Measurement filter centre frequency |
Condition on BS maximum aggregate EIRP / 10 MHz, PEIRP_10MHz (NOTE) |
Maximum Level PEIRP,N,MAX |
Measurement Bandwidth |
A: for DTT frequencies where broadcasting is protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PEIRP_10 MHz ≥ 59 dBm |
1.8dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PEIRP_10 MHz < 59 dBm |
PEIRP_10 MHz – 57.2 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PEIRP_10 MHz < 36 dBm |
-21.2dBm |
8 MHz |
|
B: for DTT frequencies where broadcasting is subject to an intermediate level of protection |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PEIRP_10 MHz ≥ 59 dBm |
11.8dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PEIRP_10 MHz < 59 dBm |
PEIRP_10 MHz – 47.2 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PEIRP_10 MHz < 36 dBm |
-11,2dBm |
8 MHz |
|
C: for DTT frequencies where broadcasting is not protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
N.A. |
23.8dBm |
8 MHz |
NOTE: PEIRP_10 MHz (dBm) is defined by the expression PEIRP_10 MHz = P10 MHz + Gant + 6dB for UTRA and PEIRP_10 MHz = P10 MHz + Gant + 9dB for E-UTRA, where Gant is 17 dBi |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions and the deployment (including antenna gain and feeder loss). The method outlined in annex B1, TS 37.105 [6] indicates how the limit in Table 6.7.5.5.5.7-4 demonstrates compliance to the regional requirement.
In regions where FCC regulation applies, requirements for protection of GPS according to FCC Order DA 20-48applies for operation in Band 24. The following normative requirement covers the base station, to be used together with other information about the site installation to verify compliance with the requirement in FCC Order DA 20-48. The requirement applies to BS operating in Band 24 to ensure that appropriate interference protection is provided to the GPS. This requirement applies in the frequency range 1541-1650 MHz even though part of the range falls in the spurious domain.
The level of emissions in the 1541 – 1650 MHz band, measured in measurement bandwidth according to table 6.7.5.5.5.7-5 shall not exceed the maximum TRP limits indicated in the table.
Table 6.7.5.5.5.7-5: Emissions test requirements for protection of the 1541-1650 MHz band
Operating Band |
Frequency range (MHz) |
Emission level (dBW) (Measurement bandwidth = 1 MHz) |
Emission level (dBW) of discrete emissions of less than 700 Hz bandwidth (Measurement bandwidth = 1 kHz) |
Emission level (dBW) of discrete emissions of less than 2 kHz bandwidth (Measurement bandwidth = 1 kHz) |
24 |
1541 – 1559 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
|
1559 – 1610 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
||
1610 – 1650 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
NOTE: The regional requirements, included in FCC Order DA 20-48 are defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in TS 37.105 [6], Annex B1 indicates how the limit in table 6.7.5.5.5.7-5 demonstrates compliance to the regional requirement in DA 20-48. PEIRP values in table 6.7.5.5.5.7-5 are the effective isotropic power (or radiated power spectral density) set in the FCC Order DA 20-48 for the specified frequency ranges and bandwidths.
Table 6.7.5.5.5.7-6: Void
For BS operating in bands n50, n51, n74, n75 and n76 additional emission limits are specified in clauses 6.7.5.5.4.6.
Table 6.7.5.5.5.7-7: void
Table 6.7.5.5.5.7-8: void
Table 6.7.5.5.5.7-8a: void
Table 6.7.5.5.5.7-8b: void
In certain regions the following requirement may apply to E-UTRA BS operating in Band 45. Emissions shall not exceed the maximum levels specified in table 6.7.5.5.5.7-9.
Table 6.7.5.5.5.7-9: Emissions limits for protection of adjacent band services
Operating Band |
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
45 |
Ffilter = 1467.5 |
-11 |
1 MHz |
Ffilter = 1468.5 |
-14 |
1 MHz |
|
Ffilter = 1469.5 |
-17 |
1 MHz |
|
Ffilter = 1470.5 |
-24 |
1 MHz |
|
Ffilter = 1471.5 |
-31 |
1 MHz |
|
1472.5 MHz ≤ Ffilter ≤ 1491.5 MHz |
-38 |
1 MHz |
The following requirement may apply to BS operating in Band 48 in certain regions. Emissions shall not exceed the maximum levels specified in table 6.7.5.5.5.7-10.
Table 6.7.5.5.5.7-10: Additional operating band unwanted emission limits for Band 48
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Testrequirement |
Measurement bandwidth |
All |
0 MHz ≤ Δf < 10 MHz |
0.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |