The set-up of physical channels for transmitter tests shall be according to the NB-IoT Test Model (N-TM) below.
The following general parameters are used:
– The test models are defined for a single antenna port (using p = 1000);
– Duration is 10 subframes (10 ms)
– Normal CP
The following physical channel parameters are used:
– The ratio of synchronisation signal EPRE and NRS EPRE is 0 dB
– NPDCCH format 1
For NB-IoT TDD, test models are derived based on the uplink/downlink configuration 1 and special subframe configuration 7 defined in TS 36.211 [12], i.e. as showing in the table 6.1.3-1. Number of frames for the test models is 2.
Table 6.1.3-1: Configurations of TDD eNB test models
Downlink-to-Uplink Switch-point periodicity |
Number of UL/DL sub-frames per radio frame (10 ms) |
DwPTS |
GP |
UpPTS |
|
DL |
UL |
||||
5ms |
4 |
4 |