B.4 Moving propagation conditions

36.1413GPPBase Station (BS) conformance testingEvolved Universal Terrestrial Radio Access (E-UTRA)Release 17TS

Figure B.4-1 illustrates the moving propagation conditions for the test of the UL timing adjustment performance. The time difference between the reference timing and the first tap is according Equation (B.4-1). The timing difference between moving UE and stationary UE is equal to Δτ – (TA −31)×16Ts. The relative timing among all taps is fixed. The parameters for the moving propagation conditions are shown in Table B.4-1.

Figure B.4-1: Moving propagation conditions

(B.4-1)

Table B.4-1: Parameters for UL timing adjustment

Parameter

Scenario 1

Scenario 2

Channel model

Stationary UE: AWGN

Moving UE: ETU200

AWGN

UE speed

120 km/h

350 km/h

CP length

Normal

Normal

A

10 s

10 s



0.04 s-1

0.13 s-1

NOTE 1: Multipath fading propagation conditions for Scenario 1 were derived for Band 1 with additional rounding applied to the Doppler frequency calculated for the specified UE speed.

NOTE 2: In Scenario 2, the UE speed is only used to calculate and the Doppler shift is not applied to the channel.