G.2 Normal test environment
37.145-23GPPActive Antenna System (AAS) Base Station (BS) conformance testingPart 2: radiated conformance testingRelease 17TS
When a normal test environment is specified for a test, the test should be performed within the minimum and maximum limits of the conditions stated in table G.2-1.
Table G.2-1: Limits of conditions for Normal Test Environment
Condition |
Minimum |
Maximum |
Barometric pressure |
86 kPa |
106 kPa |
Temperature |
15°C |
30°C |
Relative Humidity |
20 % |
85 % |
Power supply |
Nominal, as declared by the manufacturer |
|
Vibration |
Negligible |
The ranges of barometric pressure, temperature and humidity represent the maximum variation expected in the uncontrolled environment of a test laboratory. If it is not possible to maintain these parameters within the specified limits, the actual values shall be recorded in the test report.